Inverted and Fluorescence Microscopes
Items 1 to 50 of 86
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 16,000.00 (ex. VAT) 1 in stock
Zeiss Axio Observer 3 Inverted Microscope w/ 3 x EC Plan-NEOFLUAR Objectives
ITEM-36487
This Zeiss Axio Observer 3 Inverted Microscope w/ 3 x EC Plan-NEOFLUAUR Objectives was removed from a university lab where it was surplus to requirements.
The system has been professionally serviced. It is in full working order. The camera has been tested with free Zeiss Zen Lite software and is in full working order.
It is in good cosmetic condition with marks from use.
Item contains the following:
3 x Objectives
Zeiss EC Plan-NEOFLUAUR
2,5x/0.085
420320-9902
Zeiss EC Plan-NEOFLAUR
5x/0,16Ph1
∞/0,17
420331-9911
Zeiss EC Plan-NEOFLAUR
10x/0,3Ph1
∞/-
420341-9911
HAL 100 Lamp
Serial#: 423000-9901
Axiocam ERc 5s
Serial#: MHG7646
Carl Zeiss PI 10x/23 Eyepies (Qty. 2)
Serial#: 444036-9000
Original Zeiss Dust Cover
Dell Optiplex 7010 PC system running Windows 10.
A copy of Zeiss ZEN Lite has been installed. This is the free version of ZEN.
The buyer is able to set up an account with Zeiss and purchase premium versions of the software if they wish.
The Zeiss microscopy downloader software is also installed. This allows you to download various Zeiss microscopy software to meet your needs.
£ 14,500.00 (ex. VAT) 1 in stock
Olympus BX51WIF Fluorescence Microscope System w/ Newport Optics Table Lab
ITEM-30182
This Olympus BX51 WIF Fluorescence Microscope System was removed from a university lab where it was surplus to requirements.
The System unfortunately is largely untested as the lab was unable to part with the PC and software. They implied that it was in working order prior to having the PC removed as it was just surplus to requirements, but there are some parts missing.
Overall it is in good cosmetic condition but has general marks from use.
Details;
1 x Olympus Microscope
Model - BX51WIF
2 x Olympus Eye pieces - WH15X/14
2 x Objectives:-
Olympus LUMPlanFI/IR 40x/0.80 W ∞/0
Olympus Plan N 4x/0.10 ∞/-/FN22
Olympus Lamp
Model U-LH100IR
SN - 6F24822
There is no power supply for the lamp, we used one from another item (not included) to test the light which was working, tested with one of our slides and was able to focus.
Q Imaging optiMOS sCMOS camera
Cooled Mono 16 Bit
SN - Q41501
Lens - Olympus U-CMAD3/Olympus U-TV1X-2
Filter - HQ535/50 M 203616
There is no power supply cable for the camera.
Newport RG Breadboard Optics Table
Model - VH3036W-OPT
Dimensions - D76 W90 H80cm
Faraday Cage Dimensions - D78 W88 H90cm
The cage is in reasonable condition but has a few holes.
Table & Cage combined dimensions - D77 W90 H170cm
Scientifica Stage/Platform
Dimensions - D34.5 W60.5 H20.5cm
Power supply for Patch Clamp Micromanipulation System:-
Burleigh PCS-PS60
Powers on
2 x Burleigh PCS 5000 Series Controllers
SN - 0011431 & 0011420
2 x Burleigh PCS 5000 Series Micromanipulators
Burleigh TS - 5000 - 150
Other parts/accessories include:-
Unknown Part SN - 1270
Prior part
Hi-lo Nitrogen 10 Bar gas Regulator
Various small bits including crocodile clips and tubing
£ 10,000.00 (ex. VAT) 1 in stock
ZEISS PALM CombiSystem Axiovert 200M, XE120-XL,HV-D30P w/ Parts & Accessories
ITEM-39769
ZEISS PALM CombiSystem Axiovert 200M, XE120-XL,HV-D30P w/ Parts & Accessories
This was removed from a university lab where it was surplus to requirements.
The system powers up and the microscope is in good working order. We had some issues controlling the camera and the stage during testing, but this may be due to user error.
With the Palm RoboSoftware V4 we can control the following microscope features:
- Stage Y Axis movement
- Stage X Axis movement
- Objective Motor (able to select objective)
- Increase/Decrease Light
- Change Light Source
- Raise/Lower Objective
It is in excellent cosmetic condition with minor marks.
