Items 1 to 20 of 70

Image of item

£ 9,545.00 (ex. VAT) 1 in stock

Huber Unistat 380W Refrigerated Heating Circulator Lab

ITEM-24477

This Huber Unistat 380W Refrigerated Heating Circulator was removed from a university lab where it was surplus to requirements.


The unit powers on and is in good cosmetic condition. Both digital displays are working and display clearly. All buttons appear to be responsive to the unit.


BE: Version 3.7

Image of item

£ 5,075.00 (ex. VAT) 1 in stock

Grant RC 1400G Recirculating Chiller Lab

ITEM-31257

This Grant RC 1400G Recirculating Chiller was removed from a university lab where it was surplus to requirements.


The unit powers up and is in reasonable cosmetic condition with some marks from use.


We tested it at multiple temperatures and it is in working order.



Image of item

£ 4,155.00 (ex. VAT) 1 in stock

Julabo FP50 Refrigerated/Heating Circulator with MV/K-S Control Unit Lab

ITEM-18880

Julabo FP50 Refrigerated/Heating Circulator with MV/K-S Control Unit


This was removed from a university lab where it was surplus to requirements.


It consists of;

Control unit - Model - MV/K-S GB

Chiller Unit - Model FP50 GB


The unit powers up and has been tested with a digital thermometer.


You can set the chiller to -50 but it didn't drop lower than -20 after running all day. Our thermometer read -17. This was likely due to the concentration of antifreeze we used.


It was set to 37 which it reached and held at quickly. We then set it to the max of 100 which it also reached and held at.


It is in reasonably good cosmetic condition with some marks and staining from use.

Image of item

£ 4,000.00 (ex. VAT) 1 in stock

Perkin Elmer Intracooler N5374099 DSC Cooling System Lab

ITEM-36792

This Perkin Elmer Intracooler N5374099 DSC Cooling System was removed from a university lab where it was surplus to requirements.


The unit powers up and is in good working order.


It is in good cosmetic condition with marks from use.



Image of item

£ 3,500.00 (ex. VAT) 1 in stock

Covaris S2 Focused Ultrasonicator with Grant LTC1 Water Bath Lab

ITEM-30312

Covaris S2 Focused Ultrasonicator with Grant LTC1 Water Bath


This was removed from a university lab where it was surplus to requirements.


Included are;


1 x Covaris S2 Focused Ultrasonicator

Model S2

Ser No. 541

The unit powers on and is in good cosmetic condition. The motor can be heard almost immediately after powering on the unit. We were unable to test it further.



1x Grant LTC1

Model R2

The unit powers on and is in good cosmetic condition.

It has been tested with a digital thermometer (not included) and is in good working order.


Image of item

£ 3,215.00 (ex. VAT) 1 in stock

Thermo Scientific VersaCool Refrigerated Circulating Water Bath Lab

ITEM-24423

This Thermo Scientific VersaCool Refrigerated Circulating Water Bath was removed from a university lab where it was surplus to requirements.


The unit powers up and is in very good cosmetic condition. It was tested with a digital thermometer (not included).


Heating:-

Tested with water, the temperature was set to 37˚c, the temperature quickly went up to 38˚c while the thermometer read 37˚c. It was then tested up to the maximum temperature (for water) of 90˚c which it reached after around 10 minutes, thermometer also read 90˚c. It can go higher but we didn't want it to boil. It is rated for 150˚C.


Cooling:-

Tested with Antifreeze, the temperature was set to -20˚c, it dropped quite quickly to -8˚c but seemed to stop cooling from there, only dropping a further 0.3˚c over the next few hours. The thermometer read -9.6˚c. This is likely due to the concentration of antifreeze used.


Image of item

£ 2,445.00 (ex. VAT) 1 in stock

Betta-Tech CU800 Heater/Chiller Circulator Unit Lab

ITEM-28179

This Betta-Tech CU800 Heater/Chiller Circulator Unit was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included) and appears to be operational within the parameters of -5˚C and 25˚C.


It is in reasonably good cosmetic condition but has some marks and scuffs from use.

Image of item

£ 2,000.00 (ex. VAT) 1 in stock

Julabo F 25-ED Refrigerated/Heating Circulator Water Bath Lab

ITEM-36254

Julabo F 25-ED Refrigerated/Heating Circulator Water Bath


This was removed from a university lab where it was surplus to requirements.


The unit powers up and was tested with a digital thermometer (not included).  It is in good working order.


It is in good cosmetic condition with marks from use.


1x Control Unit -

Model: ED (v.2)

S/N: 0293511


1x Chiller Unit -

Model: GB

S/N: 00294020


Image of item

£ 1,705.00 (ex. VAT) 1 in stock

Calipur Life Sciences TurboVap II Concentration Evaporator Water Bath

ITEM-24410

This was removed from a university lab where it was surplus to requirements.


The water bath module is in working order, but we have not tested the air inlet at our facility.


It is in good cosmetic condition with minor marks from use.


PN - 103193/1

Image of item

£ 1,700.00 (ex. VAT) 1 in stock

Calipur Life Sciences TurboVap II Evaporation Concentration Water Bath Lab

ITEM-24409

This was removed from a university lab where it was surplus to requirements.


The water bath module is in working order, but we have not tested the air inlet at our facility.


It is in good cosmetic condition with minor marks from use.


