Items 1 to 20 of 21

Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 13,770.00 (ex. VAT) 1 in stock

Dionex UltiMate 3000 HPLC System - AXP - VWD-3100 - TCC-3000 SD - SRD-3600 Lab

ITEM-31761

This Dionex UltiMate 3000 HPLC System was removed from a university lab where it was surplus to requirements.


This system has been inspected and tested by a qualified engineer. As a whole the system has passed.


All modules that require software have been tested with Chromeleon v 6.8 and all modules communicate successfully.


This system comes with Chromeleon v 6.8 installed on a PC but does not include a license and dongle.


1x Thermo Dionex AXP Metering Auxiliary Pump

S/N Z0040311

Powers on - Tested 2.5ml to over 1000 psi working as should no leaks



1x Dionex UltiMate 3000 Variable Wavelength Detector VWD-3100

P/N 5074.0005

S/N 8022629

Powers on Status ok


1x Dionex UltiMate 3000 Pump LPG-3400 AB

P/N 5037.0015

S/N 8022830

Firmware 3.05

The system has been modified by a client from a quaternary to a binary pump. Pump tested at 2.5ml a minute, pressure steady at 12000psi, no leaks.

All ok


1x Dionex UltiMate 3000 SR-3000 Solvent Tray without Degasser

P/N 5035.9200



1x Dionex UltiMate 3000 SRD-3600 Solvent Tray with 6 Degasser channels

P/N 5035.9230

S/N 8019828

Powers on. Self-check ok. Status ok. Vacuum test pass.


1x Dionex UltiMate 3000 SRD-3600 Solvent Tray with 6 Degasser channels

P/N 5035.9230

S/N 1050601

Powers on. Self-check ok. Status ok. Vacuum test pass.

 

1x Dionex UltiMate 3000 Analytical Autosampler WPS-3000 T

P/N 5820.0020

S/N 1000605

Powers on. Self-check ok. Status ok.


1x Dionex UltiMate 3000 Column Compartment TCC-3000 SD

P/N5730.0010

S/N 8021955

Firmware 1.20. Passed all functions test. Both switching valves work. The temperature cools and heats as should. The temperature is stable


1x Dionex UltiMate 3000 Fraction Collector

S/N 12904 AFC 3000

Powers on. Connects with software. USB works but driver not present in the software


1 x Dionex UCI-50 Universal Chromatography Interface

P/N 5911.0005

S/N 8022442

Powers on.




Image of item

£ 7,500.00 (ex. VAT) 1 in stock

Agilent 1100 Series HPLC System G1316A, G1314A, G1313A, G1311A with Flex Cart

ITEM-38316

Agilent 1100 Series HPLC System G1316A, G1314A, G1313A, G1311A with Flex Cart


This system was removed from a university where it was surplus to requirement.


All units power up and are in good cosmetic condition, we are unable to conduct further testing at our facility.


The system was last serviced in September 2020 by an Agilent CrossLab engineer.


The system consists of the following:


Agilent 1100 Series Quat Pump

Product No. G1311A

Serial No. DE43629292


Agilent 1100 Series Autosampler

Product No. G1313A

Serial No. DE43627225


Agilent 1100 Series Thermostatted Column Compartment

Product No. G1316A

Serial No. DE4364238


Agilent 1100 Series Variable Wavelength Detector

Product No. G1314A

Serial No. JP43825280


Waters Acquity Flex Cart


Phenomenex ThermaSphere Column Heater

Model TS-130

Serial No. 11021018


4 x power leads


1 x 12v transformer for the column heater


1 x data cable

Image of item

£ 6,905.00 (ex. VAT) 1 in stock

Thermo Scientific Accela HPLC System - PDA Detector, 1250 Pump, Autosampler Lab

ITEM-29792

This Thermo Scientific Accela HPLC System was removed from a university lab where it was surplus to requirements.


The system powers up but has not been tested further at our facility.


The system is in very good cosmetic condition with only minor marks from use.


Included are;


1 x Thermo Scientific Accela PDA Detector.

1 x Thermo Scientific Accela Autosampler.

1 x Thermo Scientific 1250 Pump.

