Miscellaneous Laboratory Equipment
Items 151 to 200 of 401

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Milestone Ethos plus 2 SEL Microwave Solvent Extraction Labstation Spares/Repair
ITEM-41135
Milestone Ethos plus 2 Microwave Solvent Extraction Labstation
This system was removed from a university where it was surplus to requirement.
All units are in good cosmetic condition, with the primary unit (Milestone Ethos plus 2) and PC Set-Up turning on, however, there is no power in the LabTerminal 800 Controller.
The system is sold for spares/repairs.
-1x Milestone Microwave Laboratory Systems LabTerminal 800 Controller
1x easywave chip card for the controller
S/N- 0205722
-2x Rotor' for microwave
- Relevant vessels and safety shields for rotors
-2x ATC-FO sensors for microwave
-2x Torque wrenches for rotor
-2x Extraction Pipes
1x Monitor (IIyama Prolite B2206WS) and Dell Tower Optiplex GX620
Includes: Pipette tracker v3.3 Software

£ 1,000.00 (ex. VAT) 1 in stock
Varian Cary Fibre Optics Coupler Lab
ITEM-45319
Varian Cary Fibre Optics Coupler
This item was removed from a university lab where it was surplus to requirements.
The item is in good cosmetic condition and is housed in a protective box. Unable to test for operational status.
Includes:
- Phillips screwdriver
- Small spanner
Serial No.: 94081255

NEW ITEM
NEW ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Ace Glass Jacketed Pressure Reaction Vessel 14cm Flange Bottom Outlet
ITEM-36059
Ace Glass Jacketed Pressure Reaction Vessel 14cm Flange Bottom Outlet
This was removed from a university lab where it was surplus to requirements.
The unit is new and shows no signs of use.
The flange at the bottom is 14cm, though there is no suggestion of the volume.

£ 1,000.00 (ex. VAT) 1 in stock
Leybold RPK 3500 Cryo Pump Lab
ITEM-36856
Leybold RPK 3500 Cryo Pump
This item was removed from a university where it was surplus to requirement.
The client notified us that it was working when last used, but it is advised for it to be serviced before use.
All items included in the listing:
Leybold RPK 3500
PN: 891 67
SN: A9006000 01
Leybold RGD 330
PN: 89191
SN: A8906000 28
Leybold REG-Heizung
PN: 892 22
SN: A 89 11 00088

£ 1,000.00 (ex. VAT) 1 in stock
Mutek Infrared Laser System - TLS 150, 0LS150, KMPV50-0.5-J2 Lab
ITEM-37859
Mutek Infrared Laser System - TLS 150, 0LS150, KMPV50-0.5-J2 Lab
The lab confirmed that the system has not been used for 10 years but was working prior to being put away into storage.
Mutek Infrared Laser System
The Item Powers on and is in Good Condition with Some Wear
Model - 0LS150
Mutek Infrared TLS 150
Model - TLS 150
Kolmar Technologies Infrared Detector
Model - KMPV50-0.5-J2
Kolmar Technologies Infrared Detector PSU
Has no Information Plate

£ 1,000.00 (ex. VAT) 1 in stock
DakoCytomation Diode Lyt 200-S Laser Head w/ Controller & Fan/Cooler Lab
ITEM-41212
DakoCytomation Diode Lyt 200-S Laser Head w/ Controller & Fan/Cooler
This was removed from a working MoFlo system. It was surplus to requirements.
The unit powers up but has not been tested further due to safety restrictions around lasers at our site.
It is in good cosmetic condition with minor marks.

