SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Priorclave EV100 Top-Loader Autoclave Lab Spares/Repairs
ITEM-21246
This was removed from a university lab where it was surplus to requirements.
The system has a main board fault. It does not heat up as a result.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Astell AMA240N Floorstanding Autoclave Lab Spares/Repairs
ITEM-39207
Astell ASA240 Floorstanding Autoclave
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in reasonably good cosmetic condition externally. However, the internal plastic lid cover supports have been snapped off to release the lock and remove the lid.
This allows access, but the unit remains inoperable for standard use. Therefore, it is sold as Spares/Repair.
As displayed, it is in poor cosmetic condition internally.
Specifications;
- Model- AMA240N
- S/N- CLN51381

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Scotsman Ice Machine Model AF20 Lab Spares/Repairs
ITEM-24772
This was removed from a university lab where it was surplus to requirements.
The unit powers up and holds mains water pressure but has an issue with evaporation temperature being high, and/or and issue with auger rotation. It likely requires an NTC sensor.
It is sold for spares/repairs

£ 500.00 (ex. VAT) 1 in stock
Qiagen Rotor-Disc Heat Sealer Lab
ITEM-31394
This Qiagen Rotor-Disc Heat Sealer was removed from a university lab where it was surplus to requirements.
The item powers on and heats up. It is in reasonably good cosmetic condition with minor marks from use.
Holds 36 x 0.2ml and 9 x 2ml

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Weiss Gallenkamp Sanyo PSC022 Pharma Safe System Stability Chamber Lab Faulty
ITEM-37811
Weiss Gallenkamp Sanyo PSC022 Pharma Safe System Stability Chamber
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition.
It was successfully temperature tested, however, during further testing it failed to retain humidity.
Therefore, it is listed as Spares/Repair.
It has been recently fitted with a new element.
Eurotherm 220 8E controllers for temperature and humidity
Two compartments of size 65cm x 49cm x 20cm (l x w x h)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman L8-80MW Ultracentrifuge Lab
ITEM-44394
Beckman L8-80 Ultracentrifuge Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition externally and powers on, however, when tested we attempted to run the unit with a 70Ti rotor (not included), but encountered cooling system and speed sensor errors.
Also, oil was discovered under the rotor and in the chamber/motor area, possibly due to a worn seal.
Due to the above faults, this item is listed as Spares/Repair.
The 3-phase plug has been removed and there is no rotor included in the sale.
Also included:
1 x Operation Key
1 x Original User Manual

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Revco 8930 EXF60086V -86 Freezer Lab Spares/Repairs
ITEM-44605
Thermo Scientific Revco ExF Freezer
This item was removed from a laboratory where it was surplus to requirements.
This item is in fair cosmetic condition.
The unit does not power on and no further tests have been conducted. It is being sold as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Forma 8694 -86°C Double Compartment ULT Freezer Spares/Repair
ITEM-37195
Thermo Scientific Forma 8694 -86°C Double Compartment ULT Freezer Lab
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition, however, during testing, the unit powered on but emitted buzzing sounds followed by hissing and smoke.
Therefore, it is listed as Spares/Repair

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Savant SPD1010 SpeedVac Concentrator With AC-1 Phase Motor
ITEM-37273
Thermo Scientific Savant SPD1010 SpeedVac Concentrator With AC-1 Phase Motor
This item was removed from a university laboratory where it was surplus to requirements.
The Savant SPD1010 SpeedVac powers on but encounters issues during operation. The lid fails to lock when a program is initiated, and although the rotor slightly moves, it does not fully run.
The AC-1 Phase motor operates correctly when tested independently but does not power on when connected to the SpeedVac.
Due to these issues, this unit is listed for spares or repair.
Model: SPD1010

£ 500.00 (ex. VAT) 1 in stock
Sanyo Type MDF-U730M Biomedical Freezer Lab
ITEM-44675
Sanyo MDF-U730M Biomedical Freezer Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in good cosmetic condition.
Includes:
6 x Shelves - 62 x 62cm
14 x Containers - 62 x 31 x 16cm