Set of Accessories

Image of item

£ 3,600.00 (ex. VAT) 1 in stock

Shimadzu Prominence HPLC System - DGU-20A5 - LC20-AT - SPD-20A w/ Software Lab

ITEM-36712

Shimadzu Prominence HPLC System - DGU-20A5 - LC20-AT - SPD-20A w/ Software


This was removed from a university lab where it was surplus to requirements.


The system is working but we were told that is has been unused for the past 2-3 years but does have all the required accessories and software. It can be a bit temperamental and the last time it was used for teaching it was prone to air bubbles and occasional pressure problems, but likely just needs a service.


Included are;


Model - Reservoir Tray

Cat no. 228-45041-91

SN - L20304303756


Prominence Degasser

Model - DGU-20A5

Cat no. 228-45019-32

SN - L20244301963

Powers on


Prominence Liquid Chromatograph

Model - LC-20AT

Cat no. 228-45001-38

SN - L20114370128

Powers on

Door doesn't close properly


Prominence UV/VIS Detector

Model - SPD-20A

Cat no. 228-45003-38

SN - L20134303055

Powers on

Door hinge is broken so it doesn't stay on


Manuals/Software:-

LabSolutions LCsolution Release 1.21 SP1

USB Dongle LCsolution Multi-LC (SN-L51254300014S7)

Shimadzu UV-1650PC Instruction Manual

Shimadzu User Authentication Tool Instruction Manual

Shimadzu Gradient Valve Kit for LC-20AD/20AT Installation Manual

Shimadzu HPLC LC Workstation Administration Manual

Shimadzu HPLC LC Workstation Operation Manual

Shimadzu LCsolution LC-Assist Version 2.1 Instruction Manual

Shimadzu LCsolution QCTool Manual

Shimadzu LCsolution Version 1.2 Software Release Notes

Shimadzu LCsolution Chromatography Data System Quick Manual

Shimadzu On-line Degasser DGU-20A3/DGU-20A5 Prominence Manual

Shimadzu Solvent Delivery Module LC-20AT Prominence Manual

Shimadzu UV/VIS Detector SPD-20A/SPD-20AV Prominence Manual


Mix of Syringes/Columns:-

Hichrom Inertsil ODS2

Hamilton Micro Syringe

2 x Hamilton 1002RN Syringe 2.5ml

Hamilton Rheodyne Valve 50ul Syringe

SGE Rheodyne Valve 50ul Syringe

Shimadzu Pathfiner HPLC Column


Other bits include:-

Raco case full of small parts including tubing, clamps, tools etc.


Image of item

£ 3,500.00 (ex. VAT) 1 in stock

HP HPLC System 1100 Series Lab

ITEM-25052

HP HPLC System 1100 Series


This was removed from a university lab where it was surplus to requirements.


The lab confirmed the system was working prior to removal.


Included are;


1x Vacuum Degasser

Pr No. G1322A

The unit powers up and is in good cosmetic condition.


1x Quat Pump

Pr No. G1311A

The unit powers up and is in good cosmetic condition.


1x ALS

Pr No. G1313A

The unit powers up and is in good cosmetic condition.


Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 3,000.00 (ex. VAT) 1 in stock

Agilent 1100 Series HPLC System Liquid Chromatography Lab Spares/Repairs

ITEM-37945

Agilent 1100 Series HPLC System Six Units Liquid Chromatography


This was removed from a university lab where it was surplus to requirements.


All system elements power up but have issues. We believe the system is spares/repairs.


The binary pump powered on with cooling fan operating and orange status light showing, indicating the unit was waiting for a condition to be met or an input. Metal pipe connectors may be missing as there are two empty threaded connectors on pump head.


The degasser powered on with cooling fan operating and pump heard to be running and orange status light showing, indicating the unit was waiting for a condition to be met or an input.


The Auto sampler thermostat has no power button or status light, it is controlled through the autosampler and could not be tested.


The Column compartment powered on with an orange status light showing for several second and it then changed to red indicating a fault.


The Autosampler powered on with fan operating and the injector arm moved in all directions as a self test, orange status light initially then changed to red indicating a fault. Small parts may be missing as a loose screw and small clamp were found loose inside.


THe diode array detector powered on with red status light showing indicating a fault. It was noted that the detector head has been removed and other smaller parts may be missing.



