Gas Chromatography (GC)
Items 1 to 20 of 34
£ 4,160.00 (ex. VAT) 1 in stock
Thermo Finnigan Trace GC Ultra, TriPlus AS Autosampler Lab
ITEM-16337
This Thermo Finnigan Trace GC System was removed from a university laboratory where it was surplus to requirements.
All the units are in good, used cosmetic condition, and all power up. We were unable to test them further than this, however.
The system comes supplied without a detector. The ECD one that was inside has been retained by the lab.
The system consists of:
1 x Finnigan Trace GC Ultra With TriPlus AS Autosampler.
1 x Thermo TP100 Sampler Supply
It also comes with some spares and cables.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 4,145.00 (ex. VAT) 1 in stock
Perkin Elmer TurboMatrix 650 Thermal Desorber Lab Spares/Repairs
ITEM-31478
Perkin Elmer TurboMatrix 650 Thermal Desorber
This was removed from a university lab where it was surplus to requirements.
The Unit powers on but the display isn't functional at all. It just shows a pixellated image.
It is in good cosmetic condition with only minor marks from use.
It is sold for spares/repairs.
£ POA 1 in stock
Perkin Elmer GC Gas Chromatograph Clarus 480 Lab
ITEM-35471
This item is new in stock. Please enquire for further details.
£ 3,015.00 (ex. VAT) 1 in stock
Hewlett Packard HP 6890 Series GC System G1540A , G1513A, G1512AX Lab
ITEM-24522
This Hewlett Packard HP 6890 Series GC System was removed from a university lab where it was surplus to requirements.
The unit has been powered up but not tested further at our facility. The lab said it had been serviced in May 2022 and so should be in good working order.
Included are;
1 x Hewlett Packard HP 6890 Series GC System
G1540A
1 x HP GC Autosampler
G1512AX
1 x Agilent 6890 Series Injector
G1513A
1 x Hewlett Packard 5973 MassSelective Detector.
Accessories:
Cables:
1x 9pin FEMALE to FEMALE RS232 Cable: Part no, G1530-60600
•TO6890A
Auto Sampler to GC - GC to Data Box (Data Box is missing from system)
1x 9pin MALE to Male RS232 Cable:
Part no. G1530-60930
Top Remote on GC - Data Box
2x Hewlett Packard Controller Cables:
Part no's.
• 10833B
•10833D
£ 1,750.00 (ex. VAT) 1 in stock
Thermo Finnigan Trace GC Ultra & AS2000 Autosampler Model K0333B730000090 Lab
ITEM-12617
This Finnigan Trace GC Ultra & AS2000 Autosampler was removed from a university lab where it was surplus to requirements.
The unit is in good used cosmetic condition. It powers up fine and the oven heats.
The fan is very very noisy. We presume the bearings have gone in it.
It also comes with a Thermo Finnigan AS2000 Autosampler and C.U. Controller. The controller powers up.
Various cables are also included including a spare fan.
£ 1,600.00 (ex. VAT) 1 in stock
Thermo Scientific Trace GC Ultra with AS 3000 II Auto-Sampler Lab
ITEM-35316
Thermo Scientific Trace GC Ultra with AS 3000 II Auto-Sampler
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it completely at our facility.
It is in good cosmetic condition with marks from use.
The item is supplied with a Thermo AS 3000 II Auto-Sampler. The 24v DC PSU was not supplied with the unit.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,475.00 (ex. VAT) 1 in stock
Thermo Scientific Trace GC Ultra GC-MS - DSQ II / Triplus AS Spares/Repairs
ITEM-39822
This GC-MS Thermo Scientific Trace GC Ultra / DSQ II / Triplus AS was removed from a university lab where it was surplus to requirements.
The system has some faults and is sold for spares/repairs.
Included are;
Thermo Scientific Trace GC Ultra
Model: K0533B730000470
Serial#: 20083080
Item powers on with display screen and all LED lights in working order.
Item successfully pairs with AutoSampler which preforms a self calibration when powered on, displaying motor in good working order.
When the oven started to heat up smoke started rising from the top of the unit.
We took the top panel off and found that the Parker Vac-1250 psig Pulse Valve had burnt causing the smoke.
Thermo Scientific TriPlus TP111 AS Liquid Handler Turret
Serial#: 20082631
This turret is fitted to the Trace GC Ultra.
Item powers on with connection to power supply box.
Pairs successfully to Trace GC Ultra.
Motor is in good working order with no noticeable/audible fault.
ThermoFisher Scientific SAQ II
Model: Trace SAQ II Mass Spectrometer
Serial#: MS220-5598
Item is in good cosmetic condition.
No indication that item powers on.
Item failed PAT on insulation.
Edwards 3 Vacuum Pump
Model: RV3
Serial#: 086048631
Item is in reasonably good cosmetic condition.
Item powers on and draws suction.
Passed PAT.
