Description

This Sanyo CO2 Laboratory Incubator  Model - MCO-17AIC was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with 5% CO2 and a digital thermometer (not included). It is in reasonably good cosmetic condition with some marks from use. The plastic handle has snapped off the front of the unit but it is purely cosmetic.


The temperature was set to 37˚c and charged with 5% CO2 - It reached 36.5˚c before it seemed to stop but the thermometer read 37.9˚c and the CO2 was steady at 5%.

The temperature was then set to its maximum of 50˚c and it reached after around 4 hours with the thermometer reading 52.5˚c.


External dimensions - D72 W64 H91cm

Internal - D51 W49 H65cm

3 Shelves - 45 x 45cm




Item Details

Property Value Tested value
Type Floorstanding
Heating Method Air Jacket
Refrigeration No
Minimum Temperature (ºC) 5 Above Ambient
Maximum Temperature 50
CO2 Sensor Type IR Sensor
With Hot Air Sterilisation Unspecified
Humidifier Natural Evaporation from Humidifying Pan
With UV Lamp No
Physical Specifications
Interior Volume (L) 164
Delivery

Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.

Additional terms and conditions

Incubators may be transported via a range of delivery methods, including palletised courier networks or direct delivery to the intended location of use. During transit, internal sensors, fans, or control systems may be affected by vibration or movement.

To ensure optimal performance and accurate environmental conditions, it is essential that all incubators are allowed to stabilise upon arrival and are professionally calibrated before first use. Calibration ensures the unit reaches and maintains the desired temperature, humidity, or CO₂ levels reliably.

Please ensure:
- The unit is left for a minimum of 12 hours upright and unpowered after delivery.
- Calibration is completed in accordance with manufacturer specifications before any use.

Failure to calibrate prior to use may result in inaccurate conditions and affect experimental integrity or compliance with laboratory standards.

Return policy

Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.

NOTE: No cables, remotes, accessories, power supplies, consumables or any other items are included unless shown in the item photos or detailed above.