£ 1,000.00 (ex. VAT) 1 in stock
Minebea Intec Combics 2 Model-CAW2S1-30ED-I Weighing Scale Lab
ITEM-44659
Minebea Intec Combics 2 CAW2S1-30ED-I Weighing Scale Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and is in good working order. (Calibration weights are not included)
Model - CAW2S1-30ED-I
S/N -35566690

£ 1,000.00 (ex. VAT) 1 in stock
150 x Trays of Cuvettes and Cuvette Holders - 14400 Total Lab
ITEM-38740
150 x Trays of Cuvettes and Cuvette Holders - 14400 Total Lab
These items were removed from a working lab where they were surplus to requirements.
All items are brand new and sealed in their original packaging.
Total number of Trays: 150
Each Tray contains 96 cuvettes.
Total number of cuvettes 14,400

£ 1,000.00 (ex. VAT) 1 in stock
Minebea Intec Combics 2 CAW2S1-30ED-I Explosion Proof Weighing Scale Lab
ITEM-44657
Minebea Intec Combics 2 CAW2S1-30ED-I Weighing Scale Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and is in good working order. (Calibration weights are not included)
Model - CAW2S1-30ED-I
S/N -35566690

£ 1,000.00 (ex. VAT) 1 in stock
CVI Melles Griot 05-LHP-928 Laser Head w/ Controller Lab
ITEM-41206
CVI Melles Griot 05-LHP-928 Laser Head w/ Controller Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
CVI Melles Griot 25-LHP-928-230 Laser Controller
Model: 25-LHP-928-230
CVI Melles Griot 05-LHP-928 Laser Head
Model: 05-LHP-928

£ 1,000.00 (ex. VAT) 1 in stock
Laser Optics Tropel EFL 33.91mm F/8.70 Precision Optical Lens
ITEM-46393
Laser Optics Tropel EFL 33.91mm F/8.70
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it at our facility.

£ 1,000.00 (ex. VAT) 1 in stock
Waters 70001117 High Temperature Dual Ion Guide Assembly Lab
ITEM-38451
This Waters 70001117 High-Temperature Dual Ion Guide Assembly was removed from a university lab where it was surplus to requirements.
The item is in good cosmetic condition but due to the power supply not being included, we are unable to test, therefore the item is sold as Spares or Repairs.
Power supply not included.

£ 1,000.00 (ex. VAT) 2 in stock
Servomex Analyser Series 1400 CO2 Analyser Lab
ITEM-35073
Servomex Analyser Series 1400 CO2 Analyser
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
It is in good cosmetic condition with minor marks from use.
Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving upon purchase before it is shipped, we would be happy to provide this.

£ 1,000.00 (ex. VAT) 1 in stock
Emtek P100 Microbial Air Sampler Lab
ITEM-41780
Emtek P100 Microbial Air Sampler Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, we are unable to test it further at our facility.
As seen, there is damage sustained to the display screen, however, it does not impact its functionality.
The Unit comes with a case, 18V Charger and a Remote

£ 1,000.00 (ex. VAT) 1 in stock
6 x Leica Biosystems Bond Polymer Refine Detection DS9800 (EXP 2025-04-30)
ITEM-46241
6 x Leica Biosystems Bond Polymer Refine Detection DS9800
These items were removed from a facility where they were surplus to requirement.
Included are 6 x Leica Biosystem Bond Polymer Refine Detection devices, all of which are sealed and in their original packaging.
- Lot Number: 77422
- Reference: DS9800
- Expiration Date: 2025-04-30

£ 1,000.00 (ex. VAT) 1 in stock
Soxtec Avanti 2050 Auto Fat Extraction System with Drive Unit Lab
ITEM-24537
This Soxtec Avanti 2050 Auto Fat Extraction System was removed from a university lab where it was surplus to requirements.
Included are;
1 x Foss Tecator 2050 Soxtec Avanti Auto Extraction Unit
Part no. 10007330
1 x Foss Tecator 2050 Drive Unit
Part no. 10007338
The item powers on with the drive unit supplying power and controlling the extraction unit. It was not tested further. It seems to be missing a control unit.
The item is in reasonably good cosmetic condition with some marks from use.

