Electrophoresis
Items 1 to 16 of 16
£ 12,000.00 (ex. VAT) 1 in stock
Lonza 4D-Nucleofactor Electroporation System Core & X Units Lab
ITEM-48953
Lonza 4D-Nucleofactor Electroporation System Core & X Units Lab
This system was removed from a facility where it was surplus to requirement.
Both units are in very good cosmetic condition and power on. The previous owner stated it was in good working order prior to removal.
The system includes;
- Lonza 4D-Nucleofactor Core Unit
- Lonza 4D-Nucleofactor X Unit
£ 8,000.00 (ex. VAT) 1 in stock
Agilent 7100 CE Capillary Electrophoresis System G7100A
ITEM-50991
Agilent 7100 CE Capillary Electrophoresis System G7100A
This system was removed from a facility where it was surplus to requirements.
The unit is in good cosmetic condition. It powers on and begins its initialisation sequence; the internal wheel moves, the syringes perform their calibration routine, and the internal lights illuminate as expected.
We are unable to test the system further at our facility.
The previous owner has advised that the unit was in working order prior to removal.
£ 3,000.00 (ex. VAT) 1 in stock
Beckman Coulter P/ACE MDQ Capillary Electrophoresis System Lab
ITEM-47642
Beckman Coulter P/ACE MDQ Capillary Electrophoresis System
This system was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on, the previous owner stated it was in working order prior to decommissioning.
Includes:
- National Instruments GPIB-USB-HS (Model: GPIB-USB-HS, Serial No.: 152DFC7)
- PC running Windows XP Professional Version 2002 Service Pack 3 with the following software:
- Xcalibur 2.0.7 SP1 (Aug 12 2008)
- Mos_ProtCluster
- 32 Karat Software Version 8.0 Build 825
Model: P/ACE MDQ Capillary Electrophoresis System
Serial No.: 3061077
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 3,000.00 (ex. VAT) 1 in stock
ProteinSimple Wes Western Blot Protein Analyser System S/R
ITEM-48805
ProteinSimple Wes Western Blot Protein Analyser System (S/R)
This item was removed from a university where it was surplus to requirements.
It is in good cosmetic condition and powers on, however, we are unable to test it further at our facility.
An engineer inspection identified a possible SSD failure. The unit is being sold as Spares/Repair.
Please note; There is no PC or Software included.
£ 2,500.00 (ex. VAT) 1 in stock
Agilent 2100 Bioanalyzer G2939B w/ HP Laptop & Software (2021) Lab
ITEM-51370
Agilent 2100 Bioanalyzer G2939B w/ HP Laptop & Software (2021) Lab
This item was removed from a university where it was surplus to requirement.
It is in excellent cosmetic condition and powers on, we are unable to test it further at our facility.
The previous owner stated it was in working order prior to removal.
Includes;
- HP Pro Book w/ Agilent Technologies 2100 Bioanalyzer 2100 Expert Version B.02.11.SI824 (SR1) Software installed.
£ 1,450.00 (ex. VAT) 1 in stock
BTX Harvard Apparatus ECM 830 Electro Square Porator
ITEM-50863
BTX Harvard Apparatus ECM 830 Electro Square Porator
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Includes;
- Platinum plated 3mm TweezerTrodes (Catalog No. 45-0487).
£ 800.00 (ex. VAT) 1 in stock
Agilent 2100 Bioanalyser G2938C Lab
ITEM-49751
Agilent 2100 Bioanalyser G2938C Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
£ 555.00 (ex. VAT) 1 in stock
Amersham Biosciences Model TE 77 ECL Semi-Dry Transfer Unit Lab
ITEM-42639
Amersham Biosciences TE 77 ECL Semi-Dry Transfer Unit
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition. The unit is untested as the relevant power supply is not included.
Includes:
- Bio-Rad PowerPac Adaptor 4mm (Part No. 164-5064)
Specifications:
- Serial No.: 20150562
- Year: 2011
£ 500.00 (ex. VAT) 1 in stock
Sebia Hydrasys Focussing Agarose Gel Electrophoresis System w/ Accessories Lab
ITEM-48948
Sebia Hydrasys Focussing Agarose Gel Electrophoresis System w/ Accessories Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it further at our facility.
Accessories:
- Hydrasys Programmer and Key Card
- 5 x Hydragel 7 ISO-PAL Plastic Mask (55 x 42 mm)
- 5 x Thin Filter Paper (Green) (52 x 83 mm)
- 3 x Thick Filter Paper (Orange) (52 x 83 mm)
- 2 x Thin Filter Paper (Pink) (83 x 103 mm)
- 8 x Gel Support Cards
- 1 x Applicator Electrode Carrier (REF 1279)
- 2 x Casting Trays
- 3 x Boxes of Gel Combs of varying sizes
- 2 x Accessory Kit (REF 1251)
£ 500.00 (ex. VAT) 1 in stock
Ingeny PhorLI IPU-S Vertical Electrophoresis System
ITEM-37755
INGENYphorU IPU-S Vertical Electrophoresis System
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition with marks from use.
