Workshop
Items 101 to 150 of 315

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Büchi B-400 Sample Mixer Homogenizer Grinder Spares/Repair Lab
ITEM-46283
Büchi B-400 Sample Mixer Homogenizer Grinder Lab
This item was removed from a university lab where it was surplus to requirement.
It is in poor cosmetic condition and does not power on, therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Sorvall OTD-COMBI Ultracentrifuge w/ Sorvall T-865.1 Rotor Spares/Repair Lab
ITEM-41834
Sorvall OTD-COMBI Ultracentrifuge Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on. However, the door unlock switch is non-functional, therefore, preventing the unit's ability to lock or open the door.
We were able to open it manually, but the automatic door open function is faulty.
Therefore, it is listed as Spares/Repair.
Also includes the following:
Dupont Instruments Sorvall T-865.1 Rotor.
Serial No: 9330329.
8 Hole rotor.
Tube dimensions: 1.5cm x 8cm.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Hoshizaki Laboratory Ice Maker Flaker Machine Model - FM-120DE Faulty
ITEM-35970
Hoshizaki Laboratory Ice Maker Flaker Machine Model - FM-120DE
This was removed from a university lab where it was surplus to requirements.
The item powers up and is in reasonably good cosmetic condition.
When powered up the item generates ice but it leaks through a crack in the outlet, therefor sold as Spares/Repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
MSE Harrier 18/80 Refrigerated Centrifuge Lab Spares/Repairs
ITEM-31976
MSE Harrier 18/80 Refrigerated Centrifuge
This was removed from a university lab where it was surplus to requirements.
The unit doesn't run above 2000rpm without the alarm going off.
It is sold for spares/repairs.
MSE Rotor 43124.141
Max rpm 6000
SN - H01010 2
4 x Buckets
2 x Yellow Adaptors, holds 1 x 50ml tube
2 x Green Adaptors, holds 7 x 15ml tubes

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Radiometer Analytical Titration Manager - TIM865 Spares/Repairs
ITEM-37140
Radiometer Analytical Titration Manager - TIM865
This item was removed from a university where it was surplus to requirements.
It is in good cosmetic condition and powers up, although the display screen is damaged, therefore, this item is listed as Spares or Repairs.
Also includes;
1x Radiometer Analytical Temperature Sensor: - opened box
Type, T201
Part no. E51M001
1x Radiometer Analytical Electrode Adjustable Stand:- Sealed box
Type, E190
Part no. 809-206
1x B525 Burette stand: -boxed
Part no X51T027
25ml
3x B550 Burette stand: -2x boxed 1x unboxed
Part no X51T028
50ml
1xCable Connection kit Burette stand: -boxed
Part no X91T034
10ml
1x Cell Accessories Kit for Titration Workstation: -boxed
Part no X91T035
1x Cable Connection Kit: -boxed
Part no X91T073
2x Burette B5xx Accessories Titration Workstation: -boxed
Part no X91T036
3x Line Cord:
Part no. A95S002 -Sealed bag
115V (US)
2x Line Cord:
Part no. A95S001 -Sealed bag
230V (Euro)
1x C501X-Serial Cable: - Sealed bag
Part no. A95X501
1xTitration Vessel : -Sealed bag
Part no. X91T056
PP.22-45ml Set of 10pcs
1xTitration Vessel : -Sealed bag
Part no. X91T055
PP.40-100ml Set of 10pcs
1x 1xTitration Vessel : - Opened bag
PP.40-100ml Set of 10pcs (only 4pcs in bag)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Sanyo MCO-5M O2/CO2 Benchtop Laboratory Incubator Lab Spares/Repairs
ITEM-39068
Sanyo MCO-5M O2/CO2 Benchtop Laboratory Incubator
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition. It was tested with a digital thermometer (not included).
The item held an accurate reading at 37ºc but when set to max (57ºc) it would not climb past 38ºc, therefore it's sold as Spares or Repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Night Owl EG&G Berthold Molecular Light Manager Lab Spares/Repairs
ITEM-30254
This Night Owl EG&G Berthold Molecular Light Manager was removed from a university lab where it was surplus to requirements.
The item powers on and is in a reasonably good used cosmetic condition but one of the connection ports on the back is damaged.
The UV Light works and white light can be seen powered on through the back. There is a bag of loose parts inside.
Internal dimensions - D36.5 W52 H46cm
The lab said it wasn't working but didn't give any more details. We assume it is down to the damaged connection port.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Stuart SI500 Orbital Incubator Lab Spares/Repairs
ITEM-42274
Stuart SI500 Orbital Incubator
This item was removed from a university where it was surplus to requirements.
The unit powers on and heats to a temperature of 37˚C (thermometer not included); however, the shaking platform exhibits issues with inconsistent speed and noticeable vibrations at higher RPMs.
Manual inspection suggests possible bearing wear or damage. Both PCB boards were removed.
Therefore, it is listed as Spares/Repair.
It is in good cosmetic condition.
Specifications:
- Model: SI500
- Serial No.: R000100080