Included are the following;
Carl Zeiss Axiovert 200M
Model: Axiovert 200M
Serial#: 3820005950
Objectives fitted:
Zeiss Fluar 5x/0.25
Zeiss Fluar 10x/0.50
Zeiss LD Plan-Neoflaur 20x/0.40 Corr
Zeiss LD Plan-Neoflaur 40x/0.60 Corr
Zeiss EC Plan-Neoflaur 63x/1.25 Oil M27
Zeiss EC Plan-Neoflaur 100x/1,30 Oil
Eyepieces:
W-PL 10x/23 (Qty.2)
P.A.L.M Microlaser Technologies
Model: PALM CombiSystem
Serial#: CSC-01010
Date: 2007
Fujitsu Siemens Celsius R630 PC, Fujitsu Siemens SCIENVIEW B17-2 C CI Monitor (QTY.2) Fujitsu Siemens Keyboard, Mouse
Model: Celsius R630
Serial#: YKFU009307
Both Monitors, PC, Keyboard and Mouse are in good cosmetic condition and power on with no issue.
PC has the following software installed:
Palm RoboSoftware V4
Hitachi HV-D30 Camera
Model: HV-D30P
Serial#: 0675280
Laser Quantum LD3000 power supply
Model: Forte
Serial#: 02165
p
Zeiss CryLaS FTSS 355-50
Serial#: B594C279
Item powers on and is in full working order.
Communicates with control panel and microscope.
EXFO X-Cite Series 120
Model: XE120-XL
Serial#: 0570
Item is in good cosmetic condition.
Item powers on with light source in full working order.
All items listed above are sat on a Melles Griot Optical Table with PALM CombiSystem being fixed to it.
Measurements and weight of Melles Griot Optical Table are as follows:
Dx120Wx90Hx77cm
Weight:
Additional Parts & Accessories:
Zeiss AdhesiveCap 500 Clear
PALM MembraneSlides
PALM CombiSystem C User Manuals
PALM DishHolder 50 C
PALM MultiCap Insert 8c
PALM MultiCap Collector D 8C (Qty.2)
PALM CollectorSet SingleTube II 500
PALM CombiSystem User manual (Qty.2)
PALM RoboSoftware Software Guide (Qty.2)
Laser Quantum Forte Operating Manual
PALM MicroBeam Technical Information
Zeiss Axiovert 200 Operating Manual
Zeiss DuplexDish 50 Sterile Packed (Qty.6)
LumoxTM Dish 50 Hydrophilic, Sterile (Qty.5)
Zeiss MembraneSlide 1.0 Pen
X-Cite In Control Series 120 User's Guide
Zeiss PALM RoboSoftware CD
PALM MicroLaser System RoboSoftware 4.0 CD
Fujitsu Siemens Product Recovery CD
Carl Zeiss 29 Software Release 4.6
Zeiss Axiovert 200 M/Mat Floppy Disc
3-CCD Color Camera Model HV-D30 Operating Manual
Fujitsu Siemens Celsius Drivers & Utilities CD
Scenview B17-2 CI / B19-2 CI
£ POA 1 in stock
PALM Laser Microscope Microlaser MicroBeam Zeiss Axiovert 200M P.A.L.M Lab
ITEM-40041
This item is new in stock. Please enquire for further details.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ POA 1 in stock
Olympus IX70 Inverted Fluorescence Microscope w/ U-ULS100HG
ITEM-40045
This item is new in stock. Please enquire for further details.
£ 5,000.00 (ex. VAT) 1 in stock
Zeiss Axio Vert.A1 FL Inverted Transmitted Light Microscope Lab
ITEM-31570
Zeiss Axio Vert.A1 FL Inverted Microscope
This system was removed from a university lab where it was surplus to requirements.
The microscope is in very clean cosmetic condition. Four 27mm to RMS adapters have been fitted, allowing the use of standard RMS objectives. The microscope has been tested with an objective from stock and works as expected, though no objectives are currently fitted.
The instrument is configured as follows:
- 1 x Microscope stand Axio Vert.A1 FL (431030-9010-000)
- Nosepiece 2xH / 3xHDIC M27 and carrier for transmitted-light illumination
- Reflector modules: DAPI, FITC, TRITC, empty
- 1 x LD condenser 0.55 for H Ph PlasDIC DIC (424228-9030-000)
- Position 1: empty
- Position 2: 424228-9060 0.05T Neutral density filter 0.05
- Position 3: 426717-9170 Ph1/0.55 Phase stop Ph1/0.55
- Position 4: 426717-9180 Ph2/0.55 Phase stop Ph2/0.55
- Position 5: empty
- 1 x Illuminator LED for Axio Vert transmitted light (423004-9020-000)
- 1 x Stop slider A 14x40mm with aperture/luminous field diaphragm (423730-9151-000)
- 1 x Binocular tube 45º/23 (425523-9000-000) with 2 x 444036-9000 eyepieces PI 10x/23
- 1 x Mirror 100%, 26x36mm (452531-0001-010) with intermediate phototube H=50mm, left port (425146-9030-000)
- 1 x Camera adapter 60N-C 2/3" 0.5x (426112)
- 1 x Ergo Intermediate piece H=50mm for optimization of viewing height (425146-9040-00)
- 1 x Specimen stage 232x230mm with hardcoat anodized surface (432037-9000-000)
- Object guide M, 130x85mm, for Axio Vert (432333-9040-000)
- 1 x QImaging QIClick Camera (01-QIClick-R-F-CLR-12), Colour 12 Bit, Firewire operation
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 4,485.00 (ex. VAT) 1 in stock
Olympus IX50/Arcturus LCM2106 PixCell 2E Microdissection Microscope System
ITEM-19538
This Olympus IX50/Arcturus LCM2106 PixCell 2E Microdissection Microscope System was removed from a university lab where it was surplus to requirements.
