Genomics
Items 1 to 20 of 120

£ 55,000.00 (ex. VAT) 1 in stock
Pacific Biosciences Sequel DNA Sequencing System Lab
ITEM-34967
Pacific Biosciences Sequel DNA Sequencing System
This was removed from a university lab where it was surplus to requirements.
The unit was booted up on the client's site. Unfortunately, the PSU was not supplied to us.
The system boots up but shows errors in relation to a smrt link server. There was no smrt link server on the client's network which is what caused this issue.
It is in very good cosmetic condition but has a dent on one of the panels.
Comes with:-
(Boxed) Solid State Cooling Systems
Model - UC180
PN - 10-180-G1-P20-R
SN - 8008262
No power supply to test.
Consumables:-
1 x Sealed Pack of TX1009 AlphaWipe Polyester Wipers 9" x 9" (75 Wipes)
1 x Sealed Pack of TX404 Absorbond Polyester Wipers 4" x 4" (300 Wipes)
2 x Bottles of Sequel Coolant - Dynalene PG 30% - Both expired 2018/19
21 x Pacific Biosciences 96 well Verification Plates
6 x Bio-Rad Hard Shell 96-Well Sample Plates
1 x Pacbio Sequel Pipet Tips v2 (sealed)
1 x Pacbio Sequel Pipet Tips (31 tips left)
2 x Boxes Sequel SMRT Cell Oil (5 left in one/6 left in other)
1 x Tecan Conductive 200ul 96pcs rack (no tips)
4 x Packs SMRT Cell Mechanical (1 sealed/3 opened)
4 x Packs Pacbio Tube Septa (10 per pack)
1 x Pack of 11 Pacbio 0.5ml Empty NFC Verification Tubes
1 x Thermal Block
1 x Pack TX759B CleanTips Swabs (100 Swabs, Sealed)
1 x Uline Kapton Tape
1 x Red Ethernet Cable
2 x Pacbio Sequel Sample Plate Adhesive Foil

£ 23,000.00 (ex. VAT) 1 in stock
Quant Studio 5 Real-Time PCR Machine 96-well Block
ITEM-31662
Thermofisher Quant Studio 5 Real-Time PCR Machine
Inventory ID: DAM_QS5F
Condition: Used
Year: 2021
Vin/Serial No: 272528491
Full working order, sale is to due to this system being surplus to requirements

RECERTIFIED ITEM
RECERTIFIED ITEM
£ 12,875.00 (ex. VAT) 1 in stock
Qiagen QIAsymphony Nucleic Acid Purification System Lab
ITEM-31201
This Qiagen QIAsymphony Nucleic Acid Purification System was removed from a university lab where it was surplus to requirements.
The system has been inspected by a service engineer who unlocked the system and ran various maintenance tasks on the robot. The various passwords will be supplied upon purchase of the system.
Qiagen QIAsymphony Nucleic Acid Purification System
Model - QIAsymphony SP
SN - 11704
Unit dimensions - L127 W73 H103cm
The item powers on and is in a good used cosmetic condition.
It comes with the following parts/consumables:-
4GB USB Dongle
QIAsymphony Management Console V4.0
Qiagen Notebook V4 W7 32 (9023681) Restore CD (3 Discs)
Elution Microtube Rack (9020730)
5 x SIC-01
PC-01
Waste bottle
1 x Box of 5 QX Nitrogen Cylinders (929705)
8 x Boxes of Qiagen 200ul (1024) Filter Tips (990332)
1 x Box QIAsymphony Installation Cartridge Kit
1 x Box BGR O-Ring Tool
1 x Box QIAamp DNA Blood Maxi Kit
4 x Boxes 8-Rod Covers (144) (997004)
1 x Box Elution Microtubes CL 24 X 96 (19588)
1 x Box Reagent Cartridge Holder (997008) Box appears to have a mix of bits inside
2 x Boxes 50ul (960) Filter Tips
3 x Boxes 1500ul (1024) Filter Tips
2 x Boxes 8-Well (336) Sample Prep Cartridges (997002)
1 x Box marked as 'Odds' includes 5 x 8-Well (336) Sample Prep Cartridges, 6 x 200ul 4 x 32 Filter Tips

