Our RT-PCR and qPCR Machines category offers a selection of high-quality, second-hand real-time PCR (RT-PCR) and quantitative PCR (qPCR) systems. These machines are ideal for applications in gene expression analysis, molecular diagnostics, and DNA quantification. Specializing in both standard and high-throughput models, our range is perfect for research and clinical laboratories.


Equipment undergoes varying levels of testing, including functionality checks and fluorescence detection accuracy assessments, ensuring reliable and precise performance for your real-time PCR and qPCR needs.

Items 1 to 32 of 32

Image of Applied Biosystems QuantStudio 5 Real-Time PCR Machine 96-well Block

£ 23,000.00 (ex. VAT) 1 in stock

Applied Biosystems QuantStudio 5 Real-Time PCR Machine 96-well Block

ITEM-31662

Thermofisher Quant Studio 5 Real-Time PCR Machine


Inventory ID: DAM_QS5F

Condition: Used

Year: 2021

Vin/Serial No: 272528491


Full working order, sale is to due to this system being surplus to requirements


The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

Image of Applied Biosystems QuantStudio 12K Flex Accufill System Lab

£ 10,960.00 (ex. VAT) 1 in stock

Applied Biosystems QuantStudio 12K Flex Accufill System Lab

ITEM-24415

Applied Biosystems QuantStudio 12K Flex Accufill System


This was removed from a university lab where it was surplus to requirements.


The powers up but has not been tested further at our facility. The lab confirmed that it was in working order before it was put into storage.


It is in excellent cosmetic condition with marks from use.


Included with it are;

1x Box of Open Array 384 well sample plates (opened)

Part no. 4406947

10Pk


The plates are still inside a sealed bag and are in good cosmetic condition.


1x Open Array Acufill User guide:

The unit is in good cosmetic condition and appears to be complete. 



Cables:


2x USB A to USB B cables:

The units are in good cosmetic condition.


1x Blue ethernet cable:

REV C 4379889


Image of Applied Biosystems ViiA 7 Real-Time PCR System & Software Lab

£ 9,600.00 (ex. VAT) 1 in stock

Applied Biosystems ViiA 7 Real-Time PCR System & Software Lab

ITEM-36366

Applied Biosystems ViiA 7 Real-Time PCR System & Software


This was removed from a university lab where it was surplus to requirements.


The System and Laptop successfully communicated in testing via QuantStudio Software v1.6.1. The system is in good working order.


It is in good cosmetic condition with minor marks.


Included with it are;


1x Dell Latitude E6530 Laptop

P/N: 4487136

S/N: DE52175


1x Dell 19.5 volt power supply

P/N: OW6KV


1x Dell Latitude E6530 Laptop Setup Information


1x Windows XP Recovery Image USB Latitude E6530


1x Windows 7 Recovery Image USB E6530


1x Windows 7 Reinstallation DVD


1x Dell Resource Media CD


1x Dell Kensington type security lock

P/N: OM6517


1x Applied Biosystems Software CD, Primer Express V3.0.1

S/N: 446532


1x Applied Biosystems Getting Started Guide

P/N: 4362460


1x Ethernet Cable


1x Mains Cable IEC C19


Image of Applied Biosystems OpenArray Accufill Instrument Model 3072 PCR System Lab

£ 9,300.00 (ex. VAT) 1 in stock

Applied Biosystems OpenArray Accufill Instrument Model 3072 PCR System Lab

ITEM-24414

Applied Biosystems OpenArray Accufill Instrument Model 3072 PCR System


This was removed from a university lab where it was surplus to requirements.


The powers up but has not been tested further at our facility. The lab confirmed that it was in working order before it was put into storage.


It is in excellent cosmetic condition with marks from use.

Image of Applied Biosystems 7500 FAST Real-Time PCR System w/ PC & Software Lab

£ 5,000.00 (ex. VAT) 1 in stock

Applied Biosystems 7500 FAST Real-Time PCR System w/ PC & Software Lab

ITEM-20177

Applied Biosystems 7500 FAST Real-Time PCR System w/ PC & Software Lab


This system was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The PC runs Windows 7 and has the following software installed:

Life Version 2.3 7500


Lamp Hours:

409

The lamp was replaced on 10/20/2020.


The unit has not been calibrated, as it requires an Applied Biosystems real-time PCR system spectral calibration kit.