All parts are in good used cosmetic condition but they do have signs of general use. We have powered it all up and the system appears to function as it should. We were able to view a slide via the software on the PC.
It is an excellent system and is in full working order. It has been professionally serviced. The comments from the service engineer are below.
It appears to be in good working condition but we have no way of checking the laser. The internal halogen works fine and so does the external metal halide illumination. Objectives UPlanFl 4x/0.13 ∞/- UPlanFl 10x/0.30 ∞/- LCPlanFl 20x/0.4 ∞/- LCPlanFl 40x/0.60 ∞/- Diagnostic Inst 1x C Mount adaptor. Some evidence of bleaching of fluorescence filters.
The system consists of:
1 x Olympus IX50 Microscope Modified by Arcturus.
With PixCell IIE LCM2016 Laser System (Manufactured September 2002).
The microscope is fitted with:
2 x Olympus WH10X/22 Eyepieces.
Olympus Objectives:
1 x Olympus
LCPlanFl
40x/0.60
∞/
1x Olympus
LCPlanFl
20x/0.40
∞/
1 x Olympus
UPlanFl
10x/0.30
∞/
1x Olympus
UPlanFl
4x/0.13
∞/-
1 x ZEISS
Plan-NEOFLUAR
40x/0.75
∞/0.17
(not fitted in the microscope).
1 x Dell Dimension 3000 PC with keyboard, mouse & monitor.
The PC has Arcturus ARC200 software installed and is fitted with a PCi card interface for the Hitachi camera.
1 x Olympus BH2-RFL-T3 Lamp PSU.
It is showing 71.2 lamp hours.
1 x Olympus U-ULS100HG 100w lamp
1 x Hitachi KP-D590P CCD Color Camera.
1 x Camera Remote Unit.
1 x Arcturus PixCell IIe Control Unit.
1 x MARX Crypto-Box.
1 x Arcturus 12109-00D Sample holder.
Various cables to connect the whole system.
Manuals.
£ POA 1 in stock
Zeiss Axioskop 2 Plus Microscope With FluoArc Power Supply Lab
ITEM-44616
This item is new in stock. Please enquire for further details.
RECERTIFIED ITEM
RECERTIFIED ITEM
£ POA 1 in stock
Nikon Eclipse E800 Microscope System w/ Plan Apo 40/60/100, V-PS100E Lab
ITEM-36004
This item is new in stock. Please enquire for further details.
£ 3,800.00 (ex. VAT) 1 in stock
Nikon Eclipse TE300 Inverted Fluorescence Microscope System w/ 20x/0.50 Ph1 Lab
ITEM-36255
Nikon Eclipse TE300 Inverted Fluorescence Microscope System Lab
This was removed from a university lab where it was surplus to requirements.
This system is in good cosmetic condition with all included units in working order.
1 x Nikon Eclipse TE300 body fitted with:
1 x Nikon 065851 multi position binocular neck.
1 x Nikon manual stage.
1 x Nikon filter holder, no filters fitted.
1 x Nikon Condenser Turret fitted with 1 x LWD ∞ Ph3 & 1 x Blanking plate.
The other 3 blanking plates are missing.
1 x Nikon LWD 0.52
2 x Nikon CFI 10x/22 eyepieces.
1 x Nikon Plan Flour
20x/0.50
Ph1 DLL
Objective.
1 x Nikon LHS-H100P-1 Halogen 12v 100w Lamp.
1 x Nikon TE-PSE100 Power supply with control cable.
1 x Nikon LH-M100C-1 Mercury 100w Lamp. (Run hours not known, bulb will require replacement).
1 x Nikon C-SHG1 Power Supply. (Run time counter reset).
£ 3,500.00 (ex. VAT) 1 in stock
Leica DMR Type 020-525.735 Fluorescence Microscope Lab
ITEM-41444
Leica DMR Type 020-525.735 Fluorescence Microscope Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on with the bottom-mounted lamp in good working order.
We are unable to test the top-mounted lamp as the required power supply is not included.
