Our Flow Cytometry category offers a selection of high-quality, second-hand equipment designed for precise cell analysis and sorting. Specializing in flow cytometers, cell analyzers, and accessories, our range is ideal for laboratories and research facilities involved in immunology, cancer research, and cell biology.


Equipment undergoes varying levels of testing, including functionality checks and performance assessments, ensuring dependable performance for your flow cytometry applications.

Items 1 to 32 of 32

Image of Beckman Coulter MoFlo Astrios EQS Flow Cytometer System & Sterilgard Cabinet Lab

£ 20,000.00 (ex. VAT) 1 in stock

Beckman Coulter MoFlo Astrios EQS Flow Cytometer System & Sterilgard Cabinet Lab

ITEM-31544

Beckman Coulter MoFlo Astrios EQS Flow Cytometer System & Sterilgard Cabinet


This was removed from a university lab where it was surplus to requirements.


The PC with the system cannot run the software. The software is included but will require a Beckman OEM PC system to run.


The unit has the following lasers installed:


1 X 640NM - 106MW.

1 x 592NM - 200MW.

1 X 561NM - 202MW.

1 x 532NM - 150MW.

1 x 488NM - 200MW.

1 X 405NM - 55MW.


The writing is quite faint on the MW output, so the above figures might not be 100% correct.


The complete system consists of:


1 x Baker Company SG503HE-BC-INT SterilGARD hood.

Manufactured 04/13/2015.

The unit has been powered up.


1 x Moflo Astrios EQS Main Unit.

The unit has various marks and scratches from general use. It powers up fine.


1 x Moflo Astrios Lower/Laser/Computer Section.

The laser & computer system power up fine.


Image of Beckman Coulter MoFlo Astrios EQS Flow Cytometer System & Sterilgard Cabinet Lab

£ 18,000.00 (ex. VAT) 1 in stock

Beckman Coulter MoFlo Astrios EQS Flow Cytometer System & Sterilgard Cabinet Lab

ITEM-31566

MoFlo Astrios EQS Cell Sorter in BSL Hood.


All units are in good used cosmetic condition.


The system powers up as it should.


We were informed by the lab that the Red laser is faulty and requires replacement.


The unit has the following lasers installed:


1 X 640NM - 106MW.

1 X 561NM - 202MW.

1 x 488NM - 200MW.

1 X 405NM - 55MW.


The writing is quite faint on the MW output, so the above figures might not be 100% correct.



The complete system consists of:


1 x Baker Company SG503HE-BC-INT SterilGARD hood.

Manufactured 09/30/2013.


1 x Moflo Astrios EQS Main Unit.

The unit has various marks and scratches from general use.

Powers up fine.


1 x Moflo Astrios Lower/Laser/Computer Section.

The laser & computer system powers up fine.


1 x Thermo/Haake SC100/A28 re-circulator/chiller.

Powers up fine.


1 x Intellipower UPS.

Powers up fine.


1 x Jun-Air OF302 Silent Air Compressor.

It was noted by the lab that this is quite loud. We powered it on and it sounds normal for one of these units.


Also includes various spares and accessories shown in pictures.

3 x '100' spare nozzle tips

8 x '70' spare nozzle tips.

Image of Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab

£ 15,000.00 (ex. VAT) 1 in stock

Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab

ITEM-44681

Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab


This system was removed from a university where it was surplus to requirement.


It is in good cosmetic condition, the working condition of each unit that we were able to test is listed below.


Parts of the system:-


Optics Table - MoFlo Optical Bench

SN - 2086

Dimensions - L153 W122 H80.5cm

Measurement - Imperial


Parts fitted on table:-


Pressure Console Unit

SN - 2086


Coherent Sapphire

Model - Sapphire LP USB CDRH Driver Unit w/display

PN - 1189089

SN - LDP.1189089.C02070

  1. Powers on

Coherrent Sapphire 488-200 CW CDRH

PN - 1137970

SN - LDP.1137970.521683

Heatsink Sapphire LP RoHS compl

  1. NOT TESTED

Coherrent Cube

PN - 1170509

SN - C20010803

  1. NOT TESTED

Coherrent Cube

PN - 1193821/AA

SN - C14070901

  1. NOT TESTED

Hamamatsu Parts:-

H957-27 (No.T0050)