£ 500.00 (ex. VAT) 1 in stock
Sanyo Model MDF-U730M Biomedical Freezer Lab
ITEM-44674
Sanyo MDF-U730M Biomedical Freezer Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in good cosmetic condition.
Includes:
6 x Shelves - 62 x 62cm
14 x Containers - 62 x 31 x 16cm

£ 500.00 (ex. VAT) 1 in stock
Sanyo Model - MDF-U730M Biomedical Freezer Lab
ITEM-44676
Sanyo MDF-U730M Biomedical Freezer Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in good cosmetic condition.
Includes:
6 x Shelves - 62 x 62cm
12 x Containers - 62 x 31 x 16cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific CO2 incubator BB15 Lab Spares/Repairs
ITEM-45101
Thermo Scientific Heraeus CO2 Incubator
This item was removed from a university laboratory where it was surplus to requirements.
It powers on, but the display screen does not activate, and an alarm sounds until the unit is turned off.
Therefore, it is listed as Spares/Repair.
The incubator is in excellent cosmetic condition.
Includes:
- 3 shelves (47 x 43 cm)
- Manuals
- Sample holders
Model: BB15
Serial No.: 40998054
Internal dimensions: D51 W47 H60 cm

£ 500.00 (ex. VAT) 1 in stock
MVE XC 34/18 Nitrogen Dewar Aluminium 34 Litres Capacity
ITEM-42275
MVE XC 34/18 Nitrogen Dewar
This item was removed from a university where it was surplus to requirements.
The dewar is in good cosmetic condition, with signs of use.
Specifications:
- Model: XC 34/18
- Serial No.: ARB97K105
- Capacity: 34 litres
- Neck Opening: 9cm
- Holds: 6 canisters

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Qiagen BioRobot 8000 Liquid Handling System
ITEM-45167
Qiagen Bio Robot 8000
This item was removed from a university lab where it was surplus to requirements.
The system is in good cosmetic condition and powers on.
However, it displays errors during initialization (Z Motor 6: movement blocked, Code:8008 and Z Motor 8: movement blocked, Code:8008), preventing the robot from homing.
The lab reported that all components work except for one or more dilutor units in the syringe pump system, which Qiagen can no longer supply.
Therefore, this system is listed as Spares/Repair.
Included:
- Qiagen Bio Robot 8000
- Dell Control PC running Windows 7 with QIAsoft 4.1.4.5 software (discs included)
- Keyboard, monitor, and mouse
- Pump system
- Box containing various spare parts and consumables

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Qiagen BIOROBOT 8000 Universal Platform Liquid Handling System Lab Spares/Repair
ITEM-46288
Qiagen BIOROBOT 8000 Universal Platform Liquid Handling System
This system was removed from a university laboratory where it was surplus to requirements.
It powers on but has not been tested further at our site.
The previous client has notified us that it is not in working order and that Qiagen no longer supports this instrument.
The system is in good cosmetic condition.
Includes:
- Cupboards/drawers integrated into the stand
- All bottles and solvent traps
- A pump
- 9 x 1100µl tip rack holders
- Multiple miscellaneous plate holders
- Tube holding racks
- Handles for moving the unit
- 4 x 50µl tip rack holders
- 1 pack of Elution Microtubes
- 1 BGR Bottle
- Lubricating oil
- Various QIAsoft 5.0 disks including operating system, protocol packages, and maintenance disks
- Data handbooks
- Manuals

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Revco DXF Model DXF24040V Laboratory Freezer Lab Faulty
ITEM-42305
Thermo Scientific Revco DXF Model DXF24040V Laboratory Freezer
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on. During testing, it failed to reach the set temperature of -40˚C, only cooling down to 7˚C.
Therefore, it is listed as Spares/Repair.
Additionally, three inner door slide catches are missing.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Hera Freeze HFU Series Model HFU40240BV Lab Spares/repairs
ITEM-42306
Thermo Scientific Hera Freeze HFU Series Model HFU40240BV Lab Freezer
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, during testing it failed to cool and remained at ambient temperature when set to -86ºc. Further inspection iden
Therefore, it is listed as Spares/Repair.