Includes with the microscope are the following:
- Leica MPS 60 Camera
- Leica ∞/0.17 C Plan 100x/1.25 Oil Objective
- Leica ∞/-/A N Plan 5x/0.12 Objective
- 504058 Leica Illuminator
- Leica 807-072.057 Lamp Module (damaged)
- Box of misc tools and accessories
£ 3,500.00 (ex. VAT) 1 in stock
Zeiss Axioplan 2ie MOT Fluorescence Microscope w/ 4 Objectives (Neofl, Achrom)
ITEM-36333
Zeiss Axioplan 2 Fluorescence Microscope
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. It is in good cosmetic condition with minor marks.
It is made up of the following modules;
Carl Zeiss Axioplan 2 Fluorescence Microscope
S/N: 3511001506
Eyepieces:
2 x Zeiss Pl 10 x 25
P/N: 44 40 34
1x 6 position nosepiece, fitted with 4 objectives:
1x Zeiss Plan-NEOFLUAR 40x/0.75 ∞/0.17
P/N: 44 03 50 02
1x Zeiss EC Plan-NEOFLUAR 100x/1.30 oil ∞/0.17
P/N: 440480-9903
1x Zeiss APOCHROMAT 10x/0.45 ∞/0.17
P/N: 1063-139
1x Zeiss EC Plan-NEOFLUAR 63x/1.25 oil ∞/0.17
P/N: 440460-9904
All additional parts:
1x Zeiss Reflector Turret 322 Synchroflex T 2.5 5/500 with 8x filters:-
1x BF
1x S Gr 1
1x DAPI
1x Tex Red
1x S Or
1x S Aqua
1x Cy5
1x Cy5.5
1x Marzhauser Scan8 Mechanical/Motorised Stage:
P/N: 42-24-407-0000
S/N: 03110373
1x Princeton Instruments Digital Camera
M/N: RTE/CCD-1300-Y/ES
S/N: M059850 7360-01-19
1x Princeton Instruments MicroMax Camera System:
M/N: ST-133
S/N: M059849
1x Carl Zeiss HBO 100 lamp house
P/N: 1007-980
1x Carl Zeiss HAL 100 12v 100w lamp house
P/N: 1039-685
1x LEJ ebq 100 lamp power supply showing 2650 hours of use
S/N: N01415645
2x Iris Stop Slider
P/N: 1062-360
3x Connection cables
1x Zeiss microscope cover
£ 3,150.00 (ex. VAT) 1 in stock
Leica DMIRB Inverted Microscope With 6 Objectives & EBQ 100 PSU Lab
ITEM-42028
Leica DM IRB Inverted Microscope with 6 Objectives & EBQ 100 PSU
This item was removed from a university lab where it was surplus to requirements.
The microscope powers on and is in great condition with no visible wear. It has been tested with multiple slides and different filters, and includes six objectives. The EBQ 100 isolated power supply also powers on and is in good condition with minimal wear. We are unable to test it further at our facility.
This microscope comprises the following:
- Model: DM IRB
- Type: 090-134.010-000
- Serial No.: 888212 254578
- Leica DC 300F Camera
- Type: DC 300F (12447115)
- Input: 12V / 600mA
- Serial No.: 11552003
Objectives:
- Leica 506090
- 5x PH 0, ∞ / - / A, N PLAN, 5x / 0.12, PH 0
- Leica 506088
- 10x PH 1, ∞ / - / A, N PLAN, 10x / 0.25, PH 1
- Leica 506202
- N PLAN, L 20x / 0.40, CORR PH 1, ∞ / 0-2 / C
- Leica 506060
- N PLAN, L 40x / 0.55, CORR PH 2, ∞ / 0-2 / C
- Leica 506062
- PL FLUOTAR, L 63x / 0.70, CORR PH 2, ∞ / 0.1 - 1 .3 / C
- Leica 506159
- 100x PH 3, ∞ / - / D, N PLAN, 100x / 1.25 Oil, PH 3
EBQ 100 Isolated PSU:
- Type: ebq 100 isolated - L / 131.26E
- Serial No.: N 19419356
£ 3,050.00 (ex. VAT) 1 in stock
Leica DMIRB Inverted Microscope With 5 Objectives & EBQ 100 PSU Lab
ITEM-42037
Leica DM IRB Inverted Microscope with 6 Objectives & EBQ 100 PSU
This microscope was removed from a university lab where it was surplus to requirements.
It powers on and is in great condition with no visible wear. It has been tested with multiple slides and includes six objectives. The unit has passed PAT testing.
The microscope comprises the following:
- Leica DM IRB Inverted Microscope
- Leica DC 200 FireWire colour camera
- EBQ 100 PSU
Objectives:
- Leica 506090
- 5x PH 0, ∞ / - / A, N PLAN, 5x / 0.12, PH 0
- Leica 506088
- 10x PH 1, ∞ / - / A, N PLAN, 10x / 0.25, PH 1
- Leica 506058
- N PLAN, L 20x / 0.40, CORR PH 1, ∞ / 0-2 / C
- Leica 506060
- N PLAN, L 40x / 0.55, CORR PH 2, ∞ / 0-2 / C
- Leica 506062
- PL FLUOTAR, L 63x / 0.70, CORR PH 2, ∞ / 0.1 - 1.3 / C
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 3,000.00 (ex. VAT) 1 in stock
Nikon Eclipse E800M Fluorescence Microscope Lab
ITEM-25095
This Nikon Eclipse E800M Fluorescence Microscope was removed from a university lab where it was surplus to requirements.
