All Products
Items 1751 to 1800 of 2573

NEW ITEM
NEW ITEM
£ 535.00 (ex. VAT) 1 in stock
17 Boxes of Mixed FisherBrand SureOne Pipet Tips Non filter + Aerosol Barrier
ITEM-35501
17 Boxes of Mixed FisherBrand SureOne Pipet Tips Non filter + Aerosol Barrier
Individually sealed and brand new.
10 packs of 96 tips per box amounting to 960 tips per box
Sizes are as follows:
100µl- 5 boxes (4800 tips)
300µl- 3 boxes (2880 tips)
10µl- 3 boxes (2880 tips)
200µl- 1 box (960 tips)
20µl- 2 boxes (1920 tips)
1000µl -3 boxes (2880 tips)
Also individually theres an additional:
10µl- 3 packs (288 tips)
20µl- 3 packs (288 tips)
200µl- 3 packs (288 tips)
100µl- 6 packs (576 tips)
300µl- 5 packs (480 tips)
Mixed expiry dates between 2026-2028

£ 525.00 (ex. VAT) 1 in stock
Lab Armor Bead Bath Type 74200-714 Lab
ITEM-48317
Lab Armor Bead Bath Type 74200-714 Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
The lab confirmed it was in working order prior to removal.

£ 510.00 (ex. VAT) 1 in stock
TQ TD1050 Steam Engine Trainer Teaching Rig
ITEM-31868
TQ TD1050 Steam Engine Trainer Teaching Rig
This was removed from a university lab where it was surplus to requirements.
The system powers up and is in full working order.
System Parts:-
TD1050 General Assembly
TQ160508-001
TD1050 - DTS2 Torque/Speed Display Unit
TQ165554-001
TD1050-DT1 Temperature Display
TQ160508-001
VDAS-F - VDAS Frame Mounted Version
TQ158991-010
Grosvenor Pump
Model - 5520
SN - 21248
Dynatherm Part no. 40993
SN - 13057-1

£ 510.00 (ex. VAT) 1 in stock
Triple Red Model Duo Organic 60 Ultra Pure Water Purification System Lab
ITEM-45398
Triple Red Duo Organic 60 Ultra Pure Water Purification System
This item was removed from a university where it was surplus to requirements.
The item is in good cosmetic condition and powers on. However, we were unable to perform further testing at our facilities.
Please note: The power supply is not included. Testing was carried out using a power supply from another unit.
Included Components:
- Avidity Carbon Pre-Filter
- P/N: TR-2057
- Install Date: 26/7/23
- Avidity Cartridge Pack
- P/N: TR-2050
- Install Date: 26/7/23
- Avidity Cartridge Polisher
- P/N: TR-2051
- Install Date: 26/7/23
Specifications:
- Model: Organic 60 Ultra Pure Water Purification System
- Serial No.: Not provided

£ 510.00 (ex. VAT) 1 in stock
Purite Select Purification System L300150 with Storage Tank Lab
ITEM-35809
Purite Select Purification System L300150 with Storage Tank
This was removed from a university lab where it was surplus to requirements.
The system powers up and pressurises but was not tested further.
It is in reasonable cosmetic condition with marks from use.
Both filters, Pretreat 8 and Puripac PP8 expired 15/02/23
100L Storage Tank

£ 510.00 (ex. VAT) 1 in stock
Thermo Scientific Model Compact LidPark P00155 Lab
ITEM-37179
Thermo Scientific Compact LidPark P00155
This item was removed from a university where it was surplus to requirement.
It is in very good cosmetic condition and powers up, we are unable to test it further at our facility.
Model: LidPark P00155

£ 510.00 (ex. VAT) 1 in stock
Jobin Yvon Horiba CCD-3500V Detection Unit Lab
ITEM-35891
Jobin Yvon Horiba CCD-3500V Detection Unit
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in good cosmetic condition with minor marks.

