Image of Beckman Coulter Microfuge 22R Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

Beckman Coulter Microfuge 22R Centrifuge Lab Spares/Repairs

ITEM-45574

Beckman Coulter Microfuge 22R Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


The centrifuge powers on and is in fair cosmetic condition. However, it is unable to operate due to an issue with the lid mechanism. The lid button remains illuminated, and pressing it causes the lid to open. Once closed, the button continues to light up, preventing the unit from starting.


It has a F241.5P rotor.


Due to this error, this item is listed as Spares/Repair.

Image of Liebherr Premium 1366 Freezer Spares/Repair - Faulty Display Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

Liebherr Premium 1366 Freezer Spares/Repair - Faulty Display Lab

ITEM-46382

Liebherr Premium 1366 Freezer


This item was removed from a university laboratory where it was surplus to requirements.


The freezer is in good used cosmetic condition.


However, the display screen is faulty and displays intermittently.


Due to this issue, further testing could not be conducted, and it is listed as Spares/Repair.

Image of Liebherr Mediline 1610 Fridge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

Liebherr Mediline 1610 Fridge Spares/Repair Lab

ITEM-46384

Liebherr Mediline 1610 Fridge Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition but has not been tested further due to it failing its PAT on Earth Continuity.


Therefore, it is listed as Spares/Repair.

Image of Liebherr Mediline Model LKUexv 1610 Fridge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

Liebherr Mediline Model LKUexv 1610 Fridge Spares/Repair Lab

ITEM-46449

Liebherr Mediline Model LKUexv 1610 Fridge Lab


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition and powers on, however during testing it failed to reach it's minimum temperature.


Therefore, it is listed as Spares/Repair.


Includes 3 x shelves (60 x 60cm)

Image of LEC+ Model ISU1111 Laboratory Medical Freezer Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

LEC+ Model ISU1111 Laboratory Medical Freezer Spares/Repair Lab

ITEM-46670

LEC+ Model ISU1111 Laboratory Medical Freezer Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition and powers on, however during testing it failed to reach its minimum temperature of -20ºc and instead reached a minium of 12.7ºc.


Therefore, it is listed as Spares/Repair.

Image of LEC Model LR111 Laboratory Refrigerator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

LEC Model LR111 Laboratory Refrigerator Spares/Repair Lab

ITEM-46689

LEC Model LR111 Laboratory Refrigerator


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition, however, during testing it did not drop below 6ºc after being left on all day.


Therefore, it is listed as Spares/Repair.

Image of UVP GelDoc-It Imaging System w/ UVP FirstLight UV & HR Camera Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

UVP GelDoc-It Imaging System w/ UVP FirstLight UV & HR Camera Spares/Repair Lab

ITEM-46901

UVP GelDoc-It Imaging System with HR Camera – Spares/Repair


This item was removed from a university laboratory where it was surplus to requirements.


The system is in reasonable cosmetic condition. The white light function powers on and communicates with the system, confirming power is being received. However, the integrated UVP FirstLight UV Illuminator does not power on when connected through the GelDoc-It system. Notably, the illuminator functions when plugged directly into a wall socket, indicating the issue lies in the power delivery from the main unit rather than the illuminator itself.


Due to this fault, the system is being sold as Spares/Repair.


Includes:

  • GelBase User's Guide
  • 2x User Manuals
  • GelBase/GelBlot Pro
  • Support CD
  • Image Acquisition and Analysis Software CD
  • UVP BioImaging Systems Gel HR Camera
  • UV/White Converter Plate

Image of New Brunswick Water Bath Shaker  Model - Classic C76 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

New Brunswick Water Bath Shaker Model - Classic C76 Spares/Repair Lab

ITEM-46978

New Brunswick Classic C76 Water Bath Shaker


This item was removed from a university laboratory where it was surplus to requirements.


The unit powers on and holds water; however, as soon as the shaker function is activated, water begins to leak from the bottom of the unit.

