All Products
Items 1801 to 1850 of 2710

NEW ITEM
NEW ITEM
£ 535.00 (ex. VAT) 1 in stock
17 Boxes of Mixed FisherBrand SureOne Pipet Tips Non filter + Aerosol Barrier
ITEM-35501
17 Boxes of Mixed FisherBrand SureOne Pipet Tips Non filter + Aerosol Barrier
Individually sealed and brand new.
10 packs of 96 tips per box amounting to 960 tips per box
Sizes are as follows:
100µl- 5 boxes (4800 tips)
300µl- 3 boxes (2880 tips)
10µl- 3 boxes (2880 tips)
200µl- 1 box (960 tips)
20µl- 2 boxes (1920 tips)
1000µl -3 boxes (2880 tips)
Also individually theres an additional:
10µl- 3 packs (288 tips)
20µl- 3 packs (288 tips)
200µl- 3 packs (288 tips)
100µl- 6 packs (576 tips)
300µl- 5 packs (480 tips)
Mixed expiry dates between 2026-2028

NEW ITEM
NEW ITEM
£ 535.00 (ex. VAT) 1 in stock
264 x Laboratory Trousers & Tunics - Pool Undersuits Lab
ITEM-36184
264 x Laboratory Trousers & Tunics - Pool Undersuits
All items are brand new in their original packaging.
Lab Trousers
Sizes are as follows:
4 - 55
6 - 77
8 - 88
10 - 22
11 - 22
Lab Tunic
Sizes are as follows:
100 - 55
108 - 77
116 - 88
124 - 22
140 - 22

£ 525.00 (ex. VAT) 1 in stock
Leitz Laborlux S Microscope Type 020-505.030 w/ Camera Mount & 3 x Objectives
ITEM-47269
Leitz Laborlux S Microscope Type 020-505.030 w/ Camera Mount & 3 x Objectives
This item was removed from a facility where it was surplus to requirement.
The unit powers up and is in good working order and good cosmetic condition.
Includes:
- 1 x Camera fitting 0.63x: 1/2" 12.7 / 2/3" 17.5 (541007)
- 2 x Eye Pieces – Leica Periplan 10x / 18 (519 748)
- 3 x Objectives:
- 160/- EF 10/0.25 (519760)
- *160/- PL FLUOTAR 50/1.00 OIL (518044)
- *160/0.17 PL FLUOTAR 100/1.32 OIL (519847)

£ 520.00 (ex. VAT) 1 in stock
Roche Reflotron Plus Dry Chemistry Analyser Lab
ITEM-24198
This Roche Reflotron Plus Dry Chemistry Analyser was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
It is in good cosmetic condition with some fairly minor marks from use.

£ 520.00 (ex. VAT) 1 in stock
2 x Rheodyne MX Series Port Selector Valves - MXX778-605 MXP9900-000 Lab
ITEM-31780
2 x Rheodyne MX Series Port Selector Valves
These were removed from a university lab where they were surplus to requirements.
Both units power up but we were unable to test them further at our facility.
They are in good cosmetic condition with minor marks from use.
Included are;
1x Rheodyne MXX778-605
S/N 1565
1x Rheodyne MXP9900-000
S/N 1947
1x AC Adaptor Power Supply
Model TR45A24 26A03
S/N 45240-0026102
Input: 100-240V~1.5A 50-60Hz
Output: 24V - 1.88A
1x AC Adaptor Power Supply
Model TR45A24 26A03
S/N 45240-0018963
Input: 100-240V~1.5A 50-60Hz
Output: 24V - 1.88A

£ 510.00 (ex. VAT) 1 in stock
Panasonic Model Type AW-HE60 CCTV Cameras
ITEM-37270
Panasonic AW-HE50 CCTV Cameras
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers on.
The previous client has stated it was in full working order prior to removal.
This item was tested with an in-house power supply cable. (not included.)

£ 510.00 (ex. VAT) 1 in stock
Jobin Yvon Horiba CCD-3500V Detection Unit Lab
ITEM-35891
Jobin Yvon Horiba CCD-3500V Detection Unit
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in good cosmetic condition with minor marks.