ThermoFisher Ion Volume Insertion/Removal Tool
Thermo Scientific TriPlus TP111 AS Liquid Handler Turret *FAULTY*
Serial#: 20080373
Accessories:
Thermo Recorder Cable L+1900 MM
Part#: 23038071
Thermo Tigth Seal for Insert
Part#: 29013417
Thermo Locking Nut m4
Part#: 35032423
Thermo Graphite Sealing Ring Batch H10-A402
Part#: 29033406
Thermo Nut for Cold SSL
Part#: 35002423
Thermo Graphite Seal Use"S"
Part#: 29003629
Thermo Spacer (pkg 2)
Part#: 29014278
Thermo Cable Female 4 Poles
Part#: 23809602
SGE Injection port Liners
Ion Volume Holder x 7
Part#: 70001-20532
Thermo Inlet Seal Trace PTV, 2pkg
Part#: 29013417
Thermo Septa Coated BTO X-145 1/2" x 2
Part#: 31313225
Thermo TP 502
Serial#: 20091133
Thermo Multi-Ferrules Pack Set of 6 x 2
Part#: 29005065
Thermo Septa coated BTO 17mm (50/pk)
Part#: 31303211
Thermo 10uL SYR FN 50mm TGa 25 Cone Tip x 3
Part#: 3650525
Thermo Stand Outfit PTV/LV Trace
Part#: 27520124
Thermo Stand Outfit PTV
Part#: 27520101
Thermo Graphite Vespel Ferrule For 0.1-0.25 Pk 10
Part#: 29033498
Thermo Ferrule Cap Graph 0.45mm Pk 10
Part#: 29053487
DSQ II Manuals and Methods Rev B CD
Part#: 120315-CDMANS
Thermo Injection lINER, th 3mmID 105mm Pk 5
Part#: 45350032
Thermo Liner TQ(CE) 5mmID S/Less Mod Foc pk 5
Part#: 453T2999
Thermo Injection Liner Th 5mmID 105mm Pk 5 x 2
Part#: 45350033
£ 1,425.00 (ex. VAT) 1 in stock
Costech Instruments Elemental Combustion GC Gas Chromatography System ECS4010
ITEM-24332
This Costech Instruments Elemental Combustion GC Gas Chromatography System ECS4010 was removed from a university lab where it was surplus to requirements.
The item powers on but has not been tested any further. The lab it was removed from did inform us that most of the equipment removed from the particular lab was in working order.
The item is mostly in a reasonable, used cosmetic condition but the right side panel is missing and the back panel is loose.
There is a manual included.
£ 1,335.00 (ex. VAT) 1 in stock
Hewlett Packard Series 6890 GC System with HP 6890 Series Injector
ITEM-24275
Hewlett Packard Series 6890 GC System with HP 6890 Series Injector
This was removed from a university lab where it was surplus to requirements.
The unit powers up and the oven works. It is in good cosmetic condition with minor marks.
Accessories
1 x N930-1358
1 x N930-1357
1 x Fused Silica Tube TSP020090
Micromass part - 6028621
1x Merlin Microseal septum replacement
Part Number - 310
1 x Restek Premium non-stick w/Center Guide 50 pack 48 left
item No - 27090
GC Liner for HP S/SL 1-Taper w/Wool
Part number - AG0-4680
Lot no - P01-C6616
1 x Restek Drilled Cyclo Uniliner Hole near top 4.0mmx6.3x78.5 for Agilent GCs
Lot - 824835C
Cat - 22980
Supelco Capillary Splitter HP-5890 Packed
£ 1,235.00 (ex. VAT) 1 in stock
Hewlett Packard 5890 Series II Gas Chromatograph GC System Lab
ITEM-38802
Hewlett Packard 5890 Series II Gas Chromatograph GC System
This was removed from a university lab where it was surplus to requirements.
All the units power up and are in reasonable cosmetic condition with marks from use.
Included are;
Agilent 6890 Series Injector
Model - 18593B
S/N - 3227G07221
Hewlett Packard 7673 Controller
Model - 18594B # 206+
S/N - 3302G07812
Hewlett Packard 5971A Mass Selective Detector
Model - 5971A
S/N - 2950A00496
Hewlett Packard 59822B Ionization Gauge Controller
Model - 01
S/N - 3996
Hewlett Packard 82937A HP-1B Interface
£ 1,200.00 (ex. VAT) 1 in stock
Hewlett Packard 5890 Series II Gas Chromatograph Lab
ITEM-38801
Hewlett Packard 5890 Series II Gas Chromatograph
This was removed from a university lab where it was surplus to requirements.
The system all powers up but has not been tested further.
Hewlett Packard 5890 Series II Gas Chromatograph
Model - 5890 A Series II
Agilent 6890 Series Injector
Model - 18593B
Hewlett Packard 7673 Controller
Model - 18594B # 403
Hewlett Packard 5971A Mass Selective Detector
Model - 5971A
£ 1,185.00 (ex. VAT) 1 in stock
HP Agilent 6890 G1530A GC Gas Chromatography System Lab
ITEM-28235
This HP Agilent 6890 G1530A GC Gas Chromatography System was removed from a university lab where it was surplus to requirements.
All parts connect together and power on.