The internal drain tap is also extremely stiff and difficult to operate, suggesting a possible internal blockage.


There is visible rust inside the water bath, and the item is in poor cosmetic condition overall.


Therefore, it is listed as Spares/Repair.


Model: Classic C76


Image of Liebherr Mediline LKUexv 1610 Fridge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

Liebherr Mediline LKUexv 1610 Fridge Spares/Repair Lab

ITEM-46998

Liebherr Mediline LKUexv 1610 Fridge Spares/Repair Lab


This item was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition and powers on, however during testing it failed to reach its minimum temperature of 3ºc.


Therefore, it is listed as Spares/Repair.

Image of Taylor-Wharton 35HC Liquid Nitrogen Dewar Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 100.00 (ex. VAT) 1 in stock

Taylor-Wharton 35HC Liquid Nitrogen Dewar Lab Spares/Repairs

ITEM-50443

Taylor-Wharton 35HC Liquid Nitrogen Dewar Lab


This item was removed from a facility where it was surplus to requirement.


It is in reasonably good cosmetic condition and remains untested. It has no bung.


Includes;


10 x Sample Holders

Image of Thermo Scientific MAXQ 5000 SHKE5000-1CE (4351) Shaking Incubator Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Thermo Scientific MAXQ 5000 SHKE5000-1CE (4351) Shaking Incubator Lab Faulty

ITEM-39911

Thermo Scientific MAXQ 5000 SHKE5000-1CE (4351) Shaking Incubator


This was removed from a university lab where it was surplus to requirements.


The system is faulty and requires a new controller.


It is in otherwise good cosmetic condition with minor marks.


It is sold for spares/repairs.

Image of Weiss Gallenkamp Sanyo PSC022 Pharma Safe System Stability Chamber Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Weiss Gallenkamp Sanyo PSC022 Pharma Safe System Stability Chamber Lab Faulty

ITEM-37811

Weiss Gallenkamp Sanyo PSC022 Pharma Safe System Stability Chamber


This item was removed from a university lab where it was surplus to requirements.


The unit powers up and is in good cosmetic condition.


It was successfully temperature tested, however, during further testing it failed to retain humidity.


Therefore, it is listed as Spares/Repair.


It has been recently fitted with a new element.


Eurotherm 220 8E controllers for temperature and humidity

Two compartments of size 65cm x 49cm x 20cm (l x w x h)

Image of Heraeus Heracell 150 Co2 Incubator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Heraeus Heracell 150 Co2 Incubator Spares/Repair Lab

ITEM-38197

Heraeus Heracell 150 CO₂ Incubator


This item was removed from a university laboratory where it was surplus to requirements.


The unit powers on, but during testing at a set temperature of 37°C, it would climb to around 33°C before dropping and repeating the cycle. The alarm displayed error code 66: "Deviation of temperature sensors from one another. Temperature signal plausibility doubtful. Contact Service."


It is in good external cosmetic condition, although the copper interior shows tarnishing.


Model: Heracell 150

Image of LEEC Touch 50 Culture Safe CO2 Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

LEEC Touch 50 Culture Safe CO2 Incubator Lab Spares/Repairs

ITEM-38889

LEEC Touch 50 Culture Safe CO2 Incubator


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on. (Thermometer not included)


The CO2 sensor has failed on testing, therefore it is listed as Spares/Repair.

Image of SciQuip Incu-270S Incubator Model - ZDP-A2270A Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

SciQuip Incu-270S Incubator Model - ZDP-A2270A Lab Spares/Repairs

ITEM-38906

SciQuip Incu-270S Incubator Model - ZDP-A2270A


This was removed on from a working lab. It was surplus to requirements.


The item is in a reasonable, used cosmetic condition.


The unit has no power cable and has not been tested.


It is sold for spares/repairs.


2 x Shelves 59.5 x 53cm

Image of New Brunswick Galaxy 14 S CO2 Incubator Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

New Brunswick Galaxy 14 S CO2 Incubator Lab

ITEM-39687

New Brunswick Galaxy 14 S CO2 Incubator


This was removed from a university lab where it was surplus to requirements.


