Items 1 to 20 of 27

Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 9,010.00 (ex. VAT) 1 in stock

New Brunswick Innova 4430 Refrigerated Incubator Double Stack Lab

ITEM-25989

This New Brunswick Innova 4430 Refrigerated Incubator Double Stack was removed from a university lab where it was surplus to requirements.


Both units have been recertified and fully tested by a service engineer. It has had band new bearings and drive belts fitted. They have both been deep cleaned, inside and out.


They have both been tested up to 400rpm and run smoothly.


They are both in reasonably good cosmetic condition but have marks from age and usage.

Image of item

£ 7,650.00 (ex. VAT) 1 in stock

New Brunswick Innova 4400 Floor Standing Shaking Incubator Double Stack Lab

ITEM-25341

New Brunswick Innova 4400 Floor Standing Shaking Incubator Double Stack


These were removed from a university lab where they were surplus to requirements.


They have been fully tested to incubate and shake by a service engineer. They are in full working order.


Inside dimensions - D57 W93 H44cm

Platform - 46 x 77cm


They come with brackets for stacking, but there are only 3 feet and one of them is broken.




Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 6,815.00 (ex. VAT) 1 in stock

New Brunswick Innova 44 Incubator/Environmental Shaker M1282-0002 Lab

ITEM-16782

This New Brunswick Innova 44 Incubator/Environmental Shaker was removed from a university lab where it was surplus to requirements.


The unit has been tested and rebuilt by and service engineer.


It has had the following replacement parts;

Screen.

Control knob.

New mount bolt kit.

The Shaker plate assembly was stripped and rebuilt.

2 x Shaker plate pivot pins.

1 x Shaker plate top bearing.

3 x Shaker bearing.

All brand new rubber isolation washers.

All wires in the motor were cut, re-soldered & heatshrunk etc.


The unit has been tested at 400rpm (max) and the incubator is in full working order.


Included with it are;


Multiple Sized Shaker Flask Clip Kits.

Multiple Sized Screws and Washers - One bottle labelled "Green Shakers", Another labelled " Screws for flask holder".

8 x 25ml Flask Clips.

3 x Plastic bases - 1 x 10cm in diameter, 2 x 7.4cm in diameter.

3 x Alan Keys - all different sizes.

3 x Xcelite P10 5/16 Alan key drivers.

A box of Springs.

A box of small (Same size of 25ml) flask clips.


Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 6,340.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 44 Incubator/Shaker w/ Accessories

ITEM-24742

This New Brunswick Scientific Innova 44 was removed from a university lab where it was surplus to requirements.


The unit has been seen by a service engineer who has replaced the control pot, bearings, bearing post and shaker plate. It is in full working order.


It is in very good cosmetic condition with only minor marks from use.


M1282-0002

Image of item

£ 6,000.00 (ex. VAT) 1 in stock

Kuhner Floor Standing Laboratory Incubator Shaker Model - ISF-1-W Lab

ITEM-24435

This Kuhner Floor Standing Laboratory Incubator Shaker  Model - ISF-1-W was removed from a university lab where it was surplus to requirements.



Internal Dims:

D64cm x W94cm x H50cm

(Height was measured from the shaker mech to the top of the chamber).


The unit powers on with the incubator and shaker appearing to be in working order There are scratch marks on the LHS of the unit and on the bottom shelf from general use.  There are surface stains and marks inside the unit and outside of the unit, from general use.  There is a large crack in the inspection perspex on top of the unit that travels right across the length of it. The Perspex is double-glazed and has only cracked the outside layer.


Set temp at 37ºC our thermometer read 38.8ºC

Set temp at 40ºC our thermometer read 40.9ºC

Set temp at 80ºC our thermometer read 76.4ºC

The temperature never reached 80ºC, the unit settled on our thermometer's temperature reading, as above.


Shaking test:

• 20 min-1 (the unit ran smoothly)

• 180 min-1 (the unit ran smoothly)

•300 min-1 (the unit ran smoothly)


Included with it are;


30x small clamps with spring retainers.

Dims: L9cm x W9cm x H6cm


9x large clamps with spring retainers.

Dims: L16cm x W16cm x H9cm




Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 4,870.00 (ex. VAT) 1 in stock

Thermo Scientific MAXQ 6000 Incubator Shaker Model 4352 Lab

ITEM-30210

This Thermo Scientific MAXQ 6000 Incubator Shaker Model 4352 was removed form a university lab where it was surplus to requirements.


