All Products
Items 1951 to 2000 of 2572

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Binder KB 240 Refrigerated Incubator Spares/Repair Lab
ITEM-42729
Binder KB 240 Refrigerated Incubator
This item was removed from a facility where it was surplus to requirement.
The unit powers on, and the screen is functional.
However, temperature settings could not be adjusted during testing, and the unit did not rise above ambient temperature when left running.
Therefore, it is listed as Spares/Repair.
Includes:
- Four internal shelves

£ 500.00 (ex. VAT) 1 in stock
Panasonic Model No. AW-HE60 CCTV Camera
ITEM-37269
Panasonic AW-HE50 CCTV Cameras
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers on.
The previous client has stated it was in full working order prior to removal.
This item was tested with an in-house power supply cable. (not included.)

£ 500.00 (ex. VAT) 1 in stock
Spellman Power Supply RSBX30X3077 Lab
ITEM-34855
Spellman Power Supply RSBX30X3077
Model: RSBX30X3077
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, but we are unable to test it at our facility.
Includes 9-pin FEMALE DIN Cable.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Mixed Job Lot of Laboratory Equipment - Syngene, Polymer, VWR, Carl Zeiss, WPA
ITEM-37348
Mixed Job Lot of Laboratory Equipment - Syngene, Polymer, VWR, Carl Zeiss, WPA
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
ITEM-37345 Syngene InGenius LHR Gel Doc Imaging System Lab
ITEM-37347 Polymer Laboratories PL-AS RT GPC Auto Sampler Lab
ITEM-37376 VWR KuroGel Maxi 20 Electrophoresis
ITEM-37379 2x Air admiral Cole Parmer Pumps
ITEM-37380 fisherbrand 70155 pump and fisherbrand FB70150 pump
ITEM-37381 Mettler collage2440 Delta Range Weighing Scales
ITEM-37383 3x Boxes of small glass panels
ITEM-37384 Metal Frame
ITEM-37388 Box of cables and adapters
ITEM-37389 2x Hamilton 76615 Syringe cleaner
ITEM-37393 Oertling Model-A03 Balancing Scales
ITEM-37394 Glass Lab Beaker/Flask
ITEM-37395 harvard student oscillograph
ITEM-37396 Scalamp Galvanometer
ITEM-37397 Psychogalvanometer
ITEM-37398 Digital Storage Oscilloscope
ITEM-37399 WPA Edspot long scale galvanometer
ITEM-37400 Mannesmann Tally Pixy
ITEM-37401 Linstead E.H.T Supply Type S2
ITEM-37402 Unimatic SN1 Stanton
ITEM-37405 Wayne Kerr Bridge Detector
ITEM-37406 2x RS Digital MultiMeters
ITEM-37407 Walter Ozonizer
ITEM-37409 Miscellaneous Parts
ITEM-37410 Shuttle X Super ritemaster
ITEM-37412 beckman london eyepiece
ITEM-37413 Various cables
ITEM-45387 Thermo Scientific HAAKE SC 100 Digital Immersion Cooler/Heater Lab
ITEM-45440 Perkin Elmer GeneAmp 9600 PCR
ITEM-45463 Marzhauser Wetzlar 2-Achsen-Joystick CZ
ITEM-45464 Thermo Orion 3 Star pH Benchtop
ITEM-45465 A&D Instruments t6969 0.01 Balance
ITEM-45466 mettler toledo fiveeasy fe20
ITEM-45467 Carl Zeiss NAG 2, 12V 100W Stab Power Supply
ITEM-45468 VWR Lab Dancer s42
ITEM-45469 VWR Lab Dancer s42
ITEM-45472 Lot of Hendley Essex Microscope Slides
ITEM-46049 Unbranded Microscope Eye pieces
ITEM-46050 Dosimeter Charging Unit
ITEM-46129 Hanna Instruments HI 2211 pH/ORP Meter
ITEM-46249 A&D AND FR-200 Digital Precision Analytical Balance Weighing Scales Lab
ITEM-46290 Ablerex 3000 rt plus

