Medical Imaging
Items 1 to 9 of 9

£ 12,000.00 (ex. VAT) 1 in stock
Bruker Skyscan 1178 In Vivo Micro CT Fast X-RAY Microtomograph Lab
ITEM-46256
Bruker Skyscan 1178 In Vivo Micro CT Fast X-RAY Microtomograph
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it further due to limitations at our facility.
According to information provided by the previous owner, the unit was last used approximately eight or more years ago. There were no known faults at the time of last use, however it is likely due to the extended period of inactivity, the x-ray tube may no longer be functional and may require replacement. We are unable to confirm this.
Disclaimer; Users should seek technical expertise before attempting to power on, as inactive tubes may present a risk of cracking due to uneven heating.
Includes:
- Manual

£ 4,750.00 (ex. VAT) 1 in stock
Digital CR Reader CR30-XM With Cassettes Lab
ITEM-45011
Digital CR Reader With Cassettes
This item was removed from a university where it was surplus to requirement.
The item is in good cosmetic condition.
It powers on, we are unable to conduct further testing at our facility.
The previous client has stated it was in working order prior to removal.
No software is included.
S/N: 3985

£ 4,000.00 (ex. VAT) 1 in stock
Rigaku Ultima III X-ray Diffractometer (XRD) w/SA-HEM3 6 Station Holder Lab
ITEM-44950
Rigaku X-ray Diffractometer (XRD) Ultima III
This system was removed from a university lab where it was surplus to requirements.
The system is in reasonable used cosmetic condition. It has not been powered on at our site due to our on-site risk assessments surrounded X-Rays.
The unit was working when put into storage in 2018.
Various components and parts are included as listed below, along with a PC setup, although no Rigaku software programs appear to be installed on the PC.
However, there are the following software disks included:
- Rigaku Basic Software (Cat No.: 9240J101)
- Rigaku TTRAX3 and Ultima3 Software (Cat No.: 9240J101)
- Rigaku Special Order Software (U30megaP) (Cat No.: 9999)
System Specifications:
- Model: Ultima III
- Cat No.: 2035M410
- Serial No.: DD3654N
- 6 Station Holder
- Model: SA-HEM3
- Cat No.: 4057J101
- Serial No.: 00563702
- Patlite Beacon
- Model: LMS-L (SN-06X03M)
- Rigaku DC Motor Controller
- SN: DD12866
- Rigaku Long Fine Focus
- Type: R01-29-0202
- NC: 9430 022 73201
- No. DK 402688
- Rigaku CBO Cross Beam Optics
- Cat No.: 2220B101
- SN: DD12793
- Additional Rigaku parts:
- Cat No.: 5738E402 (SN-DD061813)
- Cat No.: 2155G101 (SN-DD12804)
- Cat No.: 4601K831 (SN-DD12154)
- Cat No.: 4253A101 (SN-DD11586
- Vexta Stopping Motor
- Model: PK543-A
- SN: UR70J32307
PC Setup:
- Dell Optiplex 9020 with monitor, keyboard, and mouse
- The PC is in working order with all passwords cleared. It contains a few Rigaku files, but no software programs appear to be installed.
Included Manuals/Software:
- 2 x Rigaku D/MAX 2000/PC Series Instruction Manual
- X-Ray Diffractometer Instruction Manual
- Rigaku Basic Software (Cat No.: 9240J101)
- Rigaku TTRAX3 and Ultima3 Software (Cat No.: 9240J101)
- Rigaku Special Order Software (U30megaP) (Cat No.: 9999)
Loose spare parts included:
- Rigaku Cat No.: 2701E201 (SN-AD08851)
- Container of round parts: Rigaku 900003 SH, w/Groove
- 2 x Small containers with unknown parts
- Scintag Generator Key
- Key labeled: "Microscope"
- Container of small metals, including:
- 1 x Bag labeled "Silicon"
- 1 x 640d Silicon Powder
- 2 x Tubs UCAR Spectroscopic Powder
- 1 x Tub labeled "Tung Flake"
- Approximately 20 x small containers of Silicon metal

