Our Water Baths, Chillers, and Benchtop Cooling category offers a selection of high-quality, second-hand equipment designed for precise temperature control in laboratory and research applications. Specializing in water baths, recirculating chillers, and benchtop cooling units, our range is ideal for maintaining stable temperatures during experiments and sample processing.


Equipment undergoes varying levels of testing, including functionality checks and temperature performance assessments, ensuring reliable solutions for your cooling and temperature control needs.


Items 51 to 82 of 82

Image of HasKris Recirculating Chiller S/n HA007835 Lab Spares/Repairs

£ 500.00 (ex. VAT) 1 in stock

HasKris Recirculating Chiller S/n HA007835 Lab Spares/Repairs

ITEM-37147

This HasKris Recirculating Chiller S/n HA007835 was removed from a university lab where it was surplus to requirements.


The unit powers up but was not tested further at our facility.


It is in good cosmetic condition, with some marks from use.


Some of the components have been removed, it is sold for spares/repairs

Image of Applied Thermal Control K4 K410000W Industrial Recirculating Chiller Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Applied Thermal Control K4 K410000W Industrial Recirculating Chiller Lab Faulty

ITEM-37631

Applied Thermal Control K4 K410000W Industrial Recirculating Chiller


This item was removed from a university where it was surplus to requirement.


It is in very good cosmetic condition and powers up.


The previous owner has reported that the recycling water has been contaminated with coolant.

Therefore, it will need to be serviced for recommissioning and is listed as Spares/Repairs as a result.


Product Details:


Model K410000W

Serial No. 190348



4.5kw cooling capacity

Temp range 4 to 35˚C

17L/min flow rate

10 bar max

Image of Lauda Alpha RA 8 Cooling Thermostatic Water Bath Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Lauda Alpha RA 8 Cooling Thermostatic Water Bath Lab Spares/Repairs

ITEM-38840

Lauda Alpha RA 8 Cooling Thermostatic Water Bath


This was removed from a university lab where it was surplus to requirements.


The unit powers up but is not in good working order. The unit will not heat, and was not accurate when chilling.


It is in good cosmetic condition with minor marks.

Image of Buchi Distillation Chiller B-741 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Buchi Distillation Chiller B-741 Lab Spares/Repairs

ITEM-41104

Buchi Distillation Chiller B-741


This was removed from a university lab where it was surplus to requirements.


The unit did not power up in tested and we were informed that it was out of order and non-function prior to collecting it.


It is sold for spares/repairs

Image of Fisher Scientific Isotemp Recirculating Chiller Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Fisher Scientific Isotemp Recirculating Chiller Lab Spares/Repairs

ITEM-41106

Fisher Scientific Isotemp Recirculating Chiller


This was removed from a university lab where it was surplus to requirements.


The unit powers up but the lab confirmed it was not pumping correctly, and therefore not cooling correctly prior to collection.


It is sold for spares/repairs.



Image of Thermo Electron Neslab Merlin M100 Recirculating Chiller Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Electron Neslab Merlin M100 Recirculating Chiller Lab

ITEM-41107

Thermo Electron Neslab Merlin M100 Recirculating Chiller


This was removed from a university lab where it was surplus to requirements.


The unit powers up but is not cooling effectively. The lab confirmed it was not in working order prior to removal.


It is sold for spares/repairs.

Image of Buchi Distillation Chiller B-741 Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Buchi Distillation Chiller B-741 Lab

ITEM-41489

Buchi Distillation Chiller B-741 Lab


This item was removed from a university where it was surplus to requirement.


It powers on but is in poor cosmetic condition, we are unable to test it further at our facility.


The unit is sold for spares/repairs as we believe it will need quite a bit of remedial action to get it working properly.


It is missing one of is feet.

Image of NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs

ITEM-41633

NESLAB Coolflow CTF33 Refrigerated Recirculator Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, although we were unable to set the desired temperature due to a display fault.


Therefore, it is listed as Spares/Repair.

Image of NesLab CryoBath CB-60 Refrigerated Water Bath Chiller Lab

£ 495.00 (ex. VAT) 1 in stock

NesLab CryoBath CB-60 Refrigerated Water Bath Chiller Lab

ITEM-35997

NesLab CryoBath CB-60 Refrigerated Water Bath Chiller


This was removed from a university lab where it was surplus to requirements.


The unit powers up and is in good working order.


It is in good cosmetic condition with minor marks.

Image of Grant SBB Aqua 12 Plus Water Bath Lab

£ POA No longer available

Grant SBB Aqua 12 Plus Water Bath Lab

ITEM-42220

This item is new in stock. Please enquire for further details.

