Biotechnology
Items 151 to 200 of 287
£ 1,350.00 (ex. VAT) 1 in stock
Amersham Pharmacia Biotrak ll Plate Washer 4 Lab
ITEM-37701
This Biotrak ll Plate Washer 4 was removed from a university lab where it was surplus to requirements.
The item powers on and is in good cosmetic condition, we are unable to test it further at our facility.
£ 1,340.00 (ex. VAT) 1 in stock
Instavis AG InsituPro VS Hybridisation Instrument
ITEM-42298
Instavis AG InsituPro VS Hybridisation Instrument
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in very good cosmetic condition. We are unable to conduct further testing at our facility.
Includes:
- 1 x User Manual
- 1 x Data Cable
- 7 x 250ml Nalgene solvent bottles
- 1 x Tube holder tray
£ 1,300.00 (ex. VAT) 1 in stock
ProMega Maxwell RSC AS4500 System & Accessories
ITEM-49829
ProMega Maxwell RSC AS4500 System & Accessories
This item was removed from a facility where it was surplus to requirement.
It is in very good cosmetic condition and in good working order.
Includes;
- 1 x Tablet PC Holder
- 1 x Maxwell RSC/CSC Deck Tray (A10000992)
£ 1,300.00 (ex. VAT) 1 in stock
ProMega Maxwell RSC AS4500 System & Deck Tray Lab
ITEM-49830
ProMega Maxwell RSC AS4500 System & Deck Tray Lab
This system was removed from a facility where it was surplus to requirement.
It is in excellent cosmetic condition and is in good working order.
Includes;
- 1 x Maxwell RSC/CSC Deck Tray (A10001310)
£ 1,250.00 (ex. VAT) 1 in stock
Perkin Elmer Abi Prism 377 DNA Sequencer Lab
ITEM-45511
Perkin Elmer ABI Prism 377 DNA Sequencer
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition. It was tested using an in-house power cable (power supply not included).
The system powers up, with multiple fans running and front indicator lights illuminating. The amber/yellow light flashes at the end of the startup sequence, which may indicate the absence of a connection to a control PC, but we could not verify this due to the lack of a user manual.
£ 1,250.00 (ex. VAT) 1 in stock
BMG LabTechnologies ThermoStar Microplate Incubator Shaker Lab
ITEM-46380
BMG LabTechnologies ThermoStar Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and in working order.
£ 1,250.00 (ex. VAT) 1 in stock
Vilber BLX-365 Crosslinker Lab
ITEM-48313
Vilber BLX-365 Crosslinker Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
The lab confirmed it was in good working order prior to removal.
£ 1,250.00 (ex. VAT) 1 in stock
Bionano Genomics Saphyr Generation 1 Optical Genome Mapping System
ITEM-49005
Bionano Genomics Saphyr Optical Genome Mapping System
This system was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition but cannot be tested on site due to restrictions involving Class 3+ lasers. The previous owner confirmed it was in full working order prior to removal.
The customer noted that the Bionano Access software is free to download and that data is stored within the Access platform rather than on the system itself. Consumables for this model will be available for purchase until the end of this year (2025), and Bionano will continue to support and service Generation 1 Saphyr Systems under warranty until December 31, 2026.
Includes:
- 8x Saphyr System Filters
- 2x ThorLabs Inc Lens Tissue
- 1x Bag of SP Sheaths (P/N: 20381)
- 2x Bags of DLS Amber Tubes (P/N: 20362)
- 40 µM Cell Strainer (P/N: 20403)
- Protein Lobind Microcentrifuge Tubes, 1.5 mL (P/N: 20422)
- Protein Lobind Microcentrifuge Tubes, 0.5 mL (P/N: 20421)
- 2x Saphyr Chip inside Chip Clip (REF: 60211)
£ 1,240.00 (ex. VAT) 1 in stock
Perkin Elmer Abi Prism 377 DNA Sequencer Lab
ITEM-37336
Perkin Elmer Abi Prism 377 DNA Sequencer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
£ 1,205.00 (ex. VAT) 1 in stock
Berthold Technologies Mithras LB 940 Microplate Reader Lab
ITEM-31458
Berthold Technologies Mithras LB 940 Microplate Reader
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further without the software.