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Z Corporation ZPrinter 450 3D Printer Spares/Repair Lab
ITEM-37485
Z Corporation ZPrinter 450 3D Printer
This item was removed from a university laboratory where it was surplus to requirements.
In good cosmetic condition. The printer failed to power on and did not pass the PAT test.
Therefore, it is listed as Spares/Repair.
Specifications;
- Build speed: between 2 to 4 layers per minute
Build volume:
- X-axis: 8 inches (203 mm)
- Y-axis: 10 inches (254 mm)
- Z-axis: 8 inches (203 mm)
- Build capacity: 640 cubic inches
- Layer thickness:
- Minimum: 0.0035 inches (0.089 mm)
- Maximum: 0.004 inches (0.102 mm)
- Color shell thickness: 0.025 inches
- Resolution: 300 x 450 dpi
- Materials:
- Powder: zp130
- Binder: zb59
- Print heads:
- HP11 (clear binder)
- HP57 (single tricolor CMY)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Hitachi F-4500 Fluorescence Spectrophotometer System Spares/Repair Lab
ITEM-42393
Hitachi F-4500 Fluorescence Spectrophotometer System
This item was removed from a university laboratory where it was surplus to requirements.
The Hitachi F-4500 unit does not power on; however, it is in good condition with minimal wear. The previous owner said the PSU had failed.
Due to it not powering on it is listed as Spares/Repair
Includes:
- Vigen Genie P3 500 Computer
- Model: F-4500
- Serial No.: 1163-004
- Software: F-4500 FL_mnu - 2504060-05.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire Model NU-5510E Incubator Lab Spares/Repairs
ITEM-46173
Nuaire NU-5510E Incubator Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and successfully reached and stabilised at 37ºc, however it failed to reach its maximum temperature of 60ºc.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire NU-5510E Incubator Lab Spares/Repairs
ITEM-46172
Nuaire NU-5510E Incubator Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and successfully reached and stabilised at 37ºc, however it failed to reach its maximum temperature of 60ºc.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Heracell 150i Incubator Lab Spares/Repairs
ITEM-37320
Thermo Scientific Heracell 150i Incubator Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however due to a suspected board fault an error was produced that prevented further testing.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Allegra X-22R Benchtop Centrifuge Spares/Repair Lab
ITEM-47198
Beckman Allegra X-22R Benchtop Centrifuge – Spares/Repair
This item was removed from a university lab where it was surplus to requirement.
It powers on and is in good cosmetic condition. However, it has been identified as having a faulty fan, compromised vibration dampers, and issues with motor suspension.
Therefore, this item is being sold strictly as Spares/Repair.
Includes:
Beckman Allegra X-22R unit only (no rotor or accessories included)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Jouan SA GR 20 22 Refrigerated Centrifuge with AG 290.G Rotor Spares/Repair Lab
ITEM-40950
Jouan SA GR 20 22 Refrigerated Centrifuge with AG 290.G Rotor
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on, but the display shows "Lid Unlocked" while the lid remains stuck most of the time, occasionally opening after multiple attempts.
Additionally, the display indicates "Tachometer Failure."
When set to 2000g RCF, it does not reach the target speed, instead decelerating after approximately 500g. The deceleration from 500g to 0g takes approximately six minutes.
Due to the faults listed above, this centrifuge is listed as Spares/Repair.
Includes:
- 1x Jouan AG 290.G Swing Bucket Rotor
- 4x Jouan Swing Buckets (C/N: 11174649, S/N: 0102/03)
- 1x Box of assorted fixed-angle and swing buckets with no markings, various sizes of test tube adaptors
- 4x 125 ml Tube Adaptors
- 4x Support Feet

