All Products
Items 1951 to 2000 of 2586

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
CI Electronics Sade P2 Checkweigher Weight Sorter Spares/Repair
ITEM-46233
C1 Electronics Sade-P2 Automatic Tablet CheckWeigher
This item was removed from a university laboratory where it was surplus to requirements.
It powers on but displays a “Zero Failure” message immediately upon startup, accompanied by an alarm. This message cannot be cleared, and the unit cannot proceed to operation.
Therefore, it is listed as Spares/Repair.
It is in reasonably good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eurotherm Process Automation System with TCS Tactician T1000 & Components
ITEM-24653
Eurotherm Process Automation System with TCS Tactician T1000 & Components
This was removed from a university lab where it was surplus to requirements.
The unit is in reasonable cosmetic condition though the access panel of the switchboard has snapped all its hinges. These will need replacing to secure the unit.
We were unable to power the unit or the TCS Tactician T1000 Controller It was not tested further. The cabinet is filled with electrical components.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Dynamic Gastric Model (DGM) Custom Made Model Lab Spares/Repairs
ITEM-46358
Dynamic Gastric Custom Made Model
This item was removed from a university lab where it was surplus to requirements.
This custom-made Dynamic Gastric Model exhibits poor cosmetic condition. It cannot be powered on or tested due to a visual PAT failure and exposed wiring.
The Dynamic Gastric Model (DGM) is a bench-top computer controlled in vitro system that simulates digestion in the human stomach. DGM allows accurate prediction and understanding of the behaviour of foods or drug preparations within the human gut during digestion in real time.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Brema Laboratory Ice Flaker Machine Model - GB 1555 A Spares/Repair Lab
ITEM-28134
Brema Laboratory Ice Flaker Machine Model GB 1555 A
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition. However, it is leaking water due to a broken junction in the overflow-to-waste pipe.
As a result, it is listed as spares or repair.
Please note: This item was previously used in a laboratory setting and is not suitable for use in commercial catering. It should be used for laboratory purposes only.
Includes:
- Operating manual
Internal dimensions: D46.5 × W67.5 × H57 cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Typhoon Trio+ Variable Mode Imager Spares/Repair Lab
ITEM-37335
Typhoon Trio+ Variable Mode Imager
This item was removed from a university lab where it was surplus to requirement.
It has not been tested due to exposed wiring, and is sold as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Aeromatic Fielder MP-Micro Fluid Bed Dryer Spares/Repair Lab
ITEM-39838
Aeromatic Fielder MP-Micro Fluid Bed Dryer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on.
Therefore, we are unable to test it further at our facility, and it's listed as Spares/Repair.
The item also contains various Assembling Dryer/ Top Sprayer Containers and cables, as seen at the end of the slide.
Specifications;
- Model: MP-MICRO
- Serial#: 04012
- Date: FEB 04

£ 500.00 (ex. VAT) 1 in stock
Synbiosis aCOLyte 3 Colony Counter 8000/SYN Lab
ITEM-35291
This Synbiosis aCOLyte 3 Colony Counter was removed from a university lab where it was surplus to requirements.
This unit powers up with a 12V DC power adapter (not included). The device runs through the 3 different start-up stages but has not been tested further.
It is in good cosmetic condition with marks from use.

£ 500.00 (ex. VAT) 1 in stock
Windley Bros Heavy Duty Isolation Anti Vibration Table
ITEM-42830
Windley Bros Heavy Duty Isolation Anti Vibration Table
This item was removed from a university lab where it was surplus to requirements.
It is in reasonably poor cosmetic condition with surface rust present. We are unable to test it at our facility.
This anti-vibration table is constructed from cast iron and steel. The frame comprises angle iron legs with steel bar bracing, supporting a cast iron base.
Working height: 93cm.
Solid steel tabletop: 102 x 76 x 1.2cm

£ 500.00 (ex. VAT) 1 in stock
Wykeham Farrance Oedometer CBR Testing Lab
ITEM-34568
This Wykeham Farrance Oedometer CBR Testing was removed from a university lab where it was surplus to requirements.
The unit powers up the hand control unit works correctly, and the hydraulic ram goes up and down freely.
It is in reasonable cosmetic condition with marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Innova Type 4330 Incubator Shaker Lab
ITEM-40993
This New Brunswick Innova Type 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.
The unit powers up and heats, but does not cool or shake.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Innova 4330 Incubator Shaker Lab Spares/Repairs
ITEM-40991
This New Brunswick Innova 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.
The unit powers up but does not shake. The heating and cooling functions work.
It is in reasonably good cosmetic condition with minor marks.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Innova Model 4330 Incubator Shaker Lab Spares/Repairs
ITEM-40992
New Brunswick Innova Model 4330 Incubator
This was removed from a university lab where it was surplus to requirements.
The unit heats but does not cool. The shaking works, but requires maintenance.
It is sold for spares/repairs.