RECERTIFIED ITEM
RECERTIFIED ITEM
£ 9,155.00 (ex. VAT) 1 in stock
Applied Biosystems 7500 Fast Real-Time PCR System with PC & Software Lab
ITEM-24897
This Applied Biosystems 7500 Fast Real-Time PCR System was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested with the PC and software. It has been inspected by a service engineer and recertified.
There is a Dell Optiplex PC with monitor, keyboard & Mouse included with Life Version 2.3 7500 software installed on it. The machine also has a fresh install of Windows 7.
The 7500 has passed the following function tests:
USB
CCD
Filter Wheel
Shutter
Lamp
Thermal Cycler
All tests passed.
The lamp condition is described as 'good'. It has 13 hours of usage and the current is 5.604amps. It is reported as being replaced 02/07/2020.
The unit has not been calibrated as it requires an Applied Biosystems real-time PCR system spectral calibration kit

£ 9,050.00 (ex. VAT) 1 in stock
Applied Biosystems 7500 Fast Real-Time PCR System with PC & Software Lab
ITEM-24898
This Applied Biosystems 7500 Fast Real-Time PCR System with PC & Software was removed from a university lab where it was surplus to requirements.
The unit powers up and has been connected to the PC. It has been inspected by a service engineer who has re-certified it.
The PC is a Dell Optiplex PC with a monitor, keyboard & Mouse with Life Version 2.3 7500 software installed on it. The machine also has a fresh install of Windows 7.
The 7500 has passed the following function tests:
USB
CCD
Filter Wheel
Shutter
Lamp
Thermal Cycler
All tests passed.
The lamp condition is described as 'good'. It has 209 hours usage and the current is 5.597amps. It is reported as being replaced 06/24/2020.
The unit has not been calibrated as it requires an Applied Biosystems real-time PCR system spectral calibration kit

£ 7,315.00 (ex. VAT) 1 in stock
Fluidigm Biomark HD Genetic Analyser & IFC Controller HX RT-PCR qPCR Lab
ITEM-18023
Fluidigm Biomark HD Genetic Analyser & IFC Controller HX with Accessories
This was removed from a university lab where it was surplus to requirements.
The units are all in good cosmetic condition with marks from use. Everything powers up. Starting up various programs did trigger the main unit to open its side door ready for a sample so it does appear that the PC and main unit are communicating. We have not run samples on the instrument but all tests and software appear to be running as expected.
Lot contains:
1 x Fluidigm Biomark HD Genetic Analyser.
1 x Fluidigm IFC Controller HX.
1 x Dell Monitor.
1 x VGA Cable.
1 x Logitech Keyboard.
1 x USB Male to USB Female Cable.
1 x 9 Pin Male to 9 Pin Female Serial Cable (Not VGA).
We logged into the IFC Controller HX successfully.
Settings on controller say:
Serial No: HX-10641.
Chips Supported: 136, 138, 139, 153, 154.
Filmware Version: 53
Software Version: 2.7-2014-12-02.
Last System Check: 19/11/2021.
The PC built inside the Biomark HD Genetic Analyser has had the user data removed but the software remains
Fluidigm Software:
Genetic Analysis.
BioMarkICP
EP1
BioMark.