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sorvall RC-28S Floor-Standing Centrifuge Spares/Repair Lab
ITEM-46923
Sorvall RC 28S Floor-Standing Centrifuge Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, testing could not be completed due to an on-screen error that prevented further operation, and prevented a vacuum from being drawn.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer Piezorray Flexible Non-contact Microarraying System Spares/Repair
ITEM-45182
Perkin Elmer Piezorray Flexible Non-contact Microarraying System Spares/Repair
This system was removed from a university laboratory where it was surplus to requirements.
The Piezorray system powers up but encounters a software error indicating a problem with the device drivers or compatibility issues when connected to the PC.
The error prevents further use and testing of the system.
Therefore, it is listed as Spares/Repair.
The system comprises the following:
- 1 x Perkin Elmer Piezorray main unit
- 1 x Enclosure, seemingly custom for the Piezorray
- 1 x Perkin Elmer Precisely Unit
- 1 x Non-branded blue and white unit
- 1 x Cole Parmer Air Admiral Pump
- 1 x Elga PURELAB UHQ
- 1 x Cole Parmer Programmable Polystat Chiller
- 1 x StockerYale IMAGELITE MODEL 20 light source with Lightpipe
- 1 x Dell Optiplex 280 PC with Windows XP OS, Perkin Elmer Piezorray software, and National Instruments Measurement & Automation software, including keyboard, mouse, and monitor
Includes:
- 3 x Tecan 731070 Syringes (used)
- 2 x Spare temperature-controlled microplate holders
- 5 x ADKH501-4PK Test Record Autodrop Pipettes (new)
- Various spare tubing
Note: Tables are not included in the sale.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sigma 3-18K Refrigerated Benchtop Laboratory Centrifuge Spares/Repairs
ITEM-39217
Sigma 3-18K Refrigerated Benchtop Laboratory Centrifuge with Rotor
This was removed from a university lab where it was surplus to requirements.
The unit powers up, but the display screen is faulty, therefore we were unable to test further.
It is in reasonably good cosmetic condition, with marks from use.
It is listed as Spares/Repairs.
Includes the following:
SIGMA 11133 Swinging Bucket Rotor w / 2 x Buckets
Bucket capacity: 4 x 550 ml

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
CI Electronics Sade P2 Checkweigher Weight Sorter Spares/Repair
ITEM-46233
C1 Electronics Sade-P2 Automatic Tablet CheckWeigher
This item was removed from a university laboratory where it was surplus to requirements.
It powers on but displays a “Zero Failure” message immediately upon startup, accompanied by an alarm. This message cannot be cleared, and the unit cannot proceed to operation.
Therefore, it is listed as Spares/Repair.
It is in reasonably good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eurotherm Process Automation System with TCS Tactician T1000 & Components
ITEM-24653
Eurotherm Process Automation System with TCS Tactician T1000 & Components
This was removed from a university lab where it was surplus to requirements.
The unit is in reasonable cosmetic condition though the access panel of the switchboard has snapped all its hinges. These will need replacing to secure the unit.
We were unable to power the unit or the TCS Tactician T1000 Controller It was not tested further. The cabinet is filled with electrical components.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Dynamic Gastric Model (DGM) Custom Made Model Lab Spares/Repairs
ITEM-46358
Dynamic Gastric Custom Made Model
This item was removed from a university lab where it was surplus to requirements.
This custom-made Dynamic Gastric Model exhibits poor cosmetic condition. It cannot be powered on or tested due to a visual PAT failure and exposed wiring.
The Dynamic Gastric Model (DGM) is a bench-top computer controlled in vitro system that simulates digestion in the human stomach. DGM allows accurate prediction and understanding of the behaviour of foods or drug preparations within the human gut during digestion in real time.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Brema Laboratory Ice Flaker Machine Model - GB 1555 A Spares/Repair Lab
ITEM-28134
Brema Laboratory Ice Flaker Machine Model GB 1555 A
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition. However, it is leaking water due to a broken junction in the overflow-to-waste pipe.
As a result, it is listed as spares or repair.
Please note: This item was previously used in a laboratory setting and is not suitable for use in commercial catering. It should be used for laboratory purposes only.
Includes:
- Operating manual
Internal dimensions: D46.5 × W67.5 × H57 cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Typhoon Trio+ Variable Mode Imager Spares/Repair Lab
ITEM-37335
Typhoon Trio+ Variable Mode Imager
This item was removed from a university lab where it was surplus to requirement.
It has not been tested due to exposed wiring, and is sold as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Aeromatic Fielder MP-Micro Fluid Bed Dryer Spares/Repair Lab
ITEM-39838
Aeromatic Fielder MP-Micro Fluid Bed Dryer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on.
Therefore, we are unable to test it further at our facility, and it's listed as Spares/Repair.
The item also contains various Assembling Dryer/ Top Sprayer Containers and cables, as seen at the end of the slide.
Specifications;
- Model: MP-MICRO
- Serial#: 04012
- Date: FEB 04

£ 500.00 (ex. VAT) 1 in stock
Synbiosis aCOLyte 3 Colony Counter 8000/SYN Lab
ITEM-35291
This Synbiosis aCOLyte 3 Colony Counter was removed from a university lab where it was surplus to requirements.
This unit powers up with a 12V DC power adapter (not included). The device runs through the 3 different start-up stages but has not been tested further.
It is in good cosmetic condition with marks from use.

