Our Floor Standing Centrifuges category offers a selection of high-quality, second-hand centrifuges designed for high-capacity applications in research, clinical, and industrial environments. These powerful units are ideal for handling large sample volumes, making them perfect for cell pelleting, protein purification, and other large-scale separations.


Equipment undergoes varying levels of testing, including functionality checks and rotor performance assessments, ensuring reliable and efficient centrifugation. Ideal for laboratories and industries requiring high throughput and precise sample processing.

Items 1 to 36 of 36

Image of Beckman Coulter Optima XPN-100K Ultracentrifuge Lab

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 27,500.00 (ex. VAT) 1 in stock

Beckman Coulter Optima XPN-100K Ultracentrifuge Lab

ITEM-41124

Beckman Coulter Optima XPN-100K Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in very good cosmetic condition and full working order.


It has been professionally serviced, the full report is available on request.


This item was tested with an in-house rotor (Beckman 70.1Ti). This rotor is not included in the sale.

Image of Beckman Optima L-100 XP Ultracentrifuge Lab

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 12,500.00 (ex. VAT) 1 in stock

Beckman Optima L-100 XP Ultracentrifuge Lab

ITEM-36931

Beckman Optima L-100 XP Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It has been professionally serviced, is in full working order, and is in good cosmetic condition.


The full report is available on request.


Also includes:


1 x Service Book


1 x Log Book


4 x Foot Plates

Image of Beckman Coulter Optima L-100 XP Ultra Centrifuge Lab

£ 12,250.00 (ex. VAT) 1 in stock

Beckman Coulter Optima L-100 XP Ultra Centrifuge Lab

ITEM-45138

Beckman Coulter Optima L-100 XP Ultra Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition with minimal signs of general use.

The unit reached its maximum rotor speed of 32,000 rpm quickly and consistently, and temperature testing confirmed it reached both 0ºC and 37ºC without issues.


The lab confirmed it was in good working order prior to removal


Specifications:

  • Model: Optima L-100 XP
  • Rotor Max Speed: 32,000 rpm
  • Temperature Range Tested: 0ºC to 37ºC

In good working condition with efficient rotor and temperature functionality.

Image of Beckman Optima XL100K Ultracentrifuge w/ Sorvall AH-629 & RPS40T-832 Lab

£ 10,000.00 (ex. VAT) 1 in stock

Beckman Optima XL100K Ultracentrifuge w/ Sorvall AH-629 & RPS40T-832 Lab

ITEM-41835

Beckman Optima XL100K Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and in good working order.


Also includes the following:


Sorvall AH-629 Rotor


RPS40T-832 Rotor


Neither rotor includes the vial buckets.

Image of Beckman Optima XL-100K Ultracentrifuge & 70 ti Rotor Lab

£ 9,850.00 (ex. VAT) 1 in stock

Beckman Optima XL-100K Ultracentrifuge & 70 ti Rotor Lab

ITEM-37205

Beckman Optima XL-100K Ultracentrifuge Lab

CAT no. 365669

Serial no. COX97D02


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and in good working order when tested on-site, the previous client has also stated it was in working order prior to removal.


There is no rotor included.

Image of Cepa Z-41 High Speed Centrifuge

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 8,000.00 (ex. VAT) 1 in stock

Cepa Z-41 High Speed Centrifuge

ITEM-41154


Cepa Z-41 High Speed Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up and is in working order. It runs on a timer delay so takes a few moments to start working.


It is in good cosmetic condition.

Image of Beckman Coulter Optima L-90K Ultracentrifuge Lab

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 4,550.00 (ex. VAT) 1 in stock

Beckman Coulter Optima L-90K Ultracentrifuge Lab

ITEM-35051

Beckman Coulter Optima L-90K Ultracentrifuge


This was removed from a university lab where it was surplus to requirements.


The unit has been professionally serviced and is in good working order. A full report is available on request.


It is in good cosmetic condition with minor marks.

Image of Beckman Optima L-90K Ultracentrifuge Lab

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 4,500.00 (ex. VAT) 1 in stock

Beckman Optima L-90K Ultracentrifuge Lab

ITEM-35050

Beckman Optima L-90K Ultracentrifuge Lab


This was removed from a university lab where it was surplus to requirements.


The unit has been professionally serviced, it is in full working order, and the full report is available on request.