£ 1,000.00 (ex. VAT) 1 in stock
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories Lab
ITEM-24618
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories
This was removed from a university lab where it was surplus to requirements.
The system consists of;
1 x Echo HiVol Hi Volume Sampler
Model, Echo Hi Vol
110V
The unit powers on and is in good cosmetic condition. It was powered on by our Step down from the mains supply (not included).
The buttons seem a little slow to respond and there are some tape marks and scuffs and scratches around the unit from general use. The unit is lockable but no key is supplied. The key is included.
1 x Delta Wireless Sampler
Electronic Flow Sampler w/ Battery pack
Model Delta
110V
The unit powers on and is in good cosmetic condition. We did not charge Battery to test, as we used our Step down from the mains supply. (not included).
1 x Delta Battery pack
The unit is in good cosmetic condition. It was not tested.
2 x Flight Casea
3x Marigold gloves (size 9)
1x Spanner (size 10)
2x fuses T6.3AL 250V
4X keys
1x Widget H045
1x TCR Fine PM Air Inlet PM 2.5 200l/min
1x Metal Filter attachment
2x Glass chambers
1x Metal Dome
3x Sanitising spray
2x TCR TECORA plastic sample trays (3cm diameter)
6x Sample dishes with lids (14cm diameter)
4x Glass condensers 1x opened 3x factory sealed
1x Delta quick guide
2x Boxes of Microfibre Discs (1x opened 102mm Dia) quantity unknown
(1x sealed 100 Dia) quantity 100
1x Flurescein Green Concentrate (bottle partially full, sealed inside a bag it has leaked at some point.
1x Air pollution monitoring equipment (Metal chamber with hose)
1 x manual
1 x TCR Tecora TCR Downloader for Echo Series, Delta & Bravo Plus.
There is also a software disk included with this but it is entirely in Italian.

£ 980.00 (ex. VAT) 1 in stock
Tecan Freedom EVO-2 100 Base Software
ITEM-26381
Tecan Freedom EVO-2 100 Base Software
This was removed from a university lab where it was surplus to requirements.
Contains the following:
Tecan Instrument Software Version 6.1 SP1
Operating Manual Freedom EVO
Swiss Tools PB 6205: 0.71 x 40
Swiss Tools PB 140/2 : 0.6 x 4 x 40
Mini flat head screw driver
Allen key tool

NEW ITEM
NEW ITEM
£ 955.00 (ex. VAT) 1 in stock
Micromass Capillary CE Assy Kit M955420CC1-S for Waters Xevo Lab
ITEM-31722
Micromass Capillary CE Assy Kit M955420CC1-S
This was removed from a university lab where it was surplus to requirements.
Everything is boxed and the consumables are sealed.
Included are;
Micromass Capillary Electrophoresis/Electrochromatography Sprayer Users Guide
Parts:-
Probe Cover M955510BD1
C.E HV Cable Assy M955515BC1
Earth Tag M955514AD1
Capillary M955423BD1
C.E Assembly Spares Kit M955420CC4:-
Cable Clamp M955513AD1
Plug Cap - Valco ZC1 6070233
1/16 Valco Ferrule 6070135
Ingertight Nut - Anachem F125 6070186
Circlip 6364907
Capillary M955423BD1
1.15 I/D x 1.00 C/S O-Ring 5711945
M2 Plain Washer 5331014
Alltech Peek Union 32141 6367402
1/4 - 1/16 Union 6070235
M3 x 4 ST/STL Grub Screw 5316005
1/16 Valco ZN1 Nut 6060806
Ceramic Capillary Cutter 6028630
Special Screw M955370AD1
Fill Port 6060919
Liner - Anachem F182X 6072209
Liner - Anachem F185X 6072210
1/8 - 1/16 PTFE Ferrule T1640357
M2 x 6 ST/STL CH HD Screw 5314050
BS109 Viton O-Ring 5711061
Upchurch F300 Nut & Ferrule 6367401
Microlight Union - Anachem P7 6072208
Fused Silica - TSP050192 6490519
PTFE Tube - TTF110 6063002
Fused Silica - TSP075375 6490512
Fused Silica - TSP075200 6490520
PTFE Tube - TTF115 6060743
Peek Tube - Orange 0.020 Bore 6436002
1/16 x 1mm Bore PTFE Tube 6430206

