Atomic Absorption Spectroscopy (AAS)
Items 1 to 6 of 6

£ 8,560.00 (ex. VAT) 1 in stock
Varian SpectrAA 220Z Atomic Absorption Spectrometer & Accessories
ITEM-31921
Varian SpectrAA 220Z Atomic Absorption Spectrometer & Accessories
This was removed from a university lab where it was surplus to requirements.
Included are;
Varian SpectrAA 220Z Atomic Absorption Spectrometer
SN - EL01065204
Varian Graphite Tube Atomizer
Model - GTA 110Z (100 Series)
SN - EL0106407
Varian UltrAA Lamps 1 & 2 Control Module
SN - EL97063260
Powers on
Varian VGA 77
SN - EL01114913
Powers on
Electrothermal Temperature Controller & Cell Heater MK2
Model - ETC060
SN - 94029227
Powers on and appears to be in working order with cell heater getting hot.
Varian Sample Dispenser
SN - EL01064640
Applied Thermal Control Chiller
Part no. KTD2000
SN - 010385
Powers on
Hollow Cathode Lamps by brand:-
Varian SpectAA Lamps:-
Mercury
Arsenic
Calcium/Magnesium/Aluminium
Cobalt/Chromium/Copper/Iron/Manganese/Nickel
Varian UltrAA Lamps:-
Lead
Selenium
Arsenic
Cobalt/Chromium/Copper/Iron/Manganese/Nickel
Silver/Cadmium/Lead/Zinc
12 x S&J Juniper:-
2 x Copper
1 x Nickel
1 x Tellurium
1 x Maganese
1 x Potassium
1 x Lead
1 x Zirconium
1 x Cadmium
1 x Zinc
1 x Iron
1 x Sodium
4 x Corning:-
1 x Zinc
1 x Cobalt
1 x Potassium
1 x Molybdenum
3 x Activion:-
1 x Iron
1 x Aluminium
1 x Sodium
3 x Southern Spectral Sources:-
2 x Neon
1 x Argon
ASL
11 X Neon
6 x Varian Techtron:-
Molybdenum
Tin
Copper
Lead
Nickel
Cadmium
1 x Southern Shandon Neon
1 x Baird Atomic Neon
2 x Neon Cathodeon
1 x Rank Hilger Neon
Box full of various small parts including tubing, cables and:-
Varian Kit Mixer Paddles MK7 Qty 5
Varian UV Lamp
3 x Varian Kit MK7 Aqueous Spray Chamber O ring
Varian Kit Neb Capillary for MK7
2 x Boxes of Glassware (99-1000400-00)
Box of Kit spares & tools (98-100239-00)
Box of 2 Glass Parts (66-100082-00)
Box of spares (02-101494-00)
Yellow Cell Heater Temperature Sensor PN - 01-106549-90
Software/Discs:-
SpectrAA Help & Videos
Varian Patches
Varian Atomic Spectroscopy Publications
Varian Windows Update
Varian SpectrAA Software Base
Varian SpectrAA Software Pro
Varian Basic Atomic Absorption Theory
Manuals:-
Varian SpectrAA Operation Manual
Varian OSI Optical Spectroscopy Instruments Log Book
Varian Atomic Absorption Maintenance Guide
Varian Atomic Absorption Technical Presentation
Varian Analytical Methods
Varian Techniques of Graphite Furnace AA Spectroscopy Course Manual
Varian Analytical Methods for Graphite Tube Atomizers
Varian AA Introducing Atomic Absorption Analysis
Applied Thermal Control Manual

RECERTIFIED ITEM
RECERTIFIED ITEM
£ 5,275.00 (ex. VAT) 1 in stock
Perkin Elmer AAnalyst 200 Atomic Absorption Spectrometer with Accessories Lab
ITEM-27543
This Perkin Elmer AAnalyst 200 Atomic Absorption Spectrometer was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested by an engineer. They did not use acetylene/air gas. The system is working fine and the detector responds to the change in the intensity of the light.
The HCL lamps have been tested and all powered up, though we are not sure of the age.
The PC is not in working order but the software is installed onto the AA itself and can be controlled with the touch screen. We have left the PC with the system in case it has any useful cards.
The system is in good cosmetic condition with marks from use.
Included are;
Perkin Elmer AAnalyst 200 Atomic Absorption Spectrometer
Part no. B3150050
Unit dimensions - D75 7W0 H66cm
Manuals:-
Analytical Methods for Atomic Absorption Spectroscopy folder
AAnalyst 200 Users and service guide
Used Hollow Cathode Lamps:-
6 x Perkin Elmer Lumina Lamps
16 x Varian
6 x SpectrAA
13 x S&J Juniper
6 x Instrumentation Laboratory
2 x Cathodeon
2 x Photron
3 x Pye Unicam
1 x ASL
1 x Varian Techtron
1 x Activation
1 x Spectronic
Please note, that some of the lamps in the photos have been removed from this listing. The following lamps are no longer included.
1 x Varian Arsenic
1 x Varian Chromium
1 x Varian Zinc
1 x Varian Mercury
1 x Instrumentation Laboratory Hollow Cathode Lamp
1 x S&J Juniper Lamp
1 x Perkin Elmer Pb
1 x Perkin Elmer Fe
1 x Perkin Elmer Ni