It is in good cosmetic condition with minor marks.


A rotor is not included.


Image of Sorvall Evolution RC Floor Standing Centrifuge w/ Sorvall SLA-1500 Lab

£ 4,500.00 (ex. VAT) 1 in stock

Sorvall Evolution RC Floor Standing Centrifuge w/ Sorvall SLA-1500 Lab

ITEM-45551

Sorvall Evolution RC Floor Standing Centrifuge w/ Sorvall SLA-1500 Super-Lite Autoclavable Rotor


This item was removed from a university laboratory where it was surplus to requirements.


The centrifuge powers on and is in good cosmetic condition. Temperature and RPM testing were conducted successfully.


Temperature Testing :

  • Set to -20.0ºC, stabilized at -18.0ºC
  • Set to 37.0ºC, stabilized at 37.0ºC
  • Set to 40.0ºC (max), stabilized at 40.0ºC

RPM Testing:

  • Held steady at 15,000 RPM

Included Rotor:

  • Sorvall SLA-1500 Super-Lite Autoclavable Rotor (max 121ºC)
  • In good cosmetic condition

Image of Beckman Coulter Optima L-80 XP Ultra Centrifuge Lab

£ 4,500.00 (ex. VAT) 1 in stock

Beckman Coulter Optima L-80 XP Ultra Centrifuge Lab

ITEM-37218

Beckman Coulter Optima L-80XP


This item was removed from a university laboratory where it was surplus to requirements.


The unit was tested at the rotor maximum of 32,000 rpm, reaching this speed quickly and without issue.

Temperature testing confirmed stable operation, achieving both the minimum temperature of 0ºC and 37ºC as expected.


In good cosmetic and mechanical condition, with verified speed and temperature control functions.


Includes:

  • Tested with rotor model SW 32 Ti (Not included)

Specifications.

  • Model: Optima L-80XP
  • Serial No.: LXP11H01

Image of Beckman Coulter Avanti J-E Centrifuge

£ 3,820.00 (ex. VAT) 1 in stock

Beckman Coulter Avanti J-E Centrifuge

ITEM-35784

This Beckman Coulter Avanti J-E Centrifuge was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further as we do not have a compatible rotor in stock. We think it requires a rotor with a magnet fitted.


It is in good cosmetic condition with minor marks.

Image of Beckman Optima LE-80K Ultracentrifuge w/ Beckman SW 41 Ti Rotor Lab

£ 3,000.00 (ex. VAT) 1 in stock

Beckman Optima LE-80K Ultracentrifuge w/ Beckman SW 41 Ti Rotor Lab

ITEM-41838

Optima LE-80K Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and in good working order.


It has been temperature-tested and tested to the rotors maximum of 40,000rpm.


Also included are the following:


Beckman SW 41 Ti Rotor w/ 6 x Swinging buckets.

Image of Sorvall Discovery 90 SE Floor-Standing Centrifuge Lab

£ 3,000.00 (ex. VAT) 1 in stock

Sorvall Discovery 90 SE Floor-Standing Centrifuge Lab

ITEM-37194

Sorvall Discovery 90 SE Floor-Standing Centrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, it has been tested at 70,000rpm using a Beckman 70.1Ti rotor.


The rotor is not included.

Image of  Beckman Coulter Optima LE-80K Ultracentrifuge with Rotor   Lab

£ 3,000.00 (ex. VAT) 1 in stock

Beckman Coulter Optima LE-80K Ultracentrifuge with Rotor Lab

ITEM-36506

This  Beckman Coulter Optima LE-80K Ultracentrifuge was removed from a university lab where it was surplus to requirements.


The unit powers up and is in good working order.


It is in good cosmetic condition with minor marks.


Included with it are;


1x Beckman Coulter 6 bucket SW 28 Rotor

Max RPM: 28000


6x Beckman Coulter SW 28 swinging buckets/50 ml tube adapter


1x Beckman Coulter rotor bag


4x Boxes of Beckman Coulter Pollyallomer Centrifuge Tubes 14 x 89 mm


2x Boxes of Beckman Coulter Ultra-Clear Centrifuge Tubes 25 x 89 mm


1x Beckman Coulter Spincote Lubricant


1x Beckman Coulter Silicone Vacuum Grease


1x Beckman Coulter Release tool


1x Beckman Coulter Rotor Safety Manual


1x Beckman Coulter Rotors and Tubes instruction CD


Image of Beckman Avanti Model J-25 Refrigerated Centrifuge Lab

£ 2,500.00 (ex. VAT) 1 in stock

Beckman Avanti Model J-25 Refrigerated Centrifuge Lab

ITEM-36881

Beckman Avanti Model J-25 Refrigerated Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a JA20 rotor (Not included). It worked well up to the tested speed of the rotor's max of 20,000rpm. The refrigeration works well.