£ 950.00 (ex. VAT) 1 in stock
Coherent Enterprise Laser Head & Coherent Laserpure 5 Chiller Lab
ITEM-39743
Coherent Enterprise Laser Head & Coherent Laserpure 5 Chiller
This system was removed from a university lab where it was surplus to requirements.
The units both power up but have not been tested further. They are in good cosmetic condition with marks from use.
Included are;
Coherent Enterprise Laser Head Power Supply
Model: ENTCII-653
Serial#: 020775654-ENIC
Manu: July, 2002
Coherent Laserpure 5 Heat Exchanger water-to-water Laser Cooling System
Model: LP-51
Serial#: 17772
Manu: 13 May, 2002

£ 900.00 (ex. VAT) 1 in stock
Chemspeed ASW 2000 Automated Synthesis Workstation Lab
ITEM-36660
Chemspeed ASW 2000 Automated Synthesis Workstation
This was removed from a university lab where it was surplus to requirements.
The unit powers up but the control PC has no hard drive. We have left the PC with the unit just in case it has any interface cards that may be useful.
Included are;
1 x Chemspeed ASW 2000
Power Supply
SN - ASW2000 JC0001
Powers on
Edmond Buhler Vortex Control Unit
Type - TiMix 6 Control
SN - 6164 MS 00188
Powers up with intensity dial running up to 1400rpm
Gilson Syringe Pump
SN - 640A3D024
Powers on
Gilson Autosampler
SN - 270J5XE332
Powers on
Gilson unit - PN - U20655E - Powers on
5 x Chemspeed Cases marked ASW 1-5 containing parts:-
ASW 1 - PN - 18917 & 648T032
ASW 2 - PN - 648T032
ASW 3 - PN - U20173K & 648T032
ASW 4 - PN - W20223F
ASW 5 - PN - W20218F & 648T032
Fujitsu Siemens PC - No HDD.
Dell 17" Monitor
HP Keyboard
Labtec Mouse
Chevron LEV Monitor
SN - 001288
1 x manual

£ 900.00 (ex. VAT) 1 in stock
Biotest APC M3 P52100S Airborne Particle Counter and APC Plus 943201
ITEM-38320
Biotest APC M3 P52100S Airborne Particle Counter and APC Plus 943201
These items were removed from a university where they were surplus to requirement.
Both items are in good cosmetic condition and power up, we are unable to test them further at our facility.
The following items are included:
APC M3
Model P52100S
Serial No. F0708-010310
Year 2008
APC Plus
Model 943201
Serial No. B0408-2275
Year 2008
Boxer Custom Case
Serial No. 13665
External 44cm x 52cm x 39cm
Internal 39cm x 47cm x 20cm
Accessories included:
1 x power lead
1 x 7-volt power transformer supply lead
1 x stainless suction cup with 1 meter hose

£ 895.00 (ex. VAT) 1 in stock
Becton Dickinson Mixer Controller Panel Lab
ITEM-18701
Becton Dickinson Mixer Controller Panel
This was removed from a university lab where it was surplus to requirements.
The unit is untested.

£ 880.00 (ex. VAT) 1 in stock
Dolomite Mitos P-Pump System w/ Remote Chamber + Flow Rate Sensor
ITEM-35912
Dolomite Mitos P-Pump System With Remote Chamber 400 + Flow Rate Sensor
This was removed from a university lab where it was surplus plus to requirements.
All units power up but have not been tested further.
It is in reasonably good cosmetic condition with minor marks from use.
Includes:
-Dolomite Mitos P-Pump
-Dolomite Mitos Remote Chamber 400
-Dolomite Mitos Sensor Interface
-Dolomite Mitos Flow Rate Sensor
-P-Pump user manual
P-Pump model number- 3200016_4
P-Pump serial number- 1600682
Chamber serial number- 1600843
Sensor serial number- 160880