£ 510.00 (ex. VAT) 1 in stock
Panasonic Model Type AW-HE60 CCTV Cameras
ITEM-37270
Panasonic AW-HE50 CCTV Cameras
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers on.
The previous client has stated it was in full working order prior to removal.
This item was tested with an in-house power supply cable. (not included.)

£ 505.00 (ex. VAT) 1 in stock
Soxtec Avanti 2050 Auto Fat Extraction System Lab
ITEM-24536
This Soxtec Avanti 2050 Auto Fat Extraction System was removed from a university lab where it was surplus to requirements.
Included are;
1 x Foss Tecator 2050 Soxtec Avanti Auto Extraction Unit
Part no. 10007330
1 x Foss Tecator 2050 Drive Unit
Part no. 10007338
The item powers on with the drive unit supplying power and controlling the extraction unit. It was not tested further. It seems to be missing a control unit.
The item is in reasonably good cosmetic condition with some marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 505.00 (ex. VAT) 1 in stock
Airwolf 3D NW3D HDX 3-D Printer Lab Spares/Repairs
ITEM-37979
Airwolf 3D NW3D HDX 3-D Printer Lab
This item was removed from a university where it was surplus to requirement.
The back panel is missing and, the wires are exposed, resulting in a visual PAT fail.
Due to the condition stated above, this item is listed as Spares/Repair.
Also included are the following:
- Power lead
- Data cable

£ 505.00 (ex. VAT) 1 in stock
Hybaid Maxi 14 Hybridisation Oven Lab
ITEM-26176
Hybaid Maxi 14 Hybridisation Oven
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order, but may need calibrating to your equipment. It was tested with a digital thermometer (not included).
It is in good cosmetic condition with minor marks.
Internal Dimensions - D34 W34 H50cm

£ POA 1 in stock
Lauda Alpha RA 8 Cooling Thermostatic Water Bath Lab Spares/Repairs
ITEM-38840
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
VG Scientific Wien Mass Filter for Ion Beam Filtering UHV Lab
ITEM-19542
This item is new in stock. Please enquire for further details.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Julabo FL300 Recirculating Chiller - Spares/Repair Lab
ITEM-47581
Julabo FL300 Recirculating Chiller – Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
The unit shows minimal wear, with both of the top catches on the lid broken; this does not affect physical operation of the doors.
The cable is damaged, and the unit will not power on, so it is being sold for spares or repair.
Model: FL300

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MPR-1410 Pharmaceutical Refrigerator - Spares/Repair Lab
ITEM-48392
Sanyo MPR-1410 Pharmaceutical Refrigerator – Spares/Repair
This item was removed from a university where it was surplus to requirements.
In poor cosmetic condition, with rust present at the bottom inside the unit and on the door hinges.
Powers on, but the internal light is non-functional, and no cooling was observed after running for over an hour.
Therefore, it is listed as Spares/Repair

£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter SW 40 TI 40,000 RPM Swinging Bucket Rotor Lab
ITEM-48418
Beckman Coulter SW 40 TI 40,000 RPM Swinging Bucket Rotor Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and remains untested.
Specifications;
- Platform: Floor Prep
- Rotor Type: Swinging-Bucket (Ultracentrifugation)
- Maximum RPM: 40,000 rpm
- Max g-Force: 285,000.00
- k-Factor: 137
- Number of Tubes: 6×14 mL / 14×95 mm(6×14 mL / 1×4 in)

£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter SW 41 TI 41,000 RPM Swinging Bucket Rotor Lab
ITEM-48416
Beckman Coulter SW 41 TI 41,000 RPM Swinging Bucket Rotor Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and remains untested.
Specifications;
- Rotor Type Ultra – Swinging Bucket
- Maximum Speed 41,000 rpm
- Maximum RCF at r max (g) 288,000 x g
- k-Factor 124
- Rotor Material Titanium
- Bucket Material Titanium, Anodized Aluminum Cap

£ 500.00 (ex. VAT) 1 in stock
Bio-Rad UltraMark Microplate Imaging System
ITEM-45008
Bio-Rad UltraMark Microplate Imaging System
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in fair cosmetic condition.
No controller or additional equipment included to adjust the temperature.
Model: Ultramark.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter Optima TLX Ultracentrifuge 120,000rpm Lab Spares/Repairs
ITEM-34798
Beckman Coulter Optima TLX Ultracentrifuge 120,000rpm
This was removed from a university lab where it was surplus to requirements.
The unit powers up but half of the keypad no longer works. It is sold for spares/repairs.