It is in good cosmetic condition with minor marks.
£ 1,130.00 (ex. VAT) 1 in stock
Applied Biosystems Veriti Model 384 Well Thermal Cycler Lab
ITEM-34761
This Applied Biosystems Veriti 384 Well Thermal Cycler was removed from a university lab where it was surplus to requirements.
This item powers on and is in good cosmetic condition with very minor surface damage.
It has been tested with a digital thermometer (not included).
Block type: 384 well
£ 1,100.00 (ex. VAT) 1 in stock
Stratagene MX300P Multiplex Quantitative PCR System Lab
ITEM-48589
Stratagene MX300P Multiplex Quantitative PCR System Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
£ 1,000.00 (ex. VAT) 1 in stock
Syngene G-Box F3 Gel Imaging System With Mitsubishi P93D Printer
ITEM-35866
Syngene G-Box F3 Gel Imaging System
This was removed from a university lab where it was surplus to requirements.
The system powers up but we were unable to test it further without connection to a PC. The Transilluminator is missing a few bulbs but is working.
It is in reasonable cosmetic condition but has heavy staining inside.
Included are;
Includes:
-Mitsubishi P93D Printer
-Digital Monochrome Printer Driver Disc Version 1.2
Printer is functional
Model- G-Box F3
Serial number- DR4V2/2703
Model- P93DW
Serial number- 6011497
£ 1,000.00 (ex. VAT) 1 in stock
GE Healthcare Ready to Process Wave 25 Bioreactor System Lab
ITEM-31528
This Ready to Process Wave 25 Bioreactor System was removed from a university lab where it was surplus to requirements.
None of the items have been tested because the power supply was not included.
The system is in good cosmetic condition with minor marks from use.
Included are;
1x GE Ready to Process CBCU
Code no.28998100
Mfg year 2015
1x GE Ready to Process Pump 25 w/ 2x pump heads
Code No. 29000704
Mfg year 2015
There is some damage to the housing of the unit on the bottom LHS of the unit -as seen in photo.
2x PumpHeads:
114DV OEM Pumpheads
Prod Nos.
113.5000.R33
Ser Nos.
66056-2
66056-3
Mfg 2015
1x Icellis Docking Station
Prod No. 820284
The unit is in good cosmetic condition
The unit has a 32 Oz Nalgene vessel,
1x PALL Life Sciences Icellis Nano lid
Ser No. P004_G_169
1x Hamilton Visiferm DO 120 Sensor:
Part no. 242450
Heat Nos.
•541742
•425755
Ser No. 026570
1x Icellis Perfusion Module w/ 2x pump heads
Prod No. 820288
Pumpheads:
102R Twin Roller low-flow
Prod No. 013.211.000
£ 1,000.00 (ex. VAT) 1 in stock
Bio-Rad S1000 Thermal Cycler with Reaction Module 48 Lab
ITEM-50449
Bio-Rad S1000 Thermal Cycler Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
£ 1,000.00 (ex. VAT) 1 in stock
TopCount NXT Microplate Scintillation & Luminescence Counter C990201 Lab
ITEM-20638
TopCount NXT Microplate Scintillation & Luminescence Counter
This item was removed from a university laboratory where it was surplus to requirements.
The built-in PC powers on and is in good cosmetic condition, running on Windows XP. The instrument control software attempts to initiate but fails, displaying an "Abnormal error" message on the desktop. The bottom half of the unit could not be powered on, though it is also in good cosmetic condition. No further testing has been conducted.
Due to the error preventing further testing and the bottom unit to power on. This system is listed as Spares/Repair.