£ 875.00 (ex. VAT) 1 in stock
Applied Biosystems MDS SCIEX QStar System Software Analyst® QS Metabolite ID
ITEM-28122
Applied Biosystems MDS SCIEX QStar System Software
This was removed from a university lab where it was surplus to requirements.
Included are the following:
1x Analyst® QS 1.1 Software
P/N 1012847
1x Metabolite ID 1.3 for Analyst® QS 1.1 Software
P/N 1012866
1x Analyst QS 1.1 Software Validation Certificate
Dated 03/12/2004
1x Metabolite ID 1.3 for Analyst® QS 1.1 Validation Certificate
Dated 03/12/2004.
2x Copies of License Agreement for Analyst® QS 1.1 Software
1x Metabolite ID 1.3 for Analyst® QS 1.1 Software Release Notes

£ 875.00 (ex. VAT) 1 in stock
Dolomite Mitos P-Pump System With Remote Chamber 400 + Flow Rate Sensor
ITEM-35899
Dolomite Mitos P-Pump System With Remote Chamber 400 + Flow Rate Sensor
This was removed from a university lab where it was surplus plus to requirements.
All units power up but have not been tested further.
It is in reasonably good cosmetic condition with minor marks from use.
Included are;
Includes:
-Dolomite Mitos P-Pump
-Dolomite Mitos Remote Chamber 400
-Dolomite Mitos Sensor Interface
-Dolomite Mitos Flow Rate Sensor
-P-Pump user manual
-Remote chamber 400 manual
-Sensor manual
P-Pump model number- 3200016_4
P-Pump serial number- 1600680
Chamber serial number- 490174u7
Sensor serial number- 4903648

NEW ITEM
NEW ITEM
£ 875.00 (ex. VAT) 1 in stock
63 x Various Sized Pall Allegro 2D Biocontainer Systems Advantaflex Tubing
ITEM-38732
63 x Various Sized Pall Allegro 2D Biocontainer Systems Advantaflex Tubing
These were removed from a working lab. They were surplus to requirements.
All items are brand new and sealed in their original packaging.
Included are the following:
Pall 2D bicontainer system 619-31C
Volume: 50 L
Qty: 3
Pall 2D bicontainer system 650-202G
Volume: 250 mL
Qty: 6
Pall 2D bicontainer system 650-202L
Volume: 1 L
Qty: 13
Pall 2D bicontainer system 650-202H
Volume: 500 mL
Qty: 8
Pall 2D bicontainer system 650-202K
Volume: 1 L
Qty: 13
Pall 2D bicontainer system 650-2020D
Volume: 100 mL
Qty: 20

£ 850.00 (ex. VAT) 1 in stock
Airsep Topaz Oxygen Generator AS013-106 Lab
ITEM-42402
Airsep Topaz Oxygen Generator AS013-106
This item was removed from a university lab where it was surplus to requirement.
It is in excellent condition and powers on, we are unable to test it further at our facility.
Specifications;
- Model: Topaz (6)
- Serial No.: 2856616-3
- Year: 2020

£ 830.00 (ex. VAT) 2 in stock
HaB Douglas Bag Cart Systems 100 L Plus Dry Gas Meter Lab
ITEM-35689
HaB Douglas Bag Cart Systems 100 L Plus Dry Gas Meter
This was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition but has not been tested.
Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving upon purchase before it is shipped, we would be happy to provide this.

£ 820.00 (ex. VAT) 1 in stock
Improvision Phylum Imaging Software Version 1.4.4 Lab
ITEM-32088
Improvision Phylum Imaging Software Version 1.4.4
This was removed from a university lab where it was surplus to requirements.
The software was downloaded onto the PC without issue, it will need a product unlock code to make it operational, which is supplied on the back of the CD case.