Included are;


Agilent G1312A Binary Pump

Serial No. DE72001469


Agilent G1379A Degasser

Serial No. JP13209325


Agilent G1330A ALSTherm autosampler thermostat

Serial No. DE82203268


Agilent G1316A Colcom column compartment

Serial No. DE03018210


Agilent G1329A ALS autosampler

Serial No. DE91603268


Agilent G1315A DAD diode array detector

Serial No. DE72002598


Agilent Solvent Tray

Image of item

£ 3,000.00 (ex. VAT) 1 in stock

Waters HPLC System - PC2, TC2, 515, 2767, APC & Accessories Lab

ITEM-26041

This system was removed from a university lab where it was surplus to requirements.


All units power up but this has not been tested further as a system.


It is in reasonably good cosmetic condition with marks from use.


Included are;


1x Waters Pump Control Module II

Model: PC2

S/N: K05PC2 650E


1x Waters Temperature Control Module II

Model: TC2

S/N: H05TC2 641E


1x Waters 515 HPLC Pump

Model: 515

S/N: L05515 088A


1x Waters Column Fluidics Organizer

Model: APC

S/N: K05APC 452M


1x Waters 2767 Sample Manager

Model: 2767 SAMPLE MGR.

Part no: 725000299

S/N: H05XY6 738M

Sample tubes fit 16ml vials.


1x Samsung Monitor

Model: 171S S

S/N: GH17HJCTB07621N


1x AOC LCD Monitor

Model: LM520 A

S/N: T5GJ32AR05528


1x Fujitsu Siemens Mouse

1x Acer Mouse

1x Acer KB-0759 Keyboard

1x BTC 5197 Keyboard


1x Applied Biosciences Programmable Absorbance Detector

Model: 785A

S/N: 29511519


1x IBM ThinkCentre PC

MT-M 8143-QGH

S/N: LMPM2TK

The hard drive has been removed from the PC.

We are certain it was paired up with Control Modules.


1x HP vw8400 WorkStation

S/N: CZC7113H1H

MassLynx

MassLynx Diversity

Sirius Analytical Instruments


1x Waters Column Heater Module

Model: CHM

S/N: M05CHM174M


1x Waters Leak Sensor Module


1x Gilson 506C System Interface Module

S/N: 369J8PA500


1x Waters Fraction Collector III Ver.W2.01

Model: WFC

S/N: D06WFC178J


1x Perkin Elmer Series 200 LC Pump

S/N: 291N 5110302


1x S-Video Mini-DIN 4-pin

1x RS-232C Serial Cable

1x Control Cable Assembly

1x SCSI I to SCSI II Cable

1x Drive Cable 25 Pin male/male


1x Waters 2525 Binary Gradient Module Installation & Maintenance Guide

1x Waters 2767 Sample Manager Injector Installation & Maintenance Guide

1x Waters 515 HPLC Pump Operator's Guide

1x Performance Maintenance Protocol 2007-2009

1x Waters Purification of Compounds - Using FractionLynx


Image of item

£ 2,910.00 (ex. VAT) 1 in stock

Hitachi Transgenomic Wave L-7000 Series DHPLC System - L-7400 - L-7300 Lab

ITEM-36234

Hitachi Transgenomic Wave L-7000 Series DHPLC System


This was removed from a university lab where it was surplus to requirements.


All units power up but have not been tested further as they require connection to a PC with software.


Included are;


Transgenomic/Hitachi L-7400 UV Detector

Model: L-7400

Part#: 810-0401

Serial#: 1147-080


Transgenomic/Hitachi L-7300 Column Oven

Model: L-7300

Part#: 810-0301

Serial#: 1153-014


Transgenomic/Hitachi L-7200 Auto Sampler

Model: L-7200

Part#: 810-0201

Serial#: 1154-136


Transgenomic/Hitachi L-7200 Chiller

Model: L-7200 ACC

Part#: 810-3301

Serial#: 1134-036


Transgenomic/Hitachi L-7100 Pump

Model: L-7100

Part#: 810-0101

Serial#: 1153-228


Transgenomic/Hitachi D-7000 Interface

Model: D-7000IF

Part#: 810-0091

Serial#: 1124-131


ERC Inc Hitachi L-761 Pump Drive Unit/Degasser

Model: L-761

Serial#: 102895N0775


Additional items included:


Transgenomic Wave Ineractive Help System CD

Part#: 6700002


Transgenomic Wave System Software Accessories CD

Part#: 6700006


Transgenomic Wave System Software Accessories CD

Part#: 6700005


Transgenomic Manual Binder x 2


Image of item

£ 2,510.00 (ex. VAT) 1 in stock

Perkin Elmer Series 200 HPLC System - Autosampler, Pump, Degasser, Peltier Lab

ITEM-39741

Perkin Elmer Series 200 HPLC System


This was removed from a university lab where it was surplus to requirements.