£ 6,415.00 (ex. VAT) 1 in stock
Stratagene MX3005P Multiplex Quantitative PCR System & Software Lab
ITEM-30456
This Stratagene MX3005P Multiplex Quantitative PCR System was removed from a university lab where it was surplus to requirements.
The unit has been tested by a service engineer who has deemed it to be fully working.
The main unit powers up and is in good used cosmetic condition but it does have some scrapes, scratches and marks from use.
The system includes:
1 x Agilent Stratagene MX3005P. (various marks from use)
1 x Dell Optiplex 7010 with keyboard, Mouse & Monitor.
The PC is running a fresh install of Windows 7. Also installed is a copy of Stratagene MxPro - Mx3005P v4.10 build 389. The software will control the Mx3005P unit. We have run a basic heat cycle with it and verified that the lamp will turn on & off.
The MX3005P has the following filters installed:
- CY5 - CY5 Filter Set - Excitation Wavelength(NM) 635 - Emission Wavelength(NM) 665.
- CY3 - CY3 Filter Set - Excitation Wavelength(NM) 545 - Emission Wavelength(NM) 568.
- ROX - ROX Filter Set - Excitation Wavelength(NM) 585 - Emission Wavelength(NM) 610
- HEX - HEX-JOE Filter Set - Excitation Wavelength(NM) 535 - Emission Wavelength(NM) 555
- FAM - FAM Filter Set - Excitation Wavelength(NM) 492 - Emission Wavelength(NM) 516

£ 6,390.00 (ex. VAT) 1 in stock
Bio-Rad C1000 Thermal Cycler with CFX96 Optics Module RT-PCR Lab
ITEM-20274
This Bio-Rad C1000 Thermal Cycler was removed from a university lab where it was surplus to requirements.
The item is in good cosmetic condition but there are some minor marks from prior use. There are no scratches or dents.
The item powered on without issue. It ran several self-tests and found no errors. The lid heating function works.
When set to 37˚C the thermometer measured 37.3˚C
When set to 100˚C the thermometer measured 98.2˚C

£ 5,000.00 (ex. VAT) 1 in stock
Affymetrix GeneChip Scanner 3000 System with Hybridization Ovens & Autoloader
ITEM-25299
Affymetrix GeneChip Scanner 3000 System with Hybridization Ovens & Autoloader
This was removed from a university lab where it was surplus to requirements.
The system powers up and the PC has the software installed. It connected to the system, and we were able to control the scanner from the PC.
Included are;
Affymetrix GeneChip Scanner & Autoloader
Top:-
Model - Autoloader
PN - 90-0351
SN - A07790
Bottom:-
Model - Scanner 3000
PN - 00-0073R
SN - 50202631
Powers on.
Affymetrix GeneChip Fluidics Station
Model - 400
PN - 800101
SN - FS1134
Powers on.
Affymetrix GeneChip Hybridization Oven
Model - 645
PN - 00-0331
SN - C0105100
Powers on with rotation speed up to 80rpm. The oven is in good working order.
Affymetrix GeneChip Hybridization Oven
Model - 640
SN - OVN 021550
Powers on with rotation speed running up to 85rpm. The oven is in good working order.

£ 4,880.00 (ex. VAT) 1 in stock
Chemagen Chemagic Magnetic Separation Module I + Software & Accessories Lab
ITEM-15259
Chemagen Chemagic Separation Module I with Software & Accessories
This was removed from a university lab where it was surplus to requirements.
Included in the system are;
1 x Chemagic Magnetic Separation Module I
10 x Tube Racks :-
7 hold 12 x 50ml tubes
2 Hold 12 x 15ml tubes
1 holds 12 x 0.5ml tubes
1 x Chemagen Biopolymer
Vulkan Technic
Order no. 200 03 014
The unit powers on but not tested further.
1 x Compaq PC
Model - Presario S0000
Chemagen/Chemagic Software MSM (Release 5.1.0.6) Installed
1 x DGM Monitor
Model - L-1731W
1 x Compaq Keyboard
1 x IBM Mouse
All PC equipment powers up and seems to be in full working order.
Boxed Accessories:-
178 x Genetix Lids (opened)
100 x Sealed 96 well 2.2ml storage plates
6 x Sealed Nunclon Surface plates
10 x Rubber plates
5 x 384 well plates (S300RXFL)
9 x 96 well 0.1ml slots
8 x 100mm Tissue Culture Dishes
11 x Chemagen Tubes (PK-400500-036-080403)
18 x Microcon YM-100 Regenerated Cellulose
38 x 2ml vials
17 Packs of MicroAmp Optical Caps (8 caps per strip, 12 strips per pack)
25 x Thermo Scientific 0.2ml Skirtled 96 well PCR Plates
57 x fisherbrand Dispenser Tips 12.5ml
Promega SV96 Total RNA Isolation System
2 x Denletstor Metal racks size 38.5 x 15.5cm, 160 squares 1.5 x 15cm each
2 x Wash Buffer 6 Bottles (both full) Volume unknown.
Promega Vac-Man Laboratory Vacuum Manifold

