Thermo Finnigan Trace GC Ultra, Delta Plus XP, Combustion 3, Lab
Item Code: ITEM-15729
Condition: Used
Brand: Thermo Finnigan
£ POA
SOLD - Unfortunately this item is no longer available. However, we may have similar items available for sale. Please get in touch with us at , or by phone on +44 29 2086 4661.
Description
This system was removed from a university mass spectrometry facility that was closing down.
As part of a university efficiency drive departmental mass spectrometry facilities were closing and being replaced with central facilities. This system was no longer required. Please note the table shown in the photos is NOT included.
It was in full working order, and only used by a relatively small department, but was maintained by a dedicated facility technician.
Whilst we have not tested every part, we were assured the system was essentially in good working order, though given the number of components, some minor servicing might be required. We are happy to discuss warranties with you to provide you assurances for the purchase.
The system consists of:
1 x Dell OptiPlex 7050 Windows 7 PC with Isodat 3.0 software installed.
It comes with a screen, keyboard, and mouse.
The unit powers up fine and appears to work as it should.
It has various interface cards installed.
1 x Thermo Finnigan Delta Plus XP.
The unit is in good cosmetic condition.
1 x Thermo Finnigan Trace GC Ultra.
Version 4.07 2003.
1 x Peltier Thermostat MN 03-00 Rev C.
This unit doesn't appear to power up and has not been tested.
1 x CTC Analytics MN 01-00 Rev E.
The unit powers up but was not tested any further.
1 x Thermo Finnigan GC Box.
The unit powers on but has not been tested further.
1 x Thermo Finnigan Gas Bench 2.
It powers up fine but the power switch is faulty. It works but will require replacement. Part of the readout LED is dim so the numbers don't appear totally correctly.
1 x Thermo GC/TC Reactor OD.
The display seems to just flash 1999 when powered up. The display is also a little dim.
1 x Thermo Finnigan GC Combustion/Interface III.
The unit powers up fine but the Ox Reactor screen flashes 1599 and part of the LED is a bit dim. The red Reactor screen shows 35.
1 x Agilent Technologies ADM1000 Universal Gas Flowmeter.
It requires a 9v battery to run. It powers up and appears to run fine.
1 x Claude Lyons TS Voltage Stabiliser.
TS 333 10.
The unit is in good cosmetic condition but the back panel is slightly bent. We were unable to test this unit.
1 x Box of various cables for the system plus used pipework. This will probably all require replacement.
Also included are some software CDs. We believe these are for the PC OS.
1 x Thermo Finnigan Sample Tray Thermostated.
The unit powers up and is in good, used cosmetic condition, but it does have signs of use.
The main cables have been slightly cut, but have been taped and still appear to work fine.
The setpoint was set to 37degC but the block well exceeded that temperature so we're not sure how accurate or stable it is. It comes attached to some sort of base unit but this can be removed easily if need be.
The heating bock measures: 33cm L x 32.7cm W x 13.5cm High.
The tube holes are 16mm x 86.3mm without the cover and approx 8.9mm with the cover which appears to be a hole size reducer.
There are 96 holes.
Please note that the table in the main picture is NOT included in the sale.
Delivery
Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.
Return policy
Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days subject to our terms and conditions. International buyers will have to pay return shipping.
NOTE: No cables, remotes, accessories, power supplies, consumables or any other items are included unless shown in the item photos or detailed above.