£ POA 1 in stock
VG Scientific Wien Mass Filter for Ion Beam Filtering UHV Lab
ITEM-19542
This item is new in stock. Please enquire for further details.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Xenogen Ivis 100 Imaging System Microscope - XGI-8, XRH-2 Lab
ITEM-29746
Xenogen Ivis 100 Imaging System Microscope - XGI-8, XRH-2 Lab
This system was removed from a university lab where it was surplus to requirements.
We have powered everything up and the system is in good cosmetic condition with marks from use.
The lab informed us that it has not been used for several years but was in working order when last used. The calibrated light source has now been removed so we are now selling for spares/repairs.
Included as part of the Ivis 100 are;
1 x IGC Polycold Systems Inc, Cryotiger Compressor.
1 x Spectral Instruments Inc, 600 Series CCD Camera Controller.
1 x Spectral Instruments Inc, Refrigeration Line Heater.
1 x Xenogen Corporation, XGI-8 gas Anesthesia System.
1 x DELL PC & Monitor, Running Windows 2000 Professional.
Instruction Manuals & Xenogen Living Image Version 2.20 Discs included.
Instruction Manuals & Xenogen Living Image Version 2.20 Discs included.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Scientific Innova CO-170 Lab Spares/Repairs
ITEM-40039
New Brunswick Scientific Innova CO-170 Lab
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in fairly poor cosmetic condition with some rust, it has been temperature-tested. (thermometer not included)
The unit developed a back-light fault in the screen during CO2 testing. It is sold as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf 5810R BenchTop Centrifuge Spares/Repair Lab
ITEM-46918
Eppendorf 5810R BenchTop Centrifuge
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and powers on.
During testing, it failed to reach its maximum specified temperature of 40ºC.
Due to these issues stated above, this centrifuge is being sold as spares or repairs.

£ 500.00 (ex. VAT) 1 in stock
VWR PCR Plate Centrifuge II Lab
ITEM-49516
VWR PCR Plate Centrifuge II Lab
This item is sold on behalf of a client where it is surplus to requirements.
This item is in complete working order, and in good cosmetic condition.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

£ 500.00 (ex. VAT) 1 in stock
Ohaus Frontier Micro Centrifuge FC5513 Lab
ITEM-49518
Ohaus Frontier Micro Centrifuge FC5513 Lab
This item is sold on behalf of a client where it is surplus to requirements.
This item is in complete working order, and in good cosmetic condition.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

£ 500.00 (ex. VAT) 1 in stock
Grant FH15 Flow Heater and FC20 Flow Cooler Lab
ITEM-42784
Grant FH15 Flow Heater and FC20 Flow Cooler
This system was removed from a university laboratory where it was surplus to requirements.
The FH15 Flow Heater powered on with the pump running. The heater light illuminated when the set temperature was increased above ambient.
The FC20 Flow Cooler powered on, and both the compressor and fan could be heard operating.
These units do not include a built-in tank and require an external header tank to function as part of a complete system. Due to this, full-range temperature testing was not performed.
It is in good cosmetic condition.
Includes:
- Grant FH15 Flow Heater (Serial No. 72311)
- Grant FC20 Flow Cooler (Serial No. 72311)
- Model: FH15 / FC20
- Serial No.: 72311

£ 500.00 (ex. VAT) 1 in stock
Cavey Laboratory Engineering McIlwain Tissue Chopper Model MTC/2E No Blade
ITEM-42796
Cavey Laboratory Engineering McIlwain Tissue Chopper Model MTC/2E
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, powers on and is in good mechanical order. We are unable to test it further at our facility.
Please note; There is no blade present on the cutting arm.

£ 500.00 (ex. VAT) 1 in stock
VWR LA 214 Laboratory Balance
ITEM-49530
VWR LA 214 Laboratory Balance
This item is sold on behalf of a client where it is surplus to requirements.
This item has a max capacity of 220 g with a readability of 4 decimal places. It was serviced: 05/09/2024.
It is in perfectly good condition and working order, with no significant cosmetic defects. The balance was in use in an industry laboratory up until June 2025 and was removed during a lab shutdown.
The item comes with the power cable.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Agilent 2100 G2939A Bioanalyzer System & DNA Chips Spares/Repair Lab
ITEM-48419
Agilent 2100 G2939A Bioanalyzer System & Accessories Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and powers on, however it could not be fully tested as two channels show high leakage currents.
Therefore, it is being sold as spares or repair.
Includes:
- 1 box x High Sensitivity DNA Chips (5 in box) – expires Jan 2026
- 1 box x High Sensitivity DNA Chips (10 in box) – expires Jan 2026
- 1 box x Electrode Cleaners (5 in box)
- 1 box x Chip Priming Station
- 1 x Bayonet Electrode Cartridge (in blue case)
- 1 box x 11 Syringe Kits
- 1 box containing Test Chip Kit/Electrode/Diode Test Chip & USB 2.0 Cable
Model: 2100 Bioanalyzer
Serial No.: DE13805731
Product No.: G2938C