The unit powers up but requires a new CO2 solenoid. It will not inject CO2.


It is sold for spares/repairs.

Image of Lab Companion IS-971R Shaking Incubator Lab Cooling Fault

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Lab Companion IS-971R Shaking Incubator Lab Cooling Fault

ITEM-39716

Lab Companion IS-971R Shaking Incubator


This was removed from a university lab where it was surplus to requirements.


The unit powers up but has a cooling fault. It is seemingly in otherwise working condition.


It is in good cosmetic condition with minor marks


It is sold for spares/repairs.

Image of Leec P3 laboratory Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Leec P3 laboratory Incubator Lab Spares/Repairs

ITEM-39815

Leec P3 laboratory Incubator


This was removed from an industry lab where it was surplus to requirements.


The unit powers up but has issues with temperature regulation. We think the cause of this is a fan fault. (Digital thermometer not included).


It is sold for spares/repairs

Image of New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair

ITEM-39813

New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair


This was removed from a university lab where it was surplus to requirements.


The unit powers up and the incubation function works, but the unit does not shake (the thermometer used for testing is not included).


It is in reasonably good cosmetic condition with minor marks.


It is sold for spares/repairs.

Image of Drive ST1 Mobility Scooter Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Drive ST1 Mobility Scooter Spares/Repair

ITEM-48694

Drive ST1 Mobility Scooter Spares/Repair


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition, but it failed to charge, likely requiring a new battery.


Therefore, it is listed as Spares/Repair.


Includes;


  • Charger
  • Manual

Image of Sanyo O2/CO2 Incubator MC0-18M Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Sanyo O2/CO2 Incubator MC0-18M Spares/Repair Lab

ITEM-47703

Sanyo O2/CO2 Incubator MC0-18M


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in good cosmetic condition with some wear.


The unit displays error message E12, which relates to the temperature probe, and it will exceed set temperatures during operation.


Therefore, it is listed as Spares/Repair.


Image of Sanyo CO2 Incubator - MCO-18AIC (UV) Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Sanyo CO2 Incubator - MCO-18AIC (UV) Spares/Repair Lab

ITEM-48490

Sanyo CO2 Incubator - MCO-18AIC (UV) Spares/Repair Lab


This item was removed from a university laboratory where it was surplus to requirements.


It has been successfully temperature tested; however, the CO2 test failed. The display indicated a CO2 concentration above 5% and continued to climb even after the incubator

had stopped injecting CO2.


Therefore, it is listed as Spares/Repair.


Model: MCO-18AIC (UV)

Image of Kendro Heareus HERAcell 150 Floor Standing Incubator Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Kendro Heareus HERAcell 150 Floor Standing Incubator Spares/Repair

ITEM-49367

Kendro Heareus HERAcell 150 Floor Standing Incubator Spares/Repair


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers up, however during testing it failed to heat up.


It is therefore, listed as Spares/Repair.

Image of Kendro Heareus HERAcell 150 Floor Standing Incubator Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Kendro Heareus HERAcell 150 Floor Standing Incubator Spares/Repair

ITEM-49368

Kendro Heareus HERAcell 150 Floor Standing Incubator Spares/Repair


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers up, however during testing it failed to heat up.


It is therefore, listed as Spares/Repair.

Image of Binder BD 240 Incubator - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Binder BD 240 Incubator - Spares/Repair Lab

ITEM-50437

Binder BD 240 Incubator - Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however, during testing it failed the PAT on insulation.


Therefore, it is listed as Spares/Repair.

Image of  Infors Minitron Shaking Incubator Model AI 72 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Infors Minitron Shaking Incubator Model AI 72 Lab Spares/Repairs

ITEM-44641



Infors Shaking Incubator Model-AI 72 Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition, but the door does not remain shut. The unit powers on, however, when setting the desired temperature, it remains at ambient temperature and does not raise to lower.