Accessories:
- 1x Perkin Elmer TopCount NXT (for Windows XP) CD
- Part No.: 7801572 Rev, F
- Version: 2.54.1
- 1x Windows NT Service Pack 3 CD
- 1x TopCount Licence ID Key Floppy Disk
- Part No.: 7800575/A
- S/W Version: 1.00
- Enhanced Security Enabled Disk 1 of 1 (5/01/03)
- 1x TopCount NXT Master Floppy Disk (set of 3)
- Part No.: 7800358/D
- 9827
- 1x Hologram - NXT Floppy Disks (set of 4)
- Part No.: 7800359/D
- 9827
- 1x DAC DATA BACKUP Floppy Disk
- 1x TopCount Floppy Disk
- S/N: 419790
- 9902
- 1x Perkin Elmer Topseal Micro Plate Heat Sealing Film
- Lot No.: PW0-04419
- Condition: Opened box, good cosmetic condition
Manuals:
- 1x Sealed Windows NT Workstation Basics and Installation
- Part No.: 236-00037
- 1x Packard TopCount NXT Quick Reference Guide
- Version 1
Additional Components:
- 2x Microplate Holders (Not in good cosmetic condition; plastic surrounds are cracked and broken, with metal housing damage as seen in photos)
- 1x Lenovo Monitor (Type 9227-AE1) - Powers on and displays clearly
- 1x Dell Keyboard (Model: KB212-B) - Good cosmetic condition and responsive to the built-in PC
- 1x Microsoft Mouse (Part No.: 58264) - Good cosmetic condition and responsive to the built-in PC
- 1x VGA Cable - Good cosmetic condition, responsive to both the monitor and built-in PC
Model: 7401280
£ 1,000.00 (ex. VAT) 1 in stock
Life Technologies Ion Torrent PGM Sequencer, One Touch 2, One Touch ES System
ITEM-29914
Life Technologies Ion Torrent PGM Sequencer, One Touch 2, One Touch ES System
This Life Technologies Ion Torrent system was removed from a university lab where it was surplus to requirements.
The system powers up and is in good cosmetic condition with minor marks, no further testing has been done.
We couldn't test the lid locking/holding mechanism since the software couldn't be accessed.
The system consists of the following:
Life Technologies Ion Torrent PGM
Life Technologies Ion OneTouch ES Enrichment System Module
-The item successfully powers on, and upon pressing the start/stop button, the arm initiates movement. No further testing was conducted.
Life Technologies Ion Torrent OneTouch 2 Instrument Next Generation Sequencing
-The item powers on, and boots to user creation. When attempting to create an account, a "read-only" message appeared.
£ 1,000.00 (ex. VAT) 1 in stock
Life Technologies Ion Torrent PGM Sequencer, One Touch 2, One Touch ES System
ITEM-29915
Life Technologies Ion Torrent PGM Sequencer, One Touch 2, One Touch ES System
This Life Technologies Ion Torrent system was removed from a university lab where it was surplus to requirements.
The system powers up and is in good cosmetic condition with minor marks, no further testing has been done.
The system consists of the following:
Life Technologies Ion Torrent PGM
Life Technologies Ion OneTouch ES Enrichment System Module
The device powers on and when the start/stop button is pressed, the arm begins to move. No further testing has been done.
Life Technologies Ion Torrent OneTouch 2 Instrument Next Generation Sequencing
The device has been turned on and the system is booting up. I used the touchscreen to open the lid, which successfully opened.
Life Technologies Ion Torrent Ultra-Turrax Tube Drive for PGM (Personal Genome Machine) by IKA
The device has been turned on successfully. I was able to adjust the timer settings as required.
£ 1,000.00 (ex. VAT) 1 in stock
Life Technologies Ion Torrent PGM Sequencer, One Touch 2, ES System
ITEM-34846
Life Technologies Ion Torrent PGM Sequencer, One Touch 2, ES System
This was removed from a university lab where it was surplus to requirements.
All modules of the system power up but have not been tested further.
Included are;
Life Technologies Ion OneTouch ES Enrichment System Module
S/N - 394314
Life Technologies Ion Torrent OneTouch 2 Instrument Next Generation Sequencing
S/N - 2456280-0981
Ref - INS1005527
Life Technologies Ion Torrent Personal Genome Machine
Ion PGM System.