The lab confirmed that though the system hadn't been used for a number of years but was in working order prior to being put in storage.
Included are;
1 x ALS Ready G1530A
1 x HP 7683 Series Injector
G2613AX
1 x PDZ Europa Orchid Preparation Module
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 950.00 (ex. VAT) 1 in stock
Hewlett Packard HP 6890 GC Gas Chromatograph & Agilent 6890 Series Injector Lab
ITEM-18974
Hewlett Packard HP 6890 GC Gas Chromatograph & Agilent 6890 Series Injector
This was removed from a university lab where it was surplus to requirements.
The unit has had the mains power board removed and is sold for spares/repairs.
It is in reasonably good cosmetic condition but has some marks from use.
£ 645.00 (ex. VAT) 1 in stock
Varian 430-GC Gas Chromatograph With CP-8400 Autosampler Lab
ITEM-19311
Varian 430-GC Gas Chromatograph With CP-8400 Autosampler
These were removed from a university lab where they were surplus to requirements.
The unit is in good cosmetic condition but has some marks from use.
The GC powers up and the oven heats. We however couldn't seem to get the autosampler to work despite it being connected up. It was not tested further. The lab manager informed us that the unit was working when it was last used, though this was over a year ago.
The system also comes with Galaxie software discs, manuals and some spares.
£ 500.00 (ex. VAT) 1 in stock
CSi 200 Series Gas Chromatography System 20520130 Lab
ITEM-32076
This CSi 200 Series Gas Chromatography System was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
Type: 20520130
S/N 979071
Item is in good, used condition and powered up without issue.
With it are;
2x Operating Manuals
2x SGE
3x Packs of 10 Graphite Ferrules:
P/N 072624 OGF-PE-8/005
1x Pack of 10 Graphite Ferrules:
P/N 072621 OGF4-4-Graph
1x Pack of 50:
P/N 041842 7mm TCS SEPTA
1x Pack of 25:
P/N 041882 7mm AUTO-SEP T 11mm
1x Pack of 50:
P/N 041825 10mm CS SEPTA
1x Pack of 25:
P/N 041871 AUTO-SEP 9.5mm
£ 495.00 (ex. VAT) 1 in stock
Lot of HP & Agilent Chromatograph Circuit Boards Lab
ITEM-38796
Lot of HP & Agilent Chromatograph Circuit Boards
The units are untested.
Included are;
- 1 X HP 5890 10245-60015 Gas Chromatograph Electronic Pressure Control Board
- 1 X HP E2071/82341 ISA Interface Card E2073-66501 HPIB GPIB Board
- 2 X Agilent HP 5890A 5890 II GC ECD Electron Capture Detector Board 19233-60015
- 1 X Agilent HP 19257-60015 & 19257-60020 5890 Series II HPIB GPIB
- 1 X Berger SFC Minigram Circuit Boards STI460093684, 40200G9D6, 19257-60505
- 3 X HP Agilent SERIES II GAS CHROMATOGRAPH 5890 Keypad 05890-60740
- 2 X Agilent HP 5890 GC II 120V Single Phase Power Supply 05890-60050 Chromatograph
£ 485.00 (ex. VAT) 1 in stock
Varian CP-3800/3380 Gas Chromatograph GC System & Model 8400 Autosampler Lab
ITEM-16992
This Varian CP-3800/3380 Gas Chromatograph GC System & Model 8400 Autosampler was removed from a university lab where it was surplus to requirements.
The information plate suggests this system was built in 2004.
The GC powered on and completed self-calibration with no issues. The oven was tested at 200C and measured at that with our digital thermometer (thermometer not included in the sale). The autosampler also powered on with the main unit and went through self-calibration. It was not tested further.
It is in good condition with only minor marks from use.
£ 275.00 (ex. VAT) 1 in stock
Hewlett Packard 5890 Series II Gas Chromatograph Lab
ITEM-28242
This Hewlett Packard 5890 Series II Gas Chromatograph was removed from a university lab where it was surplus to requirements.
The unit powers up and passes self-tests. It is in reasonably good cosmetic condition but has some minor marks from use.
There is a PC with it running Turbochrom software which likely has nothing to do with the GC but has interfaces on the back that match.
£ 260.00 (ex. VAT) 1 in stock
Hewlett Packard 5890 Series 2 GC Gas Chromatograph Lab
ITEM-18977
This Hewlett Packard 5890 Series 2 GC Gas Chromatograph was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in reasonably good cosmetic condition but has some marks from use.
£ 245.00 (ex. VAT) 1 in stock
Hewlett Packard Gas Chromatograph 19256A System 5890 Series II with Injector Lab
ITEM-20247
This was removed from a university lab where it was surplus to requirements.
The unit powers on and is in good cosmetic condition. The oven works and the fan is working. The temperature reached 63˚C on the display. We could not get the autosampler or injector to do anything in testing as it appears the control unit is missing.
Dimensions:
L51cm x W86 x H88cm
Interior dimensions:
D14cm x W31cm x H28cm
Items 1 to 20 of 34