Our General Laboratory category offers a wide selection of high-quality, second-hand equipment designed to meet the diverse needs of laboratories. Specializing in essential lab tools such as balances, incubators, hot plates, and centrifuges, our range is ideal for research, educational, and industrial facilities.


Equipment undergoes varying levels of testing, including functionality checks, as well as temperature and CO2 performance assessments, ensuring reliable solutions for your laboratory’s daily operations and environmental control needs.

Items 701 to 750 of 1294

Image of Newport Anti-Vibration Isolation Table Top Metric

£ 500.00 (ex. VAT) 1 in stock

Newport Anti-Vibration Isolation Table Top Metric

ITEM-54910

Newport Anti-Vibration Isolation Table Top Metric


This item was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition.

Image of Thermo Scientific Revco UXF Ultra Low Temperature Freezer

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific Revco UXF Ultra Low Temperature Freezer

ITEM-52383

Thermo Scientific Revco UXF Ultra Low Temperature Freezer Spares/Repair


This item was removed from a facility where it was surplus to requirement.


The unit powers on, however it powers down and restarts after approximately 3–5 minutes.


Additionally, on start-up, an error message is displayed: “Failed to connect to SD Card.”


No further testing has been carried out due to the fault described above. As such, the unit is offered as spares/repair.


Model: Revco UXF

Model No: UXF60086V

Image of Thermo Scientific Max Q 4000 Shaking Incubator Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific Max Q 4000 Shaking Incubator Lab

ITEM-50208

Thermo Scientific MaxQ 4000 Shaking Incubator – Spares/Repair


This was removed from a laboratory environment where it was surplus to requirements.


The unit powers on and is in good cosmetic condition with minor marks from use.


Following inspection and basic fault-finding, power is confirmed as reaching the unit and the PSU is functioning correctly.


However, power is not being passed through the control board to the PSU. This indicates a likely fault with the power control board.


The unit is therefore listed as Spares/Repair.

Image of MTI Corporation Hot Sealing Machine

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

MTI Corporation Hot Sealing Machine

ITEM-50824

MTI Corporation Hot Sealing Machine


This item has been removed from a facility as part of a surplus clearance.


The powers on, however, it is currently non-functional due to a pneumatic/sealing fault.


Due to this issue, the unit is being sold as spares or repair.

Image of Bellco Biotechnology Production Roller Apparatus Model 7340-10230

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Bellco Biotechnology Production Roller Apparatus Model 7340-10230

ITEM-49770

Bellco Biotechnology Production Roller Apparatus (Model 7340-10230) – Spares/Repair


This item was removed from a facility where it was surplus to requirements.


The unit is in poor cosmetic condition and is missing several rollers. The rear panels were loose but have been secured with new nuts and bolts. The item powers on, and the motor can be heard running; however, the rollers do not move at all.


Due to this operational fault and missing components, the unit is offered as Spares/Repair.


Model: 7340-10230

Image of Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Lab

ITEM-49742

Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however during testing the following error was present; Error 17, a PCB fault.


Which prevented any further testing.


It is therefore listed as Spares/Repair.

Image of Genevac VC3000TA Vapour Condenser Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Genevac VC3000TA Vapour Condenser Lab

ITEM-48656

Genevac VC3000TA Vapour Condenser Spares/Repair Lab


This item was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition, but was unable to be tested as it requires connection to a Genevac Centrifugal Evaporator. (Not included)


Additionally, the previous owner notified us that it was faulty, although the fault was not diagnosed,


It is therefore listed as Spares/Repair

Image of Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump Lab

ITEM-48347

Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump – Spares/Repair


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition and powers on; however, the previous owner has stated it is faulty, with the fault unspecified. Supplied with cables for connecting to the rest of a system, along with an Automatic Backpressure Valve (PN-900-13702-000).


Includes:


  • Cables for system connection
  • Automatic Backpressure Valve (PN-900-13702-000)
Image of Hermle Z 300 K Centrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Hermle Z 300 K Centrifuge Lab

ITEM-47684

Hermle Z 300 K Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and shows minimal wear.

