Incubators

Items 1 to 20 of 68

Image of item

£ 225.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 4430 Incubator Shaker Lab - Spares / Repairs

ITEM-14875

This New Brunswick Scientific Innova 4430 Incubator Shaker was removed from a university where it was surplus to requirements.


The unit has been powered up and tested and it does appear to be able to hold a temperature. It was tested at 37degC where our thermometer showed 33degC and was tested up to max temp of 80degC. Our thermometer showed 79degC.

The shaker parts appear to have been removed, although when setting an rpm on the controls, you can see the motor spin up.


It is in reasonable cosmetic condition but has seen heavy use. Despite the way it looks, and that some parts are missing it actually seems to work really well. It will require some work and new parts to get the unit fully working again.


Unit is sold as spares / repairs.

Image of item

£ 90.00 (ex. VAT) 1 in stock

Amersham Amerlite Microtitre Plate Air Incubator Lab

ITEM-13669

This Microtitre Plate Incubator was removed from a university where it was surplus to requirements.


The unit powered on in testing and heated up (see photos).


The unit has closed temperature control with a temp range of 20-50 degrees. the two chamber spaces are both 127x210x20mm LWH.






Image of item

£ 274.63 (ex. VAT) 1 in stock

Appligene Oncor Crocodile III TC2000 Microprocessor Controlled Incubation System

ITEM-12172

This item was removed from a lab as surplus to requirements.


The lab manager informed us it was in full working order when last used.


At our site we have powered it on but not tested it further.

Image of item

£ 225.00 (ex. VAT) 1 in stock

Binder C150 C02 Laboratory Incubator Lab Spares / Repairs

ITEM-19488

This Binder C150 C02 Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up but it seems to have some sort of screen fault that prevented it from being tested any further.


It is in good cosmetic condition with some marks from use.


Internal dimensions;

50cm D x 50cm W x 59cm H.


No racking or shelves are included.


Image of item

£ POA 1 in stock

Binder CB 150 CO2 Laboratory Incubator Lab

ITEM-19873

This Binder CB 150 CO2 Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up but the screen is partially faulty and has a black strip covering some of the left of the screen. We were still able to test it though.


It was tested with a digital thermometer (not included). It was set to 37˚C which it reached after about an hour, and then the max of 60˚C which it reached after a further 2 hours.


It is in reasonably good cosmetic condition with some marks from use.


Internal dimensions - D50 x W50 x H59cm

3 Shelves 44.5 x 49.5cm

1 Bottom Tray - 46 x 36 x 3cm


Image of item

£ POA 1 in stock

Binder CO2 Laboratory Incubator Model - C150 Lab

ITEM-19872

This Binder CO2 Laboratory Incubator Model - C150 was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). It was set to 37˚C which it quickly reached, and then the max of 50˚C which it reached after about an hour.


It is in reasonably good cosmetic condition with some marks from use.


Internal dimensions - D50 x W50 x H59cm

3 Shelves 44.5 x 49.5cm



Image of item

£ POA 1 in stock

Binder Model CB 150 CO2 Laboratory Incubator Lab

ITEM-19874

This Binder Model CB 150 CO2 Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and was tested with a digital thermometer (not included). It was set to 37˚C which it reached after about an hour, and then the max of 60˚C which it reached after a further 2 hours.


There is a defect running down the middle of the screen but it doesn't seem to affect the operation of the unit too much.


It is in reasonably good cosmetic condition with some marks from use.


Internal dimensions - D50 x W50 x H59cm

3 Shelves 44.5 x 49.5cm

Image of item

£ POA 1 in stock

Binder Series B Standard Incubator Model 28 Lab

ITEM-20082

This Binder Series B Standard Incubator Model 28 was removed from a university lab where it was surplus to requirements.


The unit powers up and the timer is working. The incubator was tested with a digital thermometer (not included).

When set to 50˚C it reached 50.1˚C

When set to 150˚C it reached 143.7˚C

When set to 230˚C it reached 222.1˚C


It is in good cosmetic condition with minor usage marks and stains.