Therefore, it is listed as Spares/Repair.

Image of New Brunswick Scientific C24KC Refrigerated Shaking Incubator S/R Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

New Brunswick Scientific C24KC Refrigerated Shaking Incubator S/R Lab

ITEM-48566

New Brunswick Scientific C24KC Refrigerated Shaking Incubator S/R Lab


This item was removed from a university where it was surplus to requirements.


It is in reasonably good cosmetic condition and powers on, however the shaking element does not work.


Therefore, it is listed as Spares/Repair.

Image of Stuart SI500 Orbital Incubator Shaking Incubator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Stuart SI500 Orbital Incubator Shaking Incubator Spares/Repair Lab

ITEM-48567

Stuart SI500 Orbital Incubator Shaking Incubator Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however the shaking element does not work.


Therefore, it is listed as Spares/Repair.

Image of New Brunswick Innova Model 4330 Incubator Shaker Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

New Brunswick Innova Model 4330 Incubator Shaker Lab Spares/Repairs

ITEM-40992

New Brunswick Innova Model 4330 Incubator


This was removed from a university lab where it was surplus to requirements.


The unit heats but does not cool. The shaking works, but requires maintenance.


It is sold for spares/repairs.

Image of New Brunswick Innova 4330 Incubator Shaker Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

New Brunswick Innova 4330 Incubator Shaker Lab Spares/Repairs

ITEM-40991

This New Brunswick Innova 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit powers up but does not shake. The heating and cooling functions work.


It is in reasonably good cosmetic condition with minor marks.

Image of Stuart SI500 Orbital Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Stuart SI500 Orbital Incubator Lab Spares/Repairs

ITEM-42274

Stuart SI500 Orbital Incubator


This item was removed from a university where it was surplus to requirements.


The unit powers on and heats to a temperature of 37˚C (thermometer not included); however, the shaking platform exhibits issues with inconsistent speed and noticeable vibrations at higher RPMs.


Manual inspection suggests possible bearing wear or damage. Both PCB boards were removed.


Therefore, it is listed as Spares/Repair.


It is in good cosmetic condition.


Specifications:

  • Model: SI500
  • Serial No.: R000100080

Image of New Brunswick Innova Type 4330 Incubator Shaker Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

New Brunswick Innova Type 4330 Incubator Shaker Lab

ITEM-40993

This New Brunswick Innova Type 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.


The unit powers up and heats, but does not cool or shake.


It is sold for spares/repairs.

Image of Percival I-30VL Floor Standing Growth Chamber S/R Laboratory

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Percival I-30VL Floor Standing Growth Chamber S/R Laboratory

ITEM-48674

Percival Type I-30VL Floor Standing Growth Chamber – Spares/Repair


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in good cosmetic condition, however the display screen does not function.


It is therefore listed as spares/repair.


Includes;


  • User Manual
  • Intellus Ultra Controller Manual

Image of Sanyo CO2 Incubator Model-MCO 20AIC Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Sanyo CO2 Incubator Model-MCO 20AIC Lab Spares/Repairs

ITEM-37261

Sanyo CO2 Incubator Model MCO-20AIC


This item was removed from a university where it was surplus to requirements.


It powers up but is reported to have a faulty CO2 sensor, displaying an E11 error, and is therefore listed as Spares/Repair.


No further testing was conducted.


The unit is in good cosmetic condition both internally and externally.

Image of Binder CO2 Laboratory Incubator CB 150  Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Binder CO2 Laboratory Incubator CB 150 Lab Spares/Repairs

ITEM-38904

Binder CO2 Laboratory Incubator CB 150


This was removed from a university lab where it was surplus to requirements.


The unit powers up and has been temperature tested (thermometer not included). However, the CO2 sensor is missing, therefore we are unable to test it any further.


It is sold for spares/repairs.

Image of Thermo Scientific Cytomat 24 C - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Thermo Scientific Cytomat 24 C - Spares/Repair Lab

ITEM-40009

Thermo Scientific Cytomat 24 C Lab


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition and powers on.