This unit has been recertified by a service engineer. They fitted a brand new drive belt and door catches. It has been tested and is in full working order. The Thermo temp gauge was for testing purposes only and is not included.


It is in excellent cosmetic condition with only minor marks from use.

Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 4,315.00 (ex. VAT) 1 in stock

Thermo Scientific MAXQ 4000 Incubator Shaker Lab

ITEM-30192

This Thermo Scientific MAXQ 4000 Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit powers up and has been inspected and recertified by a service engineer. It has had the following new parts fitted. It is in good working order.


2 x Gas struts.

3 x Shaker plate bearings.

1 x Drive belt.


It has also had a replacement shaker plate drive section fitted.


It is in excellent cosmetic condition with only minor marks from use.


Image of item

£ 3,560.00 (ex. VAT) 1 in stock

Barnstead Lab-Line MaxQ 4000 Incubator Shaker Model - SHKE4000-1CE

ITEM-28143

This Barnstead Lab-Line MaxQ 4000 Incubator Shaker  Model - SHKE4000-1CE was removed from a university lab where it was surplus to requirements.


The unit powers up and is working. It has been assessed by an engineer who replaced the lid struts and fitted a new drive belt.


The only issue is the main power button on the front of the unit doesn't appear to work. This does not affect the operation of the unit at all. It just needs to be switched on and off at the main supply.


The incubator function was tested with a digital thermometer (not included).


The temperature was first set to 37°c. when reached temp the thermometer read 37.6°c.

The temperature was then set to its max temp of 60°c, when it reached temp, the thermometer read 58.8˚c.



Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 3,520.00 (ex. VAT) 1 in stock

New Brunswick Innova 4400 Floor Standing Shaking Incubator Lab

ITEM-25606

New Brunswick Innova 4400 & Innova Shaking Incubator.


This was removed from a university lab where it was surplus to requirements.


The unit has been assessed by a service engineer and has had the following replacement parts fitted.


Motor.

Temperature sensor bracket.

Door mechanism.

Gas struts.

Base.

Various panels.


It has been tested at various speeds and is shaking well.


It has been temperature tested at:

37ºC - It reached this temp fine. We calibrated it with our SmartVue Thermometer (not included).

80ºC - It reached 73ºC and it was at this temperature for quite a while.


The unit is in good cosmetic condition but has marks from use.


The manual is supplied.




Image of item

£ 3,290.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 4330 Refrigerated Shaking Incubator

ITEM-29942

This New Brunswick Scientific Innova 4330 Refrigerated Shaking Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and the incubator and shaker have both been tested (digital thermometer not included). It is in full working order.


The unit is in good cosmetic condition but the lid seal is starting to detach and likely needs replacing.


Internal Dimensions - 87 x 56 x 34 cm (up to the top where the lid would seal)

Image of item

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 3,155.00 (ex. VAT) 1 in stock

Infors AI 70 Minitron Laboratory Shaking Incubator Lab

ITEM-26007

This was removed from a university lab where it was surplus to requirements.


The unit has been tested by a service engineer, but will still require calibration upon installation.


The unit is in reasonable used cosmetic condition. A brand new OEM gas strut for the door has been fitted. The shaker works as it should and has been tested up the max of 400rpm.


The unit has been temperature tested at:


37ºC our thermometer showed 34.2ºC.

To get it to run at 37ºC the unit needs to be set to 40ºC


65ºC (Max) our thermometer showed 63.2ºC.


The unit requires calibration.


Internal Dimensions:


41cm L x 48cm D x 40cm H.


Length & Depth are the shaker tray dimensions.


Image of item

£ 3,030.00 (ex. VAT) 1 in stock

New Brunswick Innova 4300 Incubator Shaker Mfg no. M1193-0100 Lab

ITEM-31245

This New Brunswick Innova 4300 Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). The shaking plate has also been tested. The system is in full working order.


It is in reasonable cosmetic condition with marks from use.


Internal dimensions - L88 W56 D34cm

Image of item

£ 3,000.00 (ex. VAT) 1 in stock

Medline Scientific Jeio Tech Lab Companion Incubator Shaker IST-3075R

ITEM-31890

This Medline Scientific Jeio Tech Lab Companion Incubator Shaker IST-3075R was removed from a university lab where it was surplus to requirements.


The unit powers on and is in good working order. The shaker runs up to 500rpm and the incubation works.


It is in good cosmetic condition with minor marks from use.