Interior measurements

25cm D, 40cm W, 28cm H


1x Wire Rack

39cm L, 24cm W, 4cm H


Image of item

£ 375.00 (ex. VAT) 1 in stock

Boekel Illumina Hybridisation Oven / Incubator Model 5420 Lab

ITEM-18313

This Boekel Illumina Hybridisation Oven/Incubator Model 5420 was removed from a university lab where it was surplus to requirements.


The unit is in good cosmetic condition but has some marks from use. There is a rubber mat with it for the shaker tray.


The unit powers up and it spun well at 5 (Min), 30 and 60 (Max) RPM.


It was tested with a digital thermometer (not included).

When tested to get to 37˚C it had to be set to 35.7˚C

When tested to 37˚C it was actually 39.5˚C on the thermometer.

When tested to 100 degrees (Max) it only displayed 99˚C but was recorded at 105.8˚C on the thermometer.



Internal dimensions: 34cm L x 24.5cm W x 22.5cm H.

Shelf dimensions: 20.5cm L x 28cm W.

Shelf dimensions inside the lip: 20cm L x 27.5cm W.


Image of item

£ POA 1 in stock

Gallenkamp Economy Laboratory Incubator with Fan Size 1 Lab

ITEM-18888

This Gallenkamp Economy Laboratory Incubator with Fan Size 1 was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). The temperature took around 15 minutes to reach 37 degrees when set. It was then set to the maximum number on the dial of 80 degrees and it reached 73 degrees after running for 2 hours.


It is in reasonably poor cosmetic condition and is heavily stained. It doesn't however seem to affect the operation of the unit.


Inside dimensions:-

Depth - 36cm

Width - 48cm

Height - 33cm

1 Shelf - 48x31cm




Image of item

£ POA 1 in stock

Gallenkamp Incubator Shaker Cat No. OTSHTD.EU1.C - Faulty Touchscreen Lab

ITEM-19441

This Gallenkamp Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit powers up but there seems to be a fault with the touch screen. It is blank. We left it on for a while, but it never came on. It was not tested further.


It is in reasonably good cosmetic condition but has marks from use. It is clean inside.


Internal dimensions - W84 X L54 D43cm

Shaker platform - 69 x 48cm, 12 x flask clamps


It is for spares or repairs due to the fault.

Image of item

£ 500.00 (ex. VAT) 1 in stock

GENLAB MINI/40 Benchtop Laboratory Incubator Lab

ITEM-19356

This GENLAB MINI/40 Benchtop Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). We first set the temperature to 37˚C which it reached after about 10 minutes. It was then set to 70˚C which it reached, and then up to the max of 100˚C which it reached after about an hour.


It is in reasonably good cosmetic condition but has some marks from use.


Image of item

£ 562.50 (ex. VAT) 1 in stock

Heraeus / Kendro Cytomat 2C4 Laboratory Incubator Lab Spares / Repairs

ITEM-19457

Heraeus/Kendro Cytomat 2C4 Laboratory Incubator


This was removed from a lab during a clearout. The lab reported:


"We’ve got a Cytomat 2C (refrigerated) which is partially operational – but only as ambient storage as I believe there is an issue with the compressor."


The unit powers up but there are no controls to operate the parts inside. it looks as though it needs to be connected to another device via the RC232. We were unable to set the temperature also. We have not attempted any repairs on the compressor.


It is in good cosmetic condition with only minor usage marks.


Pieces Inside:-

1 x Kendra PSS Cytomat 2

1 x Keyence BL-601 Laser Barcode Reader

2 x Slot towers inside (21 Slots at 2cm) - H51cm x W11.5 x L14cm


Inside dimensions without racking - D34 x W32 x H73.5cm


System is sold as spares / repairs.

Image of item

£ POA 1 in stock

Heraeus Hera Cell 240 CO2 Laboratory Incubator with Trolley Lab

ITEM-19302

This Heraeus Hera Cell 240 CO2 Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). It was first set to 37˚C which it reached after about half an hour, and then the max temp of 55˚C which was reached after about an hour. It was not tested with CO2.