Image of Perkin Elmer C6 Chiller  Pyris Cooling Accessory  Lab

£ 440.00 (ex. VAT) 1 in stock

Perkin Elmer C6 Chiller Pyris Cooling Accessory Lab

ITEM-35527

Perkin Elmer C6 Chiller


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test tit further. It is in good cosmetic condition with minor marks from use.

Image of Neslab RTE-101 Refrigerated Water Bath Circulator  Lab

£ 405.00 (ex. VAT) 1 in stock

Neslab RTE-101 Refrigerated Water Bath Circulator Lab

ITEM-19383

This Neslab RTE-101 Refrigerated Water Bath Circulator was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested with a digital thermometer (not included). It was first set to the minimum temp of -30C. It dropped to -16.8C after about 8 hours of running. It was then set to 37C and our thermometer read 36. It reached the boiling point with no problems.


The unit is in reasonably good cosmetic condition but has some marks from use.


Image of Grant Sub Aqua Pro Water Bath SAP18 Lab

£ 400.00 (ex. VAT) 1 in stock

Grant Sub Aqua Pro Water Bath SAP18 Lab

ITEM-35125

Grant Sub Aqua Pro Water Bath SAP18


This item was removed from a university where it was surplus to requirement.


The unit powers up and has been tested with a digital thermometer (not included).


It is in good cosmetic condition.

Image of Grant JB Aqua 18 Plus Water Bath Lab

£ 400.00 (ex. VAT) 1 in stock

Grant JB Aqua 18 Plus Water Bath Lab

ITEM-41673

Grant JB Aqua 18 Plus Water Bath Lab


This item was removed from a university where it was surplus to requirement.


The unit powers up and is in good working order (thermometer not included).


It is in good cosmetic condition, however the handle has snapped off, this does not affect its functionality.

Image of LKB Bromma 2219 Multitemp II Thermostatic Circulator Lab

£ 375.00 (ex. VAT) 1 in stock

LKB Bromma 2219 Multitemp II Thermostatic Circulator Lab

ITEM-39070

This LKB Bromma 2219 Multitemp II Thermostatic Circulator was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order. It was tested with a digital thermometer (not included).


It is in reasonably good cosmetic condition.

Image of Grant JB Aqua 26 Water Bath 26 Litre Lab

£ POA No longer available

Grant JB Aqua 26 Water Bath 26 Litre Lab

ITEM-45151

This item is new in stock. Please enquire for further details.

Image of Fisher Scientific DMU12 12L Water Bath Lab

£ 300.00 (ex. VAT) 1 in stock

Fisher Scientific DMU12 12L Water Bath Lab

ITEM-41486

Fisher Scientific DMU12 12L WaterBath Lab


This item was removed from a university where it was surplus to requirement.


The unit powers up and is in good working order (thermometer not included).


No lid included.

Image of Memmert WNE 10 Water Bath 10L Lab

£ 295.00 (ex. VAT) 1 in stock

Memmert WNE 10 Water Bath 10L Lab

ITEM-35873

Memmert WNE-10 Water Bath 10L


This was removed from a university lab where it was surplus to requirements.


The unit is in full working order. it has been tested against a digital thermometer (not included).


It is in reasonable cosmetic condition but is very stained inside.

Image of Amersham Biosciences MultiTemp III Chiller Circulator Water Bath Lab

£ 280.00 (ex. VAT) 1 in stock

Amersham Biosciences MultiTemp III Chiller Circulator Water Bath Lab

ITEM-25191

This Amersham Biosciences MultiTemp III Chiller Circulator Water Bath was removed from a university lab where it was surplus to requirements.



The unit powers on and is in good cosmetic condition. There is some pitting inside the bath of the unit from general use.


The unit has been tested with a digital thermometer (not included).

When set to -10ºC our thermometer read -9.3ºC

When set to 4ºC our thermometer read 4.5ºC

When set to 37ºC our thermometer read 37.6ºC

When set to 45ºC our thermometer read 45.5ºC


45ºC was the highest temperature the unit could be set to.




Image of Grant JB Aqua 12 Plus Water Bath Lab

£ 280.00 (ex. VAT) 1 in stock

Grant JB Aqua 12 Plus Water Bath Lab

ITEM-41822

Grant JB Aqua 12 Plus Water Bath Lab


This item was removed from a university where it was surplus to requirement.


The unit powers up and is in good working order (thermometer not included).


It is in good cosmetic condition, with some rust damage internally.

Image of VWR 6L Model VWB6 Water Bath  Lab

£ 260.00 (ex. VAT) 1 in stock

VWR 6L Model VWB6 Water Bath Lab

ITEM-35999

This was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order (digital thermometer not included).


It is in good cosmetic condition with minor marks.


Includes manual

Image of Haskris Recirculating Chiller Model: R050 Lab

£ 255.00 (ex. VAT) 1 in stock

Haskris Recirculating Chiller Model: R050 Lab

ITEM-22031

This Haskris Recirculating Chiller Model: R050 was removed from a university lab where it was surplus to requirements.