£ 500.00 (ex. VAT) 1 in stock
Windley Bros Heavy Duty Isolation Anti Vibration Table
ITEM-42830
Windley Bros Heavy Duty Isolation Anti Vibration Table
This item was removed from a university lab where it was surplus to requirements.
It is in reasonably poor cosmetic condition with surface rust present. We are unable to test it at our facility.
This anti-vibration table is constructed from cast iron and steel. The frame comprises angle iron legs with steel bar bracing, supporting a cast iron base.
Working height: 93cm.
Solid steel tabletop: 102 x 76 x 1.2cm

£ 500.00 (ex. VAT) 1 in stock
Wykeham Farrance Oedometer CBR Testing Lab
ITEM-34568
This Wykeham Farrance Oedometer CBR Testing was removed from a university lab where it was surplus to requirements.
The unit powers up the hand control unit works correctly, and the hydraulic ram goes up and down freely.
It is in reasonable cosmetic condition with marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Innova Type 4330 Incubator Shaker Lab
ITEM-40993
This New Brunswick Innova Type 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.
The unit powers up and heats, but does not cool or shake.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Innova 4330 Incubator Shaker Lab Spares/Repairs
ITEM-40991
This New Brunswick Innova 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.
The unit powers up but does not shake. The heating and cooling functions work.
It is in reasonably good cosmetic condition with minor marks.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Innova Model 4330 Incubator Shaker Lab Spares/Repairs
ITEM-40992
New Brunswick Innova Model 4330 Incubator
This was removed from a university lab where it was surplus to requirements.
The unit heats but does not cool. The shaking works, but requires maintenance.
It is sold for spares/repairs.

£ POA 1 in stock
VG Scientific Wien Mass Filter for Ion Beam Filtering UHV Lab
ITEM-19542
This item is new in stock. Please enquire for further details.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Xenogen Ivis 100 Imaging System Microscope - XGI-8, XRH-2 Lab
ITEM-29746
Xenogen Ivis 100 Imaging System Microscope - XGI-8, XRH-2 Lab
This system was removed from a university lab where it was surplus to requirements.
We have powered everything up and the system is in good cosmetic condition with marks from use.
The lab informed us that it has not been used for several years but was in working order when last used. The calibrated light source has now been removed so we are now selling for spares/repairs.
Included as part of the Ivis 100 are;
1 x IGC Polycold Systems Inc, Cryotiger Compressor.
1 x Spectral Instruments Inc, 600 Series CCD Camera Controller.
1 x Spectral Instruments Inc, Refrigeration Line Heater.
1 x Xenogen Corporation, XGI-8 gas Anesthesia System.
1 x DELL PC & Monitor, Running Windows 2000 Professional.
Instruction Manuals & Xenogen Living Image Version 2.20 Discs included.
Instruction Manuals & Xenogen Living Image Version 2.20 Discs included.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Scientific Innova CO-170 Lab Spares/Repairs
ITEM-40039
New Brunswick Scientific Innova CO-170 Lab
This item was removed from a university lab where it was surplus to requirements.
The unit powers up and is in fairly poor cosmetic condition with some rust, it has been temperature-tested. (thermometer not included)
The unit developed a back-light fault in the screen during CO2 testing. It is sold as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf 5810R BenchTop Centrifuge Spares/Repair Lab
ITEM-46918
Eppendorf 5810R BenchTop Centrifuge
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and powers on.
During testing, it failed to reach its maximum specified temperature of 40ºC.
Due to these issues stated above, this centrifuge is being sold as spares or repairs.