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller Spares/Repair Lab
ITEM-47102
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller
This item was removed from a university laboratory where it was surplus to requirements.
The item is in reasonably good cosmetic condition; however, it cannot be powered on due to the absence of a plug and a split in the flex exposing the internal wires.
It is therefore sold as spares or repair.
Includes:
- Carl Zeiss Surgical Microscope
- Metz NAG 80 VA Controller

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Integrated BMS Jet Nozzle Test Facility -CP3 Lab Spares/Repairs
ITEM-41471
Integrated BMS Jet Nozzle Test Facility -CP3 Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to power it on or test it further at our facility. The unit has no power cable.
Therefore, it is listed as Spares/Repair.
Includes operation keys.
Door key not included but can be opened with a standard control cabinet key.

£ 500.00 (ex. VAT) 1 in stock
Irori AccuTag 100 Scanning Station Model: At-100-CS-CE Lab
ITEM-24838
This Irori AccuTag 100 Scanning Station Model: At-100-CS-CE was removed from a university lab where it was surplus to requirements.
The item is in reasonable cosmetic condition. There are scratches/dents on the surface, along with stains. The accessories have been used and thus have broken seals.
The item was plugged in, but there wasn't any clear indication it had powered on. We were unable to test it further without a PC connection.
Also included are the following:
1x AccuTag Synthesis Manager Version 1.0
1x AccuTag Synthesis Manager Version 2.26
12x Irori Radio Frequency Tag
1x PSU
1x DE-9 cable

£ 500.00 (ex. VAT) 1 in stock
GT 55 Liquid Nitrogen Dewar with 6 x Storage Racks Lab
ITEM-25464
This GT 55 Liquid Nitrogen Dewar with 6 x Storage Racks was removed from a university lab where it was surplus to requirements.
The unit is in reasonable cosmetic condition with some marks from use. It has not been tested.
There are 6 Racks inside with drawers that hold 5ml tubes.

£ 500.00 (ex. VAT) 1 in stock
AT Delta-T Logger System with Software & Accessories Lab
ITEM-25021
This was removed from a university lab where it was surplus to requirements.
The system is in reasonable cosmetic condition. There are stains and other marks along the edges and surface. The atmospheric temperature & humidity probe is dented.
The item is untested as it wasn't supplied with a PSU.
Also included are the following:
1x Delta-T Devices atmospheric temperature & humidity probe
S/N: RHAI-077
1x Delta-T PC software type LS2
Version 1.04
1x Desiccant Pack
1x DE-9 cable
1x Tutorial Kit
1x Spares & Accessory Pack
3x Component part (EMC directive) 5m
5x Temperature Probes User Manual
1x Quantum Sensor User Manual
1x Delta-T Devices Data Loggers, Sensors & Systems
1x Delta-T Devices Plant Science & Solar Radiation Studies
1x Delta-T Devices Image Analysis Systems
1x Delta-T Logger User Manual Version 2.01

£ 500.00 (ex. VAT) 1 in stock
PSL Rheotek TCB 8 Temperature Controlled Water Viscometer Bath Lab
ITEM-28205
PSL Rheotek TCB 8 Temperature Controlled Viscometer Bath
This was removed from a university lab where it was surplus to requirements.
The unit powers up and the heating is in good working order.
Inside tank dimensions - L59 W31 H37cm
It is in good cosmetic condition with some marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
WEG CFW -11 Venture Inverter Control Box Lab Spares/Repairs
ITEM-41470
WEG CFW -11 Venture Inverter Control Box Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to power it on or test it further at our facility.
The key is not included but can be opened with a standard control cabinet key.
Includes manual.
The unit has no cable so is sold for spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Julabo FL300 Recirculating Chiller - Spares/Repair Lab
ITEM-47581
Julabo FL300 Recirculating Chiller – Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
The unit shows minimal wear, with both of the top catches on the lid broken; this does not affect physical operation of the doors.
The cable is damaged, and the unit will not power on, so it is being sold for spares or repair.
Model: FL300