£ 500.00 (ex. VAT) 1 in stock
LEEC Research CO2 Incubator Model GA2000 Lab
ITEM-41593
LEEC Research CO2 Incubator Model-GA2000
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in reasonably good cosmetic condition.

£ 500.00 (ex. VAT) 1 in stock
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories Lab
ITEM-24618
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories
This was removed from a university lab where it was surplus to requirements.
The system consists of;
1 x Echo HiVol Hi Volume Sampler
Model, Echo Hi Vol
110V
The unit powers on and is in good cosmetic condition. It was powered on by our Step down from the mains supply (not included).
The buttons seem a little slow to respond and there are some tape marks and scuffs and scratches around the unit from general use. The unit is lockable but no key is supplied. The key is included.
1 x Delta Wireless Sampler
Electronic Flow Sampler w/ Battery pack
Model Delta
110V
The unit powers on and is in good cosmetic condition. We did not charge Battery to test, as we used our Step down from the mains supply. (not included).
1 x Delta Battery pack
The unit is in good cosmetic condition. It was not tested.
2 x Flight Casea
3x Marigold gloves (size 9)
1x Spanner (size 10)
2x fuses T6.3AL 250V
4X keys
1x Widget H045
1x TCR Fine PM Air Inlet PM 2.5 200l/min
1x Metal Filter attachment
2x Glass chambers
1x Metal Dome
3x Sanitising spray
2x TCR TECORA plastic sample trays (3cm diameter)
6x Sample dishes with lids (14cm diameter)
4x Glass condensers 1x opened 3x factory sealed
1x Delta quick guide
2x Boxes of Microfibre Discs (1x opened 102mm Dia) quantity unknown
(1x sealed 100 Dia) quantity 100
1x Flurescein Green Concentrate (bottle partially full, sealed inside a bag it has leaked at some point.
1x Air pollution monitoring equipment (Metal chamber with hose)
1 x manual
1 x TCR Tecora TCR Downloader for Echo Series, Delta & Bravo Plus.
There is also a software disk included with this but it is entirely in Italian.

£ 500.00 (ex. VAT) 1 in stock
Soxtec Avanti 2050 Auto Fat Extraction System with Drive Unit Lab
ITEM-24537
This Soxtec Avanti 2050 Auto Fat Extraction System was removed from a university lab where it was surplus to requirements.
Included are;
1 x Foss Tecator 2050 Soxtec Avanti Auto Extraction Unit
Part no. 10007330
1 x Foss Tecator 2050 Drive Unit
Part no. 10007338
The item powers on with the drive unit supplying power and controlling the extraction unit. It was not tested further. It seems to be missing a control unit.
The item is in reasonably good cosmetic condition with some marks from use.

£ 500.00 (ex. VAT) 1 in stock
Nikon Microphot-FXA Fluorescence Microscope with HP-10101AF PSU & 4 x Objectives
ITEM-24299
This Nikon Microphot-FXA Fluorescence Microscope was removed from a university lab where it was surplus to requirements.
The PSU is missing so we were unable to power up the Microscope. It requires a Nikon PSM-4A. The power supply unit for the mercury lamp is present. The PSU is working but the bulb needs to be replaced.
The system is in reasonably good cosmetic condition with marks from use.
It has;
2x Nikon FX-350X 35mm film cameras attached via Nikon mounts.
1 x SOFT RTS 25.4 2mp slider with data lead.
1 x NIKON 4/0.10
1 x NIKON FLUOR 20 0.75 160/0.17
1 x NIKON FLUOR 40 0.85 160/0.11-0.23
1 x NIKON FLUOR 100 / 1.30 OIL 160/0.17
2 x CFWN D10 X/20
There is a PC with ISMOL Software & relevant PCI cards for connecting everything.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Tuttnauer 5050 ELV-D 110L Laboratory Autoclave Spares/Repair
ITEM-08317
Tuttnauer 5050 ELV-D 110L Laboratory Autoclave Spares/Repair
This item was removed from a university where it was surplus to requirement.
This item is in poor cosmetic condition and is sold as Spares/Repair.
The lid of the item is not fixed, and the internal pump has been removed.