£ 500.00 (ex. VAT) 1 in stock
VWR PCR Plate Centrifuge II Lab
ITEM-49516
VWR PCR Plate Centrifuge II Lab
This item is sold on behalf of a client where it is surplus to requirements.
This item is in complete working order, and in good cosmetic condition.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

£ 500.00 (ex. VAT) 1 in stock
Ohaus Frontier Micro Centrifuge FC5513 Lab
ITEM-49518
Ohaus Frontier Micro Centrifuge FC5513 Lab
This item is sold on behalf of a client where it is surplus to requirements.
This item is in complete working order, and in good cosmetic condition.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

£ 500.00 (ex. VAT) 1 in stock
Grant FH15 Flow Heater and FC20 Flow Cooler Lab
ITEM-42784
Grant FH15 Flow Heater and FC20 Flow Cooler
This system was removed from a university laboratory where it was surplus to requirements.
The FH15 Flow Heater powered on with the pump running. The heater light illuminated when the set temperature was increased above ambient.
The FC20 Flow Cooler powered on, and both the compressor and fan could be heard operating.
These units do not include a built-in tank and require an external header tank to function as part of a complete system. Due to this, full-range temperature testing was not performed.
It is in good cosmetic condition.
Includes:
- Grant FH15 Flow Heater (Serial No. 72311)
- Grant FC20 Flow Cooler (Serial No. 72311)
- Model: FH15 / FC20
- Serial No.: 72311

£ 500.00 (ex. VAT) 1 in stock
Cavey Laboratory Engineering McIlwain Tissue Chopper Model MTC/2E No Blade
ITEM-42796
Cavey Laboratory Engineering McIlwain Tissue Chopper Model MTC/2E
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, powers on and is in good mechanical order. We are unable to test it further at our facility.
Please note; There is no blade present on the cutting arm.

£ 500.00 (ex. VAT) 1 in stock
VWR LA 214 Laboratory Balance
ITEM-49530
VWR LA 214 Laboratory Balance
This item is sold on behalf of a client where it is surplus to requirements.
This item has a max capacity of 220 g with a readability of 4 decimal places. It was serviced: 05/09/2024.
It is in perfectly good condition and working order, with no significant cosmetic defects. The balance was in use in an industry laboratory up until June 2025 and was removed during a lab shutdown.
The item comes with the power cable.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Agilent 2100 G2939A Bioanalyzer System & DNA Chips Spares/Repair Lab
ITEM-48419
Agilent 2100 G2939A Bioanalyzer System & Accessories Spares/Repair Lab
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and powers on, however it could not be fully tested as two channels show high leakage currents.
Therefore, it is being sold as spares or repair.
Includes:
- 1 box x High Sensitivity DNA Chips (5 in box) – expires Jan 2026
- 1 box x High Sensitivity DNA Chips (10 in box) – expires Jan 2026
- 1 box x Electrode Cleaners (5 in box)
- 1 box x Chip Priming Station
- 1 x Bayonet Electrode Cartridge (in blue case)
- 1 box x 11 Syringe Kits
- 1 box containing Test Chip Kit/Electrode/Diode Test Chip & USB 2.0 Cable
Model: 2100 Bioanalyzer
Serial No.: DE13805731
Product No.: G2938C

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller Spares/Repair Lab
ITEM-47102
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller
This item was removed from a university laboratory where it was surplus to requirements.
The item is in reasonably good cosmetic condition; however, it cannot be powered on due to the absence of a plug and a split in the flex exposing the internal wires.
It is therefore sold as spares or repair.
Includes:
- Carl Zeiss Surgical Microscope
- Metz NAG 80 VA Controller

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Integrated BMS Jet Nozzle Test Facility -CP3 Lab Spares/Repairs
ITEM-41471
Integrated BMS Jet Nozzle Test Facility -CP3 Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to power it on or test it further at our facility. The unit has no power cable.
Therefore, it is listed as Spares/Repair.
Includes operation keys.
Door key not included but can be opened with a standard control cabinet key.