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Thermo Scientific MaxQ 6000 Refrigerated Incubator Shaker SHKE6000-8CE Faulty
ITEM-19907
This Thermo Scientific MaxQ 6000 Incubator Shaker Model - 4360 was removed from a university lab where it was surplus to requirements.
The unit has a power board fault.
It is in reasonably good cosmetic condition with some marks from use. The door also does not close properly.
Internal dimensions - D52 x W55 x H67cm
1 Shelf - 52 x 54cm
Shaker Plate - 45 x 45cm
It is sold for spares or repairs due to the electrical fault.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Nikon Diaphot Microscope with Watec CCD Camera Spares/Repair Lab
ITEM-42645
Nikon Diaphot Microscope with Watec CCD Camera
This item was removed from a university laboratory where it was surplus to requirements.
The microscope shows significant cosmetic wear, including stage modifications, attached earth wires, and signs of corrosion on the framework with various paint scuffs.
It did not pass a visual PAT inspection due to poor external cabling and the presence of aluminium foil on certain connectors. Additionally, the illumination bulb failed to power on during testing.
Due to the issues stated above, it is listed as Spares/Repair.
Includes:
- Watec CCD Camera WAT-501 EX2 (Serial No. 00483)
- Alrad MPW 961 Series 12v Power Adapter (Part No. 961010)
- Nikon 80789 binocular with CFW 10X eyepieces
- 5-position turret with:
- Nikon Plan 40/0.55 PH3DM 160/0-2.5 ELWD Objective
- Nikon 10/0.25 160/- Objective

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
MSE Mistral 3000i Refrigerated Centrifuge w/ MSE 43122-105 Spares/Repair Lab
ITEM-42426
MSE Mistral 3000i Benchtop Refrigerated Centrifuge w/ MSE 43122-105 Rotor
This item was removed from a university lab where it was surplus to requirement.
The unit is in good cosmetic condition and powers on; however, it was not possible to test it beyond 1000rpm as the onboard controller froze.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 350.00 (ex. VAT) 1 in stock
Sartorius CPA34001P Laboratory Analytical Balance Scales Spares/Repair Lab
ITEM-31628
Sartorius CPA34001P Laboratory Analytical Balance Scales Spares/Repair Lab
This item was removed from a university where it was surplus to requirement.
It powers on, however during testing the follow error code appeared on-screen; "ERR 54" indicates a problem with the weighing system or internal electronics.
Therefore, it is listed as Spares/Repair.
It is in good condition overall, however as displayed there is damage to the Power Supply port.
The power supply is included

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 310.00 (ex. VAT) 1 in stock
Fisher Scientific Isotemp 3016S Recirculating Water Bath Spares/Repairs
ITEM-42307
Fisher Scientific Isotemp 3016S Recirculating Water Chiller / Heater
This item was removed from a university laboratory where it was surplus to requirements.
It is in very good cosmetic condition. However, one LED bar on the display screen is not illuminating, which may lead to inaccurate temperature readings during operation.
No additional testing was conducted.
Specifications:
- Model: Isotemp 3016S
- Serial No.: 110179037