However, during testing it failed to reach the set temperature, stabilizing at 25°C, and did not achieve the rotor’s maximum speed of 5000 RPM, reaching only 4000 RPM.


Therefore, it is listed as spares/repair.


Model: Z 300 K

Serial No.: 55060105

Image of Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge Lab

ITEM-47421

Thermo Scientific Megafuge 40R Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


The centrifuge displays an E33 error, indicating a fault with the main board. The working condition of the remaining parts is unknown:


  • 2 x Lid locks (at least one reported to have an issue)
  • 1 x Motor
  • 1 x Compressor
  • 1 x Display board
  • 1 x Temperature sensor

Due to the issues stated above, this centrifuge is listed as Spares/Repair.


Please note: There is no rotor included.

Image of Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge Lab

ITEM-47420

Thermo Scientific Megafuge 40R Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


The casing is in good used cosmetic condition. However, following internal components have been removed:

  • 2 x lid locks/mechanisms
  • 1 x motor

The main board is present but faulty and displays an E33 error on startup. The condition of other internal components—including the compressor, display, and temperature sensor is unknown and has not been tested.


Therefore, it is listed as Spares/Repair.


Please note: There is no rotor included.

Image of Whatman/Parker Balston UHP Nitrogen Generator Model 76-94-220

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Whatman/Parker Balston UHP Nitrogen Generator Model 76-94-220

ITEM-46647

Whatman/Parker Balston UHP Nitrogen Generator Model 76-94-220


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however, the previous owner has stated it is not in working order.

Image of Systec DB-45 Autoclave Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Systec DB-45 Autoclave Lab

ITEM-46571

Systec DB-45 Autoclave Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition but does not power on, therefore it is listed as Spares/Repair.

Image of Sorvall RC-3B Plus Floor Standing Centrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Sorvall RC-3B Plus Floor Standing Centrifuge Lab

ITEM-46525

Sorvall RC-3B Plus Floor Standing Centrifuge - Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition but has not been tested on site due to the service report attached stating;


Rotor lock: Seized, cannot remove rotor

No reported problems Service and check as above Unit is old

Note 6: door seal has shrunk and will not go back into place

Note 9: chamber is corroded due to substance.

Note 10: gas struts have failed, lid is heavy and can fall.

Note 12: drive shaft housing corroded.


Therefore, it is listed as Spares/Repair.

Image of LTE Scientific Falcon 30 Benchtop Laboratory Autoclave Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

LTE Scientific Falcon 30 Benchtop Laboratory Autoclave Lab

ITEM-46403

LTE Scientific Falcon 30 Benchtop Laboratory Autoclave


This item was removed from a university lab where it was surplus to requirements.


The unit powers on and is in reasonably good cosmetic condition. However, it failed a recent service.


Therefore, it is listed as Spares/Repair.

Image of Thermo Scientific HERAfreeze ULT Freezer HFU 2185 Basic-41 Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific HERAfreeze ULT Freezer HFU 2185 Basic-41 Lab

ITEM-42839

Thermo Scientific HERAfreeze HFU 2185 Basic-41 -80 Ultra Low Freezer Lab


This item was removed from a university lab where it was surplus to requirement.



The unit was described as "unreliable" prior to collection - it is sold for spares/repairs.



Specifications;


  • Model HFU 2185 Basic-41
  • Serial No. 020T-248264-0T
  • Capacity 572 litres
Image of Oxford Cryosystems Cryodrive 2.0 Helium Compressor Model - 972B000A

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Oxford Cryosystems Cryodrive 2.0 Helium Compressor Model - 972B000A

ITEM-54084

Oxford Cryosystems Cryodrive 2.0 Helium Compressor (Model 972B000A)


This item has been removed from a facility as part of a surplus clearance.


The unit briefly powers on, with the green power light illuminating; however, no further activity is observed and the system is unable to initialise.


Due to this fault, the unit is being sold as Spares/Repair.

Image of Beckman L5-50B Ultracentrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Beckman L5-50B Ultracentrifuge Lab

ITEM-51430

Beckman L5-50B Ultracentrifuge Spares/Repair Lab


This item was removed from a facility where it was surplus to requirement.