Included with it are;


1 x Box of Microamp 96-well tray for Veriflex blocks. (factory sealed)

1 x Kit, primer express V3.0.1 (factory sealed)

1 x Box of EnduraPlate optical 96-well fast multicolour reaction plate with barcode (factory sealed)

1 x. ASSY, OPTICAL TROUBLESHOOTING PLATE BLACK

1x Pack of paper fluorescent green 3-1/16 inch x 4-5/8 inch (8pcs/pkt)

1x Microamp Adhesive film applicator

1 x 7500 Software pack (factory sealed)

5 x Kettle Leads

1x Type G Gbr Irl, Mlt, Mas, Sin

1x Type F    EU, Rus

2x type B   Usa, Mex, Can, Jpn

1x type I    Aus, Arg, Chin, Nzl

Image of Applied Biosystems 7500 Fast Real-Time PCR System with PC & Software Lab

£ 5,000.00 (ex. VAT) 1 in stock

Applied Biosystems 7500 Fast Real-Time PCR System with PC & Software Lab

ITEM-24898

This Applied Biosystems 7500 Fast Real-Time PCR System with PC & Software was removed from a university lab where it was surplus to requirements.


The unit powers up and has been connected to the PC. It has been inspected by a service engineer who has re-certified it.


The PC is a Dell Optiplex PC with a monitor, keyboard & Mouse with Life Version 2.3 7500 software installed on it. The machine also has a fresh install of Windows 7.


The 7500 has passed the following function tests:

USB

CCD

Filter Wheel

Shutter

Lamp

Thermal Cycler

All tests passed.


The lamp condition is described as 'good'. It has 209 hours usage and the current is 5.597amps. It is reported as being replaced 06/24/2020.


The unit has not been calibrated as it requires an Applied Biosystems real-time PCR system spectral calibration kit

Image of Applied Biosystems 7500 Fast Real Time PCR System Lab

£ 5,000.00 (ex. VAT) 1 in stock

Applied Biosystems 7500 Fast Real Time PCR System Lab

ITEM-38919

Applied Biosystems 7500 Fast Real Time PCR System


This was removed from a university lab where it was surplus to requirements.


The unit powers up and has passed all hardware testes. The lamp is showing 2029 hours. It is communicating with the Windows 7 PC which has ABI Life v2.3 installed.


It is in excellent cosmetic condition with minor marks from use.


With it are;


1x Dell PC:

Model Optiplex 7010


1x Iiyama Prolite Monitor

Model B2282HS

21.5 inch screen


1x Dell Keyboard:

The unit is in good working and cosmetic condition.


1x Dell Mouse:

The unit is in good working and cosmetic condition.


Connecting cables.

Image of Pall GeneDisc Cycler Real Time PCR Platform for Pa Lab

£ 5,000.00 (ex. VAT) 1 in stock

Pall GeneDisc Cycler Real Time PCR Platform for Pa Lab

ITEM-40953

This Pall GeneDisc Cycler Real-Time PCR Platform for Pa was removed from a university lab where it was surplus to requirements.


The system powers on and is in a reasonably good cosmetic condition, we're unable to test it further at our facility.


The item carried out self-checks on start-up.


Included with the item:


Delta Electronics 12-volt Screen Power Supply

Image of Applied Biosystems 7500 Fast Real-Time PCR System Lab

£ 4,500.00 (ex. VAT) 1 in stock

Applied Biosystems 7500 Fast Real-Time PCR System Lab

ITEM-44525

Applied Biosystems 7500 Fast Real-Time PCR System Lab


This system was removed from a university lab, where it was surplus to requirements.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


Also includes the following:


  1. Real-Time PCR Systems - Chemistry Guide

  1. Applied Biosystems Site Preparation Guide

  1. Applied Biosystems Getting Started Guide

  1. Allelic Discrimination Guide

  1. 7500 Fast Real-Time Software V1.4

  1. MicroAmp Adhesive Film

Image of Applied Biosystems 7900HT Fast Real Time PCR System with 7067/4 Stacker Lab

£ 4,000.00 (ex. VAT) 1 in stock

Applied Biosystems 7900HT Fast Real Time PCR System with 7067/4 Stacker Lab

ITEM-26003

This Applied Biosystems 7900HT Fast Real Time PCR System was removed from a university lab where it was surplus to requirements.


The system is in good used cosmetic condition. The lab confirmed it was in working order prior to removal.


We have been able to connect the unit to the PC, but are unable to test it further.


It consists of the following parts:


1 x Applied Biosystems 7900HT

Part no. 4330966

SN - 279002990


1 x SICK CLV422-1910S02 Fixed barcode scanner


1 x AB 7067/4 Microplate stacker.


