Flow Cytometers
Items 1 to 22 of 22

£ 21,000.00 (ex. VAT) 1 in stock
Beckman Coulter MoFlo Astrios EQS Flow Cytometer System & Sterilgard Cabinet Lab
ITEM-31566
MoFlo Astrios EQS Cell Sorter in BSL Hood.
All units are in good used cosmetic condition.
The system powers up as it should.
We were informed by the lab that the Red laser is faulty and requires replacement.
The unit has the following lasers installed:
1 X 640NM - 106MW.
1 X 561NM - 202MW.
1 x 488NM - 200MW.
1 X 405NM - 55MW.
The writing is quite faint on the MW output, so the above figures might not be 100% correct.
The complete system consists of:
1 x Baker Company SG503HE-BC-INT SterilGARD hood.
Manufactured 09/30/2013.
1 x Moflo Astrios EQS Main Unit.
The unit has various marks and scratches from general use.
Powers up fine.
1 x Moflo Astrios Lower/Laser/Computer Section.
The laser & computer system powers up fine.
1 x Thermo/Haake SC100/A28 re-circulator/chiller.
Powers up fine.
1 x Intellipower UPS.
Powers up fine.
1 x Jun-Air OF302 Silent Air Compressor.
It was noted by the lab that this is quite loud. We powered it on and it sounds normal for one of these units.
Also includes various spares and accessories shown in pictures.
3 x '100' spare nozzle tips
8 x '70' spare nozzle tips.

£ 10,470.00 (ex. VAT) 1 in stock
BD Becton Dickinson LSR II Flow Cytometer Lab
ITEM-36938
BD Becton Dickinson LSR II Flow Cytometer
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further without a PC and software. The lab informed us when it was last used a few years ago, it was still working.
The unit is in overall good cosmetic condition with marks from use. There is a crack in the front and the right-hand cover and the left-hand door doesn't close fully.
2 x One AC
Model - CBS2120
PN - 011-526
SN - 0129 - 6308/0129-6304
Becton Dickinson Closed Waste Container
Alloy Products Corp 316L Waste Container (Lid doesn't fit)
SN - 115443-007
Table not included.

£ 10,000.00 (ex. VAT) 1 in stock
Becton Dickinson BD LSR II Flow Cytometer w/FACSFlow Supply System Lab
ITEM-37226
BD LSR II Flow Cytometer with FACSFlow Supply System
This system was removed from a university lab where it was surplus to requirements.
The flow cytometer is in reasonable used cosmetic condition but was not powered on due to its class 3b laser component.
The previous client has stated this system was functional prior to removal from the lab.
Additional components include:
- FACSFlow Supply System
- Ref: 349277
- SN: N2791
- Powers on
- OneAC UPS
- Model: PCM1500U
- SN: 0921-6555
- Powers on
- BD Closed Waste Container Unit
Includes two cables for connecting the UPS to the flow cytometer.
Model: LSR II
Cat No.: 648088
SN: H08800002

£ 10,000.00 (ex. VAT) 1 in stock
BD FACSCanto II Flow Cytometer with Fluidics Cart, PC, Software & Accessories
ITEM-42914
BD FACSCanto II Flow Cytometer with Fluidics Cart, PC, Software & Accessories
This system was removed from a university laboratory where it was surplus to requirements.
The system was kept under a full service contract and was in full working condition until it was decommissioned six months ago. Due to the presence of a Class III laser, it has not been tested due to safety limitations at our facility.
In very good cosmetic condition, with all key accessories and software included.
It is 3-laser (9 colour)
Includes:
- BD FACSCanto II Flow Cytometer
- Model: BD FACSCanto II
- Serial No.: V96101193
- BD FACSCanto II Fluidics Cart
- Model: BD FACSCanto II Fluidics Cart
- Serial No.: N/A
- HP Z230 PC (Administrator password: BDIS#1)
- NEC Multisync LCD2490WUXI Monitor
- Keyboard and Mouse
- Waste Container
- BD FACSCanto II Instructions For Use - Manual
- Software USB
- 2 x General Purpose 120 to 240 VAC Cables
- 3 x Pilot Duty 20 VA 120 to 240 VAC Cables
- HP Color LaserJet CP1510 Series Printer
Software Installed on PC:
- BD FACSCanto Clinical Software V2.4
- BD FACSCanto II System Documentation V2.4
- BD FACSDiva Software V6.1.3

