Liebherr Lovibond Thermostatic Cabinet / Incubator Spares/Repair Labs
Item Code: ITEM-50583
Condition: Spares or Repairs
Location: Scotland
NOTE - THIS IS A SPARES/REPAIRS ITEM
£ 200.00 exc. VAT (£ 240.00 inc. VAT)
If you are interested in this item or would like to place an order, please get in touch with us at , or by phone on +44 29 2086 4661.
Description
Liebherr Lovibond Thermostatic Cabinet / Incubator
This item was removed from a university laboratory where it was surplus to requirement.
It powers on and has been successfully temperature tested.
However, the bottom left corner of the cabinet is damaged at the hinge point, meaning the door remains secure when closed but can fall off its hinges if opened fully.
The unit contains five internal 2-pin European-style sockets, which could not be tested using a socket tester.
Due to the issue stated above with the door hinge, it is listed as Spares/Repair.
Item Details
| Property | Value | Tested value |
|---|---|---|
| Part / Catalogue Number | ET 2 42 82 25 | |
| Type | Floorstanding | |
| Heating Method | Air Jacket | |
| Refrigeration | Yes | |
| Refrigerant | R 134 a | |
| CO2 Sensor Type | No CO2 Sensor | |
| With Hot Air Sterilisation | No | |
| Humidifier | N/A | |
| With UV Lamp | No | No |
| 1. PAT Test | ||
| Electrical Supply | N/A | 1-Phase |
| Plug Included? (1-Phase) | N/A | Yes - Standard UK 3-Pin Mains Plug (BS 1363) |
| PAT Test Result | N/A | Pass |
| PAT Test Date | N/A | 11-12-2025 |
| Voltage | N/A | 240V |
| 3. Recertification Initial Checks | ||
| Overall Cosmetic Condition | N/A | Poor |
| 6. Safety Features | ||
| Emergency Stop Safety Check | N/A | N/A |
| 7. Service Details | ||
| Last Service Date | N/A | Unknown |
| 8. Other Details | ||
| Configuration | N/A | Single Unit |
| Physical Specifications | ||
| Minimum Temperature (ºC) | 2 | |
| Maximum Temperature | 40 | |
| Interior Volume (L) | 195 | |
Delivery
Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.
Additional terms and conditions
These items are for spares/repair only, may be defective/unsafe, and are not intended for use.
Incubators may be transported via a range of delivery methods, including palletised courier networks or direct delivery to the intended location of use. During transit, internal sensors, fans, or control systems may be affected by vibration or movement.
To ensure optimal performance and accurate environmental conditions, it is essential that all incubators are allowed to stabilise upon arrival and are professionally calibrated before first use. Calibration ensures the unit reaches and maintains the desired temperature, humidity, or CO₂ levels reliably.
Please ensure:
- The unit is left for a minimum of 12 hours upright and unpowered after delivery.
- Calibration is completed in accordance with manufacturer specifications before any use.
Failure to calibrate prior to use may result in inaccurate conditions and affect experimental integrity or compliance with laboratory standards.
This category of item contains refrigerants (F-gases) which are regulated under EU Regulation (EU) No 517/2014.
When sold to an EU-based buyer, confirmation of the buyer’s F-Gas registration on the EU F-Gas Portal is required prior to dispatch.
If the buyer is not registered, the item must be placed on hold until registration is completed.
This registration process can take up to 10 working days or more, subject to approval by the relevant authority.
In purchasing this item, the buyer accepts that additional compliance checks may need to be completed, and that shipping will be delayed until all requirements are met to ensure smooth customs clearance and regulatory compliance.
Due to this, we are unable to guarantee delivery times on this item.
We are happy to complete the sale transaction, and will work as quickly as possible with the buyer to ensure registration and documentation are completed.
Refrigerators will be transported in a variety of methods, including palletised couriers or direct transport "point of use". It is possible the internal refrigerant may have shifted during transport.
Allowing the unit to remain upright for at least 24 hours lets the refrigerant settle properly, preventing potential damage to the cooling system. Please ensure you allow sufficient settling time after receiving your delivery. Please also ensure you place the unit in its desired place of use before powering on for the first time, this is to prevent further movement post-delivery.
We suggest the below time periods are reached before powering on:
Fridges: 8hrs
Pharmaceutical Fridges: 8hrs
Freezers (≤ -20°C): 24hrs
Low Temperature (≤ -40°C): 48hrs
Ultra Low Temperature (≤ -80°C): 48hrs
Although all precautions are taken to prevent contamination, this equipment was once used in a Laboratory research setting. As such it was unused in an environment, or in a way, that handled potentially biological or chemical hazards.
This product must not be used for domestic purposes and must not be used for research purpose within a domestic location.
Return policy
Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.
NOTE: No cables, remotes, accessories, power supplies, external PCs, software media, hardkeys, consumables or any other items are included unless shown in the item photos or detailed above.