Mass Spectrometry (MS)
Items 1 to 20 of 25
£ 28,735.00 (ex. VAT) 1 in stock
Thermo Scientific LTQ Orbitrap XL Hybrid Ion Mass Spec & Neslab ThermoFlex 900
ITEM-29793
This Thermo Scientific LTQ Orbitrap XL Hybrid Ion Mass Spectrometer was removed from a university lab where it was surplus to requirements.
The system powers up and is in excellent cosmetic condition. It was confirmed by the lab that it was working when last used in December 2022, though it is out of service.
Included in the system are;
1 x Thermo Scientific LTQ Orbitrap XL.
1 x Thermo Scientific LTQ XL.
1 x Thermo Scientific Neslab ThermoFlex 900.
1 x Edwards 28 Vacuum Pump.
1 x Edwards 30 Vacuum Pump.
1 x Orbitrap Extractive Operations Training Course Manual.
1 x LTQ Orbitrap Biotech Operations Training Course Manual.
1 x Thermo Scientific LTQ Manual.
1 x Thermo Scientific LTQ Orbitrap XL Hardware Manual.
2 x Thermo Scientific LTQ Orbitrap XL 2.5.5 Software.
1 x Thermo Scientific LTQ 2.6.0 SP1 Instrument Control.
1 x Thermo Scientific Xcalibur 2.0.7 SP1.
1 x JAI CV-A55 IR Camera & housing.
£ POA 1 in stock
Bruker Esquire 300 Plus Mass Ion Trap Spectrometer
ITEM-38685
This item is new in stock. Please enquire for further details.
£ 18,000.00 (ex. VAT) 1 in stock
Thermo Finnigan LCQ Advantage Mass Spectrometer Surveyor LC-MS System & Software
ITEM-17274
Thermo Finnigan LCQ Advantage Mass Spectrometer Surveyor LC-MS System
This was removed from a university lab where it was surplus to requirements. The lab confirmed that everything was in working order prior to removal. We have powered up everything but were unable to test further at our facility.
All the units are in good cosmetic condition with minor marks.
Included are;
1 x Thermo Finnigan LCQ Advantage Mass Spectrometer System
Serial No. LAD00300
1 x Surveyor PDA Detector
Part No. SRVYR-PDA5
Serial No. 56866
1 x Surveyor Autosampler
Part No. SRVYR-AS
Serial No. 77269
1 x Surveyor MS Pump
Part No. SRVYR-LPUMP
Serial No. 62615
1 x Edwards 28 Vacuum Pump
Model E2M28
Serial No. 170517841
Supplied with:
1 x Xcalibur LCQ Advantage Revision 1.3.
1 x Xcalibur LCQ Advantage/DecaXP Revision 1.3 SP1.
1 x Xcalibur Core Data System Software Revision 1.3.
1 x Thermo MSQ 2.0 SP2 Instrument Control.
1 x Thermo Xcalibur 2.1 W/Foundation 1.0.2 Rev.B.
1 x Thermo Xcalibur LC Devices 2.4.0.
2 x Thermo Xcalibur LC Devices 2.3.0 Software.
1 x Thermo TSQ Series 2.1.1.
1 x Thermo SurveyorPlus Manual Set.
1 x Thermo Part No. 23043457 Start cable Integrator/Gtrace.
1 x Thermo Part No. 23038071 Recorder Cable L=1900mm.
1 x Emerson Industrial Automation Leroy-Somer Engine;
2 x Spark Generators;
1 x PULNIX 20mm CCD Camera;
5 x Cables;
3 x Spacer 7.7x3.2;
1 x Spacer 6.3x3.2;
2 x ThermoFisher Scientific Tubing Fused SI 150Ux390U;
2 x Storer: TFS;
1 x ThermoFisher Scientific Insulator Heater APCI;
1 x O-Ring;
1 x Plunger.
£ 17,635.00 (ex. VAT) 1 in stock
Thermo Scientific Exactive LC-MS Liquid Chromatography Mass Spec System Lab
ITEM-29944
Thermo Scientific Exactive Mass Spectrometer LC-MS/MS System
This was removed from a university lab where it was surplus to requirements.
The system powers up and is in good working order but has not been tested further at our facility.
The system does not have the optional HCD system installed.
Included are;
Thermo Scientific Exactive LC-MS
S/N - SN01200P
Oerlinkon Leybold Sogevac SV40BI Pump
S/N - SV40BIFC 960364V 31001158805
Chemyx Fusion 100T Syringe Pump
The software for the system is included, but not installed on a PC.