£ 3,000.00 (ex. VAT) 1 in stock
DORADOnova MR3T Adjustable Laser Bridge MRI Compatible Lab
ITEM-42136
DORADOnova MR3T Adjustable Laser Bridge MRI Compatible
This system was removed from a university laboratory where it was surplus to requirements.
The Fujitsu PC and the LAP PSU V-BOX DORADOnova MR were powered on. We were unable to conduct further testing at our facility.
The previous client has stated the system was in working order prior to removal.
Includes:
- Element Infopia with test strips
- Fujitsu PC (Note: System has a touchscreen monitor; the additional monitor was only used for testing purposes and is not included)
- Software: MEDRAD Performance for Life, Spectris Solaris EP Operation Manual, LAP Laser ARGO NAVIS, CARINAsim Pictor 3D, CARINAsim DORADO, CARINAiso (Version 1.2.0 and 1.2.2)
Models and Serial Numbers:
- DORADOnova MR3T Laser Bridge: Model No. 0007597-0067, S/N 0062034
- V-BOX DORADOnova MR: Model No. 005626, S/N 0061523

£ 2,500.00 (ex. VAT) 1 in stock
Hologic Delphi QDR 4500 DEXA Scanner (X-Ray Bone Densitometer) Lab
ITEM-46520
Hologic Delphi QDR 4500 DEXA Scanner (X-ray Bone Densitometer)
This item was removed from a university laboratory where it was surplus to requirements.
The transformer powers on, but the main unit has not been powered up due to safety limitations with X-ray equipment.
The previous owner has stated a QA was last completed in November 2023.
There are no known faults.
The PC system has the following software installed (Hologic Discovery QDR Series).
It is in reasonable cosmetic condition but it well used.

£ 1,000.00 (ex. VAT) 1 in stock
Civco Radiotherapy Positioning System Carbon Fiber MR Compatible Lab
ITEM-42133
Civco Radiotherapy Positioning System – Carbon Fibre, MR Compatible
This system was removed from a university laboratory where it was surplus to requirements.
It includes multiple interchangeable components, including six smaller seats, and two larger seats.
The system comprises a radiotherapy flat couch top, immobilisation devices, and black foam squares. One red Civco knee fix has minor wear, with small rips and scrapes on the back.
Includes:
- MR-compatible radiotherapy flat couch top (compatible with GE Syngo PET-MR system)
- Radiotherapy kit with red moulds for immobilisation
- Radiotherapy immobilisation device (CIVCO box)
- Radiotherapy couch top (long flat box)
- 2 x CIVCO black foam squares (SN 301055)
- Various interchangeable seating components
Serial No.: 20070102/70009-PSR-2C-14

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Siemens Aspen Advanced Acuson Ultrasound Machine Spares/Repair
ITEM-46577
Siemens Aspen Advanced Acuson Ultrasound Machine (Spares/Repair)
This item was removed from a university laboratory where it was surplus to requirements.
The main unit powers on, but the screen began flickering before eventually failing.
The casing is loose in places and the hard drive has been removed. Therefore, it is listed as Spares/Repair.
Includes:
- Sony Graphic Printer UP-895MD – powers on
- Sony Video Cassette Recorder SVO-9500MDP – powers on
Model: Siemens Aspen Acuson

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ POA 1 in stock
Philips HD11 XE Ultrasound System Lab
ITEM-37858
Philips HD11 XE Ultrasound System
This system was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition with minimal signs of wear. However, the system encounters an error during startup. The message displayed reads: "The instrument has detected an internal error and is collecting information to help diagnose the problem. The restart control will be enabled when the information has been collected." Restarting the system results in the same error, and access to the setup or settings is blocked.
Therefore, this system is listed as Spares/Repair.
Includes:
- Philips HD11 Service Manual CD
- Back-up S/W Rev 1.1.1 (dated 21/6/06) CD
- Philips HD11 XE Ultrasound System User Information CD
- Philips HD11 XE Ultrasound System User Information Update (Physical Manual)
- Philips HD11 XE Ultrasound System Quick Guide (Physical Manual)
Model: HD11 XE
Serial No.: US20670402

£ POA 1 in stock
Two B-K Merlin Ultrasound Transducer Probes Type 8561 And Type 8545-S Lab
ITEM-41988
Two B-K Merlin Ultrasound Transducer Probes Type 8561 And Type 8545-S Lab
These items were removed from a university lab, where they were surplus to requirement.
The previous client has informed us that both Transducer Probes were in working order prior to removal.
Both items are in good cosmetic condition and include the Original hard cases shown.
B-K Merlin Type 8561
Serial No. 1841428
B-K Merlin Type 8545-S
Serial No. 1831559
Items 1 to 9 of 9