Eppendorf 5804 R Centrifuge w/ Eppendorf A-4-44 Rotor Spares/Repair Lab
Item Code: ITEM-43174
Condition: Spares or Repairs
Location: Scotland
NOTE - THIS IS A SPARES/REPAIRS ITEM
£ 450.00 exc. VAT (£ 540.00 inc. VAT)
If you are interested in this item or would like to place an order, please get in touch with us at , or by phone on +44 29 2086 4661.
Description
Eppendorf 5804 R Centrifuge w/ Eppendorf A-4-44 Rotor Spares/Repair Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on, therefore, it is listed as Spares/Repair.
Accessories;
- Rotor - Eppendorf A-4-44
- 4 x Swing Buckets Eppendorf 07/07
- 4 x Sample Inserts with 4 holes 1.5 cm Diameter
Item Details
| Property | Value | Tested value |
|---|---|---|
| 1. PAT Test | ||
| Electrical Supply | N/A | 1-Phase |
| Plug Included? (1-Phase) | N/A | Yes - Standard UK 3-Pin Mains Plug (BS 1363) |
| PAT Test Result | N/A | Fail |
| PAT Test Fail Reason | N/A | Other - Please Specify |
| PAT Test Fail Reason Specifics | N/A | Doesn't Power On |
| PAT Test Date | N/A | 23-10-2025 |
| Voltage | N/A | 240V |
| 6. Service Details | ||
| Last Service Date | N/A | 22/06/2025 |
| 7. Other Details | ||
| Year of Manufacture | N/A | 2007 |
| Further Info | ||
| Total Run Time (Hrs/Cycles) | N/A | Unknown |
| Rotor Included | N/A | Yes |
| Rotor Model | N/A | A-4-44 |
| Rotor Max RPM | N/A | 5000 |
| Rotor Buckets Included | N/A | Yes |
| Rotor Bucket Model | N/A | 07/07 |
| Physical Specifications | ||
| With Refrigeration | Yes | |
| Minimum Temperature (˚C) | -9.0 | |
| Maximum Temperature (˚C) | 40.0 | |
| Maximum Speed (RPM) | 14000 | 0 |
| Power Consumption Kw | 1,65 | |
Delivery
Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.
Additional terms and conditions
These items are for spares/repair only, may be defective/unsafe, and are not intended for use.
Refrigerators will be transported in a variety of methods, including palletised couriers or direct transport "point of use". It is possible the internal refrigerant may have shifted during transport.
Allowing the unit to remain upright for at least 24 hours lets the refrigerant settle properly, preventing potential damage to the cooling system. Please ensure you allow sufficient settling time after receiving your delivery. Please also ensure you place the unit in its desired place of use before powering on for the first time, this is to prevent further movement post-delivery.
We suggest the below time periods are reached before powering on:
Fridges: 8hrs
Pharmaceutical Fridges: 8hrs
Freezers (≤ -20°C): 24hrs
Low Temperature (≤ -40°C): 48hrs
Ultra Low Temperature (≤ -80°C): 48hrs
Return policy
Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.
NOTE: No cables, remotes, accessories, power supplies, external PCs, software media, hardkeys, consumables or any other items are included unless shown in the item photos or detailed above.