£ 500.00 (ex. VAT) 1 in stock
TQ TD1050 Steam Engine Trainer Teaching Rig Apparatus Lab
ITEM-31869
TQ TD1050 Steam Engine Trainer Teaching Apparatus Rig
This was removed from a university lab where it was surplus to requirements.
It is in full working order.
Included are;
TD1050 General Assembly
TQ165554-001
TD1050 - DTS2 Torque/Speed Display Unit
TQ160508-001
TD1050-DT1 Temperature Display
TQ165554-001
VDAS-F - VDAS Frame Mounted Version
TQ156326-009
Grosvenor Pump
Model - 5583
SN - 21278
Dynatherm Part no. 42673
SN - 13107-1

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Fujifilm FLA-3000R Fluorescent Image Analyzer Spares/Repairs
ITEM-30522
This was removed from a university lab where it was surplus to requirements.
The unit powers up but a warning light flashes. It was not tested further.
It is sold for spares/repairs

£ 500.00 (ex. VAT) 1 in stock
Varian TV 81-T Turbo Turbomolecular Pump Model 9698905M001 Lab
ITEM-30514
This Varian TV 81-T Turbo Turbomolecular Pump Model 9698905M001 was removed from a university lab where it was surplus to requirements.
The pump has been tested with a controller (not included) and is in working order, but has not been tested under a vacuum.
It is in good cosmetic condition with minor marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System Spares/Repairs
ITEM-30328
This GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System was removed from a university lab where it was surplus to requirements.
The microscope focus motor/Z-Drive has been removed from this unit.
We have removed the microscope focus motor/Z-Drive from this system. It is sold for spares/repairs.
Included in the system are;
1x GE IN Cell Analyzer 1000:
Dims: L85cm W70cm H70cm
The unit is in good cosmetic condition.
When connected up to the power supply we could not hear the unit power on.
Inside the unit it appears have been tampered with as there are several cables and connector cables not attached to anything the EARTH cable is also not attached. A circuit board has been removed from the unit. this may explain why we could not get the unit powered up.
1x GE IN Cell Analyser 1000 Kinetic OZ Enabled
Model No. 28-4051-29
System No. 1316043
The unit powers on and is in good cosmetic condition.
The fans are working, they can be heard powering up immediately once the unit is powered on.
1x GE IN Cell Analyser 1000 ENDPNT OZ Enabled
Model No. 28-4051-28
System No. 1358008
The unit powers on and is in good cosmetic condition. The unit appears to have been stripped only 1x HP Workstation 6200 PC and 1x MVP Series power supply were still inside it.
The Kinetic OZ Enabled unit appears to be complete with an Optigrid light imaging system. We have fitted the GE IN Cell Power supply back into the rack unit where it should be housed.
EMKA Keys:
Model 2233X
2x keys for GE IN Cell Analyser 1000 ENDPNT OZ Enabled
2x keys for the GE IN Cell Analyser Kinetic OZ Enabled
All 4 keys are in good cosmetic condition and open and lock both the Kinetic and the ENDPNT units.
We did not connect up the GE IN Cell 1000 to the GE 1000 Kinetic OZ Enabled unit as one of the communication cable connections at the back of the rack has come away and will need to be fixed back on. Without this being fixed we do not believe the systems to be aware of each other.
1x Optigrid Light Imaging System:
Model QIOPTIQ
The unit powers on and is in good cosmetic condition.
1x Xenon ARC Lamp Power supply w 2x keys:
Type 6
Part No. 56409187
The unit powers on and is in good cosmetic condition. The keys do not fit in the barrel well and do not turn. The LCD screen is working and reads clearly.
Keys:
model No. 901
The units are in good cosmetic condition
2x MVP Series Power supplies. ( 1x in each rack unit)
Model Nos. MP8-3Q-1L-00
Both units power on and are in good cosmetic condition. There is dust around and on both units from general use.
1x Hamilton power supply
Model No. 231352/00
The unit powered on and is in good cosmetic condition.
2x APC rack PDU
The units power on and are in good cosmetic condition.
1x GE cO2 Controller:
Ser No. 1352436
The unit powers on and is in good cosmetic condition. The LCD screen is working and reads clearly. All dials and switches appear responsive to the unit.
2x Hewlett Packard PC's: HP workstation xw6200:
The units both power on and are in good cosmetic condition.
There is some dust around the units from general use.
Programs on PC:
•Overlord 2
Version 2.1.0.0
•IN Cell Analyser 1000 3.5
•IN Cell Analyser 1000 3.6
The program is password protected and we could not get past this window to access other parts of the program.
'Shutter Counter 1984048'.
3 x Low Voltage Computer Cables:
•28-4060-63 Umbellcal Axis 0734
•28-4060-66 0647
•28-4060-68 Umbellcal Hamilton 0738
1x Xenon lamp Bulb:
Model OSRAM XBO 100W OFR
The box had been opened. We cannot confirm if this lamp has been used. The unit was in good cosmetic condition.