The unit connects via COM port when linked to a PC running Cytomat software. (not included)


However, it does not execute commands and displays errors within the software, indicating potential internal faults.


As such, this item is listed as spares or repair.

Image of Thermo Scientific Cytomat 24 C-GR Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Thermo Scientific Cytomat 24 C-GR Spares/Repair Lab

ITEM-40010

Thermo Scientific Cytomat 24 C-GR Lab


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition and powers on, however, the unit has a Com port error when connected to Cytomat software.


The internal screen within the door (used for the stacker system) does not power on, and there appear to be faults affecting the stacker system overall.


As such, this item is listed as spares or repair.


Please note:  Software not included.

Image of New Brunswick Scientific Innova CO-170 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

New Brunswick Scientific Innova CO-170 Lab Spares/Repairs

ITEM-40039

New Brunswick Scientific Innova CO-170 Lab


This item was removed from a university lab where it was surplus to requirements.


The unit powers up and is in fairly poor cosmetic condition with some rust, it has been temperature-tested. (thermometer not included)


The unit developed a back-light fault in the screen during CO2 testing. It is sold as Spares/Repair.

Image of Sanyo CO2 Incubator MCO-20AIC *Faulty CO2 Sensor* Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Sanyo CO2 Incubator MCO-20AIC *Faulty CO2 Sensor* Lab

ITEM-42394

Sanyo CO2 Incubator MCO-20AIC Lab


This item was removed from a university laboratory where it was surplus to requirements.


The incubator powers on and is in good cosmetic condition.


It was functional when temperature tested, but it requires a CO2 sensor replacement due to displaying an E11 error code, which indicates a CO2 sensor abnormality.


Therefore, it is listed as Spares/Repair.


Included:

  • 3 x Racks
  • Humidifier Tray

Image of Jouan SA CO2 Incubator Napco 6500 TC - No CO2 Connector Filter

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Jouan SA CO2 Incubator Napco 6500 TC - No CO2 Connector Filter

ITEM-40981

Juan SA CO2 Incubator Napco 6500 TC Laboratory Incubator


This item was removed from a university laboratory where it was surplus to requirements.


The unit powers on and has been successfully temperature tested.


However, it is listed as spares or repairs because the CO2 connector filter is missing.


It is in good cosmetic condition.

Image of Sanyo CO2 Incubator Model MCO-20AIC *Faulty CO2 Sensor* Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Sanyo CO2 Incubator Model MCO-20AIC *Faulty CO2 Sensor* Lab

ITEM-42395

Sanyo CO2 Incubator MCO-20AIC Lab


This item was removed from a university laboratory where it was surplus to requirements.


The incubator powers on and is in good cosmetic condition.


It was functional when temperature tested, but it requires a CO2 sensor replacement.


Included:

  • 3 x Racks
  • Humidifier Tray

Image of RS Biotech Galaxy Co2 Incubator - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

RS Biotech Galaxy Co2 Incubator - Spares/Repair Lab

ITEM-42718

RS Biotech Galaxy CO₂ Incubator


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition and powers on, however, due to the missing glass inner door, further testing could not be carried out.


The item is missing one foot and the internal glass door.


Therefore, it is listed as Spares/Repair.


Includes:

  • Three internal shelves

Model: 170

Serial No.: 1144

Image of Heraeus Heracell 150 Co2 Incubator Spares/Repair - Broken CO2 Port Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Heraeus Heracell 150 Co2 Incubator Spares/Repair - Broken CO2 Port Lab

ITEM-42721

Heraeus Heracell CO₂ Incubator


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in good cosmetic and working condition. This unit was successfully temperature tested, however, due to the CO₂ connecting port at the rear being broken (as shown in photos), the CO₂ functionality was not tested.\


Therefore, it is listed as Spares/Repair.


Includes:

  • Three shelves
  • Humidifying pan

The door seal and inner door catch are in good condition.