£ 500.00 (ex. VAT) 1 in stock
LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab
ITEM-42425
LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab
This item was removed from a university lab where it surplus to requirement.
It is good cosmetic condition and good working order.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Don Whitely MK3 Anaerobic Bench Top Work Station Spares/Repair
ITEM-42468
Don Whitely MK3 Anaerobic Bench Top Work Station
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition but is not in working order, mainly due to a faulty gas inlet valve.
It powers on with functional temperature control and cooling fans. Key issues include non-working internal power sockets, flashing low CO2 and N2 warning lights, and a broken outer door lock seal knob, which compromises the chamber's sealing.
Due to the faults listed above, this system is listed as Spares/Repair.
Features:
- Uses hydrogen, nitrogen, and carbon dioxide or a standard anaerobic gas mixture.
- Digital temperature controller for constant temperature maintenance.
- Humidistat-controlled condensing plate for excess moisture removal.
- 30-litre interchange lock capable of holding 108 plates with vacuum flushing.
Includes:
- User Instruction Manual
Serial No.: 3170S

£ 500.00 (ex. VAT) 1 in stock
Union Carbide Liquified Gas Container Liquid Nitrogen Dewar Lab
ITEM-46190
Union Carbide Liquified Gas Container Dewar
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition, we are unable to test it further at our facility.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Scientific U570 -45 Ultra Low Temperature Freezer Spares/Repairs
ITEM-41126
New Brunswick Scientific U570 -45 Ultra Low Temperature Freezer
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition.
The item powers on but does not drop in temperature, therefore it is sold as Spares or Repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Packard 9200 Hydrogen Generator B920000 Lab Spares/Repairs
ITEM-28161
Packard 9200 Hydrogen Generator
This was removed from a university lab where it was surplus to requirements.
We had the unit looked at by a service engineer. It is fully working but is leaking hydrogen.
It is in reasonably good cosmetic condition, but has some marks from use.
it is sold for spares/repairs

£ 500.00 (ex. VAT) 1 in stock
LEEC Research CO2 Incubator Model GA2000 Lab
ITEM-41593
LEEC Research CO2 Incubator Model-GA2000
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in reasonably good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MCO-20AIC CO2 Incubator Lab Spares/Repairs
ITEM-40000
Sanyo MCO-20AIC CO2
This was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers up, it has been tested with a digital thermometer (not included).
The current CO2 Pump failed during testing and will require a new one to be fitted.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Tuttnauer Vertical Laboratory Autoclave 5050ELV D Steriliser Lab 110L Faulty
ITEM-04932
This Tuttnauer Autoclave 5050ELV-D Steriliser was removed from a university lab where it was surplus to requirements.
The system has been stripped for parts and is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Boxer Steam Sterilising Laboratory Autoclave 400/220L Lab Spares or Repairs
ITEM-18171
This Boxer Steam Sterilising Laboratory Autoclave 400/220L was removed from a university lab where it was surplus to requirements.
The unit has controller issue, the temperature display is faulty, the door mechanism is faulty and we were unable to reset it.
It is in reasonably good cosmetic condition but it has marks from previous use.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter Avanti J-E Centrifuge Lab Spares/Repairs
ITEM-29745
Beckman Coulter Avanti J-E Centrifuge
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has several faults. The unit requires a new board, flash card and cooling system.
It is in good cosmeti condition with minor marks.
It is sold for spares/repairs.

£ 500.00 (ex. VAT) 1 in stock
MAT BioMAT 2 Recirculating Class 2 Microbiological Safety Cabinet
ITEM-31182
MAT Medical Air Technology BioMAT 2 Class 2 Microbiological Safety Cabinet
This was removed from a university lab where it was surplus to requirements.
The item powers on with airflow and UV light working, the white light doesn't work, but it may just be the bulb.
It is in good cosmetic condition with some marks from use.
Cabinet Dimensions - L120 W63 141cm
Frame Dimensions - L112 W60 H84cm
Internal workspace dimensions - D54 W106 H70cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Esco NordicSafe NC2 - 4L8 Class 2 Safety Cabinet - Damaged Base Lab
ITEM-39859
Esco NordicSafe NC2 - 4L8 Class 2 Safety Cabinet
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition, but is listed as Spares/Repair due to damage to the base of the cabinet.
Model: NordicSafe NC2 - 4L8
Serial: NC2-4L8-2013-80689