1 x Symbol Barcode Scanner.


1 x Dell Optiplex 960 PC with Dell Monitor, keyboard and mouse.


The has the following software installed:-

Applied Biosystems 7900HT Version 2.4 Sequence Detection Systems (SDS)

Applied Biosystems RQ Manager Version 1.2.1


We have all the passwords, which are available on request once the system has been sold.

Image of Applied Biosystems 7900HT Fast Real Time PCR System Part no. 4330966 Lab

£ 4,000.00 (ex. VAT) 1 in stock

Applied Biosystems 7900HT Fast Real Time PCR System Part no. 4330966 Lab

ITEM-26269

This Applied Biosystems 7900HT Fast Real Time PCR System was removed from a university lab where it was surplus to requirements.


The system powers up and is in good cosmetic condition with only minor usage marks.


We have been able to connect the unit to the PC, but unable to test it further. It will likely require servicing before it is used.



PC Equipment:-

Dell Optiplex GX280 with Dell Monitor, keyboard and mouse

PSC QS6000 Plus Barcode Scanner


PC has the following software:-

Applied Biosystems 7900HT Version 2.3 Sequence Detection Systems (SDS)

Applied Biosystems RQ Manager Version 1.2


External dimensions -D85 W54 H76cm

Image of Corbett Research Rotor-Gene RG-3000 with PC & Software Lab

£ 3,405.00 (ex. VAT) 1 in stock

Corbett Research Rotor-Gene RG-3000 with PC & Software Lab

ITEM-38976

Corbett Research Rotor-Gene RG-3000 with PC & Software


This was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with the software. It was programmed to run and worked well in testing.


It is supplied with a Windows 7 PC with RotoGene 6.1 installed.


Rotor holds 36 x 0.2ml


Comes with:-

PC Cable

2 x Spare rotor parts

2 x Operators Manuals

Rotor Gene Back Up Floppy Disk

Rotor Gene Data Floppy Disk

The Rotor Gene Set up Files v4.2

Rotor-Gene Software Version 4.6

Rotor-gene 3000 Operating Software V4.6.94

RotorGene 36/72 Maintenance Pack 1.0/1.1

There are 4 more copied discs of the same


Image of Corbett Research Rotor-Gene RG-6000 Real-time PCR Analyser Lab

£ 2,150.00 (ex. VAT) 1 in stock

Corbett Research Rotor-Gene RG-6000 Real-time PCR Analyser Lab

ITEM-39275

Corbett Research Rotor-Gene RG-6000 Real-time PCR Analyser


This was removed from a university lab where it was surplus to requirements.


The unit powers up and passes warmup sequences. It connects to the PC and communicates.


It is fitted with a 100 disc with lockring.


It is in very good cosmetic condition with minor marks.


The system includes a Windows 7 Dell PC running Quaigen Rotor-Gene Q 2.4.3.

Image of Applied Biosystems 7300 Real Time PCR System with PC & Software Lab

£ 2,100.00 (ex. VAT) 1 in stock

Applied Biosystems 7300 Real Time PCR System with PC & Software Lab

ITEM-30000

This Applied Biosystems 7300 Real Time PCR System was removed from a university lab where it was surplus to requirements.


The system is comprised of;


1 x Applied Biosystems 7300 Real-Time PCR Unit.


1 x Dell Optiplex 380 with Monitor, keyboard, mouse, USB cable & monitor cable.

Running Applied Biosystems Sequence Detection Software (SDS)

Version 1.2.3.

The Dell has a Fresh install of Windows XP.


The 7300 has had a function test run:


USB - Pass

CCD - Pass (version 2.19)

Filter Wheel - Pass (FW version G2.10)

Shutter - Pass (FW version G2.10)

Lamp - Pass (FW version G2.10)

Thermal Cycler - Pass (G2.10 Firmware is up to date)


The lamp status is Good.

It has 1444 Usage hours.

It was last replaced 08/01/2008.


The unit will require the ROI calibration.


Image of Applied Biosciences 7900HT Fast Real-Time PCR Complete System Lab

£ 2,010.00 (ex. VAT) 1 in stock

Applied Biosciences 7900HT Fast Real-Time PCR Complete System Lab

ITEM-41491

Applied Biosciences 7900 HT Fast Real-Time PCR Complete System Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


Includes:

  1. 16A 1Phase cable

Image of Applied Biosystems 7900HT Fast Real-Time PCR System - PN 4330966 Lab

£ 2,000.00 (ex. VAT) 1 in stock

Applied Biosystems 7900HT Fast Real-Time PCR System - PN 4330966 Lab

ITEM-19829

This Applied Biosystems 7900HT Fast Real-Time PCR System was removed from a university lab where it was surplus to requirements.