£ 10,000.00 (ex. VAT) 1 in stock
BD FACSCanto II Flow Cytometer System w/ Fluidics Carts, PC & Software Lab
ITEM-37241
BD FACSCanto II Flow Cytometer System with PC, Software, and Accessories
This system was removed from a university laboratory where it was surplus to requirements.
The system includes a BD FACSCanto II Flow Cytometer, Fluidics Cart, and a complete PC setup with software and manuals. Due to the presence of a Class 3 laser, the flow cytometer could not be powered on. The fluidics cart powers on and is fully equipped.
This is a 2 laser 6 colour (4-2) unit.
Components and Condition:
BD FACSCanto II Flow Cytometer
- Catalog No.: 338960
- Serial No.: V96100924
- Condition: Unable to power on due to Class 3 laser.
BD FACSCanto Fluidics Cart
- Serial No.: N/A
- Powers on.
- Included Bottles:
- Waste Bottle
- BD FACSRinse (REF 340346)
- 2 x BD FACSClean (REF 340345)
- BD FACS Shutdown Solution (REF 334224)
PC & Accessories:
- HP Z240 PC: Powers on, software installed. - Password for PC available on request.
- NEC 24" Monitor: Powers on.
- HP Mouse and Keyboard.
- Cables: 2 x Ethernet cables, 1 x Comms cable.
- FACS Diva software - Password not required.
Included Software and Manuals:
- BD FACSCanto II System Software
- Application Handbook (2nd Edition)
- BD High Throughput Sampler Users Guide
- Getting Started with BD FACSDiva Software
- BD Cytometer Set Up & Tracking Application Guide
- BD FACSCanto II Training Manual
- BD FACSCanto II Instructions for Use
- BD HTS for FACSCanto II FSE Installation Instructions
- Folders containing duplicate manuals, PC CDs, and service records.
- Toolbox with spare waste bottle lids and other small plastic fittings.

£ 7,325.00 (ex. VAT) 1 in stock
BioMerieux Chemunex Chemscan RDI Advanced Flow Cytometer Lab
ITEM-35297
BioMerieux Chemunex Chemscan RDI Advanced Flow Cytometer
This was removed from a university lab where it was surplus to requirements.
The system powers up and is in good cosmetic condition with minor marks from use.
There is a joystick and a keypad supplied.
There is no PC or software included.

£ 4,000.00 (ex. VAT) 1 in stock
DakoCytomation CyAn ADP Flow Cytometer with Fluids cart & PC w/ Software Lab
ITEM-47164
DakoCytomation CyAn ADP Flow Cytometer with Fluids Cart & PC
This system was removed from a university laboratory where it was surplus to requirements.
The main unit has not been powered on due to safety limitations at our facility with powering on Class III lasers.
However, the accompanying PC, fluids cart, and all listed peripherals power on without issue. The system remains in good cosmetic condition.
The previous owner has stated it was in working order prior to decommissioning.
Includes:
- DakoCytomation CyAn ADP Flow Cytometer
- Fluids cart/sheath management system
- PC w/ Summit V4 Software
- Samsung monitor
- Keyboard
- Mouse
- 1x Powervar ABCE800-22 Power Supply Unit

£ 3,500.00 (ex. VAT) 1 in stock
Becton Dickinson BD LSRFortessa Cell Analysis System with Accessories Lab
ITEM-30341
This Becton Dickinson BD LSRFortessa was removed from a university lab where it was surplus to requirements.
The lab informed us it was in full working order prior to removal.
Included are;
1x BD LSRFortessa Model No 649225B1
The unit powers on and is in good cosmetic condition. The fans are working and air can be felt blowing away from the unit.
1x ONEAC Power supply:
Model PCM1500U-CPBB
The unit powers the BD LSRFortessa unit. It is in good cosmetic condition. There are some light tape marks from general use.
1x BD High throughput Sampler:
Cat No. 647701
The unit powers on and is in good cosmetic condition.
1x BD FACSflow Supply System:
Ref, 349227
The unit powers on and is in good cosmetic condition.
1x Nalgene Bottle:
Volume, 2L
The unit is in good cosmetic condition.
1x BD Closed Waste Container:
The unit is in good cosmetic condition.