PN - 103193/1

Image of item

£ 1,690.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 3100 Shaking Water Bath Lab

ITEM-18844

This New Brunswick Scientific Innova 3100 Shaking Water Bath was removed from a university lab where it was surplus to requirements.


The unit has been inspected by a service engineer. The tested it and found it to be fully working. The shaker runs up to 400rpm and the water bath was tested at various temperatures up to 80˚C.


It is in good cosmetic condition but there is a crack in the lid.


Dimensions:-

Shaker Plate: 42cm L x 30.5cm W.

Inner Bath dimensions: 45cm L x 35.5cm W x 15.5cm H.

Image of item

£ 1,690.00 (ex. VAT) 1 in stock

Calipur Life Sciences TurboVap II Conctration/Evaporation Water Bath Lab

ITEM-24408

This was removed from a university lab where it was surplus to requirements.


The water bath module is in working order, but we have not tested the air inlet at our facility.


It is in good cosmetic condition with minor marks from use.


PN - 103193/1

Image of item

£ 1,630.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 3100 Shaking Water Bath Lab

ITEM-24776

This New Brunswick Scientific Innova 3100 Shaking Water Bath was removed from a university lab where it was surplus to requirements.


The unit has been fully tested by a service engineer. It is in full working order.


It is in reasonably good cosmetic condition with some marks from use.


Interior dimensions:

L45cm x W35cm x D15cm



Image of item

£ 1,630.00 (ex. VAT) 1 in stock

Fisher Scientific Circulating Bath Model - BC20 ET100 Lab

ITEM-23321

This bath was removed from a university lab where it was surplus to requirements.


The unit has been fully tested and is in good working order. It both heats and chills well. The test probes in the photos are not included.


It is in good cosmetic condition with only minor marks from use.


Fisher Scientific Circulating Bath

Model - BC20

Type - 003-6612 1200400816006


Control

Model - ET100

Type - 003-6000 1200302532010


Image of item

£ 1,500.00 (ex. VAT) 1 in stock

PSL Rheotek TCB 8 Temperature Controlled Viscometer Bath Lab

ITEM-28204

PSL Rheotek TCB 8 Temperature Controlled Viscometer Bath


This was removed from a university lab where it was surplus to requirements.


The unit powers up and the heating is in good working order.


Inside tank dimensions - L59 W31 H37cm


It is in good cosmetic condition with some marks from use.

Image of item

£ 1,500.00 (ex. VAT) 1 in stock

Townson + Mercer Series IV Constant Temperature Viscometer Bath Lab

ITEM-28206

Townson + Mercer Series IV Constant Temperature Viscometer Bath


This was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer. It is in working order.


It is in good cosmetic condition with marks from use.



Image of item

£ 1,490.00 (ex. VAT) 1 in stock

PSL Rheotek TCB 8 Temperature Controlled Water Viscometer Bath Lab

ITEM-28205

PSL Rheotek TCB 8 Temperature Controlled Viscometer Bath


This was removed from a university lab where it was surplus to requirements.


The unit powers up and the heating is in good working order.


Inside tank dimensions - L59 W31 H37cm


It is in good cosmetic condition with some marks from use.



Image of item

£ 1,440.00 (ex. VAT) 1 in stock

Thermo Fisher Scientific NESLAB RTE 7 Circulating Water Bath Refrigerated Lab

ITEM-25800

This Thermo Fisher Scientific NESLAB RTE 7 Circulating Water Bath was removed from a university lab where it was surplus to requirements.


The item is in good cosmetic condition with marks from use.


The item powered on without issue and was tested with a digital thermometer (not included). We tested the chiller with 50/50 antifreeze.


When set to -25˚C the display showed -10.6˚C and the thermometer measured -9.0˚C. This is likely due to not using a high enough concentration of antifreeze.

When set to 4˚C the display showed 4˚C and the thermometer measured 4.0˚C.

When set to 37˚C the display showed 37˚C and the thermometer measured 36.6˚C

When set to 100˚C the display showed 100.5˚C and the thermometer measured 100.3˚C.


The max operating temperature is 150˚C but we were unable to operate it to that temperature.




Image of item

£ 1,430.00 (ex. VAT) 1 in stock

KODIAK Lytron Recirculating Chiller Model RC022H03FB2M066 w/ Turbine Pump Lab

ITEM-20061

This KODIAK Lytron Recirculating Chiller Model RC022H03FB2M066 was removed from a university lab where it was surplus to requirements.


The unit has been fully tested and it ran at;


5ºC, 15ºC and 35ºC


The unit runs great. The filter does leak around the rim and we suspect the main seal needs replacing.


From the spec sheet:

Reservoir Capacity: 7.6L.

Temperature Range: 5ºC - 35ºC.

Compressor Size: 3/4 HP.


It is in good cosmetic condition but is missing the front grill.





Image of item

£ 1,405.00 (ex. VAT) 1 in stock

Lauda RE210 Refrigerated Water Bath Type RE210/B Lab

ITEM-30342

This Lauda RE210 Refrigerated Water Bath was removed from a university lab where it was surplus to requirements.


The unit powers up and was tested and calibrated with our digital thermometer(not included). It is in full working order but may need calibrating to your thermometers.


It is in good cosmetic condition with minor marks from use.





Items 1 to 20 of 70

Filters

Price (£)

to

Condition