The unit powers up but has not been tested further. It is in reasonably good cosmetic condition but has some marks from use.



Image of Stratagene MX3000P Multiplex Quantitative RT- PCR System  Lab

£ 2,000.00 (ex. VAT) 1 in stock

Stratagene MX3000P Multiplex Quantitative RT- PCR System Lab

ITEM-20271

This Stratagene MX3000P Multiplex Quantitative RT- PCR System was removed from a university lab where it was surplus to requirements.


The main unit is in reasonably good, used cosmetic condition but it does have some scrapes, scratches and marks from use.


The unit powers up and both Green LEDs light. You can also feel the well block heating up. The well block is 96 hole.


The system includes:


1 x Agilent Stratagene MX3000P. (various marks from use)

1 x Dell Optiplex755 PC with keyboard & mouse.

1 x Monitor. (various marks from use)

1 x VGA Cable.

1 x RS232 Cable.


The PC is running a fresh install of Windows 7. Installed is a copy of Stratagene MxPro - Mx3000P v4.10 build 389.

The software will control the Mx3000P unit. We have run a basic heat cycle with it and verified that the lamp will turn on & off. It has not been tested any further.




Image of Stratagene MX3000P Multiplex Quantitative RT- PCR System  Lab

£ 2,000.00 (ex. VAT) 1 in stock

Stratagene MX3000P Multiplex Quantitative RT- PCR System Lab

ITEM-39047

This Stratagene MX3000P Multiplex Quantitative RT- PCR System was removed from a university lab where it was surplus to requirements.


The system is in good cosmetic condition.


All units power up and communicate, we are unable to test the system further at our facility.


The software installed is MxPro 4.10 Build 389.


The system consists of the following:


1x Hewlett-Packard EliteDesk PC


1x IiyamaMonitor


1x Hewlett-Packard Keyboard


1x Dell Mouse


2x VGA connecting cables

Image of Agilent Technologies Stratagene MX3000P System w/ Software Lab

£ 2,000.00 (ex. VAT) 1 in stock

Agilent Technologies Stratagene MX3000P System w/ Software Lab

ITEM-41564

Agilent Technologies Stratagene MX3000P System w/ Software Lab


This system was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition and powers on, it is paired with MxPro software.


System software shows - Lamp Hours: 1823:49.


PC runs Windows XP.

Image of Thermo Hybaid MCA Melting Curve Analysis qPCR System Lab

£ 1,765.00 (ex. VAT) No longer available

Thermo Hybaid MCA Melting Curve Analysis qPCR System Lab

ITEM-36229

Thermo Hybaid MCA Melting Curve Analysis qPCR System


This was removed from a university lab where it was surplus to requirements.


Item is in reasonable cosmetic condition with signs of damage such as residue and surface damage.


The item powers on with the front display light and fan in working order but we were unable to test it further.


Image of Thermo Hybaid MCA System qPCR  Melting Curve Analysis Lab

£ 1,760.00 (ex. VAT) 1 in stock

Thermo Hybaid MCA System qPCR Melting Curve Analysis Lab

ITEM-36232

ITEM-36232

Image of Thermo Hybaid MCA qPCR  Melting Curve Analysis System Lab

£ 1,760.00 (ex. VAT) No longer available

Thermo Hybaid MCA qPCR Melting Curve Analysis System Lab

ITEM-36230

Thermo Hybaid MCA Melting Curve Analysis qPCR System


This was removed from a university lab where it was surplus to requirements.


Item is in reasonable cosmetic condition with signs of damage such as residue and surface damage.


The item powers on with the front display light and fan in working order but we were unable to test it further.

Image of Agilent Technologies Stratagene Mx3005P PCR System With Software

£ 1,500.00 (ex. VAT) 1 in stock

Agilent Technologies Stratagene Mx3005P PCR System With Software

ITEM-36026

Agilent Technologies Stratagene Mx3005P PCR System


This was removed from a working lab where it was surplus to requirements.


The unit powers up and has been tested with the PC. It communicates and operates well. The lab confirmed it was fully operational prior to removal.


It is supplied with a Dell PC with MxPro 4.10 software installed.


The system is in excellent cosmetic condition with minor marks.