£ 820.00 (ex. VAT) 1 in stock
Irori AccuTag 100 Scanning Station Model: At-100-CS-CE Lab
ITEM-24838
This Irori AccuTag 100 Scanning Station Model: At-100-CS-CE was removed from a university lab where it was surplus to requirements.
The item is in reasonable cosmetic condition. There are scratches/dents on the surface, along with stains. The accessories have been used and thus have broken seals.
The item was plugged in, but there wasn't any clear indication it had powered on. We were unable to test it further without a PC connection.
Also included are the following:
1x AccuTag Synthesis Manager Version 1.0
1x AccuTag Synthesis Manager Version 2.26
12x Irori Radio Frequency Tag
1x PSU
1x DE-9 cable

NEW ITEM
NEW ITEM
£ 810.00 (ex. VAT) 10 in stock
129,600 ClipTips - 50 ul, Thermo Scientific Filtered, Sterile, Racked/96
ITEM-35422
129,600 ClipTips - 50 ul, Thermo Scientific Filtered, Sterile, Racked/96
These are sold on behalf of a client.
The lot is brand new and unused.
Quantity - Pallet of 27 boxes. 10 Racks in 1 Pack, 5 Packs in 1 Box.
Make/Brand - Thermo Scientific
Model Number - 94420253
Product Number - 13246269
Exp Date - 2025/2026
SKU - TIP-50FS-THE
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

£ 810.00 (ex. VAT) 1 in stock
CTC Analytics Leap HTC PAL Autosampler HPLC Chromatography Lab
ITEM-37703
This CTC Analytics Leap HTC PAL Autosampler HPLC was removed from a university lab where it was surplus to requirements.
All units are in good cosmetic condition and powered up.
We are unable to test the system further at our facility.
Autosampler consists of:
Autosampler main unit MXY 01-01B
Serial No. 113399
Power supply unit MN01-00
Injector unit MZ01-00D
Serial No. 980
Control key pad/screen MB 01-00A
2 x pumps MV 02-01A
Serial Nos. 2961, 2963
Sample tray 3 drawer storage MP 02-00B
Needle wash unit
Bottle shelf

£ 800.00 (ex. VAT) 1 in stock
Parr Hydrogenation Apparatus Model 3921 Lab
ITEM-46441
Parr Hydrogenation Apparatus Model-3921
This item was removed from a facility where it was surplus to requirements.
It powers on and is in reasonably good cosmetic condition, with some visible rust and chipped paint.
During testing, the apparatus powered on successfully with a fully functional pump and motor strut that facilitates shaking. Further testing was not conducted.

£ 800.00 (ex. VAT) 1 in stock
CTC Analytics Leap HTC PAL Autosampler Heating and Cooling HPLC Lab
ITEM-37702
This CTC Analytics Leap HTC PAL Autosampler Heating and Cooling HPLC was removed from a university lab where it was surplus to requirements.
All units are in good cosmetic condition and powered up.
The CTC Analytics Leap HTC PAL Autosampler was tested with a digital thermometer (not included).
We are unable to test further at our facility.
Autosampler consists of:
CTC Analytics main unit MXY 01-01B
Serial No. 113351
CTC Analytics Injector Column MZ01-00D
Serial No. 1284
2 x CTC Analytics Pumps MZ01-00D
Serial Nos. 3022, 3216
Supercool Box27 sample tray heating and cooling 3 x drawers 20cm x 12cm
Serial No. CCO-00103
CCT Analytics Peltier Thermostat unit MN 03-02
CCT Analytics Power Supply MN01-00
CCT Control Pad and Screen MB 01-00A
Needle wash unit
Included:
4 x power leads
1 x data cable
Solvent shelf with 1 litre glass Scott Duran bottle

£ 800.00 (ex. VAT) 1 in stock
Advanced ChemTech Model 90 Peptide Synthesiser 90-CE Lab
ITEM-37387
Advanced ChemTech Model-90 Peptide Synthesis
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.

£ 750.00 (ex. VAT) 1 in stock
Coherent Sapphire Controller with Sapphire 561-100 Laser Head Lab
ITEM-41215
Coherent Sapphire Controller with Sapphire 561 Laser Head Lab
These items were removed from a university where they were surplus to requirement.
Both the laser head and controller are in good cosmetic condition. The controller powers on, but we cannot test the laser as the connecting cable from the controller is not supplied.
Coherent Sapphire Controller
Model: Sapphire LP USB CDRH driver unit w/ display
Sapphire 561 laser head.
Model: SAPPHIRE 561-100 CW CDRH
Data cable not included.

