Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab
Item Code: ITEM-44681
Condition: Used
£ 15,000.00 exc. VAT (£ 18,000.00 inc. VAT)
If you are interested in this item or would like to place an order, please get in touch with us at , or by phone on +44 29 2086 4661.
Description
Beckman Coulter MoFlo XDP Cell Sorter Laser Cytomation System + Optics Table Lab
This system was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, the working condition of each unit that we were able to test is listed below.
Parts of the system:-
Optics Table - MoFlo Optical Bench
SN - 2086
Dimensions - L153 W122 H80.5cm
Measurement - Imperial
Parts fitted on table:-
Pressure Console Unit
SN - 2086
Coherent Sapphire
Model - Sapphire LP USB CDRH Driver Unit w/display
PN - 1189089
SN - LDP.1189089.C02070
- Powers on
Coherrent Sapphire 488-200 CW CDRH
PN - 1137970
SN - LDP.1137970.521683
Heatsink Sapphire LP RoHS compl
- NOT TESTED
Coherrent Cube
PN - 1170509
SN - C20010803
- NOT TESTED
Coherrent Cube
PN - 1193821/AA
SN - C14070901
- NOT TESTED
Hamamatsu Parts:-
H957-27 (No.T0050)
H957-18 (No.K0149)
H957-27 (No.T3721)
H957-25 (No.S0319)
H957-25 (No.S0360)
H957-25 (No.S0359)
H957-25 (No.S0322)
H957-25 (No.S0324)
H957-27 (No.T0051)
H957-27 (No.T0054)
H957-25 (No.S0358)
H957-25 (No.S0321)
H957-25 (No.S0323)
Smart Sampler
2 x Preamplifier Units
SN - 2086
DTx Data Display 19" LCD w/Touchscreen
BCI PN - B44222
DTx PN - 90819
SN - BCM0514F37003
- Powers on via Miami MoFlo XDP Controller
Under table units:-
DTx BCI Miami MoFlo XDP Controller
DTx PN - 90692
BCI PN - B20566
DTx SN - BCM0915F44602
- Powers on - When powered up, an error message reads 'OdinInstControl::connectMachine failed: AttachedInstrument::GetInstance:Repository had communication error!'
Gast Vacuum Pump
DOA-P501-BN
- Powers on
Intellipower UPS
Model - IQ200V-C-DiAC-Isol-PFC
SN - 2FKVDIFC5B15110524
- Powers on
Beckman Coulter Aerosol Evacuation System Buffalo Filter w/ Pedal
Model - 200-0179
SN - 502135
Has ViroSafe Filter fitted (PN-200-8166)
- Powers on.
3 x 316L UM Alloy Products Corp Pressure Vessels:-
SN - S533735-1-005 (2014)
SN - S514233-1-011 (2010)
SN - S507165-1-008 (2008)
Other units:-
Thermo Scientific Recirculating Water Bath
Control - C10 Type - 003-5009/SN - 1 08004133017
Bath - K20 Type - 002-4276/SN - 08004052 003
- Powers on
Testing:-
37˚c - Thermometer read 37.6˚c
100˚c - Thermometer read 100.0˚c
-20˚c - Thermometer didn't read lower than -13.5˚c
Jun Air Compressor
Type - OF302-25MQ
SN - 0119802962
- Powers on with compressor running
Hours - 00898.3
Other spare bits:-
1 x Black Case of various filters
1 x Black Case containing 3 x Merlin Gerin fuses, Methanol & Acetone
2 x Sets of Spare Shaped Charged Plates (one pair boxed)
1 x Box of Filters
1 x Box of mixed size O-rings
Red Ethernet cable
5 x IEC Extension cables
Delivery
Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.
Additional terms and conditions
If the Cytometer purchased has a Class 3 or above laser fitted, a disclaimer will need to be signed confirming understanding that the device is a class 3 or above laser device which can pose significant risks to skin, eyes, general health and can even act as a fire hazard.
The buyer will need to accept and indemnify all liability and responsibility for the Laser Device and parts thereof from the seller for any future use.
Return policy
Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.
NOTE: No cables, remotes, accessories, power supplies, consumables or any other items are included unless shown in the item photos or detailed above.