H957-18 (No.K0149)

H957-27 (No.T3721)

H957-25 (No.S0319)

H957-25 (No.S0360)

H957-25 (No.S0359)

H957-25 (No.S0322)

H957-25 (No.S0324)

H957-27 (No.T0051)

H957-27 (No.T0054)

H957-25 (No.S0358)

H957-25 (No.S0321)

H957-25 (No.S0323)


Smart Sampler


2 x Preamplifier Units

SN - 2086


DTx Data Display 19" LCD w/Touchscreen

BCI PN - B44222

DTx PN - 90819

SN - BCM0514F37003

  1. Powers on via Miami MoFlo XDP Controller

Under table units:-


DTx BCI Miami MoFlo XDP Controller

DTx PN - 90692

BCI PN - B20566

DTx SN - BCM0915F44602

  1. Powers on - When powered up, an error message reads 'OdinInstControl::connectMachine failed: AttachedInstrument::GetInstance:Repository had communication error!'

Gast Vacuum Pump

DOA-P501-BN

  1. Powers on

Intellipower UPS

Model - IQ200V-C-DiAC-Isol-PFC

SN - 2FKVDIFC5B15110524

  1. Powers on

Beckman Coulter Aerosol Evacuation System Buffalo Filter w/ Pedal

Model - 200-0179

SN - 502135

Has ViroSafe Filter fitted (PN-200-8166)

  1. Powers on.

3 x 316L UM Alloy Products Corp Pressure Vessels:-

SN - S533735-1-005 (2014)

SN - S514233-1-011 (2010)

SN - S507165-1-008 (2008)


Other units:-


Thermo Scientific Recirculating Water Bath

Control - C10 Type - 003-5009/SN - 1 08004133017

Bath - K20 Type - 002-4276/SN - 08004052 003

  1. Powers on

Testing:-

37˚c - Thermometer read 37.6˚c

100˚c - Thermometer read 100.0˚c

-20˚c - Thermometer didn't read lower than -13.5˚c


Jun Air Compressor

Type - OF302-25MQ

SN - 0119802962

  1. Powers on with compressor running

Hours - 00898.3


Other spare bits:-

1 x Black Case of various filters

1 x Black Case containing 3 x Merlin Gerin fuses, Methanol & Acetone

2 x Sets of Spare Shaped Charged Plates (one pair boxed)

1 x Box of Filters

1 x Box of mixed size O-rings

Red Ethernet cable

5 x IEC Extension cables

Image of Becton Dickinson BD LSRFortessa Cell Analysis System with Accessories Lab

£ 13,515.00 (ex. VAT) 1 in stock

Becton Dickinson BD LSRFortessa Cell Analysis System with Accessories Lab

ITEM-30341

This Becton Dickinson BD LSRFortessa was removed from a university lab where it was surplus to requirements.


The lab informed us it was in full working order prior to removal.


Included are;

1x BD LSRFortessa Model No 649225B1

The unit powers on and is in good cosmetic condition. The fans are working and air can be felt blowing away from the unit.


1x ONEAC Power supply:

Model PCM1500U-CPBB

The unit powers the BD LSRFortessa unit. It is in good cosmetic condition. There are some light tape marks from general use.


1x BD High throughput Sampler:

Cat No. 647701

The unit powers on and is in good cosmetic condition.


1x BD FACSflow Supply System:

Ref, 349227

The unit powers on and is in good cosmetic condition.


1x Nalgene Bottle:

Volume, 2L

The unit is in good cosmetic condition.


1x BD Closed Waste Container:

The unit is in good cosmetic condition.



Image of BD Becton Dickinson LSR II Flow Cytometer Lab

£ 10,470.00 (ex. VAT) 1 in stock

BD Becton Dickinson LSR II Flow Cytometer Lab

ITEM-36938

BD Becton Dickinson LSR II Flow Cytometer


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further without a PC and software. The lab informed us when it was last used a few years ago, it was still working.


The unit is in overall good cosmetic condition with marks from use. There is a crack in the front and the right-hand cover and the left-hand door doesn't close fully.