£ 500.00 (ex. VAT) 1 in stock
Bright Model M3500 Rotary Microtome Lab
ITEM-29829
This Bright Model M3500 Rotary Microtome was removed from a university lab where it was surplus to requirements.
The unit powers up with 2 x AA batteries (not included) and is in good working order mechanically, but has not been tested on samples.
It is in very good cosmetic condition with only minor marks from use.

£ 500.00 (ex. VAT) 1 in stock
PSL Rheotek TCB 8 Temperature Controlled Water Viscometer Bath Lab
ITEM-28205
PSL Rheotek TCB 8 Temperature Controlled Viscometer Bath
This was removed from a university lab where it was surplus to requirements.
The unit powers up and the heating is in good working order.
Inside tank dimensions - L59 W31 H37cm
It is in good cosmetic condition with some marks from use.

£ 500.00 (ex. VAT) 1 in stock
GT 55 Liquid Nitrogen Dewar with 6 x Storage Racks Lab
ITEM-25464
This GT 55 Liquid Nitrogen Dewar with 6 x Storage Racks was removed from a university lab where it was surplus to requirements.
The unit is in reasonable cosmetic condition with some marks from use. It has not been tested.
There are 6 Racks inside with drawers that hold 5ml tubes.

£ 500.00 (ex. VAT) 1 in stock
AT Delta-T Logger System with Software & Accessories Lab
ITEM-25021
This was removed from a university lab where it was surplus to requirements.
The system is in reasonable cosmetic condition. There are stains and other marks along the edges and surface. The atmospheric temperature & humidity probe is dented.
The item is untested as it wasn't supplied with a PSU.
Also included are the following:
1x Delta-T Devices atmospheric temperature & humidity probe
S/N: RHAI-077
1x Delta-T PC software type LS2
Version 1.04
1x Desiccant Pack
1x DE-9 cable
1x Tutorial Kit
1x Spares & Accessory Pack
3x Component part (EMC directive) 5m
5x Temperature Probes User Manual
1x Quantum Sensor User Manual
1x Delta-T Devices Data Loggers, Sensors & Systems
1x Delta-T Devices Plant Science & Solar Radiation Studies
1x Delta-T Devices Image Analysis Systems
1x Delta-T Logger User Manual Version 2.01