It is in reasonably good cosmetic condition with some minor marks.





Image of Sorvall Discovery M150 SE Centrifuge w/ S140-AT Fixed Angle Titanium Rotor Lab

£ POA 1 in stock

Sorvall Discovery M150 SE Centrifuge w/ S140-AT Fixed Angle Titanium Rotor Lab

ITEM-44516

This item is new in stock. Please enquire for further details.

Image of Beckman J6-MC Centrifuge with Beckman Coulter JS-4.2 Rotor Lab

£ 1,750.00 (ex. VAT) 1 in stock

Beckman J6-MC Centrifuge with Beckman Coulter JS-4.2 Rotor Lab

ITEM-42125

Beckman J6-MC Centrifuge with JS-4.2 Rotor and Buckets


This item was removed from a university where it was surplus to requirement.


The centrifuge is in good cosmetic condition with minimal wear.


The unit powers up and is in good working order (thermometer not included).

It has been tested to its maximum rotor speed of 4200 RPM.


Specifications:

  • Model: J6-MC
  • Serial No.: NJF96L04

Includes the following:


Rotor:

  • Model: JS-4.2
  • Serial No.: 14E 1970
  • Date of MFG: 2014
  • Max RPM: 4200 RPM

Buckets:

  • Quantity: 6
  • Type: Beckman Coulter JS-3.0/JS-4.2/JS-4.2A
  • Weight: 1061 grams each
  • Max RPM: 4200 RPM
  • Date of MFG: 2014

Image of Beckman Centrifuge  Model - J2-21 with JA-10 10000rpm Rotor Lab

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 1,285.00 (ex. VAT) 1 in stock

Beckman Centrifuge Model - J2-21 with JA-10 10000rpm Rotor Lab

ITEM-26288

This Beckman Centrifuge Model - J2-21 Cat no. 341737 with JA-10 10000rpm Rotor was removed from a university lab where it was surplus to requirements.


The centrifuge has been professionally serviced and is in full working order. There is a full report available on request.


Included are manuals for the centrifuge & rotor along with some O-Rings for the JA-10.


Rotor Type - JA-10

SN - E 20994

6 X 500ml Slots

Image of Sorvall Discovery 100SE Refrigerated Floor Standing Centrifuge Lab Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,250.00 (ex. VAT) 1 in stock

Sorvall Discovery 100SE Refrigerated Floor Standing Centrifuge Lab Spares/Repair

ITEM-29790

Sorvall Discovery 100SE


This was removed from a university lab where it was surplus to requirements.


The unit is missing the power switch and the cable is split. It looks like some other parts have been removed and cables have been disconnected inside.


It is in otherwise reasonable cosmetic condition with minor marks from use. The rear panel is showing signs of damage.


It is sold for spares/repairs.

Image of Beckman J2-21 Floor Standing Centrifuge with JA10 10000rpm Rotor Lab

£ 1,245.00 (ex. VAT) 1 in stock

Beckman J2-21 Floor Standing Centrifuge with JA10 10000rpm Rotor Lab

ITEM-32037

Beckman J2-21 Floor Standing Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order. It is in good cosmetic condition with only minor marks from use.


Included are;


Beckman J2 - 21 Centrifuge

Cat no. 341737

SN - E948


Rotor Type - JA 10

SN - 17342

10,000rpm Max

Hold 6 x Buckets 7cm diameter




Image of Beckman Coulter Avanti J-E Centrifuge  Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,185.00 (ex. VAT) 1 in stock

Beckman Coulter Avanti J-E Centrifuge Lab Spares/Repairs

ITEM-29745

Beckman Coulter Avanti J-E Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up but has several faults. The unit requires a new board, flash card and cooling system.


It is in good cosmeti condition with minor marks.