2 x One AC

Model - CBS2120

PN - 011-526

SN - 0129 - 6308/0129-6304


Becton Dickinson Closed Waste Container


Alloy Products Corp 316L Waste Container (Lid doesn't fit)

SN - 115443-007


Table not included.


Image of Life Technologies Attune NxT Acoustic Focusing Cytometer AFC2 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 10,000.00 (ex. VAT) 1 in stock

Life Technologies Attune NxT Acoustic Focusing Cytometer AFC2 Lab Spares/Repairs

ITEM-41482

Life Technologies Attune NxT Acoustic Focusing Cytometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition externally, we are unable to power it on or test it further as the power supply is not included.


The lab confirmed the bleach had been run through it and it has corroded inside. A number of parts have been replaced in an attempt to save it, including the flow cell, but ultimately it was written off, however, it may still be fixable or useful for the valuable parts inside.


It is listed as Spares/Repair.


It also includes the following:


  1. Various replacement parts and screws
  2. 2 x Ball end syringe

Image of BioMerieux Chemunex Chemscan RDI Advanced Flow Cytometer Lab

£ 7,325.00 (ex. VAT) 1 in stock

BioMerieux Chemunex Chemscan RDI Advanced Flow Cytometer Lab

ITEM-35297

BioMerieux Chemunex Chemscan RDI Advanced Flow Cytometer


This was removed from a university lab where it was surplus to requirements.


The system powers up and is in good cosmetic condition with minor marks from use.


There is a joystick and a keypad supplied.


There is no PC or software included.

Image of BD Influx 646500 Cell Counter/Flow Cytometer Full System Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 6,000.00 (ex. VAT) 1 in stock

BD Influx 646500 Cell Counter/Flow Cytometer Full System Spares/Repairs

ITEM-39768

BD Influx 646500 Cell Counter/Flow Cytometer Full System *Parts Only*


This system is sold strictly for parts only. The system has failed inspection due to exposed lasers.


The client we are selling this unit for has requested a disclaimer stating the unit can only be used for parts and spares/repairs. This is because of concerns over the exposed lasers.


Any buyer must be willing to sign this disclaimer.


BD Influx 646500 Cell Counter/Flow Cytometer

Model: BD Influx Cell Sorter 646500U1

Date: JUL 2009

Serial#: X0U100001


Item sits on:

TMC 'Metric' Vibration isolation table

Part#: 77-35471-01


Item contains the following:

Western Digital WD VelociRaptor

Serial#: WXL209036130


Cobolt Jive 75 (Qty.2)

Serial#: 2615


JDSU CY-355-100

Date: 2008

Serial#: 06460


Coherent Sapphire CDRH HP

Date: 2009

Serial#: P0209-009627


Pavilion Integration Corp WhisperIT (Qty. 2)

Model: WCP638E-120FS-002

Date: 2015

Serial#: LD 638 #3069


Hamamatsu R9110 Photomultiplier Tube (Qty. 16)

Model: C6270

Serial: 528049


SMC AFM20-N02-CZ-A mist separator (Qty. 4)

Model: AFM20-N0-CZ


JDSU CY-PS

Date: 2008

Serial#: 06650


Acopian Power Supply.



PC, Montior's, Keyboards & Mice


HP Z400 Workstation PC

Serial#: 2UA04920P7


Dell 2007FPb Monitor

Serial#: 052605-11


NEC Lcd Monitor MultiSync LCD2490WUXi2

Serial#: 060852-00


HP Mouse & Keyboard


Dell Mouse & Keyboard


All items above are in good cosmetic condition and full working order.


Unable to check PC's content due to Password protection.



                


Ekom Oil Free Compressor / Vacuum Unit

Model: DK50-10S/M-RO-3V

Serial#: D2675-05-2015


Item is in good cosmetic condition.

Untested.

Hour counter displays: 495.60


Tektronic TDS 2014B Four Channel Oscilloscope

Serial#: TDS 2014B C041608


Item is in good cosmetic condition.

Untested.


Bridgeport Magnetics ISO-Puck Isolation Transformer

Model: ISO PUCK


Item is in good cosmetic condition.

Untested.


