Items 1 to 20 of 63

Image of item

£ 302.13 (ex. VAT) 1 in stock

MJ Research PTC-225 Gradient Thermal Cycler DNA PCR Lab

ITEM-13850

This MJ Research PTC-225 Thermal Cycler was removed from a university as it was surplus to requirements.


Unfortunately we were unable to test the unit as the Tyco Series S1 Power Supply shows a fault light.


It is in moderate cosmetic condition overall. There are a few scratches etc on the body of the unit.


Included as well are 3 x Alpha 96 Units and one blanking plate.

Image of item

£ POA 1 in stock

4 x MJ Research Alpha Unit Block Assembly for PTC DNA Engine Systems Lab

ITEM-19965

4 x MJ Research Alpha Unit Block Assembly for PTC DNA Engine Systems


These were removed from a university lab where it was surplus to requirements.


All the blocks are in reasonably good cosmetic condition and have 384 x 3mm wells.


None of the units have been tested.




Image of item

£ 93.75 (ex. VAT) 1 in stock

Alpha Unit Block Assembly BioRad PTC DNA Engine Systems Thermal Cycler PCR Lab

ITEM-16004

This Alpha Unit Block Assembly For BioRad PTC DNA Engine Systems Thermal Cycler was removed from a university laboratory where it was surplus to requirements.


The unit has not been tested but is in reasonably good condition. There are a few marks on the exterior and inside the sample tray. The sample tray can hold up to 60 samples at once.



Image of item

£ POA 1 in stock

Applied Biosystems 7000 96 Well Block Accessory/Assembly PN 4322883 Lab

ITEM-18480

This Applied Biosystems 7000 96 Well Block Accessory/Assembly PN 4322883 was removed from a university lab where it was surplus to requirements.


The unit is brand new and unused. It was taken out of the packaging for photos only.

Image of item

£ 84.17 (ex. VAT) 1 in stock

Applied Biosystems GeneAmp PCR System 2400 Thermal Cycler PCR DNA Lab

ITEM-10832

This unit was removed from a lab during a clearout.


The unit powers on and the various controls seems to work.


When set to 94C it actually achieved 84C so unit requires some recalibration.

Image of item

£ 2,032.12 (ex. VAT) 1 in stock

Applied Biosystems Veriti 96 Well Thermal Cycler PCR DNA Lab

ITEM-13252

This unit was removed from a lab as surplus to requirements. We were assured it was in good working order.


At our site we have tested the unit and it passes all self tests and is in excellent condition.


We have not tested the unit with samples.


Image of item

£ POA 1 in stock

Bio-Rad C1000 Thermal Cycler Lab Spares or Repairs

ITEM-16887

This Bio-Rad C1000 Thermal Cycler With Dual 48 Well Heads was removed from a lab during a clearance.


Cosmetically it is in good condition but has marks from use.


The unit has no well module and just clicks when it is powered up. The screen doesn't light up at all.


It is sold for spares or repairs.

Image of item

£ 3,000.00 (ex. VAT) 1 in stock

Bio-Rad ICycler iQ5 Multicolor Real-Time PCR Detection System Lab

ITEM-17300

This Bio-Rad ICycler iQ5 Multicolor Real-Time PCR Detection System was removed from a university lab where it was surplus to requirements.


The unit powers up but was not tested further. It showed that 10/10 stages of self-check were completed, however, we could not check the temperature as the system informed us that some functions may not be performed.


It is in good cosmetic condition with some marks from use.


Image of item

£ 195.86 (ex. VAT) 1 in stock

Bio-Rad iCycler Thermal Cycler PCR DNA Lab - Spares / Repairs

ITEM-13234

This unit was removed from a lab as surplus to requirements.


At our site, we powered the unit on and it passed all self tests and seems to run cycles and work well.


Unfortunately this is an item that has been previously returned to us. The well temperatures were measured immersing the probe of a precision thermometer into a tube containing 50 microliters of water, and this is the result: at 95°C the well temp is 84.5, at 59°C the well is at 55.4, at 72°C the well is at 65.2.


Unit is therefore sold as spares / repairs.

Image of item

£ 375.00 (ex. VAT) 1 in stock

Bio-Rad MyCycler Thermal Cycler System PCR Lab Spares/Repairs

ITEM-11192

This Bio-Rad MyCycler Thermal Cycler System was removed from a university where it was surplus to requirements.


The unit powers on and heats up, however, the directional and enter buttons appear to not be functional. It will not allow you to select any programs to run.


It is in good cosmetic condition but has been previously used.


It is sold for spares or repairs due to the fault.

Image of item

£ 337.50 (ex. VAT) 2 in stock

Bio-Rad PTC-100 Thermal Peltier Cycler Model PCR - PTC1196 Lab

ITEM-19854

This Bio-Rad PTC-100 Thermal Peltier Cycler Model - PTC1196 was removed from a university lab where it was surplus to requirements.


We were assured this unit was in good working oder.


At our site, the unit powers up and has been tested with a digital thermometer. It was set to run at both 37˚C and 99˚C. Our thermometer was slightly out, but it heated to and held at both temperatures our thermometer is not precisely calibrated so the error could easily be in the thermometer, or positioning of the probes - or the unit may require calibrating. We have not looked into it further.