Image of RS Biotech Galaxy Co2 Incubator - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

RS Biotech Galaxy Co2 Incubator - Spares/Repair Lab

ITEM-42719

RS Biotech Galaxy Co2 Incubator - Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition and powers on, however during testing it failed to heat and remained at ambient temperature.


Therefore, it is listed as Spares/Repair.

Image of Thermo Scientific Function Line BB15 Co2 Incubator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Thermo Scientific Function Line BB15 Co2 Incubator Spares/Repair Lab

ITEM-42723

Thermo Scientific Function Line BB15 CO₂ Incubator


This item was removed from a university laboratory where it was surplus to requirements.


The incubator powers on, and the display and controls respond correctly. During testing, it was set to 37°C and left to run for 24 hours but did not exceed 19.8°C, consistent with the ambient temperature in the listing room.

No further temperature testing or CO₂ function testing was performed.


Due to the issues stated above, this item was listed as Spares/Repair.


Includes:

  • Three internal shelves

The door seal and inner door catch are in good condition.


In good clean cosmetic condition with functional controls and display, but unable to confirm heating function due to limited temperature rise.

Image of Sanyo MCO-18AIC Co2 UV Incubator Faulty CO2 Sensor Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Sanyo MCO-18AIC Co2 UV Incubator Faulty CO2 Sensor Spares/Repair Lab

ITEM-42717

Sanyo MCO-18AIC Co2 UV Incubator Faulty CO2 Sensor Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and has been successfully temperature tested, however, during CO2 testing it failed to stabilise.


Therefore, it is listed as Spares/Repair.

Image of Binder CB 150 Laboratory CO2 Incubator - Faulty CO2 Sensor - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Binder CB 150 Laboratory CO2 Incubator - Faulty CO2 Sensor - Spares/Repair Lab

ITEM-42857

Binder CB150 Laboratory CO₂ Incubator – Faulty CO₂ Sensor – Spares/Repair


This item was removed from a university lab where it was surplus to requirements.


The unit is in good cosmetic condition and has been successfully temperature tested. However, the CO₂ sensor is faulty and will require replacement.


As a result, CO₂ testing could not be performed, and the item is listed as spares or repair.


Also, the inner door has four independent glass door hatches within the main door, but they are taped closed.

Image of Sanyo MCO-17AI Co2 Incubator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Sanyo MCO-17AI Co2 Incubator Spares/Repair Lab

ITEM-42724

Sanyo MCO-17AI CO₂ Incubator


This item was removed from a university laboratory where it was surplus to requirements.


The unit powers on and the display and controls respond as expected. It was set to 37°C and allowed to run for several hours, but the internal temperature remained at room temperature.


The external door handle is broken, but the inner door catch and door seal are in good condition.


Due to the issues stated above, it is listed as Spares/Repair.


Includes:

  • Three internal shelves
  • Humidifying pan

Image of Binder CB 150 Laboratory CO2 Incubator -Faulty CO2 Sensor -Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Binder CB 150 Laboratory CO2 Incubator -Faulty CO2 Sensor -Spares/Repair Lab

ITEM-42858

Binder CB150 Laboratory CO₂ Incubator – Faulty CO₂ Sensor – Spares/Repair


This item was removed from a university lab where it was surplus to requirements.


The unit is in good cosmetic condition and has been successfully temperature tested. However, the CO₂ sensor is faulty and will require replacement.


As a result, CO₂ testing could not be performed, and the item is listed as spares or repair.

Image of Binder KB 240 Refrigerated Incubator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 75.00 (ex. VAT) 1 in stock

Binder KB 240 Refrigerated Incubator Spares/Repair Lab

ITEM-42729

Binder KB 240 Refrigerated Incubator


This item was removed from a facility where it was surplus to requirement.


The unit powers on, and the screen is functional.


However, temperature settings could not be adjusted during testing, and the unit did not rise above ambient temperature when left running.


Therefore, it is listed as Spares/Repair.