£ 1,375.00 (ex. VAT) 1 in stock
Job Lot 34x Hollow Cathode Lamps AAS Instrument Laboratory, Visimax, Philips Lab
ITEM-24529
Job Lot of 34 Hollow Cathode Lamps
This was removed from a university lab where it was surplus to requirements.
These have all been tested by a manufacturer trained engineer using a Varian SpectrAA Atomic Absorption Spectrometer Model - 220FS)) and these are the results for that (no further test have been done):
Photron Hollow Cathode Lamp - Element: Na, Sodium (PN-P852) SN-4589. Working
Visimax I Hollow Cathode Lamp - Element: Zn (Cat no-62311). Working
Visimax I Hollow Cathode Lamp - Element: Yb (Cat no-062983-00). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Chromium Cr. (Cat no-89211). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Cobalt, Co (Cat no-89212). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Selenium, Se (Cat no-89249). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Magnesium, Mg (Cat no-89230). not Working
Instrument Laboratory Hollow Cathode Lamp - Element: Maganese, Mn (Cat no-89231). Working
Philips Data Coded Hollow Cathode Lamp - Element: Sn (PN-9423 390 30501) SN - 37957. Working
Philips Data Coded Hollow Cathode Lamp - Element: Ca-Mg (PN-9423 393 31011) SN - 38083. Not tested
Philips Data Coded Hollow Cathode Lamp - Element: Hg (PN-9423 390 30801) SN - 37374. Working
Philips Data Coded Hollow Cathode Lamp - Element: Na (PN-9423 390 30111) SN - 28829. Working
Philips Data Coded Hollow Cathode Lamp - Element: Pb (PN-9423 390 30821) SN - 37759. Working
Philips Data Coded Hollow Cathode Lamp - Element: Cd (PN-9423 390 30481) SN - 37280. Working
Philips Data Coded Hollow Cathode Lamp - Element: D2 (PN-9423 390 30011) SN - 35732. not tested
Activon Hollow Cathode Lamp - Element: Calcium, Ca (SN-27775). not Working
Activon Hollow Cathode Lamp - Element: Molybdenum, Mo (SN-6603). Working
Activon Hollow Cathode Lamp - Element: Titanium, Ti (SN-5998). not tested
Cathodeon Hollow Cathode Lamp - Element: Cr (PN-3UNX/Cr) SN - 39998. Working
Cathodeon Hollow Cathode Lamp - Element: Ca (PN-3UNX/Ca) SN - 70591. Working
Cathodeon Hollow Cathode Lamp - Element: Fe (PN-3QNY/Fe) SN - 40895. Working
SIP Analytical Hollow Cathode Lamp - Element: Cd (Cat no-FL2176) Lamp no.20065 NOT WORKING
SIP Analytical Hollow Cathode Lamp - Element: Pb (Cat no-FL2172) Lamp no.20008 Working
SIP Analytical Hollow Cathode Lamp - Element: Ni (Cat no-FL2155) Lamp no.20081. Working
SIP Analytical Hollow Cathode Lamp - Element: H2 (Cat no-FL2159) Lamp no.20098. not tested
S&J Juniper Hollow Cathode Lamp - Element: Magnesium, Mg (Cat no-4132) SN-517009. Working
S&J Juniper Hollow Cathode Lamp - Element: Boron, B (SN-88541). Working
S&J Juniper Hollow Cathode Lamp - Element: Cadium, Cd (Cat no-4108) SN-514357. Working
S&J Juniper Hollow Cathode Lamp - Element: Lead, Pb (Cat no-4129V) SN-2936V. Working
S&J Juniper Hollow Cathode Lamp - Element: Aluminium (SN-88765). Working
S&J Juniper Hollow Cathode Lamp - Element: Copper, Cu (Cat no-4114V) SN-3325. Working
S&J Juniper Hollow Cathode Lamp - Element: Cu/Zn (Cat no-4289V) SN-3144V. Working
S&J Juniper Hollow Cathode Lamp - Element: Molybdenum, Mo (Cat no-4135) SN-513155. Working
S&J Juniper Hollow Cathode Lamp - Element: Molybdenum, Mo (SN-88612). Working

£ 1,335.00 (ex. VAT) 1 in stock
Solar Unicam 939 AA Spectrophotometer Type - 939CR/03 Lab
ITEM-27577
This Solar Unicam 939 AA Spectrophotometer was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to get it to communicate with the PC so it has not been tested. It is in reasonable cosmetic condition with marks from use.
Included with it are;
Unicam Regulator (connected)
4013 172 34566
Unicam AA Wash Facility
No. GE495504
Gilson Sampler
Model - 221-222
SN - 145440
Powers on

£ 460.00 (ex. VAT) 1 in stock
6 x Hollow Cathode Ray Lamps for AA System S&J, Philips, Varian, Photron Lab
ITEM-32082
These were removed from a university lab where it was surplus to requirements.
We were unable to test these.
Included are;
1x S&J Juniper Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318.5
Cat/N: 4166
S/N: 901315
1x S&J Juniper Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318.5
Cat/N: 4166
S/N: 2123E
1x S&J Juniper Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318
S/N: 3535
1x Philips Data Coded Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318.5
Cat/N: 9423 390 30231
S/N: S 64401
1x Varian Techtron Hollow Cathode Lamp
Element: Zink
Cat/N: 4N559
1x Photron Hollow Cathode Lamp
Element: Tellurium
Wavelength: 214.3
Cat/N: 4166
S/N: 2437

£ POA 1 in stock
Perkin Elmer AAnalyst 200 Atomic Absorption Spectrometer
ITEM-36287
This item is new in stock. Please enquire for further details.
Items 1 to 6 of 6