The unit is watertight and the valve is working.
Also included:
FisherBrand HU13
FisherBrand HU6
INGENY phorLI
Deca Probe Series
Invitrogen Novex Mini-Cell
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Agilent 2100 G2939A Bioanalyzer System & DNA Chips Spares/Repair Lab
ITEM-48419
Agilent 2100 G2939A Bioanalyzer System & Accessories Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and powers on, however it could not be fully tested as two channels show high leakage currents.
Therefore, it is being sold as spares or repair.
Includes:
- 1 box x High Sensitivity DNA Chips (5 in box) – expires Jan 2026
- 1 box x High Sensitivity DNA Chips (10 in box) – expires Jan 2026
- 1 box x Electrode Cleaners (5 in box)
- 1 box x Chip Priming Station
- 1 x Bayonet Electrode Cartridge (in blue case)
- 1 box x 11 Syringe Kits
- 1 box containing Test Chip Kit/Electrode/Diode Test Chip & USB 2.0 Cable
Model: 2100 Bioanalyzer
Serial No.: DE13805731
Product No.: G2938C
£ 450.00 (ex. VAT) 1 in stock
Bio-Rad CHEF-DR III Pulsed Field Electrophoresis System, 1703649, Cooling Mod
ITEM-43140
Bio-Rad CHEF-DR III Pulsed Field Electrophoresis System
This item was removed from a facility where it was surplus to requirement.
The system powers on and is in good cosmetic condition with minimal wear. We are unable to test it further at our facility.
Bio-Rad CHEF-DR III
- Model: CHEF-DR III Power Module
- S/N: 962BR 2172
Bio-Rad Electrophoresis Cell
- Model: 1703649
- S/N: 275BR 020466
Bio-Rad Variable Speed Pump
- Model: Variable Speed Pump
- S/N: 260BR 09531
Bio-Rad Cooling Module
- Model: Cooling Module (Non-CFC)
- S/N: 816BR 5050
£ 255.00 (ex. VAT) 1 in stock
Life Technologies Model iBlot 2 Gel Transfer Device
ITEM-43034
Life Technologies iBlot 2 Gel Transfer Device
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and in good working order.
Includes:
- Firmware Version: 1.3.0
Model: iBlot 2 Gel Transfer Device
Serial No.: 031051632
£ 250.00 (ex. VAT) 1 in stock
Thermo Electron SG210D SG210DR-230 SpeedGel Gel Dryer Lab
ITEM-45255
Thermo Electron SG210D Gel Dryer
This item was removed from a university lab where it was surplus to requirements.
The unit powers on and is in good working order.
It is in good cosmetic condition.
Included:
- 2 x Sealed disposable cartridges for Thermo Electron Chemical Trap
Specifications:
- Model: SG210D
£ POA 1 in stock
Invitrogen Neon Electroporator Transfection System MPK5000
ITEM-52669
Invitrogen Neon Electroporator Transfection System MPK5000
This system was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
The previous owner stated it was in working order prior to removal.
£ POA 1 in stock
Agilent 2100 Bioanalyzer w/ Software, Test Chips, Tubing & Fittings
ITEM-51569
Agilent 2100 Bioanalyzer Product No. G2938C
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Includes;
- Agilent 2100 Bioanalyzer Expert Software CD
- Agilent 2100 Bioanalyzer Software & User Information booklet
- Agilent Software Kit (2x)
- Agilent Software Certificate & Registration Packet – 2100 Instrument Control License
- Agilent Software Certificate & Registration Packet – 2100 Electrophoresis License
- Agilent 5065-4413 Bayonet Electrode Cartridge
- Agilent Electrode/Diode Test Chip
- Agilent Antifouling Test Chip
- Agilent flow cell cartridge
- Agilent fuse
- Rephodyne fittings kit (P/N 5512780)
- Millipore spare fitting set
- IDEX / Upchurch Scientific fittings pack
- RedOpine optical discs
- Assorted Agilent capillary tubing coils
- Assorted clear laboratory tubing
- Assorted microfluidic connectors and ferrules
- Assorted compression fittings
- Assorted threaded couplers
- Bag of small black connector covers / caps
- Small Agilent labelled spare parts packet
- Additional loose fluid connectors and fittings pack
Items 1 to 16 of 16