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Helmer iLF105-GX Freezer Spares/Repair Lab
ITEM-46454
Helmer iLF105-GX Freezer Spares/Repair
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing it was set to its minimum temperature of -20ºc and it failed to cool, instead rising in temperature from ambient.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Miele Professional G 7883 Lab Glassware Washer Spares/Repairs
ITEM-35868
Miele Professional G 7883 Lab Glassware Washer
This item was removed from a university laboratory where it was surplus to requirements.
The unit did not power up during testing and has had the lock and door switch removed. It is sold for spares/repairs.
In good cosmetic condition with minor marks.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Rodwell Ensign 125 Floor Standing Autoclave Spares/Repair Lab
ITEM-42378
Rodwell Ensign 125 Floor Standing Autoclave
This item was removed from a university laboratory where it was surplus to requirements.
Service and condition notes are as follows:
- Unit powered on and lid opened without issue.
- Evidence of the low water probe shorting onto the outside element, causing the machine to heat with low or no water.
- All three heating elements were tested and found to be open circuit.
- Three elements and the low water probe will need to be replaced.
- It is advised that the unit be delivered to a specialist workshop if repair is to be undertaken.
Due to the faults identified, this item is listed as Spares/Repair.
Includes:
- 1 x USB memory stick
- 1 x inner basket
Specifications:
- Model: Ensign 125
- Serial No.: 2405
- Year: 2015
- Chamber dimensions: 46 cm diameter, 72 cm deep

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Wheaton 753684-D 9 Deck R2P Roller Incubator Spares/Repair Lab
ITEM-46315
Wheaton 753684-D 9 Deck R2P Roller Incubator
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonably good cosmetic condition and powers on; however, during testing it took approximately 5 hours to reach 37°C, with a maximum recorded temperature of 57°C despite being set to 60°C.
Internally, it houses a Wheaton Modular Cell Production Roller Apparatus Model 3. The roller mechanism powers on, but the rollers moved very slowly during testing. The speed control dial is missing, and manually adjusting the underlying nut did not improve the speed.
Due to the above issues, this item is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
SG Ultra Clear TUF UV Ultrapure Water System With Permeate Tank Lab
ITEM-41441
SG Ultra Clear TUF UV Ultrapure Water System With Permeate Tank
This system was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
The lab confirmed it was not in working order but were unable to confirm the fault. It is sold for spares/repairs
Included with the system is the following:
- Permeate Tank
- Cartridge Polisher
- P/N- TR-2051
- DI Cartridge
- P/N- TR-2050
- Carbon Pre-Filter
- P/N- TR-2057
- Carbon Pre-Filter (expired)
- P/N- TR-2057
- DI Cartridge (expired)
- P/N- TR-2050
- User Manual

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf Refrigerated Centrifuge 5804 R Lab Spares/Repairs
ITEM-41484
Eppendorf Refrigerated Centrifuge 5804 R Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on, therefore we are unable to test it further, and it is listed as Spares/Repair.
The control board is faulty, and is loose inside the chamber.
There is no rotor.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Buchi Distillation Chiller B-741 Lab
ITEM-41489
Buchi Distillation Chiller B-741 Lab
This item was removed from a university where it was surplus to requirement.
It powers on but is in poor cosmetic condition, we are unable to test it further at our facility.
The unit is sold for spares/repairs as we believe it will need quite a bit of remedial action to get it working properly.
It is missing one of is feet.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs
ITEM-41633
NESLAB Coolflow CTF33 Refrigerated Recirculator Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, although we were unable to set the desired temperature due to a display fault.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Jouan Refrigerated Centrifuge Model - CR412 with 4750RPM Rotor & Inserts Lab
ITEM-41652
Jouan Refrigerated Centrifuge Model - CR412 with 4750RPM Rotor & Inserts Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, when powered on the display reads '0000' and no controls are operable, thus preventing any testing from being conducted.
Therefore, this item is sold as Spares/Repair.