£ 500.00 (ex. VAT) 1 in stock
Irori AccuTag 100 Scanning Station Model: At-100-CS-CE Lab
ITEM-24838
This Irori AccuTag 100 Scanning Station Model: At-100-CS-CE was removed from a university lab where it was surplus to requirements.
The item is in reasonable cosmetic condition. There are scratches/dents on the surface, along with stains. The accessories have been used and thus have broken seals.
The item was plugged in, but there wasn't any clear indication it had powered on. We were unable to test it further without a PC connection.
Also included are the following:
1x AccuTag Synthesis Manager Version 1.0
1x AccuTag Synthesis Manager Version 2.26
12x Irori Radio Frequency Tag
1x PSU
1x DE-9 cable

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Integrated BMS Jet Nozzle Test Facility -CP3 Lab Spares/Repairs
ITEM-41471
Integrated BMS Jet Nozzle Test Facility -CP3 Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to power it on or test it further at our facility. The unit has no power cable.
Therefore, it is listed as Spares/Repair.
Includes operation keys.
Door key not included but can be opened with a standard control cabinet key.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller Spares/Repair Lab
ITEM-47102
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller
This item was removed from a university laboratory where it was surplus to requirements.
The item is in reasonably good cosmetic condition; however, it cannot be powered on due to the absence of a plug and a split in the flex exposing the internal wires.
It is therefore sold as spares or repair.
Includes:
- Carl Zeiss Surgical Microscope
- Metz NAG 80 VA Controller

£ 500.00 (ex. VAT) 1 in stock
VWR LA 214 Laboratory Balance
ITEM-49530
VWR LA 214 Laboratory Balance
This item is sold on behalf of a client where it is surplus to requirements.
This item has a max capacity of 220 g with a readability of 4 decimal places. It was serviced: 05/09/2024.
It is in perfectly good condition and working order, with no significant cosmetic defects. The balance was in use in an industry laboratory up until June 2025 and was removed during a lab shutdown.
The item comes with the power cable.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Milestone Ethos plus 2 SEL Microwave Solvent Extraction Labstation Spares/Repair
ITEM-41135
Milestone Ethos plus 2 Microwave Solvent Extraction Labstation
This system was removed from a university where it was surplus to requirement.
All units are in good cosmetic condition, with the primary unit (Milestone Ethos plus 2) and PC Set-Up turning on, however, there is no power in the LabTerminal 800 Controller.
The system is sold for spares/repairs.
-1x Milestone Microwave Laboratory Systems LabTerminal 800 Controller
1x easywave chip card for the controller
S/N- 0205722
-2x Rotor' for microwave
- Relevant vessels and safety shields for rotors
-2x ATC-FO sensors for microwave
-2x Torque wrenches for rotor
-2x Extraction Pipes
1x Monitor (IIyama Prolite B2206WS) and Dell Tower Optiplex GX620
Includes: Pipette tracker v3.3 Software

£ 500.00 (ex. VAT) 1 in stock
Sanyo MDF-U730M Biomedical Freezer Lab
ITEM-44673
Sanyo MDF-U730M Biomedical Freezer Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in good cosmetic condition.
Includes:
6 x Shelves - 62 x 62 cm
14 x Containers - 62 x 31 x 16 cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Whatman/Parker Balston UHP Nitrogen Generator Model 76-94-220 - Spares/Repair
ITEM-46647
Whatman/Parker Balston UHP Nitrogen Generator Model 76-94-220
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, the previous owner has stated it is not in working order.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
GEM Indirect Calorimeter ISGEM319 Spares/Repair Lab
ITEM-46579
GEM Indirect Calorimeter ISGEM319 Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonable cosmetic condition. The casing is loose and required securing with a screw, suggesting it may have been opened previously.
The item powers on, but no further testing has been conducted. The previous owner reported it as non-functional, though the specific fault is unknown.
Therefore, it is listed as Spares/Repair.
Includes:
- Pipe fittings
- Grey connector box for the pipe system

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
YSI 2300 230V STAT Plus Glucose Lactate Analyser Spares/Repair Lab
ITEM-46578
YSI 2300 230V STAT Plus Glucose Lactate Analyser Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It powers on and is in reasonably good cosmetic condition, however, there is a missing side panel.
The previous owner had stated it is not in working order, though the reason is unknown.
Therefore, it is listed as Spares/Repair.

