Intermed Microflow Pathfinder Class 2 Biological Safety Cabinet - Spares/Repair

Item Code: ITEM-46617

Condition: Spares or Repairs

Brand: InterMed

Location: Wales

NOTE - THIS IS A SPARES/REPAIRS ITEM
£ 200.00 exc. VAT (£ 240.00 inc. VAT)
1 in stock
If you are interested in this item or would like to place an order, please get in touch with us at , or by phone on +44 29 2086 4661.
Make us an offer / ask us a question
Description

Intermed Microflow Pathfinder Class 2 Biological Safety Cabinet - Spares/Repair


This item was removed from a university laboratory where it was surplus to requirements.


It powers on, with internal lights working. The UV light can be selected, but it does not appear to be fitted. The velocity control is functional. The air velocity gauge is broken, and the base doesn't seem to fit properly. The table is heavily stained, but this would not be visible with the cabinet on top.


Due to the faulty air velocity gauge and cosmetic condition, this item is listed as Spares/Repair.


Run hours: 33,032.0

Item Details

Property Value Tested value
Electrical Supply N/A 1-Phase
Plug Included? (1-Phase) N/A Yes - Standard UK 3-Pin Mains Plug (BS 1363)
PAT Test Result N/A Pass
PAT Test Date N/A 07-07-2025
Voltage N/A 240V
Year of Manufacture N/A n/a
Last Service Date N/A 01-08-2014
General Quality Checks
UV Lamp Fitted N/A No
Internal Lights Fitted (Not UV) N/A Yes
Internal Lights Tested (Not UV) N/A Yes
Internal Lights Test Result N/A Pass
Fan Switch Working N/A Yes
Fan Powers On N/A Yes
Airflow Observed N/A Yes
Airflow Measured N/A Yes
Measured Average Airflow Rate (M/S) N/A 1.12
Airflow Rate Result (Above 0.30M/S is a Pass) N/A Pass
Internal Power Sockets Fitted N/A No
Floor Stand Included N/A Yes
Assembly Required N/A Yes
All Bolts/Screws Included N/A Yes
Display Screen Fitted N/A Yes
Display Screen Working Correctly N/A Yes
Electronic Window Fitted N/A No
Delivery

Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.

Additional terms and conditions

These items are for spares/repair only, may be defective/unsafe, and are not intended for use.

We retain records of original source decontamination for all Safety Cabinets and Fume Hoods. Decontamination can consist of either Fumigation or Filter Removal. We are unable to provide condition report on any filters still present, we are unable to confirm their type or use suitability and we are unable to accept responsibility for overall function of the filters.
Filters should be assessed on receipt of goods and replaced by the user prior to use

This listing may include a stand/legs.
All cabinets are removed from their stands/legs during processing. Cabinets will not be mounted back onto their stands/legs for order fulfilment.

If a stand is included this may come as a separate piece, or dismantled in many pieces.

Return policy

Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.

NOTE: No cables, remotes, accessories, power supplies, consumables or any other items are included unless shown in the item photos or detailed above.