£ 510.00 (ex. VAT) 1 in stock
Thermo Scientific Model Compact LidPark P00155 Lab
ITEM-37179
Thermo Scientific Compact LidPark P00155
This item was removed from a university where it was surplus to requirement.
It is in very good cosmetic condition and powers up, we are unable to test it further at our facility.
Model: LidPark P00155

£ 510.00 (ex. VAT) 1 in stock
Purite Select Purification System L300150 with Storage Tank Lab
ITEM-35809
Purite Select Purification System L300150 with Storage Tank
This was removed from a university lab where it was surplus to requirements.
The system powers up and pressurises but was not tested further.
It is in reasonable cosmetic condition with marks from use.
Both filters, Pretreat 8 and Puripac PP8 expired 15/02/23
100L Storage Tank

£ 510.00 (ex. VAT) 1 in stock
Triple Red Model Duo Organic 60 Ultra Pure Water Purification System Lab
ITEM-45398
Triple Red Duo Organic 60 Ultra Pure Water Purification System
This item was removed from a university where it was surplus to requirements.
The item is in good cosmetic condition and powers on. However, we were unable to perform further testing at our facilities.
Please note: The power supply is not included. Testing was carried out using a power supply from another unit.
Included Components:
- Avidity Carbon Pre-Filter
- P/N: TR-2057
- Install Date: 26/7/23
- Avidity Cartridge Pack
- P/N: TR-2050
- Install Date: 26/7/23
- Avidity Cartridge Polisher
- P/N: TR-2051
- Install Date: 26/7/23
Specifications:
- Model: Organic 60 Ultra Pure Water Purification System
- Serial No.: Not provided

£ 505.00 (ex. VAT) 1 in stock
Hybaid Maxi 14 Hybridisation Oven Lab
ITEM-26176
Hybaid Maxi 14 Hybridisation Oven
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order, but may need calibrating to your equipment. It was tested with a digital thermometer (not included).
It is in good cosmetic condition with minor marks.
Internal Dimensions - D34 W34 H50cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 505.00 (ex. VAT) 1 in stock
Airwolf 3D NW3D HDX 3-D Printer Lab Spares/Repairs
ITEM-37979
Airwolf 3D NW3D HDX 3-D Printer Lab
This item was removed from a university where it was surplus to requirement.
The back panel is missing and, the wires are exposed, resulting in a visual PAT fail.
Due to the condition stated above, this item is listed as Spares/Repair.
Also included are the following:
- Power lead
- Data cable

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Climacell CLC-B2V-M / CLC 111-TV Cooling Incubator - Spares/Repair Lab
ITEM-36470
Climacell CLC-B2V-M / CLC 111-TV Cooling Incubator
This item was removed from a working laboratory where it was surplus to requirements.
The unit powers up but triggers an “Error 5 – safety thermostat setting”. The safety thermostat is factory set between -5°C and 130°C and cannot be adjusted without a chip card, which is not included. The cause may be a hardware fault, as noted in the manual.
Therefore, it is listed as Spares/Repair.
The unit is in good overall cosmetic condition, with a bent handle and a damaged corner.
Includes:
Power cable

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Typhoon Trio+ Variable Mode Imager Spares/Repair Lab
ITEM-37335
Typhoon Trio+ Variable Mode Imager
This item was removed from a university lab where it was surplus to requirement.
It has not been tested due to exposed wiring, and is sold as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Molecular Dynamics Typhoon Trio Internal Components Spare Parts From 2 Machines
ITEM-37478
Molecular Dynamics Typhoon Trio Internal Components – Spare Parts from 2 Machines
These items were removed from university laboratories where they were surplus to requirements.
This listing includes internal components from two Molecular Dynamics Typhoon Trio Imagers. The systems are not complete: one internal is missing the main circuit boards, while the other is missing the laser source.
Additional components may also be missing. Cables have been cut.
Includes:
- Melles Griot Laser Class 3B
- Model: 85-BCB-020-049
- Serial No.: 1447K
- Year: 2008

£ 500.00 (ex. VAT) 1 in stock
Grant FH15 Flow Heater and FC20 Flow Cooler Lab
ITEM-42784
Grant FH15 Flow Heater and FC20 Flow Cooler
This system was removed from a university laboratory where it was surplus to requirements.
The FH15 Flow Heater powered on with the pump running. The heater light illuminated when the set temperature was increased above ambient.
The FC20 Flow Cooler powered on, and both the compressor and fan could be heard operating.
These units do not include a built-in tank and require an external header tank to function as part of a complete system. Due to this, full-range temperature testing was not performed.
It is in good cosmetic condition.
Includes:
- Grant FH15 Flow Heater (Serial No. 72311)
- Grant FC20 Flow Cooler (Serial No. 72311)
- Model: FH15 / FC20
- Serial No.: 72311

£ 500.00 (ex. VAT) 1 in stock
Cavey Laboratory Engineering McIlwain Tissue Chopper Model MTC/2E No Blade
ITEM-42796
Cavey Laboratory Engineering McIlwain Tissue Chopper Model MTC/2E
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, powers on and is in good mechanical order. We are unable to test it further at our facility.
Please note; There is no blade present on the cutting arm.