It is sold for spares/repairs.

Image of Beckman Centrifuge  Model - J2-21 Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,000.00 (ex. VAT) 1 in stock

Beckman Centrifuge Model - J2-21 Spares/Repairs

ITEM-26290

This Beckman Centrifuge Model - JS-21 Cat no. 341737 was removed from a university lab where it was surplus to requirements.


The unit powers up but has a fault with the shaft and bearings.


It is sold for spares/repairs.

Image of Beckman Coulter Avanti J-HC Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,000.00 (ex. VAT) 1 in stock

Beckman Coulter Avanti J-HC Centrifuge Lab Spares/Repairs

ITEM-31551

Beckman Coulter Avanti J-HC Centrifuge


This item was removed from a university lab where it was surplus to requirements.


The centrifuge is in good cosmetic condition and powers on. However, due to an imbalance issue, no further testing could be conducted.


The spindle is bent.


Therefore, it is listed as Spares/Repair.

Image of BECKMAN Model J2-21 Floor Standing Centrifuge Lab

£ 950.00 (ex. VAT) 1 in stock

BECKMAN Model J2-21 Floor Standing Centrifuge Lab

ITEM-21249

This BECKMAN Model J2-21 Floor Standing Centrifuge was removed from a university lab where it was surplus to requirements.


The unit is in full working order but is not supplied with a rotor.


It is in reasonably good cosmetic condition but has cracks on the door hinge and latch.


Image of Beckman   Refrigerated Centrifuge Spares/Repairs Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 900.00 (ex. VAT) 1 in stock

Beckman Refrigerated Centrifuge Spares/Repairs Lab

ITEM-37628

Beckman L7-65 Refrigerated Centrifuge L7-65R


This was removed from a university lab where it was surplus to requirements.


The unit powers up and will run to 1500rpm, but it cannot create a sufficient vacuum to run at higher speeds.


For this reason it is sold for spares/repairs.

Image of Thermo Scientific Sorvall Discovery M120 SE Centrifuge Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 800.00 (ex. VAT) 1 in stock

Thermo Scientific Sorvall Discovery M120 SE Centrifuge Spares/Repairs

ITEM-35813

This was removed from a university lab where it was surplus to requirements


THe unit powers up but shows error 48 which is a door lock error. It seems like the door solenoid is not being sent a signal.


It is sold for spares/repairs.


No rotor included.

Image of Sorvall OTD-COMBI Ultracentrifuge w/ Sorvall T-865.1 Rotor Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 750.00 (ex. VAT) 1 in stock

Sorvall OTD-COMBI Ultracentrifuge w/ Sorvall T-865.1 Rotor Spares/Repair Lab

ITEM-41834

Sorvall OTD-COMBI Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on. However, the door unlock switch is non-functional, therefore, preventing the unit's ability to lock or open the door.


We were able to open it manually, but the automatic door open function is faulty.


Therefore, it is listed as Spares/Repair.


Also includes the following:


Dupont Instruments Sorvall T-865.1 Rotor.

Serial No: 9330329.


8 Hole rotor.

Tube dimensions: 1.5cm x 8cm.



Image of Sorvall RC-5C+ Plus Floorstanding Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 750.00 (ex. VAT) 1 in stock

Sorvall RC-5C+ Plus Floorstanding Centrifuge Lab Spares/Repairs

ITEM-41038

This Sorvall RC-5C Plus Floor-Standing Centrifuge was removed from a university lab where it was surplus to requirements.


The unit powers up, but shortly after running it produces error code 7 preventing it from being tested, therefore this item is sold as Spares or Repairs.


Error 7 = REFRIGERATION SYSTEM FAILURE There was no apparent drop in chamber temperature thirty seconds after the refrigeration system started to cool. Notify your Thermo Field Service Engineer.





Image of Beckman L7-65 Ultracentrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 750.00 (ex. VAT) 1 in stock

Beckman L7-65 Ultracentrifuge Lab Spares/Repairs

ITEM-29720

This Beckman L7-65 Ultracentrifuge was removed from a university lab where it was surplus to requirements.


The unit powers up and runs well, but the cooling system does not work.


It is in good cosmetic condition with minor marks.


It is sold for spares/repairs.