S/N: 11C120503
Release: 5.10.0
Datacollect version: 489
LiveView version: 755
Hw8560 version: 134 Firmware version: 53 FPGA version: 81.5.4
Script version: 22.0.0
OS: 21
Graphics: 36
TSLink version: 1.0.5
Board version: 4 A.1
Board serial: 001164
Mac Addr: 00:21:73:00:04:8c
Kernel Build: #50 PREEMPT Fri Nov 5 10:13:40 EDT 2010
u-boot Build: U-Boot 1.1.6 (Jan 6 2011 - 16:46:08)
Data storage: 1459716 MB free out of 1548190 MB (94% free)
£ 1,000.00 (ex. VAT) 1 in stock
J&M Tidas 8xout/8xin/rs422 Microscopic Spectrometer Lab
ITEM-45379
J&M Tidas 8xout/8xin/rs422 Microscopic Spectrometer
This item was removed from a university where it was surplus to requirements.
This item is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.
Specifications:
- Model: 8xout/8xin/rs422
- Serial No.: 2003-25804
Included:
- Imaging Source DFK 41AFO2 Camera
- JM 026065 Filter Housing
- JM 025865 Filter Housing
- Light source connection
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Cytiva Xcellerex XDR-10 SLAVE MAX Benchtop Bioreactor System Spares/Repair
ITEM-47310
Cytiva Xcellerex XDR-10 SLAVE MAX Benchtop Bioreactor System
This system was removed from a university laboratory where it was surplus to requirements.
The system is in good cosmetic condition and powers on, however, the main unit has failed a PAT on insulation.
Therefore, we are unable to test the system further, and it is listed as Spares/Repair.
The system comprises the following:
- 1 x Cytiva Xcellerex XDR-10 SLAVE MAX Benchtop Bioreactor Controller
- 1 x Cytiva Xcellerex XDR-10
- 1 x Mettler Toledo PBA655-B60 Weighing Platform
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Perkin Elmer Fusion A Microplate Reader Model: A153603 Lab
ITEM-20582
This Perkin Elmer Fusion A Microplate Reader Model: A153603 was removed from a university lab where it was surplus to requirements.
The system has been professionally serviced and is in full working order. The PC does continually come up with a server busy message, and we have been unable to resolve that, but there is a workaround.
The system is fitted with a 400mw laser.
The instrument is functioning fine and can run samples smoothly.
Failed PMT Dark Count (Photon Counting) - Failed due to high thermal electron current in the PMT due to high voltage in this mode. This will not affect the functionality of the instrument.
Passed PMT Dark (Charge Integration) and LED Control.
Server Busy message - This action cannot be completed because the other program is busy. Choose ‘Switch to’ to activate the busy program and correct the problem.
It is in very good cosmetic condition with only minor marks from use.
£ 1,000.00 (ex. VAT) 1 in stock
Matrix Technologies PlateMate 2x2 Automated Pipetting Workstation
ITEM-24231
Matrix Technologies PlateMate 2x2 Automated Pipetting Workstation
This was removed from a university lab where it was surplus to requirements.
The unit powers up and goes through all start-up sequences. It is in good cosmetic condition with minor marks.
It is fitted with a pipette head with 96 tips at 300µl.
£ 1,000.00 (ex. VAT) 1 in stock
Applied Biosystems 7900HT Fast Real Time PCR System with 7067/4 Stacker Lab
ITEM-26003
This Applied Biosystems 7900HT Fast Real Time PCR System was removed from a university lab where it was surplus to requirements.
The system is in good used cosmetic condition. The lab confirmed it was in working order prior to removal.
We have been able to connect the unit to the PC, but are unable to test it further.
It consists of the following parts:
1 x Applied Biosystems 7900HT
Part no. 4330966
SN - 279002990
1 x SICK CLV422-1910S02 Fixed barcode scanner
1 x AB 7067/4 Microplate stacker.
1 x Symbol Barcode Scanner.
1 x Dell Optiplex 960 PC with Dell Monitor, keyboard and mouse.