The MX3005P has the following filters installed:


  1. CY5 - CY5 Filter Set - Excitation Wavelength(NM) 635 - Emission Wavelength(NM) 665.
  2. CY3 - CY3 Filter Set - Excitation Wavelength(NM) 545 - Emission Wavelength(NM) 568.
  3. ROX - ROX Filter Set - Excitation Wavelength(NM) 585 - Emission Wavelength(NM) 610
  4. HEX - HEX-JOE Filter Set - Excitation Wavelength(NM) 535 - Emission Wavelength(NM) 555
  5. FAM - FAM Filter Set - Excitation Wavelength(NM) 492 - Emission Wavelength(NM) 516

The total lamp hours are: 277:12.

The timer was last reset: 28/09/2011.


Includes:


-Stratagene MxPro QPCR Software V4.10d

-Software Certificate And Registration Packet

-Agilent Data System Recovery Kit

-Mx3005P Setup And User's Guide

-Keyboard and mouse

-Monitor +PC



Image of Roche LightCycler 480 II/96 PCR Real Time RT-PCR Machine Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,350.00 (ex. VAT) 1 in stock

Roche LightCycler 480 II/96 PCR Real Time RT-PCR Machine Lab Spares/Repairs

ITEM-36517

Roche LightCycler 480 II/96 PCR Real Time RT-PCR Machine


This was removed from a university lab where it was surplus to requirements.


The unit powers up but the LightCycler is showing errors during the installation


100900270 - Restart instrument.

100600130 - Command not allowed - I believe this error is actually caused by the one above.

We have added images of the errors etc, but the computer will not be included.

Lamp Absolute Intensity - 9853

Operation Time - 572h.


It is in good cosmetic condition with minor marks from use.


It is sold for spares/repairs.


It is supplied with the following accessories.


1x ThermoCycler 96-s (boxed)

S/N: 030203

P/N: 05015162001


1x ThermoCycler 384 silber (fitted)

S/N: (21) 7298

P/N: 050154001


1x LightCycler 480 Software CD Release 1.5.0


7x Boxes of 96-well PCR microplates

O/N: I1402-9909


13x Boxes of 384-well PCR plates

O/N: E1402-9909


3x 2.5a 20 mm anti surge fuses


1x Maxon Motor (suspected faulty, as mentioned in report)


5x Mains power leads


1x 24 volt power supply

Image of Applied Biosystems Model 7000 Abi Prism  PCR Sequence Detection System Lab

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 1,150.00 (ex. VAT) 1 in stock

Applied Biosystems Model 7000 Abi Prism PCR Sequence Detection System Lab

ITEM-18458

This Applied Biosystems Abi Prism Model 7000 PCR Sequence Detection System was removed from a university lab where it was surplus to requirements.


This was removed from a university lab where it was surplus to requirements.


The unit powers up and has passed all self-tests. It is in good working order.


It comes with a Dell Optiplex PC, Keyboard & Mouse.

The PC has a fresh install of Windows XP and it is running AB SDS 1.2.3.


There is a 96-Well 5mm Thermal Cycler Block in it.




Image of  Stratagene Mx3005P Real-Time PCR System + PC & Software Lab

£ 1,000.00 (ex. VAT) 1 in stock

Stratagene Mx3005P Real-Time PCR System + PC & Software Lab

ITEM-18677

This Agilent Stratagene Mx3005P Real-Time PCR System was removed from a university lab where it was surplus to requirements.


The main unit is in reasonable used cosmetic condition but it does have some scrapes, scratches and marks from use.


The unit powers up and both Green LED's light. You can also feel the well block heating up. The well block is 96 hole.


The system includes:

1 x Agilent Stratagene MX3005P. (various marks from use)

1 x Dell E8400 PC with keyboard & mouse which we believe to be brand new.

1 x iiyama monitor. (various marks from use)


The PC has has a new HDD fitted and is running a fresh install of Windows 7. Also installed is a copy of Stratagene MxPro - Mx3005P v4.10 build 389. The software will control the Mx3005P unit. We have run a basic heat cycle with it and varified that the lamp will turn on & off. It has not been tested any further.


The PC comes with a brand new sealed keyboard & mouse and a used iiyama monitor is also included.


The system should include everything required to operate.


Image of Applied Biosystems ABI Prism 7900HT Sequence Detection System Lab Spares/Repairs

£ 950.00 (ex. VAT) 1 in stock

Applied Biosystems ABI Prism 7900HT Sequence Detection System Lab Spares/Repairs

ITEM-30573

Applied Biosystems ABI Prism 7900HT


This was removed from a university lab where it was surplus to requirements.