£ 4,400.00 (ex. VAT) 1 in stock
Roche LightCycler 480 II /96 PCR Real Time Thermal Cycler Lab RT-PCR
ITEM-20612
This unit was removed from a lab as surplus to requirements. The lab assured us it was in working order when last used, but we do not have a PC or software to test this instrument at our site.
In the testing we were able to carry out, the item powers on, both front lights were flashing orange. The microplate drawer also opened but we were unable to test it any further.
Item is in a good used cosmetic condition.

£ 4,065.00 (ex. VAT) 1 in stock
Applied Biosystems 7300 Real Time PCR System with PC & Software Lab
ITEM-30000
This Applied Biosystems 7300 Real Time PCR System was removed from a university lab where it was surplus to requirements.
The system is comprised of;
1 x Applied Biosystems 7300 Real-Time PCR Unit.
1 x Dell Optiplex 380 with Monitor, keyboard, mouse, USB cable & monitor cable.
Running Applied Biosystems Sequence Detection Software (SDS)
Version 1.2.3.
The Dell has a Fresh install of Windows XP.
The 7300 has had a function test run:
USB - Pass
CCD - Pass (version 2.19)
Filter Wheel - Pass (FW version G2.10)
Shutter - Pass (FW version G2.10)
Lamp - Pass (FW version G2.10)
Thermal Cycler - Pass (G2.10 Firmware is up to date)
The lamp status is Good.
It has 1444 Usage hours.
It was last replaced 08/01/2008.
The unit will require the ROI calibration.

£ 4,065.00 (ex. VAT) 1 in stock
Qiagen QIAcube Nucleic Acid Purification System Lab
ITEM-31315
This Qiagen QIAcube Nucleic Acid Purification System was removed from a university lab where it was surplus to requirements.
The unit powered up and we were able to run some pre-set programs. It ran these tests well. The lab has confirmed that it was functional prior to removal.
We ran a centrifuge program for 3 minutes which ran smoothly and we ran a shaker program for 1 minute which ran smoothly.
It is in good cosmetic condition with minor marks from use.
It comes with;
4 Boxes Filter Tips 1000ul (1024)
10 Boxes Rotor Adaptors (10 x 24)
4 Boxes Filter Tips 1000ul Wide bore (1024)

£ 4,055.00 (ex. VAT) 1 in stock
Qiagen PyroMark Q24 Sequencer System + Workstation Lab Pyrosequencing
ITEM-20525
This Qiagen PyroMark Q24 Sequencer System was removed from a university lab where it was surplus to requirements.
The lab assured us this unit was working, but as we understand it requires two USB sticks from Qiagen, which unfortunately the lab did not provide to us and have been unable to find. This lack of USB sticks explains the below issue. We have not yet got a quote on the USB sticks from Qiagen, but we are open to negotiation on price of this unit depending on the costs of getting these sticks to run the unit.
The unit powers up with the power supplies provided but we were unable to run it as it required a 'USB memory'. A message appeared on the screen saying
'Please insert USB memory' when pressing RUN, another message appears 'trying to access USB memory'. We assume it requires external software on a USB which is not included.
Versions:
Revision: E
Software 1.46901
Hardware 0.3.20
The unit has a 24-well block
Dimensions:
Dia 2.6ml x 4.8ml Dep
It is in good cosmetic condition with some minor marks from use.
Included with it are;
1 x XP Power supply
Model No. PCM80PS24 2547
The unit powers on and is in good cosmetic condition.
1 x XP Power supply
Model No. PCM80PS12
The unit powers on and is in good cosmetic condition.
1 x Qiagen PyroMark Workstation
Model PyroMark Q24 MDx