£ 500.00 (ex. VAT) 1 in stock
Laboratory Isolation Table - White Lab
ITEM-41681
Isolation Table - White Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it further at our facility.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Heraeus Instruments Labofuge 400R Function Line Lab Spares/Repairs
ITEM-41702
Heraeus Instruments Labofuge 400R Function Line Lab
This item was removed from a university where it was surplus to requirement.
It is in fairly poor cosmetic condition and powers on, however, due to an issue with the cooling/heating element it did not reach any desired temperature when tested.
Therefore, it is listed as Spares/Repair.
Additionally, it was tested to its maximum speed of 4500RPM, which performed well with no issues.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Miele Professional Dishwasher GG05 Spares/Repairs
ITEM-24741
Miele Professional Dishwasher GG05
This was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested. The inlet pressure is sufficient, the filter has been checked, cleaned and the propeller adjusted but shows an error 404 message which indicates there is an inlet issue.
It is sold for spares/repairs as it needs a new inlet.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Binder KB 240 Refrigerated Incubator Spares/Repair Lab
ITEM-42729
Binder KB 240 Refrigerated Incubator
This item was removed from a facility where it was surplus to requirement.
The unit powers on, and the screen is functional.
However, temperature settings could not be adjusted during testing, and the unit did not rise above ambient temperature when left running.
Therefore, it is listed as Spares/Repair.
Includes:
- Four internal shelves

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MCO-18AIC CO2 Incubator Lab Spares/Repairs
ITEM-39999
Sanyo MCO-18AIC CO2 Incubator
This was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers up, it has been tested with a digital thermometer (not included).
The current CO2 Pump failed during testing and will require a new one to be fitted.
Therefore, it is listed as Spares/Repair.
Features 3 Shelves.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Scientific ULT Freezer Model-U725 -86 Spares/Repair Lab
ITEM-46517
New Brunswick Scientific ULT Freezer Model-U725 -86 Spares/Repair Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing it did not drop in temperature.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Function Line BB15 Co2 Incubator Spares/Repair Lab
ITEM-42723
Thermo Scientific Function Line BB15 CO₂ Incubator
This item was removed from a university laboratory where it was surplus to requirements.
The incubator powers on, and the display and controls respond correctly. During testing, it was set to 37°C and left to run for 24 hours but did not exceed 19.8°C, consistent with the ambient temperature in the listing room.
No further temperature testing or CO₂ function testing was performed.
Due to the issues stated above, this item was listed as Spares/Repair.
Includes:
- Three internal shelves
The door seal and inner door catch are in good condition.
In good clean cosmetic condition with functional controls and display, but unable to confirm heating function due to limited temperature rise.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire Model NU-5510E Incubator Lab Spares/Repairs
ITEM-46173
Nuaire NU-5510E Incubator Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and successfully reached and stabilised at 37ºc, however it failed to reach its maximum temperature of 60ºc.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire NU-5510E Incubator Lab Spares/Repairs
ITEM-46172
Nuaire NU-5510E Incubator Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and successfully reached and stabilised at 37ºc, however it failed to reach its maximum temperature of 60ºc.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Heracell 150i Incubator Lab Spares/Repairs
ITEM-37320
Thermo Scientific Heracell 150i Incubator Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however due to a suspected board fault an error was produced that prevented further testing.
Therefore, it is listed as Spares/Repair.

£ 500.00 (ex. VAT) 1 in stock
Grant FH15 Flow Heater and FC20 Flow Cooler Lab
ITEM-42784
Grant FH15 Flow Heater and FC20 Flow Cooler
This system was removed from a university laboratory where it was surplus to requirements.
The FH15 Flow Heater powered on with the pump running. The heater light illuminated when the set temperature was increased above ambient.
The FC20 Flow Cooler powered on, and both the compressor and fan could be heard operating.
These units do not include a built-in tank and require an external header tank to function as part of a complete system. Due to this, full-range temperature testing was not performed.
It is in good cosmetic condition.
Includes:
- Grant FH15 Flow Heater (Serial No. 72311)
- Grant FC20 Flow Cooler (Serial No. 72311)
- Model: FH15 / FC20
- Serial No.: 72311