The system has been professionally serviced and is in good working order. A full report is available on request.
1x Nikon Eclipse E800:
Model C-LP
The unit powers on and is in good cosmetic condition.
There is some dust and dirt from general use.
S/N0183376
2x Nikon CFIUW 10/25 eyepieces.
1x Nikon Macro Slider
S/N 660048
1x Nikon Eclipse EH-21
8.4 volt / power supply for
Nikon Coolpix 995 Camera
Nikon Battery Charger
S/N E141988
1x Nikon Microscope Power Supply:
Model V-PS100E
The unit powers on and is in good condition.
S/N 603313
1x Nikon Coolpix Camera:
Model 995
The unit powers on and is in good cosmetic condition.
No battery supplied with the unit.
No memory card supplied with the unit.
S/N 4516080
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 3,000.00 (ex. VAT) 1 in stock
Olympus BX61 Microscope With BX-UCB Control Lab Spares/Repairs
ITEM-34598
Olympus BX61 Microscope With BX-UCB Control
This item was removed from a university where it was surplus to requirement.
The microscope is in good cosmetic condition and powers on, we are unable to test it further due to it not including a stage to hold a sample stage.
Because the BX-UCB does not power on and the lack of stage, this item is listed as Spares/Repair.
All items included in the listing are as follows:
1 x Olympus Model: BX61TRF
Serial No. 7J20591
1 x Olympus Model: BX-UCB
Serial No. 7M15089
1 x Olympus Light Unit U-LH100-3
Serial No. 7M15089
1 x PlanApo N 1.25 x/0.04 FN26.5.
1 x PlanApo N 60 x/1.42 oil 0.17/FN26.5.
1 x UPlanSApo 100x/1.40 oil 0.17/FN26.5.
1 x Uplan FLN 10x/0.30 FN 26.5.
2 x Olympus WHN10x/22 Eyepiece.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 2,500.00 (ex. VAT) 1 in stock
Carl Zeiss Axiovert 200M Inverted Microscope Spares/Repairs
ITEM-34769
Carl Zeiss Axiovert 200M Inverted Microscope
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has faults.
Faults;
- Unable to move the stage with onboard or mechanical controls, therefore, unable to focus on the slide.
- The display is illuminated but shows no text.
- No cable for PALM joystick control
The automated functions that work are;
- Light increase/decrease
- Filter selection
- Objectives selection
- Optical view selection
Included are;
2 x Eye Pieces: W-Pl 10x/23 (1016-758)
3 x Objectives:-
1x Zeiss FLUAR 5x/0.25 ∞/0.17 (44 01 25)
1x Zeiss Ph3 Plan-NEOFLAUR 100x/1.30 oil ∞/0.17 (1066-987)
1x Zeiss LD ACHROPLAN 63x/0.75 Korr Ph2 ∞/0.17 Ph2 (44 08 61)
1x P.A.L.M Microlaser Technologies Joystick Controller.
1x Zeiss Lamp Power supply - HBO 100W 1003-928 (426-784)
S/N: N 01415621
Powers on.
Unit is displaying 140.10 Hrs
£ 2,470.00 (ex. VAT) 1 in stock
Nikon Eclipse 50i Microscope w/ 3 Objectives & Mikrotron EoSens MC1362
ITEM-39862
Nikon Eclipse 50i Microscope
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order, though we were unable to test the camera without the software.
It is in good cosmetic condition with minor marks.
Item includes the following:
Nikon CFI 19x/22 Eyepiece x 2
Nikon Plan 100x/1.25 Oil Ph3 DL
∞/0.17 WD 0.2
Nikon Plan 20x/0.40 Ph1 DL
∞/0.17 WD 1.2
Nikon Plan 40x/0.65 Ph2 DL
∞/0.17 WD 0.56
LV-TT2 Trinocular Tube
Mikrotron EoSens MC1362
Serial#: 00704
£ 2,250.00 (ex. VAT) 1 in stock
Nikon Eclipse TE200 w/ 2 x Objectives Ph1 10x, Ph2 40x Lab
ITEM-37538
Nikon Eclipse TE200 w/ 2 x Objectives Ph1 10x, Ph2 40x
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks.