Data Transfer Switch


Item is in good cosmetic condition.

Untested.


Spectral Products CM110 1/8mm Monochromator



Parts & Accessories.


Seath Line

Serial#: 04-41024-01


Seath Line (Qty. 4)

Part#: 645230


Filter DCM 3 in DIA

Part#: 343540


Filter DCM

Part#: 645268


Washer (Qty.2)

Part#: 645264


Washer (Qty.2)

Part#: 343615


Washer (Qty.2)

Part#: 645242


Sartorius

Ref: 645270


Swagelok (Qty.10)

Part#: SS-200-NFSET


Influx 430mm (Qty.4)

Part#: 645228


Seath Line

Part#: 645242


FACS Nozzles x 4

Part#: 165416

Cytopia TIP 200

Cytopia TIP 140

Cytopia TIP 100

Cytopia TIP 70


Fixing (Qty.2)

Part#: 645270


Washer (Qty.2)

Part#: 645242


Order#: HPK2013070808390003

Part#: 645383


CM110 Slit Set


Various metal fixing/brackets.


BPS2 250


Manuals/Software:


Cyte Power Supply User's Manual


Roxio Creator 9.0 DE Disc


Coherent Sapphire 488-200 CDRH Operator's ManuaL


MFG, NI-DAQMX Documentation and SW Combo Kit Ver 8.7.1

Part#: 778837v-031


Jun-Air 5um Filter Installation and Maintenance Instructions


Cobolt Test Protocol for:

Cobolt Jive 75mW


Coherent CUBE Lazer System Operator's Manual.


Jun-Air Compressor User's Manual


NI LabVIEW SignalExpress Tektronic Edition

Interactive Measurements Software v2.5


TDS100B Digital Storage Oscilloscope User Manual


Tektronix P2220 Passive Probe (Qty.3)

Date: 2008

Serial#: 010-0728-72


Spectral Products Demonstration Software and User Manuals


MI945X Intel Core 2 Duo/GM45

Mini-ITM Motherboard User's Manual


DK50-10S/M-RO-3V Instructions for Use Service Manual


BD Influx Safety and Limitations Manual

Image of Beckman Coulter CytoFLEX B3-R2-V2 Flow Cytometry Analyser Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 5,000.00 (ex. VAT) No longer available

Beckman Coulter CytoFLEX B3-R2-V2 Flow Cytometry Analyser Lab Spares/Repairs

ITEM-35910

*no stock location - currently awaiting return*


Beckman Coulter CytoFLEX A00-1-1102 Flow Cytometry Analyser


This was removed from a working lab where it was surplus to requirements.


It powers up, but we are unable to test it further due to some issues identified by a Beckman Coulter engineer. As a result, it's being sold as Spares/Repair.


The unit is in good cosmetic condition, but it has a few minor marks on the exterior.


It was inspected by a Beckman Coulter Engineer on 09/09/2024 who concluded and advised the following:


  1. There is a blockage, indicating issues with the Flow Cell as there is a leak, cannot get any sample/beads through.
  2. It's not mixing.
  3. Issues with one of the motors.
  4. Laser powers up, but as the beads are not passing through it can't be tested.
  5. Also, the lasers have an error message that they are not within the correct power range. This could be a result of no sample/beads being able to pass through, but they cant not be certain.

It needs


  1. New Flow Cell
  2. New Motor
  3. New Pump
  4. Licensing key

Includes:


1 x CytoFLEX Plate Holder

1 x Sheath Fluid Fluidics Harness

1 x Waste Fluidics Harness

1 x User guide


7 detectors, 3 lasers, 16 filters.


Model number- A00-1-1102

Serial number- BB12094

Image of Miltenyi Biotec autoMacs Pro Separator System Lab

£ 3,000.00 (ex. VAT) 1 in stock

Miltenyi Biotec autoMacs Pro Separator System Lab

ITEM-44488

Miltenyi Biotec Auto Macs Pro Separator System Lab


This system was removed from a university lab where it was surplus to requirements.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


This system does not include the required Fluid Bottles, which are available for purchase from the manufacturer's website.