£ 4,050.00 (ex. VAT) 1 in stock
Agilent Stratagene Mx3005P Real-Time PCR System + PC & Software Lab
ITEM-18677
This Agilent Stratagene Mx3005P Real-Time PCR System was removed from a university lab where it was surplus to requirements.
The main unit is in reasonable used cosmetic condition but it does have some scrapes, scratches and marks from use.
The unit powers up and both Green LED's light. You can also feel the well block heating up. The well block is 96 hole.
The system includes:
1 x Agilent Stratagene MX3005P. (various marks from use)
1 x Dell E8400 PC with keyboard & mouse which we believe to be brand new.
1 x iiyama monitor. (various marks from use)
The PC has has a new HDD fitted and is running a fresh install of Windows 7. Also installed is a copy of Stratagene MxPro - Mx3005P v4.10 build 389. The software will control the Mx3005P unit. We have run a basic heat cycle with it and varified that the lamp will turn on & off. It has not been tested any further.
The PC comes with a brand new sealed keyboard & mouse and a used iiyama monitor is also included.
The system should include everything required to operate.

£ 3,890.00 (ex. VAT) 1 in stock
Applied Biosystems 7900HT Fast Real Time PCR System with 7067/4 Stacker Lab
ITEM-26003
This Applied Biosystems 7900HT Fast Real Time PCR System was removed from a university lab where it was surplus to requirements.
The system is in good used cosmetic condition.
We have powered the unit up and have been able to connect the unit to the PC but the software shows the serial number is invalid. It requires the 9 digit serial number from the rear of the main unit but it will only allow you to enter 6 digits!
We have spoken to Thermo who owns Applied Bioscience and they contacted a service engineer for us. The engineer said the issue can only be fixed with the engineer service tools, which could be done on-site post-purchase of this system.
It consists of the following parts:
1 x Applied Biosystems 7900HT
Part no. 4330966
SN - 279002990
1 x SICK CLV422-1910S02 Fixed barcode scanner
1 x AB 7067/4 Microplate stacker.
1 x Symbol Barcode Scanner.
1 x Dell Optiplex 960 PC with Dell Monitor, keyboard and mouse.
The has the following software installed:-
Applied Biosystems 7900HT Version 2.4 Sequence Detection Systems (SDS)
Applied Biosystems RQ Manager Version 1.2.1
We have all the passwords, which are available on request once the system has been sold.

£ 3,240.00 (ex. VAT) 1 in stock
Analytik Jena AlphaSC Samplerblock Thermal Cycler Lab
ITEM-29877
This Analytik Jena AlphaSC Samplerblock Thermal Cycler was removed from a university lab where it was surplus to requirements.
The unit powers up and runs.
It is in good cosmetic condition with marks from use.
48/R9-96/R4.5
340:720.14

£ 3,185.00 (ex. VAT) 1 in stock
Fluidigm C1 Single Cell Auto Prep System mRNA Sequencing Lab
ITEM-23408
This Fluidigm C1 Single Cell Auto Prep System was removed from a university la where it was surplus to requirements.
The unit powers up and the internal compressor is working. We were unable to test it fully without the standards set required.
It is in excellent cosmetic condition but has some minor marks from general use.

£ 3,000.00 (ex. VAT) 1 in stock
Thermo Hybaid MCA Melting Curve Analysis qPCR System Lab
ITEM-36229
Thermo Hybaid MCA Melting Curve Analysis qPCR System
This was removed from a university lab where it was surplus to requirements.
Item is in reasonable cosmetic condition with signs of damage such as residue and surface damage.
The item powers on with the front display light and fan in working order but we were unable to test it further.

£ 2,990.00 (ex. VAT) 1 in stock
Thermo Hybaid MCA qPCR Melting Curve Analysis System Lab
ITEM-36230
Thermo Hybaid MCA Melting Curve Analysis qPCR System
This was removed from a university lab where it was surplus to requirements.
Item is in reasonable cosmetic condition with signs of damage such as residue and surface damage.
The item powers on with the front display light and fan in working order but we were unable to test it further.
Items 1 to 20 of 120