£ 1,350.00 (ex. VAT) 1 in stock
Baxter OptiPress II Automated Blood Component Extractor
ITEM-46126
Baxter OptiPress II Automated Blood Component Extractor
This item was removed from a university laboratory where it was surplus to requirements.
The unit powers on and begins initial operation, but is unable to proceed beyond the first few steps without a compatible blood bag.
No further functional testing has been performed. The system is in fair cosmetic condition with signs of use.
Includes:
- Physical copy of manual
Model: OptiPress II

£ 1,150.00 (ex. VAT) 1 in stock
Beckton Dickinson FACSCalibur System w/ Workstation - ModFit L Software Lab
ITEM-47340
Beckton Dickinson FACSCalibur System with ModFit LT Software
This system was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition.
Due to TESTING limitations with testing class 3+ lasers, we were unable to power the unit on at our facility. However, the previous owner has stated that the system was in working order prior to removal.
Includes:
System Components:
- BD Transformer (SN: TE 3086)
Computer & Accessories:
- Apple Power Mac G4 (Model: M8570, SN: CK405HLJQEC) – Powers on with software installed
- Monitor (Model: CPD-GF250T, SN: 8015056) – Powers on
- Apple Keyboard and Mouse
Software & Documentation:
- ModFit LT Flow Cytometry Modelling Software Version 3.0
- BD Biosciences Instrument User’s Guide
- 2 x BD Biosciences Software User’s Guides
- FACSCalibur Training Manual
Additional Accessories:
- Cell Concentrator Utilities Kit
- Bottle with Filter and Stand

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
BD FACSCanto II Flow Cytometer with Fluidics Cart - Spares/Repair
ITEM-47335
BD FACSCanto II Flow Cytometer with Fluidics Cart - Spares/Repair
This system was removed from a facility where it was surplus to requirement.
This system is not currently in full working order. While several core components function as expected, including pressure build-up to 60 psi within 90 seconds, verified fluidics startup/shutdown, and laser outputs within specification.
There are critical issues affecting both the instrument and HTS module that require attention. Due to these issues, it is listed as Spares/Repair.
Key Operational Issues:
- The instrument's waste level sensor is blocked, causing a constant “waste full” reading. A spare sensor was temporarily used to complete fluidics startup.
- The sheath sensor is currently functional but shows visible damage (cracked cable) and is at risk of failure.
- The HTS module exhibits multiple faults:
- Two valves and a pump need replacing.
- The motor shows an over-voltage error on the X axis.
- The motor controller requires replacement.
- Tubing throughout the HTS is degraded and needs to be replaced.
A copy of the recent service report is available on request.

£ 1,000.00 (ex. VAT) 1 in stock
Beckton Dickson BD FACSCalibur Flow Cytometer w/ BD Transformer Lab
ITEM-42917
BD FACSCalibur Flow Cytometer with BD Transformer
This system was removed from a university laboratory where it was surplus to requirements.
The FACSCalibur unit powers on and is in good condition with some cosmetic wear.
The BD Transformer also powers on and is in good condition with minimal wear.
No further testing has been performed, due to limitation surrounding Class III Laser testing at our facility.
Includes:
- BD FACSCalibur Flow Cytometer (Model: FACSCalibur, Serial No.: E1494)
- BD Transformer (Serial No.: TE 3928)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Millipore Guava EasyCyte HT Flow Cytometer Lab Spares/Repairs
ITEM-40069
Millipore Guava EasyCyte HT Flow Cytometer
This was removed from a university lab where it was surplus to requirements.
The system is in good cosmetic condition and powers on, however during testing there were undiagnosed issues identified that prevented use.
Therefore, it is listed as Spares/Repair.