£ 500.00 (ex. VAT) 1 in stock
Irori AccuTag 100 Scanning Station Model: At-100-CS-CE Lab
ITEM-24838
This Irori AccuTag 100 Scanning Station Model: At-100-CS-CE was removed from a university lab where it was surplus to requirements.
The item is in reasonable cosmetic condition. There are scratches/dents on the surface, along with stains. The accessories have been used and thus have broken seals.
The item was plugged in, but there wasn't any clear indication it had powered on. We were unable to test it further without a PC connection.
Also included are the following:
1x AccuTag Synthesis Manager Version 1.0
1x AccuTag Synthesis Manager Version 2.26
12x Irori Radio Frequency Tag
1x PSU
1x DE-9 cable

£ 500.00 (ex. VAT) 1 in stock
GT 55 Liquid Nitrogen Dewar with 6 x Storage Racks Lab
ITEM-25464
This GT 55 Liquid Nitrogen Dewar with 6 x Storage Racks was removed from a university lab where it was surplus to requirements.
The unit is in reasonable cosmetic condition with some marks from use. It has not been tested.
There are 6 Racks inside with drawers that hold 5ml tubes.

£ 500.00 (ex. VAT) 1 in stock
AT Delta-T Logger System with Software & Accessories Lab
ITEM-25021
This was removed from a university lab where it was surplus to requirements.
The system is in reasonable cosmetic condition. There are stains and other marks along the edges and surface. The atmospheric temperature & humidity probe is dented.
The item is untested as it wasn't supplied with a PSU.
Also included are the following:
1x Delta-T Devices atmospheric temperature & humidity probe
S/N: RHAI-077
1x Delta-T PC software type LS2
Version 1.04
1x Desiccant Pack
1x DE-9 cable
1x Tutorial Kit
1x Spares & Accessory Pack
3x Component part (EMC directive) 5m
5x Temperature Probes User Manual
1x Quantum Sensor User Manual
1x Delta-T Devices Data Loggers, Sensors & Systems
1x Delta-T Devices Plant Science & Solar Radiation Studies
1x Delta-T Devices Image Analysis Systems
1x Delta-T Logger User Manual Version 2.01

£ 500.00 (ex. VAT) 1 in stock
PSL Rheotek TCB 8 Temperature Controlled Water Viscometer Bath Lab
ITEM-28205
PSL Rheotek TCB 8 Temperature Controlled Viscometer Bath
This was removed from a university lab where it was surplus to requirements.
The unit powers up and the heating is in good working order.
Inside tank dimensions - L59 W31 H37cm
It is in good cosmetic condition with some marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
WEG CFW -11 Venture Inverter Control Box Lab Spares/Repairs
ITEM-41470
WEG CFW -11 Venture Inverter Control Box Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to power it on or test it further at our facility.
The key is not included but can be opened with a standard control cabinet key.
Includes manual.
The unit has no cable so is sold for spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Milestone Ethos plus 2 SEL Microwave Solvent Extraction Labstation Spares/Repair
ITEM-41135
Milestone Ethos plus 2 Microwave Solvent Extraction Labstation
This system was removed from a university where it was surplus to requirement.
All units are in good cosmetic condition, with the primary unit (Milestone Ethos plus 2) and PC Set-Up turning on, however, there is no power in the LabTerminal 800 Controller.
The system is sold for spares/repairs.
-1x Milestone Microwave Laboratory Systems LabTerminal 800 Controller
1x easywave chip card for the controller
S/N- 0205722
-2x Rotor' for microwave
- Relevant vessels and safety shields for rotors
-2x ATC-FO sensors for microwave
-2x Torque wrenches for rotor
-2x Extraction Pipes
1x Monitor (IIyama Prolite B2206WS) and Dell Tower Optiplex GX620
Includes: Pipette tracker v3.3 Software

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nikon Diaphot 300 Microscope *Condenser Removed* Lab Spares/Repairs
ITEM-39790
Nikon Diaphot 300 Microscope *Condenser Removed*
This microscope was removed from a university lab where it was surplus to requirements.
All mechanical elements are in good working order. The unit does not include the power supply or condenser therefore we are unable to perform any other tests. It is in good cosmetic condition with minor marks.
As stated in the title the condenser is not included.
It is made up of the following modules;
Nikon ND2 Filter
Nikon ND4 Filter
Nikon CFWN 10x/20 Eyepiece x 2
Nikon 100w Mercury Lamphouse LH-M100C-1
Nikon Halogen 12V 100W Microscope Lamp