The unit powers up and the warning light indicates the tank is full. It has not been tested further.


The item is in reasonable cosmetic condition but there are some stains/scratches on the outer panels as well as rust and other water damage.


Image of VWR Clifton NE2-22D 22L Waterbath Lab

£ 250.00 (ex. VAT) 1 in stock

VWR Clifton NE2-22D 22L Waterbath Lab

ITEM-45278

VWR Clifton NE2-22D 22L Waterbath Lab


This item was removed from a university where it was surplus to requirement.


The unit powers up and is in good working order (thermometer not included).


It is in good cosmetic condition


There is no lid included.

Image of VWR 6L Water Bath Model VWB6 Lab

£ 250.00 (ex. VAT) 1 in stock

VWR 6L Water Bath Model VWB6 Lab

ITEM-35998

VWR 6L Water Bath Model VWB6


This was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order (digital thermometer not included).


It is in good cosmetic condition with minor marks.


Includes manual


Image of FisherBrand Grant FB60307 Heated Laboratory Water Bath lab

£ 235.00 (ex. VAT) 1 in stock

FisherBrand Grant FB60307 Heated Laboratory Water Bath lab

ITEM-27768

This FisherBrand Grant FB60307 Heated Laboratory Water Bath was removed from a university lab where it was surplus to requirements.


The unit powers on and is in good cosmetic condition. it was tested with a digital thermometer (not included).


Set the temp at 37ºC, our thermometer read 38.2ºC (units internal thermometer read 37.4ºC)

Set the temp at 55ºC, our thermometer read 55.9ºC (units internal thermometer read 55.6ºC)

Set the temp at 99ºC, our thermometer read 93.6ºC (units internal thermometer read 96.1ºC)


Accessories:


Plastic Inserts;


1x Melform, L46cm x W25cm x H2cm

2x Bourgeat, L25cm x W10cm x H2cm

2x Bourgeat, L25cm x W19cm x H2cm


Lid: L39cm x W29cm x H18cm 


Interior Dims:

L50cm x W30cm x D20cm


Image of Maestro CH1 Undersink Water Chiller Lab

£ 215.00 (ex. VAT) 4 in stock

Maestro CH1 Undersink Water Chiller Lab

ITEM-10520

This Maestro CH1 Undersink Water Chiller was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further.


It is in good cosmetic condition with some marks from use.


Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving upon purchase before it is shipped, we would be happy to provide this.

Image of Bohlin Instruments Re-Circulator  Model - KTB50 Lab

£ 135.00 (ex. VAT) 1 in stock

Bohlin Instruments Re-Circulator Model - KTB50 Lab

ITEM-20675

Bohlin Instruments Water Bath Re-Circulator Model - KTB 50


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we have not carried out any further tests on this unit as there are no clear temperature controls for the fluid. We suspect this must be controlled by a Bohlin Rheometer (which we do not have).


It is in reasonably good cosmetic condition with some marks from use.

Image of New Brunswick Water Bath Shaker  Model - Classic C76 Lab

£ 110.00 (ex. VAT) 1 in stock

New Brunswick Water Bath Shaker Model - Classic C76 Lab

ITEM-19905

New Brunswick Water Bath Shaker Model - Classic C76


This was removed from a university lab where it was surplus to requirements.


The unit powers up and the shaker has been tested to the max speed of 300rpm. The water bath has been tested with a digital thermometer (not included).


It was set to 37˚C which it reached after about half an hour. It was then set to the max of 80˚C. It reached 75˚C before it stopped getting any hotter.


It is in good cosmetic condition but has some marks from use.


Unit appears to be in good working order.

Image of Lawler Model RU-390-6 Rust Test Apparatus Liquid Bath

£ 100.00 (ex. VAT) 1 in stock

Lawler Model RU-390-6 Rust Test Apparatus Liquid Bath

ITEM-31750

Lawler Model RU-390-6 Rust Test Apparatus Liquid Bath


This was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order.


It is in good cosmetic condition with minor marks from use.

Image of PerkinElmer Furnace Cooling-System Lab

£ POA 1 in stock

PerkinElmer Furnace Cooling-System Lab

ITEM-41167

This item is new in stock. Please enquire for further details.

Image of Huber K6 Re-Circulating Chiller With Pilot One Thermostat Lab

£ POA 1 in stock

Huber K6 Re-Circulating Chiller With Pilot One Thermostat Lab

ITEM-45093

This item is new in stock. Please enquire for further details.

Image of Huber MiniChiller Recirculating Chiller Lab

£ POA 1 in stock

Huber MiniChiller Recirculating Chiller Lab

ITEM-45185

This item is new in stock. Please enquire for further details.

Items 51 to 82 of 82