The unit powers up but has the following issues.


The 7900 did connect to the PC at first but there appears to be a fault with the plate loader. The door will not open when instructed. If you try to run a program you get a 3003 error. 'unable to load the plate, Tray not at up position'.

There was a loud humming noise coming from the unit which appeared to get louder the longer it was switched on. Then would no longer connect to the PC. We have removed the side panels but cannot see any obvious issues.


It is sold for spares/repairs.


The PC is included.


Dell Optiplex PC

Dell 17" Monitor

Keyboard & Mouse

USB Cable

DVI Cable


All parts power on and work, the pc has ABI 7900HT Sequence Detection Systems Version 2.4.1 Software.


Image of BioTrove OpenArray NT Cycler qPCR Instrument Model - 20001-200 & Software Lab

£ 870.00 (ex. VAT) 1 in stock

BioTrove OpenArray NT Cycler qPCR Instrument Model - 20001-200 & Software Lab

ITEM-24413

BioTrove OpenArray NT Cycler qPCR Instrument Model - 20001-200 & Software


This was removed from a university lab where it was surplus to requirements.


The unit powers up but has not been tested further. It is in good cosmetic condition with minor marks.


Included are;


BioTrove OpenArray NT Cycler:

Model - 20001-200

SN - 0498


Accessories:


1x BioTrove OpenArray Case Sealing Station:

Model - 20253

SN - CS0571

The unit powers on and is in good cosmetic condition.



Software CDs


1x Open Array Real-time qPCR Analysis Software CD:

item no. 4435938

Version 1.0.4


1x Open Array Instrument Configuration CD:

Part no. 20395


1x Open Array SNP Genotyping Analysis Software CD:

Part no. 20919


Version 1.0.5








Image of Roche LightCycler 480 II /96 PCR Real Time Thermal Cycler Lab RT-PCR Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 635.00 (ex. VAT) 1 in stock

Roche LightCycler 480 II /96 PCR Real Time Thermal Cycler Lab RT-PCR Faulty

ITEM-20612

This unit was removed from a lab as surplus to requirements. The lab assured us it was in working order when last used, but we do not have a PC or software to test this instrument at our site.


In the testing we were able to carry out, the item powers on, both front lights were flashing orange.


We attempted to test it with a PC and software (not included). The unit is failing to initialise during the startup. It seems to be failing at the 'camera cooling surveillance' section.


Item is in a good used cosmetic condition.


It is sold for spares/repairs

Image of Applied Biosciences 7900 HT Fast Real-Time PCR Complete System Lab

£ 600.00 (ex. VAT) 1 in stock

Applied Biosciences 7900 HT Fast Real-Time PCR Complete System Lab

ITEM-24006

Applied Biosciences 7900 HT Fast Real-Time PCR Complete System


This was removed from a university lab where it was surplus to requirements.


We were able to get the unit to communicate with the PC but we were unable to get it to run cycles due to a serial number conflict. We were able to open the door but not close it again.


Included with it are;


1 x DELL PC

Windows Vista Business


1 x SDS 2.3

Item is in a good used condition. The Item powered on and working, but not connecting to PCR Tester


1 x Bti PRGF Desktop Centrifuge

It is in good used condition. The item powered on and was tested, all working


4 x PGRF CF10142 LOT 2894


1 x Diagnostica Stago Printer

Item powered on and tested, all working


1 x Datalogic QS6000 Plus Barcode Reader

The item powered on and was tested, all working


Associated books and a spare Block Assembly.


Image of Applied Biosystems ABI Prism 7700 Sequence Detection System  Model - 7700 Lab

£ 320.00 (ex. VAT) 1 in stock

Applied Biosystems ABI Prism 7700 Sequence Detection System Model - 7700 Lab

ITEM-26200

This Applied Biosystems ABI Prism 7700 Sequence Detection System  Model - 7700 was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further.


It is in reasonable cosmetic condition but has marks from use.


Pre-installation Manual

Planned Maintenance Protocol

Site Preparation & Safety Guide





Image of Qiagen QIAgility Automated PCR Prep System Lab

£ POA 1 in stock

Qiagen QIAgility Automated PCR Prep System Lab

ITEM-45233

This item is new in stock. Please enquire for further details.

Items 1 to 32 of 32

Filters

Price (£)

to

Condition

Brand