£ 500.00 (ex. VAT) 1 in stock
Leitz Laborlux S Microscope Type 020-505.030 w/ 3 x Objectives 10/40/100x
ITEM-47270
Leitz Laborlux S Microscope Type 020-505.030
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and in good working order.
Includes:
- 2 x Leica Periplan 10x / 18 Eyepieces (519 750)
Objectives:
- 160/- EF 10/0.25 (519760)
- *160/0.17 PL FLUOTAR 100/1.32 OIL (519847)
- 160/0.17 EF 40/0.65 (519762)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Link Analytical eXL Model 1100-012 X-Ray Imaging & Analysis System Spares/Repair
ITEM-46803
Link Analytical eXL Model 1100-012 System
This system was removed from a university laboratory where it was surplus to requirements.
The main eXL unit initially powered on, supplied power to the monitor, and displayed startup errors (see photos), but the keyboard and mouse were unresponsive. Upon restarting, the monitor and indicator lights did not power up, although internal computer activity could still be heard. Further attempts to power cycle the system were unsuccessful.
Therefore, this system is listed as Spares/Repair.
It is in good overall cosmetic condition.
The system comprises the following:
- Link Analytical eXL
- Model: 1100-012
- Serial No.: 2917
- Link Analytical Monitor
- Model: CLR 1401
- Serial No.: 2665
- Link Analytical Keyboard
- Model: 1487
- Serial No.: 2763
- Link Analytical Mouse and Mouse Mat
- Link Analytical Printer (Epson LQ-500)
- Model: P78PA
- Serial No.: T0011258
- *Note: Printer would fail PAT due to a missing rear cover
- (Box of printer paper included)
Included Manuals:
- Link Analytical eXL System Service Manual
- Link Analytical Disk, Tape & File Sequel, Sequences, Display & Hard Copy, Genie, Video Frame Grabber
- Link Analytical Getting Started – X-Ray Analyser, System Manager, RTS-2/FLS, Auto
- Link Analytical Computer System & Electron Diffraction Pattern Analysis
- Link Analytical Analysis & Imaging
- Link Analytical Quantitative Mapping Operators Manual
Accessories and Additional Parts:
- Box of 10 floppy disks
- Labelled black 'X-Ray' cables and a grey monitor cable (collected as connected)
- 2 x Tracor Northern IPP Series II X-Ray Analyzer Operator Manuals
- 3 x Digital software disks (in blue cases – large format)
- GEMS Sensor – P/N 197093-RS (white)
- Unidentified round metal part
- Boxed metal piece labelled "Scintillator" (assy – ME 0084)
- Metal part tagged "X-Ray Source XA2-57"
- Metal part with Watec WAT-902B CCD Camera and:
- Objective lens: M Plan APO 10 SB 0.23 ∞/0 SLWD 39
- Metal piece with part number AG61-113 etched at the base
- Orange cable marked "AML J011 034"
- Black light source
- Various other cables (not compatible with the eXL)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf 5810R BenchTop Centrifuge Spares/Repair Lab
ITEM-46918
Eppendorf 5810R BenchTop Centrifuge
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and powers on.
During testing, it failed to reach its maximum specified temperature of 40ºC.
Due to these issues stated above, this centrifuge is being sold as spares or repairs.