Item includes the following:
Nikon Plan 40X/0.65 Ph2 DL ∞ 0.17 WD 0.57
Nikon Plan 10X/0.25 Ph1 DL ∞/ - WD 10.5
£ 2,000.00 (ex. VAT) 1 in stock
Zeiss Axioskop FS Fluorescence Microscope w/ 5 x Objectives Achropl, Epiplan Lab
ITEM-38100
Zeiss Axioskop FS Fluorescence Microscope w/ 5 x Objectives
This was removed from a university lab where it was surplus to requirements.
The product has not been tested due to the absence of its power supply, but it is in good condition with minimal signs of wear.
Due to the power supply not being included, we are unable to test further.
Includes the following untested objectives;
Gallenkamp 160/0.17 100 1.25 oil
Zeiss Achroplan 10x/0,25 ∞/-
Zeiss Epiplan 50x/0,50 44 28 50
Zeiss LD Achroplan 32x/0,40 PH2 ∞/1,5
Zeiss Achrostigmat 5x/0,12 44 01 20
£ 2,000.00 (ex. VAT) 1 in stock
MOTIC AE31 Series Inverted Microscope with 4 x Objectives Lab
ITEM-41303
MOTIC AE31 Series Inverted Microscope
Model-MOTIC AE31
S/N-10900001081
This microscope was removed from a university where it was surplus to requirement.
It powers up and is in good cosmetic condition.
All mechanical elements are in good working order.
Includes the following:
Objectives.
MOTIC 4X/0.10 WD 23.5
MOTIC PH10x/0.25 WD 7.5
MOTIC LWD PH20x/0.40 WD 7.0
MOTIC LWD PH40x/0.60 WD 2.8
Eyepieces.
2 x WFPL10X/22
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 2,000.00 (ex. VAT) 1 in stock
Carl Zeiss Axioskop Fluorescence Microscope w/ 6 x Objective ACHROSTIGMAT Lab
ITEM-31763
This Carl Zeiss Axioskop El Einsatz 45 14 87 Fluorescence Microscope was removed from a university lab where it was surplus to requirements.
The system has been professionally serviced. It is in full working order and good cosmetic condition.
Also included are the following:
6-position nosepiece, fitted with 5 objectives:
1 x Zeiss Ph3 Plan-NEOFLAUR 100x/1.30 oil ∞/0.17
1 x Zeiss Ph3 ACHROSTIGMAT 100x/1.30 oil ∞/0.17
1 x Zeiss Ph1 CP-ACHROSTIGMAT 10x/0.25 oil ∞/-
1 x Zeiss ACHROPLAN 4x/0.10 oil ∞/-
1 x Zeiss Ph2 ACHROSTIGMAT 40x/0.65 oil ∞/0.17
2 x Eyepieces Pl 10 x 20
1 x Condenser 0.9 HD Ph with swing-in front lens standard turret
1 x Mechanical Stage 75 x 30 cm
1 x Specimen Holder
1 x Carl Zeiss HBO 50
1 x Carl Zeiss 39 26 42-9901 70 Fluorescence Lamp PSU
£ 2,000.00 (ex. VAT) 1 in stock
Zeiss Axiovert S100 Microscope with 3 x Objectives Lab
ITEM-44926
Zeiss Axiovert S100 Microscope
This system was removed from a university lab where it was surplus to requirements.
The unit powers on and is in fair cosmetic condition. However, there is a cracked hole at the top front of the microscope.
Included:
- Blue filter
- Yellow/green filter
Objectives:
- Zeiss Achrostigmat 10x/0.25 (Yellow Band)
- Part No.: 44 01 31
- LD Achrostigmat 32x/0.40 PH1 (Green Band)
- Achrostigmat 5x/0.12 (Red Band)
Eyepiece:
- 2 x Carl Zeiss 44 42 32 E-Pl 10x/20
£ 1,900.00 (ex. VAT) 1 in stock
Motic AE21 Series Trinocular Inverted Microscope with 4x Objectives
ITEM-31762
Motic AE21 Series Trinocular Inverted Microscope with 4x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in very good, used cosmetic condition.
The microscope has been tested with one of our slides and is working well and is clear.
On the microscope are the following modules;
1x N.A. 0.30 condenser (WD 72mm) with halogen illumination 6v/30w.
1x Centerable PH slider supplied with phase ring PH 1
2 x Eyepieces - W10x/20
4 x Objectives:
1x Motic E Plan LWD PH 40x/0.60 ∞/1.1 WD 2.1
1x Motic E Plan LWD PH 20x/0.40 ∞/1.1 WD 5.5
1x Motic E Plan PH 10x/0.25 ∞/1.1 WD 6.3
1x Motic E Plan 4x/0.10 ∞/1.1 WD 14.2
£ 1,825.00 (ex. VAT) 1 in stock
Carl Zeiss Axioskop El Einsatz Fluorescence Microscope w/ 5 Objectives
ITEM-39731
Carl Zeiss Axioskop El Einsatz Fluorescence Microscope w/ 5 Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. It is in good cosmetic condition with minor marks.
