Thermo Scientific MSC-Advantage MSC 1.5 Class 2 Safety Cabinet with Stand Lab
Item Code: ITEM-42343
Condition: Used
£ 3,750.00 exc. VAT (£ 4,500.00 inc. VAT)
If you are interested in this item or would like to place an order, please get in touch with us at , or by phone on +44 29 2086 4661.
Description
Thermo Scientific MSC-Advantage MSC 1.5 Class 2 Safety Cabinet with Stand
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in very good cosmetic condition. The unit displayed 21,110 running hours. It is in good working order. (Socket tester not included.)
Includes:
- Full-width stand (supplied flat-packed) with a 68cm platform height
- 8 bolts for assembly
Order No.: 51028722
Serial No.: 41545966
Year: 2013
Item Details
Property | Value | Tested value |
---|---|---|
Electrical Supply | N/A | 1-Phase |
Plug Included? (1-Phase) | N/A | Yes - Standard UK 3-Pin Mains Plug (BS 1363) |
PAT Test Result | N/A | Pass |
PAT Test Date | N/A | 17-01-2025 |
Voltage | N/A | 240V |
Year of Manufacture | N/A | 2013 |
Last Service Date | N/A | unknown |
General Quality Checks | ||
UV Lamp Fitted | N/A | No |
Internal Lights Fitted (Not UV) | N/A | Yes |
Internal Lights Tested (Not UV) | N/A | Yes |
Internal Lights Test Result | N/A | Pass |
Fan Switch Working | N/A | Yes |
Fan Powers On | N/A | Yes |
Airflow Observed | N/A | Yes |
Airflow Measured | N/A | Yes |
Measured Average Airflow Rate (M/S) | N/A | 39 |
Airflow Rate Result (Above 0.30M/S is a Pass) | N/A | Fail |
Internal Power Sockets Fitted | N/A | Yes |
Tested Using Socket Tester | N/A | Yes |
Internal Sockets Test Result | N/A | Pass |
Floor Stand Included | N/A | Yes |
Assembly Required | N/A | Yes |
All Bolts/Screws Included | N/A | Yes |
Display Screen Fitted | N/A | Yes |
Display Screen Working Correctly | N/A | Yes |
Electronic Window Fitted | N/A | No |
Delivery
Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.
Additional terms and conditions
We retain records of original source decontamination for all Safety Cabinets and Fume Hoods. Decontamination can consist of either Fumigation or Filter Removal. We are unable to provide condition report on any filters still present, we are unable to confirm their type or use suitability and we are unable to accept responsibility for overall function of the filters.
Filters should be assessed on receipt of goods and replaced by the user prior to use
Return policy
Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.
NOTE: No cables, remotes, accessories, power supplies, consumables or any other items are included unless shown in the item photos or detailed above.