The unit powers on, however, it displays a balance error which prevents any further testing from being carried out.


It is therefore being sold for Spares/Repair.

Image of Thermo Savant MICROMODULYO Freeze Dryer

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Savant MICROMODULYO Freeze Dryer

ITEM-50209

Thermo Savant MICROMODULYO Freeze Dryer


This item was removed from a facility where it was surplus to requirement.


The unit powers on, however, the temperature switch indicator never illuminated, even after approximately 2 hours of operation.


The system also failed to achieve its maximum cooling temperature during testing.


Due to these faults, the unit is being sold for spares or repair.

Image of Thermo Scientific SORVALL RC 6+ Centrifuge

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific SORVALL RC 6+ Centrifuge

ITEM-49704

Thermo Scientific SORVALL RC 6+ Centrifuge


This item was removed from a facility where it was surplus to requirement.


The unit powers on and was able to cool down to 4°C during testing; however, a noticeable electrical burning smell developed during operation.


The start capacitor became excessively warm and there appears to be an issue relating to the cooling system circuitry, possibly involving a faulty relay or capacitor control fault.


Due to these faults, the unit is being sold for spares or repair.

Image of Sorvall RC-6 Plus Floor Standing Centrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Sorvall RC-6 Plus Floor Standing Centrifuge Lab

ITEM-52688

Sorvall RC-6 Plus Floor Standing Centrifuge


This item was removed from a facility where it was surplus to requirement.


The unit powers on but displays alarm “E38”. The onboard information menu advises that alarms E10–E95 are intended for service personnel, therefore no further fault information could be obtained.


Please note that the centrifuge arrived with several internal connections unplugged.


Due to this fault, the unit could not be fully tested and is therefore being sold for spares or repair.

Image of Thermo Scientific Microliter 48 x 2 mL Sealed Aluminum Fixed Angle Rotor

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific Microliter 48 x 2 mL Sealed Aluminum Fixed Angle Rotor

ITEM-54954

Thermo Scientific Microliter 48 x 2 mL Sealed Aluminum Fixed Angle Rotor


This item was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition.

Image of Leica CM 1850 Cryostat Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Leica CM 1850 Cryostat Lab

ITEM-52338

Leica CM 1850 Cryostat Spares/Repair Lab


This system was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition and powers on, however, during testing it failed to cool.


Therefore, it is listed as Spares/Repair.

Image of Thermo Electron Forma Series II Water Jacketed CO2 Incubator 3141 Lab

£ 500.00 (ex. VAT) 1 in stock

Thermo Electron Forma Series II Water Jacketed CO2 Incubator 3141 Lab

ITEM-30453

This Thermo Electron Forma Series II Water Jacketed CO2 Incubator 3141 was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order.


It is in reasonably good cosmetic condition with some marks from use. It is missing two feet on the right-hand side, but we can replace these on sale.


2 Shelves - 47 x 47cm



Image of Sanyo C02 Incubator Model MC0-175 Lab

£ 500.00 (ex. VAT) 1 in stock

Sanyo C02 Incubator Model MC0-175 Lab

ITEM-37592

Sanyo C02 Incubator MC0175


This item was removed from a university where it was surplus to requirement.


The unit powers up and is in good working order (thermometer & co2 analyser not included).


It is in reasonably good cosmetic condition, however there is some rust visible and the control cover hinge has broken.


The door seal and latch are both in good cosmetic condition.


This item includes 4  x Shelves and a Humidity Pan.

Image of Liebherr GKPv 6522  Glass Fronted Fridge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Liebherr GKPv 6522 Glass Fronted Fridge Lab

ITEM-46622

Liebherr GKPv 6522 Glass Fronted Fridge - Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on, however, during testing it failed to cool beyond 13ºc when set to 1ºc.


Therefore, it is listed as Spares/Repair.

Image of Grant FH15 Flow Heater and FC20 Flow Cooler Lab

£ 500.00 (ex. VAT) 1 in stock

Grant FH15 Flow Heater and FC20 Flow Cooler Lab

ITEM-42784

Grant FH15 Flow Heater and FC20 Flow Cooler


This system was removed from a university laboratory where it was surplus to requirements.