It is made up of the following modules;
Carl Zeiss Axioskop El Einsatz Fluorescence Microscope
Model: Axioskop
Serial# : 23 7412
Carl Zeiss Microscope Power Supply VHW 50f-2b
Model: VHW 50f-2b
Serial#: 39 26 42
Lamp hours: 254.24
Carl Zeiss NAG 2, 12V 100W Stab Power Supply
Model: NAG 2 12V 100W
Serial#: 39 25 85
Carl Zeiss HBO 50 Lamp housing
Model: HBO 50
Serial#: 44 72 20
Carl Zeiss 12V 100W Halogen HAL Lamphouse
Model: 12V 100W Halogen HAL
Serial#: 44 72 18
Pl 10x/20 Eyepiece x 2
Serial#: 44 40 32
The following Objectives:
Zeiss Plan-NEOFLUAR
2,5x/0,075 ∞/-
Serial#: 44 03 10
Zeiss ACHROPLAN
40x/0,65 ∞/0,17
Serial#: 44 00 50
Olympus SPlan20PL
0,46 160/0,17
Serial#: 80 63 58
Zeiss ACHROPLAN
10x/0,25 Ph1 ∞/-
Serial#: 44 00 31
Zeiss ACHROSTIGMAT
5x/0,12 ∞/-
Serial#: 44 01 20
£ 1,800.00 (ex. VAT) 1 in stock
Leica DMIL Inverted Microscope Type 090-135.001 with 4 x Objectives
ITEM-30457
Leica DMIL Inverted Microscope Type 090-135.001 with 4 x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks.
Included are;
2 x Eyepieces:
Leica 10X/18 (527000)
Leica 10X/18 M (527001)
4 x Objectives
Leica ∞/1.1 HI PLAN I 40x/0.50 PH 2 (506273)
Leica ∞/0-2 HI PLAN I 20x/0.30 PH 1 (506272)
Leica ∞/-/ HI PLAN I 10x/0.22 PH 1 (506271)
Leica ∞/- HI PLAN 4x/0.10 (506226)
Stage - 11521248
BZ: 00
£ 1,800.00 (ex. VAT) 1 in stock
Leica Leitz DMRB Type 301-371.010 Trinocular Fluorescence Microscope Lab
ITEM-31571
Leica Leitz DMRB Trinocular Fluorescence Microscope Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and working order; however, one noticeable flaw is the missing paint on the top of the unit. This does not affect its functionality.
This microscope was tested with an in-house objective. (not included in sale)
Features the following:
1 x Leica Leitz DMRB Trinocular Fluorescence Microscope body.
Type 301-371.010.
Fitted with the following filter cubes:
- I3 513808 - For Blue Excitation.
- B/G/R 513836 - For DAPF/FITC/TEXAS RED Excitation.
- TX 513802 - For FITC Excitation.
- A 513804 - For UV Excitation.
1 x Leica 12volt 100watt Halogen lamp.
Type 307-155.001.
1 x Leica 501049 Top swing condenser fitted with a Leica 501000 0.90 S1 Lens.
1 x Leica mechanical stage with specimen holder.
2 x Leica L Plan 10x 25 eyepieces.
1 x QImaging Firewire Camera.
01-RET-2000R-F-CLR-12-C
Cooled Colour 12 Bit.
£ 1,780.00 (ex. VAT) 1 in stock
Motic AE21 Series Trinocular Inverted Microscope with 3x Objectives
ITEM-35890
Motic AE21 Series Trinocular Inverted Microscope with 3x Objectives
This was removed from a working lab where it was surplus to requirements.
The unit has been tested and is in good working order.
It is in very good cosmetic condition with minor marks
It is fitted with the following;
1x N.A. 0.30 condenser (WD 72mm) with halogen illumination 6v/30w.
1x Centerable PH slider supplied with phase ring PH 1
2 x Eyepieces - W10x/20
3 x Objectives:
1x Motic E Plan LWD PH 20x/0.40 ∞/1.1 WD 5.5
1x Motic E Plan PH 10x/0.25 ∞/1.1 WD 6.3
1x Motic E Plan 4x/0.10 ∞/1.1 WD 14.2
£ 1,750.00 (ex. VAT) 1 in stock
Leica DMIL Inverted Microscope Type 090-135.001 with 2 x Objectives Lab
ITEM-39243
Leica DMIL Inverted Microscope Type 090-135.001
This was removed from a university lab where it was surplus to requirements.
The unit powers on and is in working order. The focus knob is quite stiff but the fine adjustment works as intended.
It is in good cosmetic condition with minor marks.