All elements of the system power up but it has not been tested further.


Included are;


Perkin Elmer Series 200 Diode Array Detector

Serial#: 292G0091513


Perkin Elmer Series 200 Peltier Oven

Serial#: OV1010315487


Perkin Elmer Series 200 Vacuum Degasser

Serial#: 5515


Perkin Elmer Series 200 LC Pump

Serial#: 291N1031902


Perkin Elmer Series 200 Autosampler

Serial#: 293N1033103


Dionex RF 2000 Fluorescence Detector

Part#: 5057/0020


Manuals/Software:

Perkin Elmer Turbo LC Plus Installation Guide

Perkin Elmer 600 Series LINK Interface Operators Manual

Perkin Elmer TotalChrom Workstation User's Guide Volume II

Perkin Elmer TotalChrom Workstation User's Guide Volume I

Perkin Elmer TotalChrom Tutorial

Perkin Elmer TotalChrom Application Manager's Guide

Perkin Elmer TurboChrom Application Manager's Guide

Perkin Elmer TotalChrom User's Guide

Perkin Elmer Series 200 Autosampler User's Manual

Perkin Elmer Series 200 Vacuum Degasser User's Manual

Perkin Elmer Turbo Method Development Tutorial for New User's

Perkin Elmer Series 200 Column Oven and Peltier Column Oven User's Manual

Perkin Elmer Series 200 LC Pump User's Manual

Perkin Elmer Series 200 Diode Array Detector II User's Manual

HPLC Troubleshooting Guide x2

Instrumental Liquid Chromatography Manual

Dionex Certificate of Compliance w/ Chromeleon Chromatography Management System CD

Various Product / Quality Certificates for all Perkin Elmer Systems

Perkin Elmer Kit SW Turbo Method Dev - S#: S270-1118

Perkin Elmer SW Tcws CD Kit - S#: S270-1210

Perkin Elmer OPT SW Turboscan 200 WS - S#: S270-0055

Perkin Elmer Series 200 Diode Array Detector V 2.3.2 - 12/00 CD

Perkin Elmer SW Turboscan - S#: 7720-0018 CD

Perkin Elmer Windows NT Repair Disk Floppy

Dell Creative Low End Cos Diags Floppy&CD

Roxio CinePlayer CD

Roxio Creator 10.1 LE

Oxford 95XE Series Driver CD


Parts/Accessories:

Beckman High Performance Columns - S#: 7UE617

MCI-GEL ProtEx DEAE Column 50mm x 4.6mm ID - S#: G8115

JonesChromatography HPLC Columns 3cm GENESIS C18 3u - S#: 8101228

JonesChromatography HPLC Columns Large No S#

USHIO Xenon Short Arc Lamp - S#: 6000722295

Dionex Syringe f. RF2000

ISCOVERY Guard Columns




Image of item

£ 2,255.00 (ex. VAT) 1 in stock

Agilent Technologies 1200 Series HPLC G1312A Binary Pump Lab

ITEM-38343

This Agilent Technologies 1200 Series HPLC G1312A Binary Pump was removed from a university lab where it was surplus to requirements.


The item is in good cosmetic condition and powered up, as seen the item is missing the front door panel.


We are unable to test this item further at our facility.


Power supply included.

Image of item

£ 2,180.00 (ex. VAT) 1 in stock

Perkin Elmer Series 200 HPLC System - 785A, 600, 950A, Lab

ITEM-35030

Perkin Elmer Series 200 HPLC System


This was removed from a university lab where it was surplus to requirements.


The system powered up but we were unable to test it further at our facility. It is in good cosmetic condition but has marks from use.