The has the following software installed:-
Applied Biosystems 7900HT Version 2.4 Sequence Detection Systems (SDS)
Applied Biosystems RQ Manager Version 1.2.1
We have all the passwords, which are available on request once the system has been sold.
£ 1,000.00 (ex. VAT) 1 in stock
Applikon My-Control Bioreactor Controller Z310210011 Lab
ITEM-31529
This Applikon My-Control Z310210011 Bioreactor Controller was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
It is in good cosmetic condition with marks from use.
£ 1,000.00 (ex. VAT) 3 in stock
Applikon My-Control Z310210011 Bioreactor Controller Lab
ITEM-31530
This Applikon My-Control Z310210011 Bioreactor Controller was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
It is in good cosmetic condition with marks from use.
£ 1,000.00 (ex. VAT) 1 in stock
BIO-RAD iCycler Thermal Cycler with iQ5 Multicolor PCR Detection System Lab
ITEM-35025
BIO-RAD iCycler Thermal Cycler with iQ5 PCR Detection System Lab
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks.
£ 1,000.00 (ex. VAT) 1 in stock
Applied Biosystems 7500 Fast Real-Time PCR System Lab
ITEM-43176
Applied Biosystems 7500 Fast Real-Time PCR System Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Includes;
- Blank Transport Plate
£ 1,000.00 (ex. VAT) 1 in stock
ION Torrent PGM Unit With ION OneTouch 2 Unit And ION OneTouch ES Unit Lab
ITEM-46340
ION Torrent PGM Unit With ION OneTouch 2 Unit And ION OneTouch ES Unit Lab
This system was removed from a university laboratory where it was surplus to requirements.
The units included are in good cosmetic condition and power on, but further testing at our facility was not possible.
According to the previous owner, the system was operational when last used; however, that was over eight years ago.
Includes:
- ION Torrent PGM
- ION OneTouch 2
- ION OneTouch ES
£ 1,000.00 (ex. VAT) 1 in stock
Promega GloMax 9101-002 96 Microplate Luminometer Lab
ITEM-47169
Promega GloMax 9101-002 96 Microplate Luminometer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
The previous owner has stated it was working prior to decommissioning.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Thermo Scientific Varioskan Flash 3001 Microplate Reader System S/R Lab
ITEM-47322
Thermo Scientific Varioskan Flash 3001 Microplate Reader
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good used cosmetic condition with various marks and signs of general use.
It powers on, the software communicates with the instrument, and the tray operates in and out.
However, there is an intermittent issue where the system sometimes displays the error: "No tray attached to the X carriage. The tray carriage will not move unless there is a tray".
Therefore, it is listed as Spares/Repair.
Includes:
- Thermo Scientific Varioskan Flash 3001 Microplate Reader with 96-well plate fitted
- Dell Latitude E6530 laptop running Windows 7 with Varioskan SkanIT software (the rubber finish on interior has become sticky with age, a common issue)
- USB connection cable
Model: Varioskan Flash 3001
£ 1,000.00 (ex. VAT) 1 in stock
Diagnostic Automation, Inc. DAR800 Microplate Reader Lab
ITEM-48536
Diagnostic Automation, Inc. DAR800 Microplate Reader Lab
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Includes:
- GEN5CL Ver 1.11 software disk
- Diagauto Fertility assay disk
- Diagauto Thyroid assay disk
- Diagauto Steroid assay disk
- Diagauto TH assay disk
- Manual
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
illumina MiSeq DNA Sequencer System Spares/Repair Lab
ITEM-49075
illumina MiSeq DNA Sequencer System Spares/Repair Lab
This system was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, during testing the following error was noted; The FPGA reported an error while executing command "YHOME"; error message: "ERROR: Home sensor never tripped error.".
Therefore, we were unable to conduct further testing and it is listed as Spares/Repair.
