Infors HT AJ 120 Multitron Triple Stack Incubator Shaker Lab Spares/Repairs
Item Code: ITEM-16228
Condition: Spares or Repairs
Brand: Infors HT
Location: Wales
NOTE - THIS IS A SPARES/REPAIRS ITEM
£ POA
SOLD - Unfortunately this item is no longer available. However, we may have similar items available for sale. Please get in touch with us at , or by phone on +44 29 2086 4661.
Description
This Infors HT Multitron Triple Stack Laboratory Incubator Shaker was removed from a university lab where it was surplus to requirements.
The units have been tested and function as follows.
Top Unit - The unit powers up and the refrigeration unit boots up and you can hear the compressor working. It cooled to 4.2˚C relatively quickly. It will also heat up to 24˚C but it will not reach any higher than that. The shaker works up to 400rpm but it gets a bit unsteady after 350+rpm. The internal lights are also not working. The temperature warning alarm works and shows a HI/LO warning. The shaker plate is included.
Middle Unit - There is no power to this unit and it will not turn on at all. There is also no shaker plate inside.
Bottom Unit - The unit powers up and the refrigeration unit boots up and you can hear the compressor working. It cooled to 4.4˚C relatively quickly. The unit however does not heat and remains at ambient temperature. It showed 16.3˚C on the display but the room it was in was much colder. The shaker works up to 400rpm but it gets a bit unsteady after 350+rpm. This unit is missing some internal panels and is missing its thermal cut-off dial so this cannot be controlled. The temperature warning alarm works and shows a HI/LO warning.
Overall it is in reasonable cosmetic condition but is missing bits and pieces and has marks from use.
It is sold for spares or repairs.
Delivery
Free shipping is not available on this product. This item will be shipped by pallet delivery. Please contact us for a domestic or overseas shipping quote.
Additional terms and conditions
These items are for spares/repair only, may be defective/unsafe, and are not intended for use.
Incubators may be transported via a range of delivery methods, including palletised courier networks or direct delivery to the intended location of use. During transit, internal sensors, fans, or control systems may be affected by vibration or movement.
To ensure optimal performance and accurate environmental conditions, it is essential that all incubators are allowed to stabilise upon arrival and are professionally calibrated before first use. Calibration ensures the unit reaches and maintains the desired temperature, humidity, or CO₂ levels reliably.
Please ensure:
- The unit is left for a minimum of 12 hours upright and unpowered after delivery.
- Calibration is completed in accordance with manufacturer specifications before any use.
Failure to calibrate prior to use may result in inaccurate conditions and affect experimental integrity or compliance with laboratory standards.