Included are as follows;


Perkin Elmer Series 200 Autosampler

Model#: 200 LC Autosampler

Serial#: 293N9022603


Perkin Elmer Series 200 Peltier Column Oven

Model#: Series 200 Peltier Column Oven

Serial#: 0VI000915343


Perkin Elmer 785A UV/VIS Detector

Model#: 785A/CORAD

Serial#: 007N8102402


Perkin Elmer 600 Series LINK Chromatography Interface

Model#: Series 600 LINK

Serial#: 600M01030350


Perkin Elmer 900 Series Interface

Model#: 950A

Serial#: 7007251572


Perkin Elmer Series 200 Vacuum Degasser

Model#: Series 200

Serial#: 5544


Perkin Elmer Series 200 Vacuum Degasser

Model#: Series 200

Serial#: 1672


Dell Optiplex 760

Model#: DCNE

Serial#: 3JCLD4J


The unit has TotalChrom Navigator software installed with login details provided.


AOC 913SN LCD Monitor + Keyboard & Mouse

Model#: TFT185W80PS

Serial#: 741A1BA001617



Manuals;

-Series 200 Column Oven and Peltier Column Oven

-TotalChrom Tutorial for Version 6.3

-Chromlab 51 Ways to Make TotalChrom Work for You!

-Series 200 Vacuum Degasser

-Intruction Manual for VACUUM OVENS

-Series 200 Autosampler

-Model 785A

-Series 200 LC Pump


Image of item

£ 2,000.00 (ex. VAT) 1 in stock

Thermo Separation Products HPLC System - Anachem - Spectra - Lab

ITEM-25214

This Thermo Separation Products HPLC System was removed from a university lab where it was surplus to requirements.


The system was working prior to removal but the PC was faulty and removed from the system.


Included in the system are;

1x Anachem unit

The unit powers on and is in good cosmetic condition.


1x TSP Vacuum Membrane Degasser

Model SCM 1000

The unit powers on and is in good cosmetic condition.


1x Spectra System

Model P4000

The unit powers on and is in good cosmetic condition.


1x Spectra System

Model SN4000

The unit is in good cosmetic condition.

We have not powered up the unit. We believe it is powered by another unit in the system or a PC.


1x Thermo Finnigan Spectra System Detector

Model UV6000LP

The unit powers on and is in good cosmetic condition.


1x Spectra Series

Model AS3000

The unit powers on and is in good cosmetic condition.


User Manuals:

1x Spectra Series Autosamplers ref manual

1x SCM1000 Vacuum Membrane Degasser ref manual

1x UV6000LP Detector ref manual

1x Spectra System & Spectra Series Gradient Pumps ref manual

1x Spectra System Autosamplers ref manual


All units are in good cosmetic condition. We are unsure if the manuals are complete.



Image of item

£ 1,975.00 (ex. VAT) 1 in stock

HP Series 1050 HPLC System Lab

ITEM-37626

This system was removed from a university lab where it was surplus to requirements.


The units power up but have not been tested further.


They are in reasonably good cosmetic condition with minor marks.


Included are;

1 x Solvent Conditioning Tray model 79856AX 

1 x Variable Wavelength Detector model 79853C 

1 x Autosampler model 79855 with 21 x 10ml position tube holder

1 x On-line Vacuum Degasser model G1303A 

2 x Isocratic Quaternary Pump model 79852A


Image of item

£ 1,290.00 (ex. VAT) 1 in stock

Perkin Elmer Series 200 HPLC System - Autosampler, Vacuum Degasser, LC Pump Lab

ITEM-24340

This Perkin Elmer Series 200 HPLC System was removed from a university lab where it was surplus to requirements.


All modules power up but we were unable to test them further at our facility.


The system is in good cosmetic condition with some marks from use.


Included are;


Perkin Elmer series 200 Autosampler

Sn. 293N8060506

Pn. N2930100


Perkin Elmer series 200 Vacuum Degasser

Sn. 1101002

Pn. N2600531


Perkin Elmer series 200 LC Pump

Sn. 291N7081802

Pn. N2910102


Image of item

£ 1,255.00 (ex. VAT) 1 in stock

Gynkotek P 580 A HPLC Pump & Dionex UVD 170S UV Detector System Lab

ITEM-24431

Gynkotek  P 580 A HPLC Pump & Dionex UVD 170S UV Detector System


This was removed from a university lab where it was surplus to requirements. The system powers up but has not been tested further.