It is supplied with a set of accessories and consumables.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 13,620.00 (ex. VAT) 1 in stock
Thermo Scientific LTQ Orbitrap Velos with ETD Mass Spectrometer Lab Faulty
ITEM-36829
Thermo Scientific LTQ Orbitrap Velos with ETD Mass Spectrometer
This was removed from a university lab where it was surplus to requirements.
The university said it hadn't worked properly for some time, and on inspection, it had been slightly stripped for parts.
We did not power it up to avoid damage to the unit.
It is in otherwise good cosmetic condition with marks from use.
£ 7,000.00 (ex. VAT) 1 in stock
Thermo Elemental X Series ICP-MS Mass Spectrometer w/ Software & Accessories
ITEM-24223
Thermo Elemental X Series ICP-MS Mass Spectrometer w/ Software & Accessories
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility. We are told it was working when it was last used in 2020.
It is in good cosmetic condition with minor marks.
Included with it are;
Original software on CD-ROM X Series PlasmaLab 2.6 ICP-MS software
Several manuals, safety, performance and maintenance schedule, pre-installation and operation
New and used spare skimmer and sampler cones
Spare electron multiplier
new and used spare printed circuit boards
Various tubing and connectors
Packet of various Thermo O rings
Many other unidentified small parts in sealed packaging
£ POA 1 in stock
Perkin Elmer TurboMass Gold AutoSystem XL GC-MS System & Accessories Lab
ITEM-35765
This item is new in stock. Please enquire for further details.
£ 5,925.00 (ex. VAT) 1 in stock
HP 6890 5973 Series G1999A GC-MS Gas Chromatograph Mass Spectrometer System
ITEM-38778
HP 6890 5973 Series G1999A GC-MS Gas Chromatograph Mass Spectrometer System
This was removed from a university lab where it was surplus to requirements.
The lab confirmed that it is in good working order. At our facility we have connected the system together and powered it up, but not tested further.
It is in good cosmetic condition with minor marks.
Included are;
HP ALS ready G1530A
Serial No. US00028126
HP 5973 Mass Selective Detector
G1999A
Serial No.US91430461
HP 59864B Ionisation Gauge Controller
Serial No. US60103518
£ 4,700.00 (ex. VAT) 1 in stock
Europa Scientific ANCA NT System & 20-20 Stable Isotope Analyser Lab
ITEM-28233
Europa Scientific ANCA NT System & 20-20 Stable Isotope Analyser
This was removed from a university lab where it was surplus to requirements.
The system powers up but we were unable to test it further without the PC and software.
The screen on the unit doesn't come on but we are advised that the little screens on the front of ANCA NT’s have never worked. They don’t affect the ability to use the instrument.
Included are;
1 x Europa Scientific ANCA NT System
1 x Stable Isotope Analyser
Model - 20/20
SN - 9007-072
Powers on
£ 3,825.00 (ex. VAT) 1 in stock
Hewlett Packard HP 6890 GC Gas Chromatograph System -59864B, 5973 Lab
ITEM-19312
This Hewlett Packard 6890 GC Gas Chromatograph System was removed from a university lab where it was surplus to requirements.
The system is in reasonably good cosmetic condition but it does have some marks and scratches from use.
All the components power up but have not been tested any further.
The system consists of:
1 x Hewlett Packard 6890 Series GC System.
It powers up and the oven runs.
1 x Hewlett Packard GC System Injector.
The unit powers up.
1 x Hewlett Packard 5973 Mass Selective Detector.
The unit powers up.
1 x Hewlett Packard GC Autosampler Controller.
The unit powers up and supplies power to the Injector.
1 x Hewlett Packard 59864B Ionization Gauge Controller.
The unit powers up.
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 3,000.00 (ex. VAT) 1 in stock
Dionex Ion Chromatography System AS40, LC25, IC20 Lab
ITEM-38972
Dionex Ion Chromatography System
This was removed from a university lab where it was surplus to requirements.
The system has been professionally serviced and is in good working order. A full report is available on request.
It is in good cosmetic condition with minor marks.
Included are;
Dionex AS40 Automated Sampler
Model: AS40-1
Serial#: 98040160
Dionex IC20 Ion Chromotograph
Model: IC20
Serial#: 99120293
Dionex LC25 Chromatography Oven
Model: LC25
Serial#: 0205041
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,650.00 (ex. VAT) 1 in stock
Bruker Ultraflex III LRF200 - CID Mass Spectrometer Lab Spares/Repairs
ITEM-30225
This Bruker Ultraflex III LRF200 - CID Mass Spectrometer was removed from a university lab where it was surplus to requirements.