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Milestone Ethos plus 2 SEL Microwave Solvent Extraction Labstation Spares/Repair
ITEM-41135
Milestone Ethos plus 2 Microwave Solvent Extraction Labstation
This system was removed from a university where it was surplus to requirement.
All units are in good cosmetic condition, with the primary unit (Milestone Ethos plus 2) and PC Set-Up turning on, however, there is no power in the LabTerminal 800 Controller.
The system is sold for spares/repairs.
-1x Milestone Microwave Laboratory Systems LabTerminal 800 Controller
1x easywave chip card for the controller
S/N- 0205722
-2x Rotor' for microwave
- Relevant vessels and safety shields for rotors
-2x ATC-FO sensors for microwave
-2x Torque wrenches for rotor
-2x Extraction Pipes
1x Monitor (IIyama Prolite B2206WS) and Dell Tower Optiplex GX620
Includes: Pipette tracker v3.3 Software

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nikon Diaphot 300 Microscope *Condenser Removed* Lab Spares/Repairs
ITEM-39790
Nikon Diaphot 300 Microscope *Condenser Removed*
This microscope was removed from a university lab where it was surplus to requirements.
All mechanical elements are in good working order. The unit does not include the power supply or condenser therefore we are unable to perform any other tests. It is in good cosmetic condition with minor marks.
As stated in the title the condenser is not included.
It is made up of the following modules;
Nikon ND2 Filter
Nikon ND4 Filter
Nikon CFWN 10x/20 Eyepiece x 2
Nikon 100w Mercury Lamphouse LH-M100C-1
Nikon Halogen 12V 100W Microscope Lamp

£ 500.00 (ex. VAT) 1 in stock
Xerox Phaser 7400 Laser Printer With Ink Cartridges
ITEM-35876
Xerox Phaser 7400 Laser Printer With Ink Cartridges
This was removed from a university lab where it was surplus to requirements.
It powers up and is in good working order.
Includes 4 x ink cartridges:
-1 x Cyan (Imaging unit 108R00647)
-1 x Magenta (Imaging unit 108R00648)
-1 x Yellow (Imaging unit 108R00649)
-1 x Black (Imaging unit 108R00650)
Max prints per minute- 40
Model number- N31201B
Serial number- WNC757283

£ 500.00 (ex. VAT) 1 in stock
LEEC Research CO2 Incubator Model GA2000 Lab
ITEM-41593
LEEC Research CO2 Incubator Model-GA2000
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in reasonably good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter Optima TLX Ultracentrifuge 120,000rpm Lab Spares/Repairs
ITEM-34798
Beckman Coulter Optima TLX Ultracentrifuge 120,000rpm
This was removed from a university lab where it was surplus to requirements.
The unit powers up but half of the keypad no longer works. It is sold for spares/repairs.

£ 500.00 (ex. VAT) 1 in stock
Nikon Microphot-FXA Fluorescence Microscope with HP-10101AF PSU & 4 x Objectives
ITEM-24299
This Nikon Microphot-FXA Fluorescence Microscope was removed from a university lab where it was surplus to requirements.
The PSU is missing so we were unable to power up the Microscope. It requires a Nikon PSM-4A. The power supply unit for the mercury lamp is present. The PSU is working but the bulb needs to be replaced.
The system is in reasonably good cosmetic condition with marks from use.
It has;
2x Nikon FX-350X 35mm film cameras attached via Nikon mounts.
1 x SOFT RTS 25.4 2mp slider with data lead.
1 x NIKON 4/0.10
1 x NIKON FLUOR 20 0.75 160/0.17
1 x NIKON FLUOR 40 0.85 160/0.11-0.23
1 x NIKON FLUOR 100 / 1.30 OIL 160/0.17
2 x CFWN D10 X/20
There is a PC with ISMOL Software & relevant PCI cards for connecting everything.

£ 500.00 (ex. VAT) 1 in stock
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories Lab
ITEM-24618
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories
This was removed from a university lab where it was surplus to requirements.
The system consists of;
1 x Echo HiVol Hi Volume Sampler
Model, Echo Hi Vol
110V
The unit powers on and is in good cosmetic condition. It was powered on by our Step down from the mains supply (not included).
The buttons seem a little slow to respond and there are some tape marks and scuffs and scratches around the unit from general use. The unit is lockable but no key is supplied. The key is included.
1 x Delta Wireless Sampler
Electronic Flow Sampler w/ Battery pack
Model Delta
110V
The unit powers on and is in good cosmetic condition. We did not charge Battery to test, as we used our Step down from the mains supply. (not included).
1 x Delta Battery pack
The unit is in good cosmetic condition. It was not tested.
2 x Flight Casea
3x Marigold gloves (size 9)
1x Spanner (size 10)
2x fuses T6.3AL 250V
4X keys
1x Widget H045
1x TCR Fine PM Air Inlet PM 2.5 200l/min
1x Metal Filter attachment
2x Glass chambers
1x Metal Dome
3x Sanitising spray
2x TCR TECORA plastic sample trays (3cm diameter)
6x Sample dishes with lids (14cm diameter)
4x Glass condensers 1x opened 3x factory sealed
1x Delta quick guide
2x Boxes of Microfibre Discs (1x opened 102mm Dia) quantity unknown
(1x sealed 100 Dia) quantity 100
1x Flurescein Green Concentrate (bottle partially full, sealed inside a bag it has leaked at some point.
1x Air pollution monitoring equipment (Metal chamber with hose)
1 x manual
1 x TCR Tecora TCR Downloader for Echo Series, Delta & Bravo Plus.
There is also a software disk included with this but it is entirely in Italian.