Image of Millipore Guava EasyCyte 8HT Flow Cytometer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 2,530.00 (ex. VAT) 1 in stock

Millipore Guava EasyCyte 8HT Flow Cytometer Lab Spares/Repairs

ITEM-30464

This Millipore Guava EasyCyte 8HT Flow Cytometer was removed from a university lab where it was surplus to requirements.


The system powers up and is in good cosmetic condition with only minor marks from use.


The unit has been tested with samples but was showing readings of 200-300 when it should be showing readings of around 50000. We were unable to diagnose the exact fault.


The unit has a Dell Optiplex 7010 PC paired with it. The PC includes a keyboard, mouse, monitor, USB and VGA Cable. It has had a brand new copy of 32bit Windows 7 installed.


Guavasoft 3.1 has also been installed, which includes:

ViaCount.

InCyte (This requires an unlock code from Millipore to run).

easyCheck.

Guava Clean 3.1.


We have been able to open and close the sample tray. This proves that the system is fully connected.


It is sold for spares/repairs.

Image of BD Accuri C6 Flow Cytometer CSample Lab

£ 2,000.00 (ex. VAT) 1 in stock

BD Accuri C6 Flow Cytometer CSample Lab

ITEM-44587

BD Accuri C6 FlowCytometer CSampler


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further at our facility.


It is in excellent cosmetic condition with minor marks.


The power supply is included.


Included additionally are;


2 x Large plastic bottles


2 x Small plastic bottles


1 x BD grip mat


1 x BD Accuri C6 Software User guide


1 x BD Accuri Safety and limitations


1 x BD Accuri Instrument Manual

Image of BD Accuri C6 Flow Cytometer Lab

£ 2,000.00 (ex. VAT) 1 in stock

BD Accuri C6 Flow Cytometer Lab

ITEM-44435

BD Accuri C6 Flow Cytometer


This system was removed from a university lab where it was surplus to requirements.


The unit is in good cosmetic condition and powers on with all lights and buttons functioning.


No further testing has been conducted due to the absence of software.


The power supply is included.


Also included:


  1. 2x Large Waste Bottle
  2. 2x Small Waste Bottle

Image of Accuri C6 Flow Cytometer Lab

£ 2,000.00 (ex. VAT) 1 in stock

Accuri C6 Flow Cytometer Lab

ITEM-41640

Accuri C6 Flow Cytometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


This item has been tested with an in-house 12v power supply. (not included).



Image of BD Accuri C6 Flow Cytometer CSampler Lab

£ 2,000.00 (ex. VAT) 1 in stock

BD Accuri C6 Flow Cytometer CSampler Lab

ITEM-36216

BD Accuri C6 FlowCytometer CSampler


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further at our facility.


It is in excellent cosmetic condition with minor marks.


Included additionally are;

BD Accuri C6 Software Disk

BD CSampler Software Disk

Dell P1914S Drivers and Documentation Disk

BD Accuri Allen key assembly tool

BD Accuri C6 Flow Instrument Manualn

BD Non slip mat

24-tube rack for standard 12 x 75-mm tubes


BD Accuri C6 FlowCytometer CSampler

Model: C6 BD CSampler

Serial#: 5202

Release Date: Feb 2014


Image of BD Biosciences ACCURI C6 Cell Sorter System Lab

£ 2,000.00 (ex. VAT) 1 in stock

BD Biosciences ACCURI C6 Cell Sorter System Lab

ITEM-25259

This BD Biosciences ACCURI C6 Cell Sorter System was removed from a university lab where it was surplus to requirements.


The unit powers up but as there were no software discs or testing solutions with it we had our service engineer observe the system initialising without the cover on. They reported that it initialised as it should.


It is in very good cosmetic condition with only minor marks from use.


Image of BD Biosciences ACCURI C6 Cell Sorter System with Software Lab

£ 2,000.00 (ex. VAT) 1 in stock

BD Biosciences ACCURI C6 Cell Sorter System with Software Lab

ITEM-21214

This ACCURI C6 Cell Sorter System was removed from a university lab where it was surplus to requirements.


The unit had previously been in use up until the day it was removed. It was replaced with a new system. It is fully working.


The unit powered on with no problems at our facility. It is in excellent cosmetic condition.


It comes supplied with the PSU, USB lead, software CD, manuals and data books.