£ 500.00 (ex. VAT) 1 in stock
Xerox Phaser 7400 Laser Printer With Ink Cartridges
ITEM-35876
Xerox Phaser 7400 Laser Printer With Ink Cartridges
This was removed from a university lab where it was surplus to requirements.
It powers up and is in good working order.
Includes 4 x ink cartridges:
-1 x Cyan (Imaging unit 108R00647)
-1 x Magenta (Imaging unit 108R00648)
-1 x Yellow (Imaging unit 108R00649)
-1 x Black (Imaging unit 108R00650)
Max prints per minute- 40
Model number- N31201B
Serial number- WNC757283

£ 500.00 (ex. VAT) 1 in stock
LEEC Research CO2 Incubator Model GA2000 Lab
ITEM-41593
LEEC Research CO2 Incubator Model-GA2000
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in reasonably good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter Optima TLX Ultracentrifuge 120,000rpm Lab Spares/Repairs
ITEM-34798
Beckman Coulter Optima TLX Ultracentrifuge 120,000rpm
This was removed from a university lab where it was surplus to requirements.
The unit powers up but half of the keypad no longer works. It is sold for spares/repairs.

£ 500.00 (ex. VAT) 1 in stock
Nikon Microphot-FXA Fluorescence Microscope with HP-10101AF PSU & 4 x Objectives
ITEM-24299
This Nikon Microphot-FXA Fluorescence Microscope was removed from a university lab where it was surplus to requirements.
The PSU is missing so we were unable to power up the Microscope. It requires a Nikon PSM-4A. The power supply unit for the mercury lamp is present. The PSU is working but the bulb needs to be replaced.
The system is in reasonably good cosmetic condition with marks from use.
It has;
2x Nikon FX-350X 35mm film cameras attached via Nikon mounts.
1 x SOFT RTS 25.4 2mp slider with data lead.
1 x NIKON 4/0.10
1 x NIKON FLUOR 20 0.75 160/0.17
1 x NIKON FLUOR 40 0.85 160/0.11-0.23
1 x NIKON FLUOR 100 / 1.30 OIL 160/0.17
2 x CFWN D10 X/20
There is a PC with ISMOL Software & relevant PCI cards for connecting everything.

£ 500.00 (ex. VAT) 1 in stock
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories Lab
ITEM-24618
TCR TECORA Echo HiVol Hi Volume Sampler System with Accessories
This was removed from a university lab where it was surplus to requirements.
The system consists of;
1 x Echo HiVol Hi Volume Sampler
Model, Echo Hi Vol
110V
The unit powers on and is in good cosmetic condition. It was powered on by our Step down from the mains supply (not included).
The buttons seem a little slow to respond and there are some tape marks and scuffs and scratches around the unit from general use. The unit is lockable but no key is supplied. The key is included.
1 x Delta Wireless Sampler
Electronic Flow Sampler w/ Battery pack
Model Delta
110V
The unit powers on and is in good cosmetic condition. We did not charge Battery to test, as we used our Step down from the mains supply. (not included).
1 x Delta Battery pack
The unit is in good cosmetic condition. It was not tested.
2 x Flight Casea
3x Marigold gloves (size 9)
1x Spanner (size 10)
2x fuses T6.3AL 250V
4X keys
1x Widget H045
1x TCR Fine PM Air Inlet PM 2.5 200l/min
1x Metal Filter attachment
2x Glass chambers
1x Metal Dome
3x Sanitising spray
2x TCR TECORA plastic sample trays (3cm diameter)
6x Sample dishes with lids (14cm diameter)
4x Glass condensers 1x opened 3x factory sealed
1x Delta quick guide
2x Boxes of Microfibre Discs (1x opened 102mm Dia) quantity unknown
(1x sealed 100 Dia) quantity 100
1x Flurescein Green Concentrate (bottle partially full, sealed inside a bag it has leaked at some point.
1x Air pollution monitoring equipment (Metal chamber with hose)
1 x manual
1 x TCR Tecora TCR Downloader for Echo Series, Delta & Bravo Plus.
There is also a software disk included with this but it is entirely in Italian.
Items 1951 to 2000 of 2572