£ 500.00 (ex. VAT) 1 in stock
Windley Bros Heavy Duty Isolation Anti Vibration Table
ITEM-42830
Windley Bros Heavy Duty Isolation Anti Vibration Table
This item was removed from a university lab where it was surplus to requirements.
It is in reasonably poor cosmetic condition with surface rust present. We are unable to test it at our facility.
This anti-vibration table is constructed from cast iron and steel. The frame comprises angle iron legs with steel bar bracing, supporting a cast iron base.
Working height: 93cm.
Solid steel tabletop: 102 x 76 x 1.2cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Aeromatic Fielder MP-Micro Fluid Bed Dryer Spares/Repair Lab
ITEM-39838
Aeromatic Fielder MP-Micro Fluid Bed Dryer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on.
Therefore, we are unable to test it further at our facility, and it's listed as Spares/Repair.
The item also contains various Assembling Dryer/ Top Sprayer Containers and cables, as seen at the end of the slide.
Specifications;
- Model: MP-MICRO
- Serial#: 04012
- Date: FEB 04

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Cytomat 24 C - Spares/Repair Lab
ITEM-40009
Thermo Scientific Cytomat 24 C Lab
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on.
The unit connects via COM port when linked to a PC running Cytomat software. (not included)
However, it does not execute commands and displays errors within the software, indicating potential internal faults.
As such, this item is listed as spares or repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Cytomat 24 C-GR Spares/Repair Lab
ITEM-40010
Thermo Scientific Cytomat 24 C-GR Lab
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on, however, the unit has a Com port error when connected to Cytomat software.
The internal screen within the door (used for the stacker system) does not power on, and there appear to be faults affecting the stacker system overall.
As such, this item is listed as spares or repair.
Please note: Software not included.

£ POA 1 in stock
Lauda Alpha RA 8 Cooling Thermostatic Water Bath Lab Spares/Repairs
ITEM-38840
This item is new in stock. Please enquire for further details.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MDF-U73V Ultra Low Temperature Freezer Spares/Repairs Lab
ITEM-35616
This Sanyo MDF-U73V Ultra Low Temperature Freezer was removed from a university lab where it was surplus to requirements.
This item is in good cosmetic condition both internally and externally.
When the freezer is turned on, an alarm will sound indicating an error that hinders its cooling function. This issue may be caused by a defective compressor, which is why the product is sold as Spares/Repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Kendro Revco Ultra Low Temperature Freezer ULT1386-3-V39 Lab Spares/Repairs
ITEM-30166
Kendro Revco Ultra Low Temperature Freezer ULT1386-3-V39
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is working but would not drop below -70˚C in testing which we don't think is cold enough to consider this s a fully working unit.
It is sold for Spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Miele Professional G 7883 Laboratory Glassware Washer - Spares/Repair Lab
ITEM-35870
Miele Professional G7883 Laboratory Glassware Washer
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonably good cosmetic condition, with a dent to the door corner and a missing front panel.
A low flow fault is present, caused by an internal component error unrelated to the water supply.
Therefore, it is listed as spares/repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
LabSystems IEMS Reader MF 1401 with Genesis Software - Spares/Repair Lab
ITEM-35860
LabSystems IEMS Reader MF 1401 with Genesis Software
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on. However, the cassette that holds the microplates in place is broken, so it cannot function as intended.
Therefore, it is listed as Spares/Repair.
Includes:
- LabSystems Genesis software
- Dust cover