£ 750.00 (ex. VAT) 1 in stock
Perkin Elmer Fluorescence 204 Spectrophotometer Analyser Laboratory Equipment
ITEM-06749
This was removed from a university lab where it was surplus to requirements
The unit powers up but has not been tested further.
It is in reasonably good cosmetic condition with minor marks.

£ 750.00 (ex. VAT) 1 in stock
43 x Illumina HiSeq Reagent Racks - Mixed Sizes Lab
ITEM-40998
43 x Illumina HiSeq Reagent Racks - Mixed Sizes
These were removed from a university lab where they were surplus to requirements.
The units are in good cosmetic condition with minor marks.
Included are;
24 x Racks that hold 8 x 6cm diameter tubes
19 x Racks that hold 20 x 12ml tubes

£ 750.00 (ex. VAT) 1 in stock
Surgipath Medical 04502GFS-240 Premier Cooling Plate Lab
ITEM-39973
This Surgipath Medical 04502GFS-240 Premier Cooling Plate was removed from a university lab where it was surplus to requirements.
The item powers on and is in a reasonably used cosmetic condition.
It is in good cosmetic condition.
Work platform cooled to: –10ºc

£ 750.00 (ex. VAT) 1 in stock
Thermo Scientific 8-Channel Decapper With Stand Lab
ITEM-45243
Thermo Scientific 8-Channel Decapper with Stand
This item was removed from a university where it was surplus to requirements.
The unit is in good cosmetic condition, powers on, and is fully operational.
Specifications:
- Model: 8-Channel Decapper

£ 750.00 (ex. VAT) 1 in stock
EG&G Polarographic Analyzer System Model 384B with 303A Dropping Electrode Lab
ITEM-27766
EG&G Polarographic Analyzer System Model 384B with 303A Dropping Electrode
These were removed from a university lab where they were surplus to requirements.
Both units have been powered up but we were unable to test them further at our facility.
Included are;
1x EG&G Polarographic Analyzer
Model 384B
The unit powers on and is in good cosmetic condition. 'BLANK SWV' appeared on the screen after the analyser had powered up. None of the buttons appeared responsive.
1x EG&G Stating Mercury Dropping Electrode (SMDE, DME, HMDE)
Model 303A
The unit powers on and is in good cosmetic condition. We were unable to test it.
Accessories:
1x EG&G Operating Diskette
Revision: F0
The unit is in good cosmetic condition. The diskette goes into the back of the polargraphic analyser in the disk drive. 'BLANK SWV' appeared on the screen after the analyser had powered up.
1x EG&G Polargraphic Analyzer user manual
1x EG&G Stirrer
Model 305
The unit powers on via the SMDE and is in good cosmetic condition.
The stirrer works in MANUAL mode, and both the slow and fast speeds are working. We could not get the stirrer to work in AUTO mode.
2x Ametek Data Disk
Model 394
Rev 2.01
The units are in good cosmetic condition, they are not compatible with the unit. more likely for a PC,
7x 25ml Glass cups
The units are in good cosmetic condition
5x 50ml Glass cups
The units are in good cosmetic condition.
1x Ribbon cables RS232
The unit is in good cosmetic condition
1x Cell compartment controller cable
The unit is in good cosmetic condition,
it provides power from the 384B Analyser to the 303A SMDE