Image of Beckman L8-60MR Ultracentrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 700.00 (ex. VAT) 1 in stock

Beckman L8-60MR Ultracentrifuge Lab Spares/Repairs

ITEM-39709

Beckman L8-60MR Ultracentrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up and was tested with a Beckman 70.1 Ti rotor from another item (Not included), but would not reach over 3000rpm (Rotor max is 10000). We suspect there is a vacuum issue as the vacuum light flashed red during testing. The system also will not cool down.


It is in otherwise good cosmetic condition.


It is sold for spares/repairs.


Beckman L8-60MR Ultracentrifuge

Model: L8-60MR

Serial#: 6H816

Year: 1988


Image of Beckman J2-21 Floor Standing Centrifuge 20000rpm Max Lab

£ 630.00 (ex. VAT) 1 in stock

Beckman J2-21 Floor Standing Centrifuge 20000rpm Max Lab

ITEM-20251

This Beckman J2-21 Floor Standing Centrifuge was removed from a university lab where it was surplus to requirements.


We have replaced the lid and repaired an area of cracked plastic underneath it. It is very stable. There are some cracks around the gas strut area. They do not appear to affect the operation of the unit.


The unit is functional and has a comprehensive service history.


The centrifuge holds a vacuum well and has been tested at:


5,000rpm

10,000rpm

15,000rpm

20,000rpm (Max).


It ran fine at all these speeds but the needle isn't totally in sync with the control knob.


It has been tested at the following temperatures:


0ºC our thermometer read -15.8ºC

20ºC our thermometer read 21.2ºC


It appears to probably have a cooling issue. The compressor etc runs fine. It just appears to drop lower than it is set. When set to higher temps, it takes quite a while to heat up.


Image of Beckman Optima L-60 Floor Standing Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 600.00 (ex. VAT) 1 in stock

Beckman Optima L-60 Floor Standing Centrifuge Lab Spares/Repairs

ITEM-42198

Beckman Optima L-60 Floor Standing Centrifuge


This item was removed from a university lab where it was surplus to requirements.


The centrifuge powers on and is in good cosmetic condition.


However, during testing, the display read the following message:

"DRIVE", preventing it from running a cycle.


Therefore, it is listed as Spares/Repair.


There is no rotor included.


Specifications:

  • Speed: 1,000 - 60,000 rpm
  • Temperature: 0˚C - 40˚C

Model: Optima L-60

Serial No.: L1M602


Rotational Counter: 417,132 x 10,000 rotations

Image of Beckman Coulter Avanti J-25 Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Beckman Coulter Avanti J-25 Centrifuge Lab Spares/Repairs

ITEM-45508



Beckman Coulter Avanti J-25 Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


The centrifuge powers on and is in fair cosmetic condition. The condenser appears to be functional as the unit begins to cool, but a drive error is displayed on the centrifuge.

Upon inspection, it was found that the motor had been disconnected, the front panel removed, and most wiring disconnected.


This item is sold as-is for Spares/Repairs due to its current state.


Specifications:

  • Serial No.: 270-728845-AA
  • Model No.: Avanti J-25

Image of Beckman L8-80MW Ultracentrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Beckman L8-80MW Ultracentrifuge Lab

ITEM-44394

Beckman L8-80 Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition externally and powers on, however, when tested we attempted to run the unit with a 70Ti rotor (not included), but encountered cooling system and speed sensor errors.

Also, oil was discovered under the rotor and in the chamber/motor area, possibly due to a worn seal.


Due to the above faults, this item is listed as Spares/Repair.


The 3-phase plug has been removed and there is no rotor included in the sale.


Also included:


1 x Operation Key

1 x Original User Manual

Image of Beckman Coulter Avanti J-25 Centrifuge Lab

£ POA 1 in stock

Beckman Coulter Avanti J-25 Centrifuge Lab

ITEM-41342

This item is new in stock. Please enquire for further details.

Image of Beckman Coulter Optima LE-80K Ultracentrifuge

£ POA 1 in stock

Beckman Coulter Optima LE-80K Ultracentrifuge

ITEM-24728

This item is new in stock. Please enquire for further details.

Items 1 to 36 of 36

Filters

Price (£)

to

Condition

Brand

Category filters

Physical Specifications

Maximum RPM (RPM)

to

Minimum Temperature (ºC)

to

Maximum Temperature (ºC)

to

Zonal Capability