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Brema Laboratory Ice Flaker Machine Model - GB 1555 A Spares/Repair Lab
ITEM-28134
Brema Laboratory Ice Flaker Machine Model GB 1555 A
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition. However, it is leaking water due to a broken junction in the overflow-to-waste pipe.
As a result, it is listed as spares or repair.
Please note: This item was previously used in a laboratory setting and is not suitable for use in commercial catering. It should be used for laboratory purposes only.
Includes:
- Operating manual
Internal dimensions: D46.5 × W67.5 × H57 cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eurotherm Process Automation System with TCS Tactician T1000 & Components
ITEM-24653
Eurotherm Process Automation System with TCS Tactician T1000 & Components
This was removed from a university lab where it was surplus to requirements.
The unit is in reasonable cosmetic condition though the access panel of the switchboard has snapped all its hinges. These will need replacing to secure the unit.
We were unable to power the unit or the TCS Tactician T1000 Controller It was not tested further. The cabinet is filled with electrical components.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Mixed Job Lot of Laboratory Equipment - Edwards, Sorvall, Prior, New Brunswick
ITEM-46866
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
- Sorvall HB-6 Swinging-Bucket Centrifuge Rotor 6 x 50ml P/N 11850 Lab
- DACS 8 Channel (Eightch) Volume Controller
- Lebow Assoc. Inc Load Cell Model no. 3132 2000lbs Lab
- AID EliSpot FluoroSpot Reader System Model ELR02 Lab
- AID EliSpot FluoroSpot Reader System HR Lab
- FluidX XTR-96 96 Tube Rack Scanner & Software Lab
- GLO Low-Speed Benchtop Laboratory Centrifuge GLO-GT416 with 270rcf Rotor Lab
- NPI Stimulus Isolation Unit Version - ISO-STIM 01D Lab
- ZEISS ECU Modular Microscope Controller - Power-IF, HPSC1, S/C-IF
- Berthold Technologies Lumat LB 9507 Tube Luminometer Lab
- Severn Analytical SA 6500 UV/VIS Absorbance Detector Lab
- Prior England Epic MEL 1 Micromanipulator Lab
- New Brunswick Scientific Model G-2 Gyrotory Laboratory Shaker Lab
- Thermo Scientific Cellject Duo Electroporator HCJD0137 Lab Spares/Repairs
- X2 ErgoOne® FAST Pipette ControllerS
- Integra PipetBoy
- Integra Vacusafe (158 3XX) With 1 x Integra Vacuboy Pipette
- Elga Purelab Ultra Genetic MK2 Benchtop Water Purifier Lab
- Hewlett Packard 16700A Logic Analysis System
- Hellma Semi-Micro Cuvettes, 104-QS, 10 mm Layer Thickness
- MJ Research PTC-225 Pelter Thermal Cycler PCR DNA Unit
- Edwards 2 Two Stage Pump Lab Spares/Repairs
- UniFlows Degasys DG-2410 Degasser
- Megger PAT Tester Model 32 Lab
- Heraeus 3336 Rotor
- Unknown Furnace
- Mettler Toledo PB3002 1DP Balance Lab
- Gould 20Ms/Sec 20 MHz Oscilloscope (DSO) 1604 Lab
- Ernst Leitz Wetzlar 307-143.004

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Claude Lyons TS Voltage Stabiliser Type TS-333 S10 Spares/Repair
ITEM-42990
Claude Lyons TS Voltage Stabiliser Type TS-333 S10
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition, however we are unable to power it on or test further due to the power cables being cut.
Therefore, it is listed as Spares/Repair.

£ 500.00 (ex. VAT) 1 in stock
Life Measurement Inc. Bod Pod Body Composition Tracking System 2007A Lab
ITEM-46309
Life Measurement Inc. Bod Pod Body Composition Tracking System 2007A Lab
This system was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Life Measurement Inc.
Body Composition Tracking System
Model - Bod Pod 2007A
SN - 3683
Includes:-
- Weighing Scales
- Cylinder Volume 49.948 L
- 2 x 10kg Weights
- User Manual (both physical & on disc)
- Software disc (Version 4.2.4)
- Bod Pod Power Supply (Part no. 1572400)
- Computer cable
- Medical Isolation Transformer
- Model no. ISB-060M
- SN - 060M 2318