Image of Luminex 200 Multiplex Assy System with XYP lab

£ 1,775.00 (ex. VAT) 1 in stock

Luminex 200 Multiplex Assy System with XYP lab

ITEM-35766

Luminex 200 Multiplex Assy System with Luminex SD & XYP


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further at our facility.


It is in good cosmetic condition with marks from use.


Included are;


Luminex 200

Model: 200

Serial#: LX10007082403


Luminex XYP

Model: XYP

Serial#: LXY07085103



Image of BD FACSCalibur Flow Cytometer with Mac & Software Lab

£ 1,500.00 (ex. VAT) No longer available

BD FACSCalibur Flow Cytometer with Mac & Software Lab

ITEM-31321

BD FACSCalibur Flow Cytometer with Mac & Software


This was removed from a university lab where it was surplus to requirements.


The unit powers up and communicates with the software. It has not been tested further.


It is in reasonable cosmetic condition but is quite rusty


Spare parts:-

2 x Old PSI Units (Condor HCBB75W-A+)

4 x Waste containers


PC Equipment:-

Mac and NEC 19" Monitor with Apple Keyboard & Mouse.


Manuals/Software:-

BD Immunocytometry Systems Folder

FACS Vantage SE Training Folder

FACS Vantage SE Operator Training

BD 'From Genes to Proteins to cells' folder

2 x BD Immunocytometry Systems Boxed with CELLQuest software (Floppy discs) Reference Manual

BD Immunocytometry Systems Boxed with Paint A-Gate software (Floppy discs)

BD Biosciences Software Users Guide

BD Biosciences Instrument Users Guide

2 x FACStation Software Version 3.4 Discs

BD FACStation G4/G5 Restore OS 10.4.2

USB Dongle


Image of BD FACSCalibur System Flow Cytometer Cell Sorter System Lab

£ 1,175.00 (ex. VAT) No longer available

BD FACSCalibur System Flow Cytometer Cell Sorter System Lab

ITEM-23423

BD FACSCalibur System Flow Cytometer Cell Sorter System


This was removed from a university lab where it was surplus to requirements. Everything powers up but we could not get the system to communicate with the PC. It was not tested further.


It is in reasonable cosmetic condition with marks from use. Some parts of the system have quite a bit of rust.


1x BD FACSCalibur Flow Cytometer

Ref 342975

Manufacture date: May 2008

Ser no. E97501016

When opening the lid of the unit some washers are loose inside and an IEC connector is not attached to anything.


1x BD Power Supply;

Cat no. 34002910


Ser no. TE 3679

220V -117V 50-60Hz


1x Apple Mouse:

Model, M5769


1x Apple Keyboard

Model, A1243


1x Keyspan

Part no. USA-19HS


1x NEC Monitor:

Model LCD1970NXp-3


1x Mac Pro Tower:

Model A1186


Software:

There is no password required to open the programs


1x FLOWJO version 9.4.10

1x FLOWJO version 8.8.7

1x FLOWJO version 8.8.2



Cables:


1x VGA cable:

1x BD to Mac Controller cable:

1x Mac Pro power cable:


1x Metal Holder/Stand:



Image of BD FACSCalibur Flow Cytometer System Lab

£ 1,000.00 (ex. VAT) No longer available

BD FACSCalibur Flow Cytometer System Lab

ITEM-23424

This was removed form a university lab where it was surplus to requirements.


The unit powers up but has not been tested further.


It is in reasonable cosmetic condition but has rust and marks from use.

Image of Beckman Coulter TQ-Prep Workstation Model 2428 Lab

£ 900.00 (ex. VAT) 1 in stock

Beckman Coulter TQ-Prep Workstation Model 2428 Lab

ITEM-38326

This Beckman Coulter TQ-Prep Model 2428 was removed from a university lab where it was surplus to requirements.


The unit is in good cosmetic condition but has some minor marks from use.


It powers up, but we are unable to test it further at our facility.

Image of BD FACSCalibur Flow Cytometer System w/ Cellquest Pro Software

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 510.00 (ex. VAT) No longer available

BD FACSCalibur Flow Cytometer System w/ Cellquest Pro Software

ITEM-39858

BD FACSCalibur Flow Cytometer


This was removed from a university lab where it was surplus to requirements.