It is in reasonably good cosmetic condition with some marks from use.


Internal dimensions - D56 X W60 H67cm

6 Shelves 50 x 27cm

Image of item

£ POA 1 in stock

Heraeus HeraCell 150 CO2 Laboratory Incubator Lab

ITEM-18316

This Heraeus HeraCell 150 CO2 Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested. To get to 37 degrees C the unit was set to 36. It held successfully. When tested to 55 degrees C (Max) our thermometer read 55.3C.


The unit is in reasonable condition but has signs of heavy use. The inside is very discoloured due to the nature of what it was used for. The drip tray underneath is cracked and doesn't seem to slide well underneath.


Included with it are a set of shelves and a stainless steel box.


Inner dimensions: 47.5cm L x 54cm W x 61cm H.

Shelf dimensions: 46.5cm L x 42cm W.

Box dimensions: 46cm L x 49.5cm W x 22cm H.


Image of item

£ 1,200.00 (ex. VAT) 1 in stock

Heraeus HERAcell Laboratory CO2 Incubator Lab

ITEM-19357

This Heraeus HERAcell Laboratory CO2 Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included) It was first set to 37˚C which it took about half an hour to reach. Our thermometer measured it at 41C. It was then set to the max of 55C. The displayed temperature was 54.9 and our thermometer measured 60˚C. It seems to be a little off with accuracy.


It is in reasonably good cosmetic condition but has some marks from use.




Image of item

£ POA 1 in stock

Heraeus Instruments Type: B 6120 Laboratory Incubator Lab

ITEM-20084

This Heraeus Instruments Type: B 6120 Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included).

When set to 37˚C it reached 36˚C.

When set to 70˚C it reached 68.8˚C.


It is in reasonable cosmetic condition but has signs of heavy use. There are quite a lot of scratches as well as sticker residue.


Internal dimensions.

54cm L x 35cm D x 50cm H


Image of item

£ POA 1 in stock

Heraeus Laboratory Incubator Typ B 5060 EK-C02 Lab

ITEM-19378

This Heraeus Laboratory Incubator Typ B 5060 EK-C02 was removed from a university lab where it was surplus to requirements.


The unit powers up and was tested with a digital thermometer (not included). We set it to 37C which it reached after about an hour. We then set it to 50C (mac) which it hit but hovered around 49 and 50. It took about 2 hours to get to the max temperature after hitting 37.


It is in reasonable cosmetic condition but has some heavy marks from use. It is not damaged.


Unit dimensions - L76 x W90 x H79cm

Internal dimensions - D57 x W60 x H60cm

6 Shelves 51 x 27.5cm



Image of item

£ POA 1 in stock

Heraeus Laboratory Incubator Typ B 5060 EK-C02 with Trolley Lab

ITEM-19411

This Heraeus Laboratory Incubator Typ B 5060 EK-C02 was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). It was first set to 37C but the thermometer didn't get higher than 35C. It was then set to the max of 50C but it only reached 41C. The UV light does not work and there was condensation inside before we began testing it.


it is in reasonably good cosmetic condition but has plenty of surface scratches and scuffs. it comes with a trolley.


Unit dimensions - L76 x W90 x H79cm

Internal dimensions - D57 x W60 x H60cm

6 Shelves 51 x 27.5cm




Image of item

£ POA 1 in stock

Heto Cellhouse 170 HI Model 170-300 CO2 Laboratory Incubator Lab

ITEM-19303

This Heto Cellhouse 170 HI Model 170-300 CO2 Laboratory Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). Firstly, it was set to 37˚C. It didn't quite make it on the display of the unit which showed 36.8˚C but the thermometer measured it at 37˚C. Likewise, when it was set to the max of 50˚C the display read 48.9˚C and the thermometer measured over 50˚C. It was not tested with CO2.


2 Shelves - 52 x 49cm


It is in reasonably good cosmetic condition with some marks from use.

Items 1 to 20 of 68