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 305.00 (ex. VAT) 1 in stock
Nuaire IR Direct Heat Incubator Model No. NU-5510E Lab
ITEM-37276
Nuaire IR Direct Heat Incubator Model-NU-5510E Lab
This item was removed from a university where it was surplus to requirements.
The unit powers up and has been successfully temperature tested.
However, due to a suspected CO2 Sensor/Air Pump fault, this item is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Thermo Scientific Model 232F-AEV-TS ES Series Freezer Lab Spares/Repairs
ITEM-41300
Thermo Scientific ES Series Freezer
Model:THERMO 232F-AEV-TS
This was removed from a university lab where it was surplus to requirements.
The unit powers up, but does not hold set temperature, therefore, it is listed as Spares/Repairs.
It is in reasonable cosmetic condition with marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
RS Biotech Galaxy R 170-300 Incubator Spares/Repair No Solenoid Valve
ITEM-46629
RS Biotech Galaxy R 170-300 Incubator - Spares/Repair
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers on.
However, it is missing a solenoid valve and could not be tested for CO₂ functionality, and when temperature tested it failed to reach Max temp 50ºc.
As such, it is being sold for Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
RS Biotech Galaxy R 170-300 Incubator - Spares/Repair No Solenoid Valve
ITEM-46628
RS Biotech Galaxy R 170-300 Incubator - Spares/Repair
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and has been successfully temperature tested.
However, it is missing a solenoid valve and could not be tested for CO₂ functionality. As such, it is being sold for Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Julabo SE High Tech Heating Circulator Water Bath Spares/Repair Lab
ITEM-38834
Julabo SE High Tech Heating Circulator Water Bath
This item was removed from a university laboratory where it was surplus to requirements.
It powers on but has an electrical issue with the screen, which keeps powering on and off.
Additionally, it does not include a bung and is therefore listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Life Technologies Floid Cell Imaging Station & Recovery Drives Lab Fauty
ITEM-36438
Life Technologies Floid Cell Imaging Station
This was removed from a university lab where it was surplus to requirements.
The unit powers up but is stuck in a boot loop. It is in good cosmetic condition with marks from use.
It is sold for spares/repairs
With it are;
1x Floid Rescue Disk Memory Stick
1x Evo Floid Recovery Memory Stick
1x GlobTek 9 volt Power Supply
M/N: GT-81081-6012-T3

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Captair 321 Smart Fume Hood Spares/Repair Lab
ITEM-46342
Captair 321 Smart Fume Hood
This item was removed from a university laboratory where it was surplus to requirements.
It is in poor cosmetic condition, with a failed visual PAT check due to an exposed fan and wires, which is caused by a missing lid or cover.
The unit does power on, and works. we used the cover from another item to test it safely, but this is not included.
It is sold as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Erbe EIP 2 Irrigation Pump With Vio-Cart Spares/Repair Lab
ITEM-44430
Erbe EIP 2 Irrigation Pump with Vio-Cart
This system was removed from a university lab where it was surplus to requirements.
The unit powers on but has not been tested further. It is in poor cosmetic condition, with the pump's plastic casing broken and held in place by a piece of tape.
A foot pedal is included.
Due to its cosmetic condition and inability to test further, this item is listed as Spares/Repair.
The system comprises the following:
- ERBE EIP 2 Irrigation Pump
- Vio-Cart