The FH15 Flow Heater powered on with the pump running. The heater light illuminated when the set temperature was increased above ambient.

The FC20 Flow Cooler powered on, and both the compressor and fan could be heard operating.


These units do not include a built-in tank and require an external header tank to function as part of a complete system. Due to this, full-range temperature testing was not performed.

It is in good cosmetic condition.


Includes:

  • Grant FH15 Flow Heater (Serial No. 72311)
  • Grant FC20 Flow Cooler (Serial No. 72311)

  • Model: FH15 / FC20
  • Serial No.: 72311
Image of LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab

£ 500.00 (ex. VAT) 1 in stock

LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab

ITEM-42425


LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab


This item was removed from a university lab where it surplus to requirement.


It is good cosmetic condition and good working order.

Image of Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker

£ 500.00 (ex. VAT) 1 in stock

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker

ITEM-46240

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker


This item was removed from a laboratory where it was surplus to requirements.


The shaker powers on and operates at the maximum RPM of 400. It is in reasonably good cosmetic condition.


Model: AK-82

Image of Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker  Lab

£ 500.00 (ex. VAT) 1 in stock

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker Lab

ITEM-46239

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker


This item was removed from a laboratory where it was surplus to requirements.


The shaker powers on and operates at the maximum RPM of 400.

It is in poor cosmetic condition.


Model: AK-82

Image of Triple Red Duo Organic 60 Ultra Pure Water Purification System Lab

£ 500.00 (ex. VAT) 1 in stock

Triple Red Duo Organic 60 Ultra Pure Water Purification System Lab

ITEM-45397

Triple Red Duo Organic 60 Ultra Pure Water Purification System


This item was removed from a university where it was surplus to requirements.


It is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.


Included Components:

  • Avidity Carbon Pre-Filter
  • P/N: TR-2057
  • Install Date: 26/7/23
  • Avidity Cartridge Pack
  • P/N: TR-2050
  • Install Date: 26/7/23
  • Avidity Cartridge Polisher
  • P/N: TR-2051
  • Install Date: 26/7/23

Specifications:

  • Model: Organic 60 Ultra Pure Water Purification System
  • Serial No.: 0916961-01

Image of Beckman Optima TL Ultracentrifuge w/ Beckman TLA 100.4 Rotor

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Beckman Optima TL Ultracentrifuge w/ Beckman TLA 100.4 Rotor

ITEM-42968

Beckman Optima TL Ultracentrifuge


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in good cosmetic condition with minimal wear. However, the unit is non-operational: it does not run programs or operate normally. The door does not open unless the unit is manually stripped down and the door lock pin is pressed.

Additionally, the vacuum chamber does not hold pressure. Error messages displayed include CPU, VAC, and SPD.


Therefore, it is listed as Spares/Repair.


Includes:

  • Rotor: Beckman TLA 100.4
  • Maximum Speed: 100,000 RPM
  • Serial No.: 95U1272

Model: TL

Serial No.: CTL95E13

Image of Job Lot of 13 Vintage Microtome Knives With Sharpening strops and Whetstones

£ 500.00 (ex. VAT) 1 in stock

Job Lot of 13 Vintage Microtome Knives With Sharpening strops and Whetstones

ITEM-42018

Job Lot of 13 Vintage Microtome Knives With Sharpening Strops and Whetstones


These items were removed from a university lab, where they were surplus to requirement.


The knife blades are all in very good condition, with sharp and undamaged cutting edges, appearing to have been well maintained, except for the hand knife, which has a poor cutting edge.


The wooden boxes are in excellent condition, except for two that are damaged.