The unit powers up but has a fault either with the MALDI source applied voltage, or the power supplies. The voltage on in the ion source plate is not reaching the set point of 25kV and is giving an error.
This could be
1. Source contamination. The source has been cleaned and will be cleaned again, but it only takes a trace of deposited carbon to cause a discharge. A thorough clean may fix it or a replacement source block.
2. High voltage power supply issue
The item is in reasonable, used cosmetic condition but the left-hand side panel/door is out of line so doesn't close properly. Both front and back bottom panels were removed to adjust the feet to move the unit around on its wheels.
It is sold for spares/repairs due to the fault.
£ 1,370.00 (ex. VAT) 1 in stock
Kratos Analytical Axima-CFR Plus MALDI TOF Mass Spectrometer Lab
ITEM-35695
Kratos Analytical Axima-CFR Plus MALDI TOF Mass Spectrometer
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
It is in excellent cosmetic condition with only minor marks.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,225.00 (ex. VAT) 1 in stock
Micromass LCT TOF Mass Spectrometer Lab Spares/Repairs
ITEM-36946
This Micromass LCT TOF Mass Spectrometer was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition with minor marks.
The lab reported that it was for spares or repairs but the fault is unknown. When we collected it, all the panels were removed, but we have fixed them back on.
Edwards parts fitted:-
SP25K N 9 Bar (SN-0171836682)
FL20K Foreline Trap (PN-A13305000/SN-165003057)
EXDC80 (PN-D39640000)
It is sold for spares/repairs.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Thermo Scientific TSQ Quantum Access Mass Spectrometer System - Faulty Ion Gauge
ITEM-31254
Thermo Scientific TSQ Quantum Access Mass Spectrometer System - Faulty Ion Gauge
The unit powers up but has not been tested further at our facility. We are told it is not in working order and requires a new Ion gauge.
It is in otherwise good cosmetic condition but is sold for spares/repairs.
Comes with boxed parts:-
Opton-20012 APCI Probe, Ion Max Source
Opton-20012 APCI Probe USI
Also comes with varous packs of tubed fusing.
£ 785.00 (ex. VAT) 1 in stock
Fisons Instruments GC 8000 Series Gas Chromatograph System
ITEM-17140
This Fisons Instruments GC 8000 Series GC Gas Chromatograph System was removed from a university lab where it was surplus to requirements.
The units are all in reasonably good cosmetic condition but have various marks from use.
The system consists of:
1 x Fisons GC 8000 Series With Cyro 820.
The unit powers up fine but was not tested any further.
1 x Fisons MD 800.
The unit powers up fine but was not tested any further.
1 x Fisons A200S.
The unit powers up fine but was not tested any further.
1 x Edwards Pump E2M-15 with Edwards Foreline Trap.
The unit powers up but doesn't appear to be drawing much pressure. It has been tested with a gauge.
1 x Compaq Desktop Windows NT PC with keyboard, monitor & mouse.
The PC has the following software installed:
Xcalibur: Instrument Configuration, MD Series, Tune & Xcalibur.
ViCAM Utilities.
Plus std Windows NT Software.
We have cleared all user data and passwords but left the software installed.
Also includes various cables for connection and some loose parts.
£ 710.00 (ex. VAT) 1 in stock
Dionex Eluent Generator EG40 Lab
ITEM-38968
This Dionex EG40 Eluent Generator was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further. It passed self tests.
It is in good cosmetic condition with minor marks.
£ 700.00 (ex. VAT) 1 in stock
Dionex Model EG40 Eluent Generator Lab
ITEM-38969
This Dionex EG40 Eluent Generator was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further. It passed self tests.
It is in good cosmetic condition with minor marks.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 630.00 (ex. VAT) 1 in stock
Bruker ImagePrep Sample Preparation Matrix Deposition Device Lab Faulty
ITEM-19309
This Bruker ImagePrep Sample Preparation Matrix Deposition Device was removed from a university lab where it was surplus to requirements.
The unit is in good used cosmetic condition but it does have some marks and signs of use.
It powers up fine and we have been through a few of the menus and they all work as they should. We were unable to test further as it requires a gas supply etc. We were told by the lab manager that it needed additional parts to make it operational, though we are unsure what exactly the fault is.
It comes with a touch pen.
£ POA 1 in stock
Thermo Scientific Surveyor MSQ Plus Mass Spectrometer System
ITEM-38437
This item is new in stock. Please enquire for further details.
Items 1 to 20 of 25