Air Science Purair EDU-Classic Ductless Fume Hood
Item Code: ITEM-61643
Condition: Used
Location: Wales
£ POA
This item is new in stock and has not been priced yet. Please make an offer below, or get in touch with us for a price at , or by phone on +44 29 2086 4661.
Description
Air Science Purair EDU-Classic Ductless Fume Hood with Activated Carbon Filter
This item was removed from a facility where it was surplus to requirements.
The unit is reported to be in good working order, although there are some issues that should be taken into consideration.
Last Service: 10/07/2025
Currently Installed Filter:
- Manufacturer: Filtco
- Type: Activated Carbon Filter
- Model: ASTM-110
- Serial Number: 640453164
- Installation Date: 05/10/2016
Please Note:
- Only the right-hand internal light is currently operational. The left-hand light is not working.
- The castor wheels are unstable, making the unit difficult to manoeuvre and level correctly.
- The installed activated carbon filter is dated October 2016. Its remaining service life and filtration effectiveness have not been verified, and replacement may be required before use.
Included Accessories:
- 2x Keys
Important: Although the unit is reported to be in working order, the condition of the wheels and the age of the installed filter should be taken into consideration. The unit should be inspected, and the filter suitability and airflow performance verified before being returned to laboratory use.
Item Details
| Property | Value | Tested value |
|---|---|---|
| PAT Test | ||
| Powers On | N/A | Yes |
| Electrical Supply | N/A | 1-Phase |
| Plug Included? (1-Phase) | N/A | Yes - Standard UK 3-Pin Mains Plug (BS 1363) |
| PAT Test Result | N/A | Pass |
| Voltage | N/A | 240V |
| PAT Test Date | N/A | 16-11-2026 |
| Recertification Initial Checks | ||
| Overall Cosmetic Condition | N/A | Good |
| Stand Condition | N/A | Pass |
| Work Area Condition | N/A | Pass |
| Recertification System Checks | ||
| Display Screen | N/A | N/A |
| Fan Switch | N/A | Pass |
| Internal Lights(Not UV) | N/A | Fail |
| UV Lights | N/A | N/A |
| Electronic Window Working Level Stop | N/A | N/A |
| Recertification Tests | ||
| Airflow Rate Result (Above 0.25M/S is a Pass) | N/A | Pass |
| Internal Power Sockets | N/A | N/A |
| Safety Features | ||
| Emergency Stop Safety Check | N/A | N/A |
| Service Details | ||
| Last Service Date | N/A | 10/07/2025 |
| Other Details | ||
| Floor Stand Included | N/A | Yes |
| Assembly Required | N/A | No |
| UV Lamp Fitted | N/A | No |
Delivery
The price includes free economy delivery (3-5 working days) to Mainland UK Postcodes EXCLUDING the following postcodes:
AB31-38, AB40-52, AB54-56, AB63 IV1-28, IV30-32, IV36-56, IV63 KA27-28 KW1-17 PA20-38, PA41-49, PA60-78 PH4-44, PH49-50 PO30-41 TR21-25 BT, GS, GY, HY, IM, JE, TDCU, ZE
If you live in one of the above postcodes please enquire for a shipping quote. Your item will be carefully packed and dispatched within 24 hours (Mon–Fri) of receiving payment.
International buyers please contact us for an overseas shipping quote.
Additional terms and conditions
We retain records of original source decontamination for all Safety Cabinets and Fume Hoods. Decontamination can consist of either Fumigation or Filter Removal. We are unable to provide condition report on any filters still present, we are unable to confirm their type or use suitability and we are unable to accept responsibility for overall function of the filters.
Filters should be assessed on receipt of goods and replaced by the user prior to use
Return policy
Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.
NOTE: No cables, remotes, accessories, power supplies, external PCs, software media, hardkeys, consumables or any other items are included unless shown in the item photos or detailed above.