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
CI Electronics Sade P2 Checkweigher Weight Sorter Spares/Repair
ITEM-46233
C1 Electronics Sade-P2 Automatic Tablet CheckWeigher
This item was removed from a university laboratory where it was surplus to requirements.
It powers on but displays a “Zero Failure” message immediately upon startup, accompanied by an alarm. This message cannot be cleared, and the unit cannot proceed to operation.
Therefore, it is listed as Spares/Repair.
It is in reasonably good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Millipore Guava EasyCyte 8HT Flow Cytometer Lab Spares/Repairs
ITEM-30464
This Millipore Guava EasyCyte 8HT Flow Cytometer was removed from a university lab where it was surplus to requirements.
The system powers up and is in good cosmetic condition with only minor marks from use.
The unit has been tested with samples but was showing readings of 200-300 when it should be showing readings of around 50000. We were unable to diagnose the exact fault.
The unit has a Dell Optiplex 7010 PC paired with it. The PC includes a keyboard, mouse, monitor, USB and VGA Cable. It has had a brand new copy of 32bit Windows 7 installed.
Guavasoft 3.1 has also been installed, which includes:
ViaCount.
InCyte (This requires an unlock code from Millipore to run).
easyCheck.
Guava Clean 3.1.
We have been able to open and close the sample tray. This proves that the system is fully connected.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MIR-153 Refrigerated Laboratory Incubator Lab Spares/Repairs
ITEM-39069
Sanyo MIR-153 Cooling Laboratory Incubator Lab
This item was removed from a university lab where it was surplus to requirements.
It is in reasonably poor cosmetic condition with noticeable damage.
Due to a faulty control panel, we were unable to set the temperature to test. Therefore, its sold as Spares or Repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sigma 3-18K Refrigerated Benchtop Laboratory Centrifuge Spares/Repairs
ITEM-39217
Sigma 3-18K Refrigerated Benchtop Laboratory Centrifuge with Rotor
This was removed from a university lab where it was surplus to requirements.
The unit powers up, but the display screen is faulty, therefore we were unable to test further.
It is in reasonably good cosmetic condition, with marks from use.
It is listed as Spares/Repairs.
Includes the following:
SIGMA 11133 Swinging Bucket Rotor w / 2 x Buckets
Bucket capacity: 4 x 550 ml

£ 500.00 (ex. VAT) 1 in stock
Gallenkamp IOI400.XX2.C Floor Standing Shaking Incubator Lab
ITEM-12238
This Gallenkamp IOI400.XX2.C Shaking Incubator was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested.
It was tested using a Thermo Smart-Vue gauge (not included).
The gauge showed 37.4ºC when the unit was set to 37ºC.
The gauge showed 59.8ºC when the unit was set to 60ºC (Max).
The max rpm is 400, which the unit runs fine at. The first digit of the rpm screen does have issues, but the rpm can still be set ok.
It is not a refrigerated unit.
Inner dimensions: 85.5cm L x 35cm W.
Shaker plate dimensions: 69cm L x 49cm W.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer Piezorray Flexible Non-contact Microarraying System Spares/Repair
ITEM-45182
Perkin Elmer Piezorray Flexible Non-contact Microarraying System Spares/Repair
This system was removed from a university laboratory where it was surplus to requirements.
The Piezorray system powers up but encounters a software error indicating a problem with the device drivers or compatibility issues when connected to the PC.
The error prevents further use and testing of the system.
Therefore, it is listed as Spares/Repair.
The system comprises the following:
- 1 x Perkin Elmer Piezorray main unit
- 1 x Enclosure, seemingly custom for the Piezorray
- 1 x Perkin Elmer Precisely Unit
- 1 x Non-branded blue and white unit
- 1 x Cole Parmer Air Admiral Pump
- 1 x Elga PURELAB UHQ
- 1 x Cole Parmer Programmable Polystat Chiller
- 1 x StockerYale IMAGELITE MODEL 20 light source with Lightpipe
- 1 x Dell Optiplex 280 PC with Windows XP OS, Perkin Elmer Piezorray software, and National Instruments Measurement & Automation software, including keyboard, mouse, and monitor
Includes:
- 3 x Tecan 731070 Syringes (used)
- 2 x Spare temperature-controlled microplate holders
- 5 x ADKH501-4PK Test Record Autodrop Pipettes (new)
- Various spare tubing
Note: Tables are not included in the sale.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sorvall RC-28S Floor-Standing Centrifuge Spares/Repair Lab
ITEM-46923
Sorvall RC 28S Floor-Standing Centrifuge Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, testing could not be completed due to an on-screen error that prevented further operation, and prevented a vacuum from being drawn.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Siemens Aspen Advanced Acuson Ultrasound Machine Spares/Repair
ITEM-46577
Siemens Aspen Advanced Acuson Ultrasound Machine (Spares/Repair)
This item was removed from a university laboratory where it was surplus to requirements.
The main unit powers on, but the screen began flickering before eventually failing.
The casing is loose in places and the hard drive has been removed. Therefore, it is listed as Spares/Repair.
Includes:
- Sony Graphic Printer UP-895MD – powers on
- Sony Video Cassette Recorder SVO-9500MDP – powers on
Model: Siemens Aspen Acuson

