Our FTIR Spectroscopy category provides high-quality, second-hand Fourier Transform Infrared (FTIR) spectrometers designed for molecular analysis. Specializing in mid-IR and far-IR applications, our range is ideal for laboratories working in chemical analysis, material science, and pharmaceutical research.


Equipment undergoes varying levels of testing, including functionality checks, ensuring reliable solutions for your FTIR spectroscopy operations.

Items 1 to 9 of 9

Image of Gasmet FT-IR Gas Analyser Spectrometer  Model - DX4030 Lab

£ 11,425.00 (ex. VAT) 1 in stock

Gasmet FT-IR Gas Analyser Spectrometer Model - DX4030 Lab

ITEM-30475

This Gasmet FT-IR Gas Analyser Spectrometer Model - DX4030 was removed from a university lab where it was surplus to requirement.


The unit powers up and we have run a hardware check.


Acceptable values for hardware parameters:


Cell temp: close to ambient temp

Cell pressure: close to ambient pressure

Source intensity: >50% (original =100%) - Unit showed 89%

Interf height: >3V when cell is filled with zero gas (original approx 5.5V - Unit showed 3.57V

Interf center: 2000...3000 point - unit showed 2483 points

Electronic temp: 0...50ºC - unit showed 21.43

Detector temp: -37ºC - Unit showed -37.08ºC

Ext detector temp: +25ºC - Unit showed 19.82ºC


Nothing seems out on the acceptable values for the hardware parameters.


We then ran the Zero Calibration check after flushing the air for 3 minutes.

The unit showed - Min: 115.0000 Max: 58825.0000

Acceptable values for Maximum background spectrum are >40 000 or >70% of original.


The system is in good cosmetic condition but has some minor marks from use.


It comes in Hardigg Storm Case with:-

2 x Gasmet Battery Units

Gasmet Software CD

Quantitech Dongle

Gasmet Dongle

Gasmet DX4030 Quick Reference Cards

2 x Black carry cases





Image of Varian 7000 FT-IR Spectrometer with FTS 6000 Power Supply Lab

£ 5,240.00 (ex. VAT) 1 in stock

Varian 7000 FT-IR Spectrometer with FTS 6000 Power Supply Lab

ITEM-36952

Varian 7000 FT-IR Spectrometer with FTS 6000 Power Supply


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further without the software.


It is in good cosmetic condition with marks from use.


Included are;


Varian Spectrometer

Model - 7000 FT-IR

SN - 46040-409


Varian Power Supply

Model - FTS 6000

SN - PS-0391-0806


Image of Thermo Nicolet Avatar 360 FTIR System with PC & Software Lab

£ 3,000.00 (ex. VAT) 1 in stock

Thermo Nicolet Avatar 360 FTIR System with PC & Software Lab

ITEM-17039

This Thermo Nicolet Avatar 360 FTIR System was removed from a university lab where it was surplus to requirements.


The lab assured us it was in working order prior to collection, but unfortunately, the Power supply was not supplied with the system, and is not included.


The PC powers on and has the following software on it.


Python 25

ARCGIS

MiniTab 15

Blue J

AsyMetrix.


The system is in reasonably good cosmetic condition but has marks from age and use.

Image of Shimazdu IRAffinity-1S Fourier Transform Infrared Spectrophotometer Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 2,500.00 (ex. VAT) 1 in stock

Shimazdu IRAffinity-1S Fourier Transform Infrared Spectrophotometer Lab Faulty

ITEM-41650

IRAffinity-1S Fourier Transform Infrared Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


We are told the instrument is technically working, but it needs some parts replaced. For this reason it is sold for spares/repairs.

Image of Bruker Vector 22 FTIR Spectrometer Lab

£ 1,750.00 (ex. VAT) 1 in stock

Bruker Vector 22 FTIR Spectrometer Lab

ITEM-42053

Bruker Vector 22 FTIR Spectrometer


This system was removed from a university laboratory where it was surplus to requirements.


The unit powers on and is in good condition with minimal wear. However, the software and PC are not included, therefore, no further testing has been conducted.


Specifications:

  • Type: I 19300
  • Serial No.: V221670

Included Manuals:

  • Bruker Opus NT Opus/IR Getting Started, Version 3
  • Bruker Opus NT Opus/IR Reference Manual, Version 3
  • Bruker Opus NT Opus/IR Programming, Version 3

Image of Perkin Elmer Spectrum GX FT-IR System Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,190.00 (ex. VAT) 1 in stock

Perkin Elmer Spectrum GX FT-IR System Lab Spares/Repairs

ITEM-26030

This Perkin Elmer Spectrum GX FT-IR System was removed from a university lab where it was surplus to requirements.


We had the instrument inspected by a service engineer who reported that the unit powers up, but the IR source does not power up and the window is moisture damaged. The beam splitter looks fine and the laser powers up.


There is a PC with the unit it has Spectrum Software program version 5.3. on it.


The unit also comes with the following:


1x Perkin Elmer Part


1x Thomas Pump

Model: 107CCD14TFFL-621

The unit powers up


1x RS-232 DE-19 Cable


3x RLT-GNP1000-02


It is sold for spares/repairs.

Image of Pike Technologies MIRacle ATR reflection Accessory Kit Lab

£ 1,000.00 (ex. VAT) 1 in stock

Pike Technologies MIRacle ATR reflection Accessory Kit Lab

ITEM-44388

Pike Technologies MIRacle ATR reflection Accessory Kit Lab


This item was removed from a university where it was surplus to requirement.


All items included are in good cosmetic condition, however we are unable to test them at our facility.


The components included are as follows:


  • Pike MIRacle
  • ATR
  • Allen key set
  • Replacement tubing

The items come in a protective case.

Image of Varian 660-IR FT-IR Spectrometer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,000.00 (ex. VAT) 1 in stock

Varian 660-IR FT-IR Spectrometer Lab Spares/Repairs

ITEM-41289

Varian 660-IR FT-IR Spectrometer


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, it has been seen by an engineer with a summary of the report stated below.


The beam splitters showing signs of moisture damage, and the unit has software recognition issues.

As a result, it is listed as Spares/Repair.

Image of Varian 640-IR FT-IR Spectrometer Lab

£ POA 1 in stock

Varian 640-IR FT-IR Spectrometer Lab

ITEM-41919

This item is new in stock. Please enquire for further details.

Items 1 to 9 of 9

Filters

Price (£)

to

Condition

Brand