£ 500.00 (ex. VAT) 1 in stock
Soxtec Avanti 2050 Auto Fat Extraction System with Drive Unit Lab
ITEM-24537
This Soxtec Avanti 2050 Auto Fat Extraction System was removed from a university lab where it was surplus to requirements.
Included are;
1 x Foss Tecator 2050 Soxtec Avanti Auto Extraction Unit
Part no. 10007330
1 x Foss Tecator 2050 Drive Unit
Part no. 10007338
The item powers on with the drive unit supplying power and controlling the extraction unit. It was not tested further. It seems to be missing a control unit.
The item is in reasonably good cosmetic condition with some marks from use.

RECERTIFIED ITEM
RECERTIFIED ITEM
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer Fusion Packard Microplate Reader Analyser A153601 lab
ITEM-04960
This Perkin Elmer Fusion Packard Microplate Reader Analyser A153601 was removed from a university lab where it was surplus to requirements.
The unit has been professionally serviced and is in working order outside. The PC does continually come up with a server busy message, and we have been unable to resolve that, but there is a workaround.
The instrument is functioning fine and can run samples smoothly.
Failed PMT Dark Count (Photon Counting) - Failed due to high thermal electron current in the PMT due to high voltage in this mode. This will not affect the functionality of the instrument.
Passed PMT Dark (Charge Integration) and LED Control.
Server Busy message - This action cannot be complete because the other program is busy. Choose ‘Switch to’ to activate the busy program and correct the problem.
It is in very good cosmetic condition with only minor marks from use.

£ 500.00 (ex. VAT) 1 in stock
Bright Model M3500 Rotary Microtome Lab
ITEM-29829
This Bright Model M3500 Rotary Microtome was removed from a university lab where it was surplus to requirements.
The unit powers up with 2 x AA batteries (not included) and is in good working order mechanically, but has not been tested on samples.
It is in very good cosmetic condition with only minor marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System Spares/Repairs
ITEM-30328
This GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System was removed from a university lab where it was surplus to requirements.
The microscope focus motor/Z-Drive has been removed from this unit.
We have removed the microscope focus motor/Z-Drive from this system. It is sold for spares/repairs.
Included in the system are;
1x GE IN Cell Analyzer 1000:
Dims: L85cm W70cm H70cm
The unit is in good cosmetic condition.
When connected up to the power supply we could not hear the unit power on.
Inside the unit it appears have been tampered with as there are several cables and connector cables not attached to anything the EARTH cable is also not attached. A circuit board has been removed from the unit. this may explain why we could not get the unit powered up.
1x GE IN Cell Analyser 1000 Kinetic OZ Enabled
Model No. 28-4051-29
System No. 1316043
The unit powers on and is in good cosmetic condition.
The fans are working, they can be heard powering up immediately once the unit is powered on.
1x GE IN Cell Analyser 1000 ENDPNT OZ Enabled
Model No. 28-4051-28
System No. 1358008
The unit powers on and is in good cosmetic condition. The unit appears to have been stripped only 1x HP Workstation 6200 PC and 1x MVP Series power supply were still inside it.
The Kinetic OZ Enabled unit appears to be complete with an Optigrid light imaging system. We have fitted the GE IN Cell Power supply back into the rack unit where it should be housed.
EMKA Keys:
Model 2233X
2x keys for GE IN Cell Analyser 1000 ENDPNT OZ Enabled
2x keys for the GE IN Cell Analyser Kinetic OZ Enabled
All 4 keys are in good cosmetic condition and open and lock both the Kinetic and the ENDPNT units.
We did not connect up the GE IN Cell 1000 to the GE 1000 Kinetic OZ Enabled unit as one of the communication cable connections at the back of the rack has come away and will need to be fixed back on. Without this being fixed we do not believe the systems to be aware of each other.
1x Optigrid Light Imaging System:
Model QIOPTIQ
The unit powers on and is in good cosmetic condition.
1x Xenon ARC Lamp Power supply w 2x keys:
Type 6
Part No. 56409187
The unit powers on and is in good cosmetic condition. The keys do not fit in the barrel well and do not turn. The LCD screen is working and reads clearly.
Keys:
model No. 901
The units are in good cosmetic condition
2x MVP Series Power supplies. ( 1x in each rack unit)
Model Nos. MP8-3Q-1L-00
Both units power on and are in good cosmetic condition. There is dust around and on both units from general use.
1x Hamilton power supply
Model No. 231352/00
The unit powered on and is in good cosmetic condition.
2x APC rack PDU
The units power on and are in good cosmetic condition.
1x GE cO2 Controller:
Ser No. 1352436
The unit powers on and is in good cosmetic condition. The LCD screen is working and reads clearly. All dials and switches appear responsive to the unit.
2x Hewlett Packard PC's: HP workstation xw6200:
The units both power on and are in good cosmetic condition.
There is some dust around the units from general use.
Programs on PC:
•Overlord 2
Version 2.1.0.0
•IN Cell Analyser 1000 3.5
•IN Cell Analyser 1000 3.6
The program is password protected and we could not get past this window to access other parts of the program.
'Shutter Counter 1984048'.
3 x Low Voltage Computer Cables:
•28-4060-63 Umbellcal Axis 0734
•28-4060-66 0647
•28-4060-68 Umbellcal Hamilton 0738
1x Xenon lamp Bulb:
Model OSRAM XBO 100W OFR
The box had been opened. We cannot confirm if this lamp has been used. The unit was in good cosmetic condition.

