Eppendorf 5804 R Centrifuge w/ Eppendorf A-4-44 Rotor Spares/Repair Lab

Item Code: ITEM-43174

Condition: Spares or Repairs

Location: Scotland

NOTE - THIS IS A SPARES/REPAIRS ITEM
£ 450.00 exc. VAT (£ 540.00 inc. VAT)
1 in stock
If you are interested in this item or would like to place an order, please get in touch with us at , or by phone on +44 29 2086 4661.
Make us an offer / ask us a question
Description

Eppendorf 5804 R Centrifuge w/ Eppendorf A-4-44 Rotor Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition but does not power on, therefore, it is listed as Spares/Repair.


Accessories;


  • Rotor - Eppendorf A-4-44
  • 4 x Swing Buckets Eppendorf 07/07
  • 4 x Sample Inserts with 4 holes 1.5 cm Diameter

Item Details

Property Value Tested value
1. PAT Test
Electrical Supply N/A 1-Phase
Plug Included? (1-Phase) N/A Yes - Standard UK 3-Pin Mains Plug (BS 1363)
PAT Test Result N/A Fail
PAT Test Fail Reason N/A Other - Please Specify
PAT Test Fail Reason Specifics N/A Doesn't Power On
PAT Test Date N/A 23-10-2025
Voltage N/A 240V
6. Service Details
Last Service Date N/A 22/06/2025
7. Other Details
Year of Manufacture N/A 2007
Further Info
Total Run Time (Hrs/Cycles) N/A Unknown
Rotor Included N/A Yes
Rotor Model N/A A-4-44
Rotor Max RPM N/A 5000
Rotor Buckets Included N/A Yes
Rotor Bucket Model N/A 07/07
Physical Specifications
With Refrigeration Yes
Minimum Temperature (˚C) -9.0
Maximum Temperature (˚C) 40.0
Maximum Speed (RPM) 14000 0
Power Consumption Kw 1,65
Delivery

Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.

Additional terms and conditions

These items are for spares/repair only, may be defective/unsafe, and are not intended for use.

Refrigerators will be transported in a variety of methods, including palletised couriers or direct transport "point of use". It is possible the internal refrigerant may have shifted during transport.
Allowing the unit to remain upright for at least 24 hours lets the refrigerant settle properly, preventing potential damage to the cooling system. Please ensure you allow sufficient settling time after receiving your delivery. Please also ensure you place the unit in its desired place of use before powering on for the first time, this is to prevent further movement post-delivery.

We suggest the below time periods are reached before powering on:

Fridges: 8hrs
Pharmaceutical Fridges: 8hrs
Freezers (≤ -20°C): 24hrs
Low Temperature (≤ -40°C): 48hrs
Ultra Low Temperature (≤ -80°C): 48hrs

Return policy

Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.

NOTE: No cables, remotes, accessories, power supplies, external PCs, software media, hardkeys, consumables or any other items are included unless shown in the item photos or detailed above.