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Nuaire IR Direct Heat Incubator Model-NU-5510E Lab Spares/Repairs
ITEM-37275
Nuaire IR Direct Heat Incubator Model-NU-5510E Lab
This item was removed from a university where it was surplus to requirements.
The unit powers up and has been successfully temperature tested.
However, due to a suspected CO2 Sensor/Air Pump fault, this item is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Williams LZ16 Catering Freezer Spares/Repair
ITEM-46203
Williams LZ16 Catering Freezer
This item was removed from a university where it was surplus to requirements.
The freezer is in fairly poor cosmetic condition with marks from use.
However, it has not been tested as it is currently not safe to power on due to exposed internal fan and cables.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Lambda Omnicoll Fraction Collector - Sampler Lab Spares/Repairs
ITEM-36670
Lambda Omnicoll Franction Collector - Sampler
This was removed from a university lab where it was surplus to requirements.
The unit is missing a few parts and we were unable to power it on. For this reason it is sold for spares/repairs.
Rack holds 90 x 5ml

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Syngene Chemi Genius 2 BIO Imaging System with PC & GeneSnap Software
ITEM-35699
This was removed from a university lab where it was surplus to requirements.
The system powers up but we were unable to get it to communicate with the PC.
Everything is in good cosmetic condition but is sold for spares/repairs.
Syngene Chemi Genius 2 BIO Imaging System
Model: ChemiGenius2
Serial#: SYDR2/1569
The unit is in good cosmetic condition both internally and externally with minor surface damage. It powers on with a green light illuminated at the front.
Items internal kettle lead does not connect to the Syngene GV2M30 transilluminated stage, although when powered with an external kettle lead the stage successfully powered on.
Syngene GV2M30 Transilluminated Stage
Model: GV2M30
Serial#: SYGV2/1594
Item powers on with use of external kettle lead.
When powered on all switches and UV light are fully functional.
Unable to test further.
RM Expert 3030 PC
Model: Expert 3030
Serial#: 1053612636
Item powers on.
Unable to connect to Syngene unit.
Item has Gene Snap Software installed Version 6.08.04.
When opening software a message appears: 'NO BYTES READ!' Serial Port Failure.
HP LP2065 Monitor
Model: LP2065
Serial#: CNG709063D
Item powers on and communicates with PC.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Andor Metal Halide Light Source AMH-200-F06S Lab Spares/Repairs
ITEM-35597
This Andor Metal Halide Light Source AMH-200-F0/6S was removed from a university lab where it was surplus to requirements.
The unit powers up but is showing bulb fault 1, which the manual suggests is a data socket issue. The lamp hours are not registering. It is likey the bulb needs replacing.
It is in otherwise good cosmetic condition with minor marks.
Sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
CTC Analytics Leap Technologies HTCPAL Autosampler Spares/Repair Lab
ITEM-46757
CTC Analytics Leap Technologies HTCPAL Autosampler Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however as displayed the controller screen is damage.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Epson Stylus Pro 4900 Large Format Proofing Printer Model K181A Faulty
ITEM-42344
Epson Stylus Pro 4900 Large Format Printer Model K181A
This item was removed from a university laboratory where it was surplus to requirements.
It is in very good cosmetic condition and powers on but displays an error code - 159F, indicating an ATC Motor lock error.
Possible causes include a Roll Unit error, connection failure of the Roll Lock Sensor, or a connection issue between the SUB-D Board and the Main Board.
Therefore, further testing was prevented and it is listed as Spares/Repair.
Specifications:
- Model: K181A
- Serial#: MP2E018257
- Year: 2013
Included:
- 1 x Epson Stylus Pro 4900 Software Disc Vol 1.2
- 1 x USB cable
- 1 x Setup Guide booklet