The unit has a main board issue and is sold for spares/repairs

Image of BD FACSCalibur Flow Cytometer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

BD FACSCalibur Flow Cytometer Lab Spares/Repairs

ITEM-31320

BD FACSCalibur Flow Cytometer


This was removed from a university lab where it was surplus to requirements.


The unit has a main board issue and is sold for spares/repairs

Image of Beckman Coulter Epics XL.MCL Cell Counter Flow Cytometer 4 Colour Lab

£ 500.00 (ex. VAT) 1 in stock

Beckman Coulter Epics XL.MCL Cell Counter Flow Cytometer 4 Colour Lab

ITEM-16944

This Beckman Coulter Epics XL.MCL Cell Counter was removed from a university lab where it was surplus to requirements.


The system powers up but has not been tested further.


It is in good cosmetic condition but has some marks from use.

Image of BD Accuri C6 Flow Cytometer Lab Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) No longer available

BD Accuri C6 Flow Cytometer Lab Spares/Repair

ITEM-44851

BD Accuri C6 Flow Cytometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition, but are we unable to test it further as it does not include a power supply.


This item is sold as seen without all original components present. Therefore, it is listed as Spares/Repair. the former user told us there were parts missing but were unable to confirm what.


Also includes the following:



  1. Manual
  2. Software
  3. Calibration certificate

Image of BIO-RAD Bio-Plex System, Luminex XYP & Luminex 100 Multiplex Lab

£ 300.00 (ex. VAT) 1 in stock

BIO-RAD Bio-Plex System, Luminex XYP & Luminex 100 Multiplex Lab

ITEM-39971

This BIO RAD Bio-Plex System, Luminex XYP & Luminex 100 Multiplex was removed from a university lab where it was surplus to requirements.


The system powers on and is in a reasonably good cosmetic condition, we're unable to test it further at our facility.


System includes:


BIO RAD Luminex XYP

Model: Luminex XYP

Serial#: LXY05066104


BIO RAD Luminex 100

Model: Luminex 100

Serial#: LX1000503501


Image of Luminex 100 Liquid Array Multiplexing System XYP Lab

£ 220.00 (ex. VAT) 1 in stock

Luminex 100 Liquid Array Multiplexing System XYP Lab

ITEM-25260

This Luminex 100 Liquid Array Multiplexing System was removed from a university lab where it was surplus to requirements.


Top unit:-

Model - Luminex 100


Bottom unit:-

Model - Luminex XYP


Both units powered on but we were unable to test them without the required software.


The system is in a reasonable, used cosmetic condition with marks and stains.


Image of Becton Dickinson FACScan Fluorescence Activated Cell Analyzer & Transformer Lab

£ 100.00 (ex. VAT) 1 in stock

Becton Dickinson FACScan Fluorescence Activated Cell Analyzer & Transformer Lab

ITEM-16796

Beckman Coulter FACScan Fluorescence Activated Cell Analyzer & Transformer


This was removed from a university lab where it was surplus to requirements.


The unit is in good cosmetic condition but has some marks from use.


It powers up using the supplied transformer but has not been tested further.




Image of BD FACSCanto II Flow Cytometer System w/ Fluidics Carts, PC & Software Lab

£ POA 1 in stock

BD FACSCanto II Flow Cytometer System w/ Fluidics Carts, PC & Software Lab

ITEM-37241

This item is new in stock. Please enquire for further details.

Image of Becton Dickinson BD LSR II Flow Cytometer w/FACSFlow Supply System Lab

£ POA 1 in stock

Becton Dickinson BD LSR II Flow Cytometer w/FACSFlow Supply System Lab

ITEM-37226

This item is new in stock. Please enquire for further details.

Image of BD FACSCanto Flow Cytometer System w/ Fluidics Carts, PC & Software Lab

£ POA 1 in stock

BD FACSCanto Flow Cytometer System w/ Fluidics Carts, PC & Software Lab

ITEM-37240

This item is new in stock. Please enquire for further details.

Items 1 to 32 of 32

Filters

Price (£)

to

Condition

Brand