The lot comprises:


  • 3 x Shandon Nothung C wedge shape 20cm blades (circa 1967) in box
  • 1 x Shandon Northung A concave 25cm blade (circa 1967) in box
  • 1 x Unidentified C wedge 18cm blade in box
  • 3 x MSE Ltd No. 9057.W wedge 9cm blades in box
  • 2 x Cambridge Instruments rocking microtome knives (10cm blades) in box
  • 1 x Unidentified wedge 8cm blade in leather case
  • 1 x Hand knife with handle in poor condition in box
  • 4 x Leather sharpening strops (30-35cm long), 2 in box
  • 2 x 15cm whetstones
  • 1 x Acrylic 15cm sharpener
  • 1 x 25cm blade holder
  • 3 x 20cm blade holders
  • 1 x 17cm blade holder
Image of Leica Cryocut 1800 Reichert-Jung CM1800 Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Leica Cryocut 1800 Reichert-Jung CM1800 Lab

ITEM-37479

Leica Cryocut 1800 Reichert-Jung CM1800 Microtome Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in reasonably good cosmetic condition and in good mechanical order, however it failed the PAT on insulation.


Therefore, further testing could not be conducted and it is listed as Spares/Repair.


Specifications:

  • Cat No. 042019409
  • Serial No. 25320449
Image of Agilent N2-14-K727 5183-2003 Nitrogen Gas Generator Lab

£ 500.00 (ex. VAT) 1 in stock

Agilent N2-14-K727 5183-2003 Nitrogen Gas Generator Lab

ITEM-40059

This Agilent 5183-2003 Nitrogen Gas Generator was removed from a university lab where it was surplus to requirements.


The system has not been tested at our facility. It is in good cosmetic condition with marks from use.


The lab confirmed it was in good working order prior to removal.

Image of Parker Dominick Hunter LCMS30-1 Nitrogen Gas Generator

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Parker Dominick Hunter LCMS30-1 Nitrogen Gas Generator

ITEM-47640

Parker Dominick Hunter LCMS30-1 Nitrogen Gas Generator Spares/Repair


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however, the display screen does not power on.


Therefore, it is listed as Spares/Repair.

Image of Stuart SSL2 Reciprocating Laboratory Shaker Lab

£ 500.00 (ex. VAT) 1 in stock

Stuart SSL2 Reciprocating Laboratory Shaker Lab

ITEM-51517

Stuart SSL2 Reciprocating Shaker


This item was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.

Image of Elementar 2-Tube Furnace Lab

£ 500.00 (ex. VAT) 1 in stock

Elementar 2-Tube Furnace Lab

ITEM-54287

Elementar 2-Tube Furnace Lab


This item was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition, we are unable to test it further at our facility.


Image of Moffat Blue Seal Turbofan E23M3 Oven

£ 500.00 (ex. VAT) 1 in stock

Moffat Blue Seal Turbofan E23M3 Oven

ITEM-50970

Moffat Blue Seal Turbofan E23M3 Oven


This item was removed from a facility where it was surplus to requirement.


The oven powers on and successfully reached its maximum rated temperature of 250°C during testing.


Please note that the unit produces noise consistent with worn motor bearings. The bearings may require replacement, or the motor assembly may need attention.


For this reason, we recommend that the oven is serviced prior to use.

Image of Liebherr Mediline LKexv 3910 Laboratory Refrigerator

RECERTIFIED ITEM

RECERTIFIED ITEM

£ 500.00 (ex. VAT) 1 in stock

Liebherr Mediline LKexv 3910 Laboratory Refrigerator

ITEM-51298

Liebherr Mediline LKexv 3910 Laboratory Refrigerator


This item was removed from a facility where it was surplus to requirement.


It is in good working order.


Image of Thermo Fisher Scientific TSX2320FV Laboratory Freezer Lab

£ 500.00 (ex. VAT) 1 in stock

Thermo Fisher Scientific TSX2320FV Laboratory Freezer Lab

ITEM-39039

Thermo Fisher Scientific TSX2320FV Laboratory Freezer Lab


This item was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order. It was tested with a digital thermometer (not included).


It is in great cosmetic condition.


Key included.

Image of Barnstead GeneVac MiVac DNA Concentrator Lab

£ 500.00 (ex. VAT) 1 in stock

Barnstead GeneVac MiVac DNA Concentrator Lab

ITEM-39129

Barnstead GeneVac MiVac DNA Concentrator


This item was removed from a university lab where it was surplus to requirements.


The unit powers up and is in full working order. It was tested with a digital thermometer (not included).