It is in reasonably good cosmetic condition but has some marks from use.


The Heating Block has 96 x 4.30mm tube wells.


Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving before it is shipped, we would be happy to provide this.


Image of item

£ 159.35 (ex. VAT) 1 in stock

Bio-Rad Thermal Cycler PCR iCycler Well Reaction Model Lab Spares or Repairs

ITEM-10085

This Bio-Rad Thermal Cycler PCR iCycler Well Reaction Model was removed from a laboratory where it was surplus to requirements.


The unit is in reasonable, used cosmetic condition but it shows a lid fault on startup, so will not function.


Sold as spares or repairs.


Image of item

£ POA 1 in stock

Bioer Life Touch Thermal Cycler Model - TC-96/G/H(b)B Lab

ITEM-19880

This Bioer Life Touch Thermal Cycler Model - TC-96/G/H(b)B was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). We set a program to run at 37˚C, 70˚C, 99˚C and then back down to 70˚C, 37˚C and finally 10˚C. It heats and runs accurately.


It has a 96 Well block with 40mm wells. (0.2mL)


It is in good cosmetic condition with only light marks from use.


Image of item

£ POA 1 in stock

Biometra T1 Thermocycler T1-Thermoblock Thermal Cycler PCR Lab

ITEM-19346

This Biometra T1 Thermocycler T1-Thermoblock Thermal Cycler was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included).


It was set to 37˚C and our thermometer read 36˚C. It was then set to the minimum of -0.3˚C and reached 0. Finally, it was set to the max of 99.9˚C and reached 103˚. There was a label on it when it came to us saying it doesn't cool down, but we were unable to confirm any faults. It seems to heat and cool well but we have not run any cycles with it.


It is in good cosmetic condition with some marks from use.


Image of item

£ 642.83 (ex. VAT) 1 in stock

Biometra T3 Bench-Top Thermocycler 3x 48 Well Blocks Lab PCR

ITEM-15325

This Biometra T3 Bench-Top Thermocycler was removed from a laboratory where it was surplus to requirements.


The unit powers on and has been tested. All 3 blocks heat as they should. They have all been tested to 37 Celsius and the max of 99 Celsius.


There are some cosmetic faults however. 2 of the block lids are faulty. The centre and far right lid have broken top controls. The lid heater can be adjusted but the top knobs are snapped off and have just been placed bakc on.


However the unit does appear to work and all 3 blocks heat as they should.


The system has not been tested with samples.




Image of item

£ 546.41 (ex. VAT) 1 in stock

Biometra T3 Thermoblock Benchtop Thermal Cycler Lab PCR

ITEM-15324

This Biometra T3 Thermoblock Bench-Top Thermal Cycler was removed from a laboratory where it was surplus to requirements.


The unit powers on and in testing was found to be working, but there are a few issues with it. The screen is quite dim and difficult to read and the unit takes longer than it should to boot up. Some of the text at the bottom of the screen is also scrambled.


All 3 heating blocks appear to be in full working order and were tested at both 37 celsius and the max of 99 celsius.


Unit has not been tested with samples.

Image of item

£ 417.84 (ex. VAT) 1 in stock

Biometra TGGE Maxi Gel Transfer System + Power Supply & Controller Lab

ITEM-14248

Biometra TGGE Maxi Thermoblock System With Power Supply.


This item was removed from a lab during a clear out.


The system includes:


TGGE Maxi System controller.

TGGE Maxi Power supply.

TGGE Maxi System.


The controller powers up but shows a Thermoblock connection error.

It doesn't appear that we have all the correct cables for the system.

We believe it is missing at least one serial type cable.

Good cosmetic condition.

We tested it as far as we could.

As such we cannot confirm the operational condition of this unit.

We would suggest that a full service and inspection is carried out prior to use.


Please see photos for further details.




Image of item

£ 109.85 (ex. VAT) 1 in stock

Biometra Trio Thermoblock TD-1 Thermal Cycler PCR

ITEM-09243

This unit was removed from a lab during a clearout.


We powered on the unit and it appears to run properly, but we have not tested it fully.

Image of item

£ 182.14 (ex. VAT) 1 in stock

BioMetra TRIO-Thermoblock 3-Block Thermal Cycler PCR DNA Lab

ITEM-07179

This unit was removed from a lab during a clearout.


The unit powers on but there is a printer error when trying to run cycles. We are not sure if this is just a setting error or if the unit is faulty.


Interested buyers are welcome to buy the unit and if it is faulty return for a full refund.


Image of item

£ POA 1 in stock

Biometra TRIO-Thermoblock Model TB1 Lab

ITEM-18983

This Biometra TRIO-Thermoblock Model TB1 was removed from a university lab where it was surplus to requirements.


The unit is in reasonably good cosmetic condition with some marks from use. We have put new feet on it as the original feet had begun to wear away.


The unit powers up and has been tested with a digital thermometer (not included). We managed to activate the three blocks and test them at the temperature they were already set at. We weren't sure how to change the settings At the moment Block 1 = 42C maximum, Block 2 = 99C maximum and Block 3 = 70C maximum. All the blocks heated well and accurately to the setting. It was not tested further.


The tube wells are 7.5mm in diameter.




Items 1 to 20 of 63