£ 1,000.00 (ex. VAT) 1 in stock
BD FACSCalibur Flow Cytometer System Lab
ITEM-23424
This was removed form a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in reasonable cosmetic condition but has rust and marks from use.

£ 1,000.00 (ex. VAT) 1 in stock
BD FACSCalibur Flow Cytometer & Transformer Lab
ITEM-46623
BD FACSCalibur Flow Cytometer & Transformer - No Software Lab
This item was removed from a university laboratory where it was surplus to requirements.
The item is in a reasonable, used cosmetic condition. The struts do not hold the lid up, and the front drawer does not stay closed.
Due to restrictions on operating lasers at our site, we are unable to test the item.
The previous owner stated that they were recently able to power the unit and confirm flow functionality.
Includes:
- 1 x BD FACSCalibur Flow Cytometer
- 1 x Transformer

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 610.00 (ex. VAT) 1 in stock
BD Biosciences Accuri C6 Flow Cytometer Lab - Spares / Repairs.
ITEM-19437
This BD Biosciences Accuri C6 Flow Cytometer was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further. The lab we removed it from had reported it as faulty, though we are unsure of what the fault is. It comes with a power supply but there is no lead for it.
It is in good cosmetic condition with marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
BD FACSCalibur Flow Cytometer + Transformer Lab
ITEM-45456
BD FACSCalibur Flow Cytometer Lab
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition but has not been in use for many years; therefore, it likely is not in working order.
Due to restrictions on operating lasers at our site, we are unable to test the item.
As we are unable to test the item and its likely non-functional status, it is listed as Spares/Repair.
The power supply is included.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckton Dickson BD FACSCalibur Flow Cytometer - Spares/Repair Lab
ITEM-42916
Beckton Dickson BD FACSCalibur Flow Cytometer – Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
The BD FACSCalibur main unit does not power on and is in good condition with some wear.
Therefore, it is listed as Spares/Repair.
Included:
- BD FACSCalibur Flow Cytometer (Model: FACSCalibur | Serial No.: E1865)
- BD Transformer – Powers on; in poor condition with some wear (Serial No.: TE 1413)
- Magma Express Box 1T – Powers on; in good condition with minimal wear (Model: EB1T | Serial No.: 5220-03285)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Millipore Guava EasyCyte 8HT Flow Cytometer Lab Spares/Repairs
ITEM-30464
This Millipore Guava EasyCyte 8HT Flow Cytometer was removed from a university lab where it was surplus to requirements.
The system powers up and is in good cosmetic condition with only minor marks from use.
The unit has been tested with samples but was showing readings of 200-300 when it should be showing readings of around 50000. We were unable to diagnose the exact fault.
The unit has a Dell Optiplex 7010 PC paired with it. The PC includes a keyboard, mouse, monitor, USB and VGA Cable. It has had a brand new copy of 32bit Windows 7 installed.
Guavasoft 3.1 has also been installed, which includes:
ViaCount.
InCyte (This requires an unlock code from Millipore to run).
easyCheck.
Guava Clean 3.1.
We have been able to open and close the sample tray. This proves that the system is fully connected.
It is sold for spares/repairs.

£ 300.00 (ex. VAT) 1 in stock
Beckman Coulter Epics XL.MCL Cell Counter Flow Cytometer 4 Colour Lab
ITEM-16944
This Beckman Coulter Epics XL.MCL Cell Counter was removed from a university lab where it was surplus to requirements.
The system powers up but has not been tested further.
It is in good cosmetic condition but has some marks from use.

£ POA 1 in stock
Baxter Nexell CytoMate Cell Washer R4R9860 Lab
ITEM-46127
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
BD FACSCalibur Flow Cytometer With PC and Software
ITEM-42835
This item is new in stock. Please enquire for further details.
Items 1 to 22 of 22