£ 500.00 (ex. VAT) 1 in stock
Varian TV 81-T Turbo Turbomolecular Pump Model 9698905M001 Lab
ITEM-30514
This Varian TV 81-T Turbo Turbomolecular Pump Model 9698905M001 was removed from a university lab where it was surplus to requirements.
The pump has been tested with a controller (not included) and is in working order, but has not been tested under a vacuum.
It is in good cosmetic condition with minor marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Fujifilm FLA-3000R Fluorescent Image Analyzer Spares/Repairs
ITEM-30522
This was removed from a university lab where it was surplus to requirements.
The unit powers up but a warning light flashes. It was not tested further.
It is sold for spares/repairs

£ 500.00 (ex. VAT) 1 in stock
TQ TD1050 Steam Engine Trainer Teaching Rig Apparatus Lab
ITEM-31869
TQ TD1050 Steam Engine Trainer Teaching Apparatus Rig
This was removed from a university lab where it was surplus to requirements.
It is in full working order.
Included are;
TD1050 General Assembly
TQ165554-001
TD1050 - DTS2 Torque/Speed Display Unit
TQ160508-001
TD1050-DT1 Temperature Display
TQ165554-001
VDAS-F - VDAS Frame Mounted Version
TQ156326-009
Grosvenor Pump
Model - 5583
SN - 21278
Dynatherm Part no. 42673
SN - 13107-1

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Tuttnauer 5050 ELV-D 110L Laboratory Autoclave Spares/Repair
ITEM-08317
Tuttnauer 5050 ELV-D 110L Laboratory Autoclave Spares/Repair
This item was removed from a university where it was surplus to requirement.
This item is in poor cosmetic condition and is sold as Spares/Repair.
The lid of the item is not fixed, and the internal pump has been removed.

£ 500.00 (ex. VAT) 1 in stock
Narishige Model-M0-203, MMW-23 Micromanipulator Parts Lab
ITEM-45198
Narishige Model-M0-203, Model-MMW-23, and Parts
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition; however, we are unable to test the functionality of the units.
Included Models and Serial Numbers:
- Narishige Model M0-203
Serial No.: 9306078
- Narishige Model MMW-23
Serial No.: 96003