Software installed;
MiSeq Control Software 4.1.0.656
MiSeq Test Software 4.0.0.19
£ 900.00 (ex. VAT) 1 in stock
Agilent 3D CE Capillary Electrophoresis Unit Model: G1600AX Lab
ITEM-36258
Agilent 3D CE Capillary Electrophoresis Unit Model: G1600AX
Serial#: DEO1602285
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powered on in testing.
£ 800.00 (ex. VAT) 1 in stock
Job Lot of 12 x PLH Medical LTD Wall Mounted X-Ray Light Boxes Lab
ITEM-50136
Job Lot of 12 x PLH Medical LTD Wall Mounted X-Ray Light Boxes Lab
This job lot was removed from a university where it was surplus to requirement.
All the included light boxes are in good cosmetic condition and in good working order.
Individual Dimensions;
Length: 75cm
Width: 12 cm
Height: 55 cm
Weight: 15 kg
£ 800.00 (ex. VAT) 1 in stock
Biomerieux Nuclisens MiniMag Magnetic Processing System Nucleic Acid Extraction
ITEM-42436
Biomerieux Nuclisens MiniMag Magnetic Processing System Nucleic Acid Extraction
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.
Tested with an in-house Power Supply. (power supply not included)
£ 800.00 (ex. VAT) 1 in stock
Uvitec Uvidoc Gel Imaging System With Monitor And Thermal Printer Lab
ITEM-45378
Uvitec Uvidoc Gel Imaging System With Monitor And Thermal Printer
This system was removed from a university lab where it was surplus to requirements.
All included units are in good cosmetic condition and appear to be in working order.
We are unable to conduct further testing at our facility.
System consists of:
- Uvitec Uvidoc Gel Imaging System DOC-008.XD
- S/N- 04 10887
- Rainbow CCTV RMBI92 Monitor
- S/N- 0303017047
- Mitsubushi P91E Thermal Printer
£ 800.00 (ex. VAT) 1 in stock
Agilent 2100 Bioanalyser G2938C Lab
ITEM-49751
Agilent 2100 Bioanalyser G2938C Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 800.00 (ex. VAT) 1 in stock
Perkin Elmer Victor3 1420 Multilabel Counter & Liquid Dispenser w/Software Lab
ITEM-36918
Perkin Elmer Victor3 1420 Multilabel Counter & Liquid Dispenser
This was removed from a university lab where it was surplus to requirements.
The system has been professionally serviced and is in full working order. A full report is available on request.
Model - Victor 3
PN - 1420-012
SN - 4207484
Liquid Dispenser
PN - 1420-2550
SN - 420250011
Both units are connected together and both power on.
Comes with:-
RS232 Cable
ARCNET Cable
Software/Manual:-
1420 Software Version 3.0 Revision 5 (1086 3390-40 D)
WorkOut2 Data Analysis Software Version 2.0 (1420-3050)
1420 Multilabel Counter Instrument Manual
£ 750.00 (ex. VAT) 1 in stock
UVP UV/White Transilluminator Imaging System & Camera TMW-20 PN 95-0145-05 Lab
ITEM-31863
UVP UV/White Transilluminator Imaging System & Camera TMW-20 PN 95-0145-05
This item was removed from a university lab where it was surplus to requirements.
The system powers up and is in good cosmetic condition with minor marks from use.
It is in full working order.
Included with it is;
1x Canon Powershot G10 Digital Camera
S/N: 7188100663
£ 750.00 (ex. VAT) 1 in stock
Applied Biosystems 7300 Real Time PCR System with PC & Software Lab
ITEM-30000
This Applied Biosystems 7300 Real Time PCR System was removed from a university lab where it was surplus to requirements.
The system is comprised of;
1 x Applied Biosystems 7300 Real-Time PCR Unit.
1 x Dell Optiplex 380 with Monitor, keyboard, mouse, USB cable & monitor cable.
Running Applied Biosystems Sequence Detection Software (SDS)
Version 1.2.3.
The Dell has a Fresh install of Windows XP.
The 7300 has had a function test run:
USB - Pass
CCD - Pass (version 2.19)
Filter Wheel - Pass (FW version G2.10)
Shutter - Pass (FW version G2.10)
Lamp - Pass (FW version G2.10)
Thermal Cycler - Pass (G2.10 Firmware is up to date)
The lamp status is Good.