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Jouan SA GR 20 22 Refrigerated Centrifuge with AG 290.G Rotor Spares/Repair Lab
ITEM-40950
Jouan SA GR 20 22 Refrigerated Centrifuge with AG 290.G Rotor
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on, but the display shows "Lid Unlocked" while the lid remains stuck most of the time, occasionally opening after multiple attempts.
Additionally, the display indicates "Tachometer Failure."
When set to 2000g RCF, it does not reach the target speed, instead decelerating after approximately 500g. The deceleration from 500g to 0g takes approximately six minutes.
Due to the faults listed above, this centrifuge is listed as Spares/Repair.
Includes:
- 1x Jouan AG 290.G Swing Bucket Rotor
- 4x Jouan Swing Buckets (C/N: 11174649, S/N: 0102/03)
- 1x Box of assorted fixed-angle and swing buckets with no markings, various sizes of test tube adaptors
- 4x 125 ml Tube Adaptors
- 4x Support Feet

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Allegra X-22R Benchtop Centrifuge Spares/Repair Lab
ITEM-47198
Beckman Allegra X-22R Benchtop Centrifuge – Spares/Repair
This item was removed from a university lab where it was surplus to requirement.
It powers on and is in good cosmetic condition. However, it has been identified as having a faulty fan, compromised vibration dampers, and issues with motor suspension.
Therefore, this item is being sold strictly as Spares/Repair.
Includes:
Beckman Allegra X-22R unit only (no rotor or accessories included)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific HERAfreeze ULT Freezer HFU 2185 Basic-41 Lab Spares/Repairs
ITEM-42839
Thermo Scientific HERAfreeze HFU 2185 Basic-41 -80 Ultra Low Freezer Lab
This item was removed from a university lab where it was surplus to requirement.
The unit was described as "unreliable" prior to collection - it is sold for spares/repairs.
Specifications;
- Model HFU 2185 Basic-41
- Serial No. 020T-248264-0T
- Capacity 572 litres

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Innova U725-G Ultra Low Temperature Freezer - Spares/Repair Lab
ITEM-42838
New Brunswick Innova U725-G Ultra Low Temperature Freezer Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing it failed to drop below 2ºc when set to its minimum of -86ºc.
Therefore, it is listed as Spares/Repair.
Specifications;
- Model U725-86G
- Capacity 727 litres
- Serial No. 1016-0976-1111

£ 500.00 (ex. VAT) 1 in stock
Hema-tek 2000 Slide Stainer Model - 4488A Lab
ITEM-30367
This Hema-tek 2000 Slide Stainer Model - 4488A was removed from a university lab where it was surplus to requirements.
The unit powers up and runs. The lab informed us that it had no known faults prior to removal.
It is in good cosmetic condition with minor marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire NU-5800E C02 Incubator Lab Spares/Repairs
ITEM-39096
Nuaire 5800E C02 Incubator Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on. (Thermometer not included)
The CO2 sensor has failed on testing, therefore it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire NU-5810E CO2 Incubator Lab Spares/Repairs
ITEM-39095
Nuaire 5810E CO2 Incubator Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on. (Thermometer not included)
The CO2 did not increase on testing, and the sample pump failed, therefore it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Heracell 150i Incubator Lab Spares/Repairs
ITEM-37320
Thermo Scientific Heracell 150i Incubator Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however due to a suspected board fault an error was produced that prevented further testing.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire NU-5510E Incubator Lab Spares/Repairs
ITEM-46172
Nuaire NU-5510E Incubator Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and successfully reached and stabilised at 37ºc, however it failed to reach its maximum temperature of 60ºc.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire Model NU-5510E Incubator Lab Spares/Repairs
ITEM-46173
Nuaire NU-5510E Incubator Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and successfully reached and stabilised at 37ºc, however it failed to reach its maximum temperature of 60ºc.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Hitachi F-4500 Fluorescence Spectrophotometer System Spares/Repair Lab
ITEM-42393
Hitachi F-4500 Fluorescence Spectrophotometer System
This item was removed from a university laboratory where it was surplus to requirements.
The Hitachi F-4500 unit does not power on; however, it is in good condition with minimal wear. The previous owner said the PSU had failed.
Due to it not powering on it is listed as Spares/Repair
Includes:
- Vigen Genie P3 500 Computer
- Model: F-4500
- Serial No.: 1163-004
- Software: F-4500 FL_mnu - 2504060-05.
Items 1801 to 1850 of 2710