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Job Lot of Mixed Benchtop Lab Equipment - IKA, Heraeus, Grant, Tehcne, Ohaus
ITEM-37231
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
ITEM-05085 Multi-PSU Blue Box *Unknown*
ITEM-05176 NUNC Labtop Cooler Cat: 355501 (-20 C) Scientific Laboratory
ITEM-05009 Oertling TP41 Top Pan Balance Scales
ITEM-04968 Stanton D40T Scales
ITEM-04596 Heraeus Instruments Biofuge Primo Centrifuge Damaged Lid
ITEM-10422 Brava Juice Blender
ITEM-05784 Techne Tecam TU-15 Tempunit Heater/Circulator
ITEM-05138 Microscope Handle/Stand
ITEM-03607 IKA Labortechnic hotplate and stirrer RCT Basic.
ITEM-10939 Unknown Medical Equipment
ITEM-05783 Grant Circulator Heater KA/TA for Laboratory Water Bath
ITEM-12684 Luckham Orbital Platform Shaker Rocker Mixing Lab
ITEM-14036 John Watts Type 586 Grinding Wheel Dressing Tool
ITEM-09555 Grant QBD2
ITEM-02500 Digital Data Formatting 53-150
ITEM-05479 Retro Smiths Manual Timer
ITEM-07327 Distron Geiger - Muller Counter Tube
ITEM-13055 Variomag Maxi Direct Magnetic Stirrer Lab Shaking Equipment
ITEM-08581 Digitron Model 3750TH
ITEM-14303 Ascom Digilarm Portable Digital Alarming Bell
ITEM-14189 PIFCO Vintage Electric Body Massager Personal Care
ITEM-07161 Techne Dri-Block DB-3 Dry Block Heater Laboratory Lab - Spares Repairs
ITEM-10765 Drummond Pipet-Aid Dual Pump Filtration Unit
ITEM-14032 Eclipse PS51 Piercing Saw Fixed Frame Other Tools
ITEM-09490 2 x IKA Big-squid Froggy stirrers
ITEM-13058 H.J.Latham Vintage Hair Dryer
ITEM-11722 JK KMO2 Electronics Magnetic Stirrer
ITEM-14312 Veho Discovery VMS-001 USB Microscope Stand
ITEM-13134 Pipette Stand
ITEM-12686 Grant Un-Stirred Water Bath Lab Heating Equipment
ITEM-04976 Stovall Life Science Belly Dancer
ITEM-11201 Barr & Stroud EL103 LF Power Supply
ITEM-14009 Wooden Box
ITEM-05088 PL4 Recorder JJ Instruments
ITEM-13622 1x Wesco Gren Oil Can 350cc Other Workshop Equipment
ITEM-13993 Wooden Box
ITEM-05222 Thermo Digital Series SpeedVac™ Systems Heat Laboratory Scientific *Lid Is Broke
ITEM-11091 Denley Orbital Mixer Lab Stirring Equyipment
ITEM-06569 Infrared Lamp Type HP3614
ITEM-04321 fisherbrand stirrer
ITEM-11032 4x Rank Bros 100 Electronic Stirrer Control Lab Shaking Equipment
ITEM-08321 Stuart Scientific SB1 Blood Tube Rotator
ITEM-11401 2x Anatune CF-100 Benchtop Laboratory Centrifuge Vortex Robotic
ITEM-10505 Race Pedal Joy Stick IT Equipment
ITEM-04287 Job lot of 3 blood glucose monitoring system
ITEM-08323 MULTI-JOB LOT 2 pipettes
ITEM-10657 Amazon.ca Salton Vacuum Bag Sealer
ITEM-03116 Job Lot of 4 x Faulty H R Flow Inducer MHRE 4 and MHRE 100
ITEM-06311 Corning PC-351 Hot Plate Stirrer Laboratory Heating Mixing - Spares Repairs
ITEM-11287 Harvard R150424 Thermo-Circulator Controller
ITEM-05971 Mettler Toledo PL3000 Laboratory Precision Digital Balance Scales
ITEM-10534 Fisher Scientific LABOSI Power 300 Electrophoresis Power Supply
ITEM-06534 Hybaid PS 250 Electrophoresis Power Supply
ITEM-06906 Ohaus Dial-O-Gram Balance 310g Capacity Scales
ITEM-10259 Unbranded Vintage Weighing Pan Balance
ITEM-02436 Selector Unit 1694 F
ITEM-12203 Electrothermal Cat. M106 Heating Mantle Lab Heating Equipment
ITEM-06006 Developing Health Technology Portable Haemoglobin Analyzer DHT Hb 523
ITEM-12290 Electrothermal EMO100 Heating Mantle Lab Heating Equipmet
ITEM-11905 Sarstedt M-Sarpette Manual Pipette With Gilson Distriman
ITEM-12663 Single Stage BS5741 Single Gauge Regulator
ITEM-06102 Thorn DFLD 400 Lamp
ITEM-12198 Electrothermal Heating Mantle Size 950ml Lab Heating Equipment
ITEM-12205 Electrothermal EM2000/CE MK5 Heating Mantle Lab Heating Equipment
ITEM-10537 Biolab pH & Conductivity Meter Lab Equipment
ITEM-06045 Reliance Electric Gast Vacuum Pump - Faulty
ITEM-12155 GallenKamp HotPlate Magneic Stirrer Cat.SWT-315
ITEM-09248 ChemLab SS3H Hotplate Laboratory Stirrer & Digitron Meter Spares Repairs
ITEM-12175 MK V Orbital Shaker [condition: Used]
ITEM-04703 Mettler P1210 Laboratory Scale 1200G Max d=10mg Tara 0-100g
ITEM-07117 JJ Instruments Chard Recorder (Spares & Repairs)
ITEM-06089 Stuart Scientific S.M.3 Magnetic Stirrer Hotplate
ITEM-12168 Stuart Scientific Mini Orbital Shakers Lab Shaking Equipment
ITEM-06017 Syringe Pump
ITEM-07133 Mettler Toledo pH Meter - Spares / Repairs
ITEM-10533 IKA Laboratories RH Basic Stirrer Lab Shaking Equipment
ITEM-10698 Grant BT3 Block Heater Lab Heating Equipment
ITEM-10746 Voss of Maldon MAG/S 200/250 Magnetic Stirrer Lab Shaking Equipment
ITEM-10924 Fisher Brand Pump Lab Equipment (Spare Repairs)
ITEM-06172 Elix 2 Millipore Water Purification System
ITEM-06046 VWR Digital Thermometer
ITEM-04758 Laboratory Glass Filter Tube