It has 1444 Usage hours.
It was last replaced 08/01/2008.
The unit will require the ROI calibration.
£ 750.00 (ex. VAT) 1 in stock
Applied Biosystems ABI Prism 7900HT Sequence Detection System Lab Spares/Repairs
ITEM-30573
Applied Biosystems ABI Prism 7900HT
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has the following issues.
The 7900 did connect to the PC at first but there appears to be a fault with the plate loader. The door will not open when instructed. If you try to run a program you get a 3003 error. 'unable to load the plate, Tray not at up position'.
There was a loud humming noise coming from the unit which appeared to get louder the longer it was switched on. Then would no longer connect to the PC. We have removed the side panels but cannot see any obvious issues.
It is sold for spares/repairs.
The PC is included.
Dell Optiplex PC
Dell 17" Monitor
Keyboard & Mouse
USB Cable
DVI Cable
All parts power on and work, the pc has ABI 7900HT Sequence Detection Systems Version 2.4.1 Software.
£ 750.00 (ex. VAT) 1 in stock
Applied Biosciences 7900HT Fast Real-Time PCR Complete System Lab
ITEM-41491
Applied Biosciences 7900 HT Fast Real-Time PCR Complete System Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Includes:
- 16A 1Phase cable
£ 750.00 (ex. VAT) 1 in stock
Applied Biosystems 7500 Fast Real-Time PCR System Lab
ITEM-46339
Agilent Technologies DNA Microarray Scanner G2505 B Lab
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on; however, further testing at our facility was not possible.
The previous owner noted that it was in working order when last used.
£ 730.00 (ex. VAT) 1 in stock
UVP Visi-Blue Transilluminator Type VB-26 Lab
ITEM-37342
UVP Visi-Blue Transilluminator Model Type VB-26 Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
Specifications;
- Model: VB-26
- S/N: J116764
£ 720.00 (ex. VAT) 1 in stock
UVP Visi-Blue Transilluminator Model VB-26 Lab
ITEM-37341
UVP Visi-Blue Transilluminator Model Type VB-26 Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
Specifications;
- Model: VB-26
- S/N: J116754
£ 710.00 (ex. VAT) 1 in stock
UVP Visi-Blue Transilluminator Model Type VB-26 Lab
ITEM-37340
UVP Visi-Blue Transilluminator Model Type VB-26 Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
Specifications;
- Model: VB-26
- S/N: J11544
£ 700.00 (ex. VAT) 1 in stock
Ingeny PhorLI IPU-S Vertical Electrophoresis System
ITEM-37755
INGENYphorU IPU-S Vertical Electrophoresis System
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition with marks from use.
The unit is watertight and the valve is working.
Also included:
FisherBrand HU13
FisherBrand HU6
INGENY phorLI
Deca Probe Series
Invitrogen Novex Mini-Cell
£ 700.00 (ex. VAT) 1 in stock
Beckman Coulter Biomek Robotic Transport A23467 & Two ALP Plate Movers Lab
ITEM-38067
Beckman Coulter Biomek Robotic Transport and Two ALP Plate Movers
This system was removed from a university where it was surplus to requirement.
All items are in very good cosmetic condition but are untested due to the control system not being included.
The system consists of the following:
Biomek Robotic Transport
Serial No. 2950119
XP Power PSU with 24v outlet for Biomek Robotic Transport
Model PUP110-14-S
2 x Biomek Alp Conveyers, both with Microscan barcode readers
Serial Nos. A16512AD1011110002. 394426AD0811100001
Microscan barcode readers
Model MS-710
Serial Nos. 0904608 1221144
£ 700.00 (ex. VAT) 1 in stock
UVP Visi-Blue Transilluminator Model- VB-26
ITEM-37339
UVP Visi-Blue Transilluminator Model Type VB-26 Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
Specifications;
- Model: VB-26
- S/N: J116744
Items 151 to 200 of 287