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Jouan Napco CO2 1000 Incubator Spares/Repair Lab
ITEM-45442
Jouan Napco CO2 1000 Lab Incubator
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonably good cosmetic condition and powers on.
During testing, it successfully reached and stabilized at 37°C. However, it failed to climb any higher when set to 50°C.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
RS Biotech Galaxy S 200 Incubator Lab Spares/Repairs
ITEM-45441
SLS Galaxy S 200 Incubator Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and the incubation is in good working order, but it has an issue with its CO2 sensor.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Precisions Scientific Napco 5420-1 Incubator Lab
ITEM-37321
Precision Scientific Napco 5420-1 Incubator Lab
This item was removed from a university laboratory where it was surplus to requirements.
It powers up and is in good cosmetic condition, but due to a faulty fan, it does not maintain accurate temperatures.
As a result, this unit is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Watson Marlow 205U Auto Drive 1PH With 205BA4 Four Channel Eight Roller
ITEM-42112
Watson Marlow Auto Drive 1PH 205U with 205BA4 Four Channel Eight Roller
This item was removed from a university lab where it was surplus to requirements.
The unit powers on and is in acceptable condition with some visible wear. It has passed a PAT test.
During testing, the unit operated correctly up to 30-40 RPM; however, an "Er. 2" error message displayed above this speed. A red warning symbol (!) appears next to the CCW setting, though it does not impact functionality up to 30-40 RPM.
Due to the fault listed, this item is listed as Spares/Repair.
Specifications:
- Model: 205U Auto Drive 1 PH
- Serial No.: 5120823
- 205BA4 Four Channel Eight Roller
- Part No.: 023.0102.000
- Issue: 1
- Serial No.: 5110991

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Skalar Nitrogen Detector ND20 Lab Spares/Repairs
ITEM-41329
Skalar Nitrogen Detector ND20 Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, but it does not power on. Therefore, it is listed as Spares/Repair.
Model-ND20
S/N-09114
Manufactured-2009

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Varian 3300 GC Gas Chromatograph Lab Spares/Repairs
ITEM-40071
This Varian 3300 GC Gas Chromatograph was removed from a university lab where ti was surplus to requirements.
The unit powers up but has no display and does not respond to inputs.
It is sold for spares/rpeairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
MSE Falcon 6/300 Refrigerated Centrifuge Lab
ITEM-38129
MSE Falcon 6/300 Refrigerated Centrifuge Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on; however, it failed the Portable Appliance Testing (PAT) for Earth Continuity.
Therefore, no further testing was conducted, and it is listed as for Spares/Repair.
Also included in this listing:
1 x Wingshielded Swing-Out Rotor 43124-756
- Serial#: C12R0058

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Napco Model 5410 Incubator Lab
ITEM-40040
Napco Model 5410 Incubator Lab
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition. It was tested with a digital thermometer (not included).
It is in working order, but the safety set point is locked to 40˚C, therefore, it's listed as spares or repairs.
The CO2 function has not been tested.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Kendro HERAcell 150 CO2 Incubator Lab Spares/Repairs
ITEM-44970
Kendro HERAcell 150 CO2 Incubator
This system was removed from a university lab where it was surplus to requirements.
The unit is not heating and requires a replacement relay. It is in good cosmetic condition.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Kendro HERAcell 150 CO2 Incubator Lab Spares/Repairs
ITEM-39065
Kendro HERAcell 150 CO2 Incubator
This system was removed from a university lab where it was surplus to requirements.
The unit is in good working order and has been CO2 tested. It is in good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Sanyo MIR-154 Incubator Lab Spares/Repairs
ITEM-41674
Sanyo MIR-154 Incubator Lab
This item was removed from a university lab where it was surplus to requirement.
The item is in good cosmetic condition and powers on, but when tested, it displayed the message "E04 SSR or Comp relay is shorted," indicating that it cannot heat to its maximum temperature.
PHCbi recommends replacing the board as the only solution, so the item is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Sanyo CO2 Incubator Model MCO-20AIC *Faulty CO2 Sensor* Lab
ITEM-42395
Sanyo CO2 Incubator MCO-20AIC Lab
This item was removed from a university laboratory where it was surplus to requirements.
The incubator powers on and is in good cosmetic condition.
It was functional when temperature tested, but it requires a CO2 sensor replacement.
Included:
- 3 x Racks
- Humidifier Tray