It is in reasonably good cosmetic condition with marks from use.


It comprises of;


1 x Gynkotek HPLC

Type - P 580A


1 x Dionex UVD 170S

PN - 6068.4000A


1 x Dell Optiplex G1 with Keyboard & Mouse

Model no. MMP

Chromeleon Client Version 4.20 Build 350


1 x Box including:-

Gynkotek HPLC Pump Series P580 Operating Instructions

Gynkotek HPLC UV/VIS Detector UVD 170S/340S Operating Instructions

Chromeleon Chromatography Data Systems Version 4.20 Software CD & Tutorial



Image of item

£ 1,065.00 (ex. VAT) 1 in stock

Gilson Aspec XL4 HPLC System - 305 Pump, 805 Manometric Module, 811C Mixer Lab

ITEM-24342

This Gilson HPLC system was removed from a university lab where it was surplus to requirements.


All the units power up but have not been tested further at our facility.


Included are;


1 x Gilson Aspec XL4 Solid Phase Extraction


1 x Gilson 404 Syringe Pump


1 x Gilson 118 UV/VIS Detector


1 x Gilson 305 Pump


1 x Gilson 305 Pump


1 x Gilson 805 Manometric Module

Connects to 305 pump


1 x Gilson 811C Dynamic Mixer


1 x Gilson System Interface Model


3 x Gilson cases with small accessories


Box of cables


Image of item

£ 545.00 (ex. VAT) 1 in stock

Gilson HPLC Units - 305 Pumps, 118 UV/VIS Detector, 805 Manometric Module, 811B

ITEM-24343

This lot of Gilson HPLC Units were removed from a university lab where they were surplus to requirements.


Included are;


1 x Gilson 118 UV/VIS Detector

Powers on


1 x Gilson 305 Pump

Powers on


1 x Gilson 305 Pump

Powers on but the screen is faulty.


1 x Gilson 805 Manometric Module

Connects to 305 Pump


1 x Gilson 811B Dynamic Mixer

Powers on


All units are in reasonably good used cosmetic condition with marks and stains.


Image of item

£ 500.00 (ex. VAT) 1 in stock

Waters 474 Scanning Fluorescence Detector HPLC Lab

ITEM-38789

Waters 474 Scanning Fluorescence Detector HPLC


This was removed from a university lab where it was surplus to requirements.


The unit powers up and successfully self-tests its ROM, RAM, EM driver, EX driver, lamp energy are good and it reports a lamp operation of 1385.9 hours


It is in good cosmetic condition with minor marks.



Image of item

£ 325.00 (ex. VAT) 1 in stock

Shimadzu LC10-AS Liquid Chromatograph System Lab

ITEM-31356

This Shimadzu LC10-AS Liquid Chromatograph System was removed from a university lab where it was surplus to requirements.


The unit powers up and is in good cosmetic condition with minor marks from use. It has not been tested further.


It is supplied with a Shimadzu Syringe Unit .XL. We were unable to power this as it requires a 20-pin connecter.



Image of item

£ 255.00 (ex. VAT) 1 in stock

Gilson Chromatography System 831, 402 & 306 Pump, UV/VIS-156 Detector, Lab

ITEM-07203

This Gilson Chromatography System was removed from a university lab where it was surplus to requirements.


Included is;

1 x Gilson 831 Temperature regulator.

1 x Gilson 402 Syringe Pump - please note this does not power on.

1 x Gilson UV/VIS-156 UV/VIS.

1 x Gilson 306 Pump.

2 x Gilson Valve Mates.



Valve Mates:

Version 1.11.

One has 2457 Turns & 40636 Hours.

The other has 2371 Turns & 46801 Hours.



Everything is in good cosmetic condition with marks from use.


The units all power up except the Syringe Pump. The 306 pump runs but has not been tested further. The UV light says it powers up but we have not tested it further.


The temperature regulator was tested against our digital thermometer.

When tested to 37 degrees it was set at 38 degrees.

When tested to 100 degrees it reached 103.4 degrees.

When tested to 200 degrees (Max) it reached 201.8 degrees.



Items 1 to 20 of 21

Filters

Price (£)

to

Condition

Brand