Internal dimensions - L41 W40 H32

Shaker Platform - 35 x 35cm

2 x 1000ml Flask Clamps

Tube Stand holds 10 x 50ml Tubes




Image of item

£ 2,440.00 (ex. VAT) 1 in stock

Barnstead International Max Q 4000 Laboratory Incubator Shaker SHKA4000-8CE Lab

ITEM-25240

This Barnstead International Max Q 4000 Laboratory Incubator Shaker SHKA4000-8CE was removed from a university lab where it was surplus to requirements.


This unit has been recertified and is in full working order. It has had a new drive belt and a pair of new lid struts fitted.


It has been fully temperature tested.


It is in good cosmetic condition with some marks from use.



Image of item

£ 1,770.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 4000 Benchtop Incubator Shaker Lab

ITEM-30218

This New Brunswick Scientific Innova 4000 Benchtop Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit powers up and runs up to 500rpm. It was tested with a digital thermometer (not included).


The temperature was first set to 37°c, when reached, the thermometer read 42.8˚c

The temperature was then set to 60˚c (max) when reached, the thermometer read 64.4˚c


It is in reasonable cosmetic condition with some marks from use.


Internal Dimensions:

D48.3 W50.2 H33.6cm



Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,765.00 (ex. VAT) 1 in stock

Thermo Scientific Max Q 4000 Shaking Incubator Lab Spares/Repairs

ITEM-30287

This Thermo Scientific Max Q 4000 Shaking Incubator was removed from a university lab where it was surplus to requirements.


The unit would not power up in testing. We swapped the boards out but still could get it to power. There were loose parts inside, so we assume it has been stripped. It has a very worn drive section.


It's in reasonable cosmetic condition with some marks from use.


It is sold for spares/repairs.

Image of item

£ 1,750.00 (ex. VAT) 1 in stock

New Brunswick Scientific Classic C24 Incubator Shaker Lab

ITEM-31977

This New Brunswick Scientific Classic C24 Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit is in good working order and has been tested with a digital thermometer (not included). It runs well up to 400rpm.


It is in reasonable cosmetic condition but has some fairly heavy usage marks.


Internal dimensions - L54 W52 H36cm

Shaker Platform - 45.5 x 45.5cm


Tube stand inside holds 20 x 50ml tubes


Image of item

£ 1,385.00 (ex. VAT) 1 in stock

Gallenkamp IOI400.XX2.C Floor Standing Shaking Incubator Lab

ITEM-12238

This Gallenkamp IOI400.XX2.C Refrigerated Shaking Incubator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested.


It was tested using a Thermo Smart-Vue gauge (not included).

The gauge showed 37.4ºC when the unit was set to 37ºC.

The gauge showed 59.8ºC when the unit was set to 60ºC (Max).


The max rpm is 400, which the unit runs fine at. The first digit of the rpm screen does have issues, but the rpm can still be set ok.


It is not a refrigerated unit.


Inner dimensions: 85.5cm L x 35cm W.

Shaker plate dimensions: 69cm L x 49cm W.



Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 1,000.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair

ITEM-31913

This New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit powers up and the shaker and the incubation functions work, but it has a compressor fault causing the refrigeration to not work.


It is in good cosmetic condition with marks from use.


Internal dimensions - L60 W53 H62cm

1 Shelf - 51 x 51cm


Image of item

£ 935.00 (ex. VAT) 1 in stock

Gallenkamp Orbital Laboratory Shaking Incubator Cat no. IOX400.XX1.C Lab

ITEM-25297

This Gallenkamp Orbital Laboratory Shaking Incubator  Cat no. IOX400.XX1.C was removed from a university lab where it was surplus to requirements.


The item powers on and the shaker runs up to 400rpm. It has been tested with a digital thermometer (not included).


The temperature was first set to 37°c which it reached quickly. The temperature was then set to its maximum of 70°c, after an hour or so the thermometer was reading 65°C.


The item is in a reasonable, used cosmetic condition.


Unit dimensions - L103 x W68 x H74cm

Inside dimensions - L76 x W55 x D43cm


Platform size - 70 x 50cm

Items 1 to 20 of 27

Filters

Price (£)

to

Condition

Brand

Category filters

Type

CO2 Sensor Type

Heating Method

With Hot Air Sterilisation

Humidifier

Refrigeration

Minimum Temperature (°C)

to

Maximum Temperature (°C)

to

With UV Lamp

Physical Specifications

Configuration

Interior Volume (l)

to