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Sanyo CO2 Incubator MCO-20AIC *Faulty CO2 Sensor* Lab
ITEM-42394
Sanyo CO2 Incubator MCO-20AIC Lab
This item was removed from a university laboratory where it was surplus to requirements.
The incubator powers on and is in good cosmetic condition.
It was functional when temperature tested, but it requires a CO2 sensor replacement due to displaying an E11 error code, which indicates a CO2 sensor abnormality.
Therefore, it is listed as Spares/Repair.
Included:
- 3 x Racks
- Humidifier Tray

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Jouan SA CO2 Incubator Napco 6500 TC - No CO2 Connector Filter
ITEM-40981
Juan SA CO2 Incubator Napco 6500 TC Laboratory Incubator
This item was removed from a university laboratory where it was surplus to requirements.
The unit powers on and has been successfully temperature tested.
However, it is listed as spares or repairs because the CO2 connector filter is missing.
It is in good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Precision Scientific NAPCO 5430 Dual Chamber Co2 Incubator Lab Spares/Repairs
ITEM-44392
Precision Scientific NAPCO 5430 Dual Chamber Co2 Incubator Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition but does not power on, therefore it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Teltron Ltd Tel-X-Ometer 580 X-Ray Generator Deflection System Lab
ITEM-42310
Teltron Ltd Tel-X-Ometer 580 X-Ray Generator Deflection System
This item was removed from a university laboratory where it was surplus to requirements.
It is in very good cosmetic condition, contained in its original packaging.
The lid mechanism operates smoothly, and the deflection holder plate moves without issue around the main dial. It has not been powered on or tested further at our facility.
However, despite the good physical condition, the previous owner reported that the unit does not produce x-rays and is therefore listed as Spares/Repair.
Serial No.: FR04-01

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Teltron Model 580 Tel-X-Ometer X-Ray Diffraction Unit Lab
ITEM-42311
Teltron Ltd Tel-X-Ometer 580 X-Ray Generator Deflection System
This item was removed from a university laboratory where it was surplus to requirements.
It is in very good cosmetic condition, contained in its original packaging.
The lid mechanism operates smoothly, and the deflection holder plate moves without issue around the main dial. It has not been powered on or tested further at our facility.
However, despite the good physical condition, the previous owner reported that although the unit produces x-rays but is not stable enough to be used.
And therefore, is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Migatronic KDO 400 CO2 MIG Welder Spares/Repairs
ITEM-44958
Migatronic KDO 400 CO2 Welder
This system was removed from a university lab where it was surplus to requirements.
The unit has not been powered on due to damaged cables, making it a visual PAT fail (see photos). Other than that, it is in reasonable cosmetic condition.
Due to the damaged cables, this item is listed as Spares/Repair.
Specifications:
- Model: KDO 400
- Serial No.: 8909 1293

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Datarack Floor Standing Server Rack 4 Shelves
ITEM-40048
Datarack Floor Standing Server Rack 4 Shelves
These were removed from a university lab where they were surplus to requirements.
The unit is missing a wheel.
It is sold spares/repairs.
Includes 4 shelves 58x58cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Becker VTC 6/2-09 Motor Pump (Cracked Casing)
ITEM-41338
Becker VTC 6/2-09 Motor Pump
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, there is a crack in the fan's outer casing and therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Fisher Scientific Isotemp 3016S Recirculating Water Chiller / Heating Faulty
ITEM-42266
Fisher Scientific Isotemp 3016S Recirculating Water Chiller / Heater
This item was removed from a university laboratory where it was surplus to requirements.
It is in very good cosmetic condition and powers.
However, two LED bars on the display screen are not illuminating, resulting in inaccurate temperature readings during operation.
Therefore, it is listed as Spares/Repair
Specifications:
- Model: Isotemp 3016S
- Serial No.: 110179038

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 300.00 (ex. VAT) 1 in stock
Coffetek Gourmet Vitro 6 4 Cannister Touch Display Coffee Machine
ITEM-37210
Coffetek Gourmet 83545 Touch Display Coffee Machine Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on. The unit has no power hoppers and is missing the drip tray. It is sold for spares/repairs
Key not included.
Items 101 to 150 of 315