£ 720.00 (ex. VAT) 1 in stock
Jobin Yvon Spex Spectrum One Liquid Nitrogen Detector Head
ITEM-35552
Jobin Yvon Spex Spectrum One Liquid Nitrogen Detector Head
This was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition with minor marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 700.00 (ex. VAT) 1 in stock
Packard Tri-Carb 2100TR Liquid Scintillation Analyser (No Source) Lab
ITEM-42467
Packard Tri-Carb 2100TR Liquid Scintillation Analyser, ViewSonic Monitor, Epson LQ-350 Printer, and IBM Keyboard
This system was removed from a university lab where it was surplus to requirement.
The radioactive source from the Tri-Carb 2100TR was removed before it left its previous workplace.
The previous owner stated it was in working order prior to removal, however the Tri-Carb 2100TR could not be fully tested due to internal issues, including loose components and disconnected electrical cables found after removing the front panel.
Due to this, it will require recommission and is therefore listed as Spares/Repair, though it was confirmed as working before the source was removed.
Included Equipment:
- Packard Tri-Carb 2100TR Liquid Scintillation AnalyserModel: A2100
- Serial No.: 406445
- Serial No.: RQK111800366
- Year: 2011
- Epson LQ-350 PrinterModel: PA81A
- Serial No.: R9By022952
- IBM KeyboardModel: RT3100 V:5NTWUK
- Serial No.: 82490922
Included Accessories:
- 69 x sample holder racks with 18 small sample positions.
- 31 x sample holder racks with 12 large sample positions.
- 41 x Protocol Plugs Part No. 7000675.
- 2 x packets of rack labels.
Manuals:
- 1 x Tri-Carb Models 2100TR/2300TR Operation Manual.
- 1 x Tri-Carb 2000 Series Operation Manual.
- 1 x Epson LQ-300+II Printer Setup Guide.
- 1 x set of Tri-Carb Performance Certificates.
- 1 x DOS 3.30 User Guide.
- 1 x DOS 3.30 Reference (Abridged) User Guide.
Software:
- 1 x IBM DOS 3.30 on 3.5" and 5.25" diskettes (may be incomplete).
- 1 x set of 9 Tri-Carb A2100TR 3.5" Install Discs.
- 1 x Epson LQ-300+II Software CD-ROM Disc vol 2.1.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 700.00 (ex. VAT) 1 in stock
Autoclave Engineers Model 300mL EZ Seal w/ Control Tower Lab
ITEM-37161
Autoclave Engineers Model 300mL EZ Seal w/ Control Tower Lab
This system was removed from a university where it was surplus to requirements.
Both units are in good cosmetic condition, however, they have not been tested beyond that due to the system being a visual PAT fail, it is being sold for Spares or Repair.
Includes the following;
1x Autoclave Engineers unit
Model: E010HM0210C112B200121E2101
1x Control tower
Model: C1211224300010C

£ 700.00 (ex. VAT) 1 in stock
MSE Mark No2 Consolidation Testing System Controlled Rate of Strain 2726 Lab
ITEM-44393
MSE Mark No2 Consolidation Testing System Controlled Rate of Strain 2726
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it further at our facility.

£ 700.00 (ex. VAT) 1 in stock
Perkin Elmer Sample Pan Press Lab
ITEM-44704
Perkin Elmer Universal Crimper Press Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and in good mechanical order.

£ 700.00 (ex. VAT) 1 in stock
Surgipath 04501GFS-240 Premier Dispensing Console Lab
ITEM-39972
This Surgipath 04501GFS-240 Premier Dispensing Console was removed from a university lab where it was surplus to requirements.
The item powers on and is in a reasonably used cosmetic condition.
All compartments successfully heat independently as displayed on the screen, unable to test further at our facility.

£ 700.00 (ex. VAT) 1 in stock
Gartner Scientific Corporation L117 Elipsometer Lab
ITEM-45320
Gartner Scientific Corporation L117 Ellipsometer
This item was removed from a university lab where it was surplus to requirements.
The ellipsometer is in fair cosmetic condition, with some wear consistent with its age. The device includes a Class 3 laser product and, for safety reasons, it was not powered on.
One of the axis arms for moving the stage is broken.
Includes:
- On/off key
Specifications:
Model: L117
Serial No.: 449-AK
Laser Model: 7222H-PC
Laser Serial No.: 1310241

£ 700.00 (ex. VAT) 1 in stock
Hewlett Packard / Agilent 1100 Series HPLC G1313A Autosampler Lab
ITEM-38346
This Hewlett Packard / Agilent 1100 Series HPLC G1313A Autosampler was removed from a university lab where it was surplus to requirements.
The item is in good cosmetic condition and powered up.
When powered up, the item ran a start-up self-test that displayed the motor in good working order, we are unable to test this item further at our facility.
Items 151 to 200 of 401