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Link Analytical eXL Model 1100-012 X-Ray Imaging & Analysis System Spares/Repair
ITEM-46803
Link Analytical eXL Model 1100-012 System
This system was removed from a university laboratory where it was surplus to requirements.
The main eXL unit initially powered on, supplied power to the monitor, and displayed startup errors (see photos), but the keyboard and mouse were unresponsive. Upon restarting, the monitor and indicator lights did not power up, although internal computer activity could still be heard. Further attempts to power cycle the system were unsuccessful.
Therefore, this system is listed as Spares/Repair.
It is in good overall cosmetic condition.
The system comprises the following:
- Link Analytical eXL
- Model: 1100-012
- Serial No.: 2917
- Link Analytical Monitor
- Model: CLR 1401
- Serial No.: 2665
- Link Analytical Keyboard
- Model: 1487
- Serial No.: 2763
- Link Analytical Mouse and Mouse Mat
- Link Analytical Printer (Epson LQ-500)
- Model: P78PA
- Serial No.: T0011258
- *Note: Printer would fail PAT due to a missing rear cover
- (Box of printer paper included)
Included Manuals:
- Link Analytical eXL System Service Manual
- Link Analytical Disk, Tape & File Sequel, Sequences, Display & Hard Copy, Genie, Video Frame Grabber
- Link Analytical Getting Started – X-Ray Analyser, System Manager, RTS-2/FLS, Auto
- Link Analytical Computer System & Electron Diffraction Pattern Analysis
- Link Analytical Analysis & Imaging
- Link Analytical Quantitative Mapping Operators Manual
Accessories and Additional Parts:
- Box of 10 floppy disks
- Labelled black 'X-Ray' cables and a grey monitor cable (collected as connected)
- 2 x Tracor Northern IPP Series II X-Ray Analyzer Operator Manuals
- 3 x Digital software disks (in blue cases – large format)
- GEMS Sensor – P/N 197093-RS (white)
- Unidentified round metal part
- Boxed metal piece labelled "Scintillator" (assy – ME 0084)
- Metal part tagged "X-Ray Source XA2-57"
- Metal part with Watec WAT-902B CCD Camera and:
- Objective lens: M Plan APO 10 SB 0.23 ∞/0 SLWD 39
- Metal piece with part number AG61-113 etched at the base
- Orange cable marked "AML J011 034"
- Black light source
- Various other cables (not compatible with the eXL)

£ 500.00 (ex. VAT) 1 in stock
Leitz Laborlux S Microscope Type 020-505.030 w/ 3 x Objectives 10/40/100x
ITEM-47270
Leitz Laborlux S Microscope Type 020-505.030
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and in good working order.
Includes:
- 2 x Leica Periplan 10x / 18 Eyepieces (519 750)
Objectives:
- 160/- EF 10/0.25 (519760)
- *160/0.17 PL FLUOTAR 100/1.32 OIL (519847)
- 160/0.17 EF 40/0.65 (519762)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
GEM Indirect Calorimeter ISGEM319 Spares/Repair Lab
ITEM-46579
GEM Indirect Calorimeter ISGEM319 Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonable cosmetic condition. The casing is loose and required securing with a screw, suggesting it may have been opened previously.
The item powers on, but no further testing has been conducted. The previous owner reported it as non-functional, though the specific fault is unknown.
Therefore, it is listed as Spares/Repair.
Includes:
- Pipe fittings
- Grey connector box for the pipe system
Items 1951 to 2000 of 2586