It is in good cosmetic condition.


48-well aluminium rotor which holds:

1.5/2ml centrifuge tubes

Image of Huber TC125-MT Immersion Cooler 16amp 5-Pin

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Huber TC125-MT Immersion Cooler 16amp 5-Pin

ITEM-50100

Huber TC125-MT Immersion Cooler


This item was removed from a facility where it was surplus to requirements.


The unit powers on; however, we are advised it was not working at the point of removal. It has not been further tested by us, and the exact fault is unknown.


It is therefore listed as Spares/Repair.

Image of Miele Professional G 7881 Glassware Washer

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Miele Professional G 7881 Glassware Washer

ITEM-55615

Miele Professional G 7881 Glassware Washer


This item was removed from a facility where it was surplus to requirement.


The unit is able to complete a rinse cycle and drain correctly, however, heated programs trigger an F26 Boiler Protection Error.


Due to this fault, the unit is being sold for spares or repair.

Image of Lot Of Heraeus Centrifuge Rotor Buckets & Adapters #7570 E #8030 Lab

£ 500.00 (ex. VAT) 1 in stock

Lot Of Heraeus Centrifuge Rotor Buckets & Adapters #7570 E #8030 Lab

ITEM-41487

Lot Of Heraeus Centrifugal Rotor Buckets And Tube Holder Bucket Inserts Lab


These items were removed from a university lab where they were surplus to requirement.


All items are in good cosmetic condition but have not been tested.


The items included are as follows:


  • 4 x Heraeus #7570 E Rotor Buckets (max capacity of 600g)
  • 3 x Heraeus #8030 Rotor Buckets (max capacity of 510g)
  • 3 x Tube Holders For 15-25ml Tubes
  • 4 x Tube Holders 50ml Tubes



Image of MSE 4 x 750ml Windshield Rotor 43124-708 BS4402 with Buckets Lab

£ 500.00 (ex. VAT) 1 in stock

MSE 4 x 750ml Windshield Rotor 43124-708 BS4402 with Buckets Lab

ITEM-42469

MSE 4 x 750ml Windshield Rotor 43124-708 BS 4402 With Buckets


This item was removed from a university laboratory where it was surplus to requirements.


The rotor is in very good condition. It was tested on a compatible centrifuge at its maximum speed of 3660 RPM and operated without issues.


Includes:

  • 4 x 750ml MSE buckets

Model: 43124-708 BS 4402

Serial No.: 872183

Max RPM: 3660

Year: 1987

Image of Radiometer Analytical TIM856 Titration Manager Lab

£ 500.00 (ex. VAT) 1 in stock

Radiometer Analytical TIM856 Titration Manager Lab

ITEM-52346

Radiometer Analytical TIM856 Titration Manager Lab


This item was removed from a facility where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The previous owner stated it was in working order prior to removal.

Image of BioDot Liquid Dispense System - Model 3000

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

BioDot Liquid Dispense System - Model 3000

ITEM-58101

BioDot Liquid Dispense System - Model 3000


This item was removed from a facility where it was surplus to requirement.


The unit failed PAT testing due to an insulation resistance fault.


Due to this fault, the system is being sold for spares or repair.

Image of Mettler Toledo Coulometer DL32 Titrator Lab

£ 500.00 (ex. VAT) 1 in stock

Mettler Toledo Coulometer DL32 Titrator Lab

ITEM-52352

Mettler Toledo Coulometer DL32 Titrator Lab


This item was removed from a facility where it was surplus to requirement.


The previous owner stated it was in working order prior to removal.


Please note: The power supply is not included.

Image of Thermo Scientific Versette Automated Liquid Handler Lab

£ 500.00 (ex. VAT) 1 in stock

Thermo Scientific Versette Automated Liquid Handler Lab

ITEM-38433

Thermo Scientific Versette Automated Liquid Handler


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition, with 2 noticeable cracks present.


This item powers on, we are unable to conduct further testing at our facility.


This item was last serviced by a Thermo Scientific Engineer in April 2022.

Items 701 to 750 of 1294

Filters

Price (£)

to

Condition