£ 500.00 (ex. VAT) 1 in stock
Narishige Model-M0-203, MMW-23 Micromanipulator Parts Lab
ITEM-45198
Narishige Model-M0-203, Model-MMW-23, and Parts
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition; however, we are unable to test the functionality of the units.
Included Models and Serial Numbers:
- Narishige Model M0-203
Serial No.: 9306078
- Narishige Model MMW-23
Serial No.: 96003

£ 500.00 (ex. VAT) 1 in stock
Workplace Modular Systems Laboratory Benchtop Cabinet 100 x 70 x 83 Lab
ITEM-46585
Workplace Modular Systems Laboratory Benchtop Cabinet 100 x 70 x 83 Lab
This item was removed from a facility where it was surplus to requirement.
It is in good used cosmetic condition. The cabinet includes removable side panels and a single internal drawer with dimensions of approximately 51cm (L) x 34cm (W) x 11cm (D).

£ 500.00 (ex. VAT) 1 in stock
Workplace Modular Systems Laboratory Benchtop Cabinet 100 x 70 x 83cm
ITEM-46583
Workplace Modular Systems Laboratory Benchtop Cabinet 100 x 70 x 83cm
This item was removed from a facility where it was surplus to requirements.
It is in good used cosmetic condition. The cabinet includes removable side panels and a single internal drawer with dimensions of approximately 51cm (L) x 34cm (W) x 11cm (D).

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Mixed Job Lot of Laboratory Equipment - Edwards, Sorvall, Prior, New Brunswick
ITEM-46866
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
- Sorvall HB-6 Swinging-Bucket Centrifuge Rotor 6 x 50ml P/N 11850 Lab
- DACS 8 Channel (Eightch) Volume Controller
- Lebow Assoc. Inc Load Cell Model no. 3132 2000lbs Lab
- AID EliSpot FluoroSpot Reader System Model ELR02 Lab
- AID EliSpot FluoroSpot Reader System HR Lab
- FluidX XTR-96 96 Tube Rack Scanner & Software Lab
- GLO Low-Speed Benchtop Laboratory Centrifuge GLO-GT416 with 270rcf Rotor Lab
- NPI Stimulus Isolation Unit Version - ISO-STIM 01D Lab
- ZEISS ECU Modular Microscope Controller - Power-IF, HPSC1, S/C-IF
- Berthold Technologies Lumat LB 9507 Tube Luminometer Lab
- Severn Analytical SA 6500 UV/VIS Absorbance Detector Lab
- Prior England Epic MEL 1 Micromanipulator Lab
- New Brunswick Scientific Model G-2 Gyrotory Laboratory Shaker Lab
- Thermo Scientific Cellject Duo Electroporator HCJD0137 Lab Spares/Repairs
- X2 ErgoOne® FAST Pipette ControllerS
- Integra PipetBoy
- Integra Vacusafe (158 3XX) With 1 x Integra Vacuboy Pipette
- Elga Purelab Ultra Genetic MK2 Benchtop Water Purifier Lab
- Hewlett Packard 16700A Logic Analysis System
- Hellma Semi-Micro Cuvettes, 104-QS, 10 mm Layer Thickness
- MJ Research PTC-225 Pelter Thermal Cycler PCR DNA Unit
- Edwards 2 Two Stage Pump Lab Spares/Repairs
- UniFlows Degasys DG-2410 Degasser
- Megger PAT Tester Model 32 Lab
- Heraeus 3336 Rotor
- Unknown Furnace
- Mettler Toledo PB3002 1DP Balance Lab
- Gould 20Ms/Sec 20 MHz Oscilloscope (DSO) 1604 Lab
- Ernst Leitz Wetzlar 307-143.004

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Scientific ULT Freezer Model-U725 -86 Spares/Repair Lab
ITEM-46517
New Brunswick Scientific ULT Freezer Model-U725 -86 Spares/Repair Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing it did not drop in temperature.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Liebherr GKPv 6522 Glass Fronted Fridge - Spares/Repair Lab
ITEM-46622
Liebherr GKPv 6522 Glass Fronted Fridge - Spares/Repair Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, during testing it failed to cool beyond 13ºc when set to 1ºc.
Therefore, it is listed as Spares/Repair.
Items 1751 to 1800 of 2573