Includes:
-Leica ∞/-/ C PLAN L 10x/0.22 PH 1 (506078)
-Leica ∞/0-2 C PLAN L 20x/0.30 PH 1 (506152)
2 x Eyepieces:
-Leica 10X/18 (527000)
-Leica 10X/18 M (527001)
£ 1,750.00 (ex. VAT) 1 in stock
Carl Zeiss Axiovert S100 TV Inverted Microscope Lab
ITEM-30361
Carl Zeiss Axiovert S 100 TV Inverted Microscope
The unit powers up but has not been tested as we do not have the objectives. It has received a full clean of all optical components and the realignment of the light path was completed. All mechanical parts were fully lubricated and reassembled.
Missing focus spindle (confocal removed.
It is in good cosmetic condition with minor marks.
£ 1,715.00 (ex. VAT) 1 in stock
Motic AE21 Series Trinocular Inverted Microscope with 2x Objectives
ITEM-35897
Motic AE21 Series Trinocular Inverted Microscope with 2x Objectives
This was removed from a working lab where it was surplus to requirements.
The unit powers up and is in good working order. The LED lamp brightness indicator does not work, but the brightness is still adjustable.
It is in good cosmetic condition with minor marks.
1x N.A. 0.30 condenser (WD 72mm) with halogen illumination 6v/30w.
1x Centerable PH slider supplied with phase ring PH 1
2 x Eyepieces - W10x/20
2 x Objectives:
1x Motic E Plan PH 10x/0.25 ∞/1.1 WD 6.3
1x Motic E Plan 4x/0.10 ∞/1.1 WD 14.2
Includes:
-Dust cover
-Box of eyepiece covers
-Instruction manual
£ 1,690.00 (ex. VAT) 1 in stock
Olympus CK40-F200 Inverted Microscope with 2 x Objectives Lab
ITEM-29926
This Olympus CK40-F200 Inverted Microscope was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks from use.
2 objectives
A 10 RP - 0.25 160/0.17
SPlan4RP 0.13 160/-
£ 1,630.00 (ex. VAT) 1 in stock
Motic AE21 Series Inverted Trinocular Microscope with 3x Objectives Lab
ITEM-35893
Motic AE21 Series Inverted Trinocular Microscope with 3x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks.
It is supplied with;
1x N.A. 0.30 condenser (WD 72mm) with halogen illumination 6v/30w.
1x Centerable PH slider supplied with phase ring PH 1
2 x Eyepieces - W10x/20
3 x Objectives:
1x Motic E Plan LWD PH 20x/0.40 ∞/1.1 WD 5.5
1x Motic E Plan PH 10x/0.25 ∞/1.1 WD 6.3
1x Motic E Plan 4x/0.10 ∞/1.1 WD 14.2
£ 1,615.00 (ex. VAT) 1 in stock
Motic AE21 Series Trinocular Inverted Microscope w/ 3x Objectives Lab
ITEM-35895
Motic AE21 Series Trinocular Inverted Microscope w/ 3x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with marks from use.
It is fitted with the following;
1x N.A. 0.30 condenser (WD 72mm) with halogen illumination 6v/30w.
1x Centerable PH slider supplied with phase ring PH 1
2 x Eyepieces - W10x/20
3 x Objectives:
1x Motic E Plan LWD PH 20x/0.40 ∞/1.1 WD 5.5
1x Motic E Plan PH 10x/0.25 ∞/1.1 WD 6.3
1x Motic E Plan 4x/0.10 ∞/1.1 WD 14.2
£ 1,600.00 (ex. VAT) 1 in stock
Motic AE21 Series Trinocular Microscope w/ 3 x Objectives Motic EPlan PH LWD Lab
ITEM-42047
Motic AE21 Series Trinocular Inverted Microscope with 3x Objectives
This microscope was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition, and full working order.
It has been tested with a goldfish scale and potato starch.
Objectives included:
- Motic E Plan 4X/0.10, ∞/1.1 WD 14.2
- Motic E Plan PH 10X/0.25, ∞/1.1 WD 6.3
- Motic E Plan LWD PH 20X/0.40, ∞/1.1 WD 5.5
£ 1,550.00 (ex. VAT) 1 in stock
Zeiss Axioskop Microscope w/ 3 x Objectives NEOFL 100x, 40x, 20x Lab
ITEM-41253
This Zeiss Axioskop Fluorescence Microscope System was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition but has some marks from use.
Does not include PSU for the mercury lamp, but it has been tested.
Included with it are;
2 x Eyepieces
Zeiss Pl 10x/20 (44 40 32)
3 x objectives
Zeiss plan-NEOFLUAR 100x/1,30 oil (44 04 81) PH3
Zeiss plan-NEOFLUAR 40x/0.75 oil (44 03 51) PH2
Zeiss plan-NEOFLUAR 20x/0.50 oil (44 03 41) Ph2
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,500.00 (ex. VAT) 1 in stock
Zeiss Axiovert 200M Fluorescence Microscope Lab Spares/Repairs
ITEM-36336
Zeiss Axiovert 200M Fluorescence Microscope
This was removed from a university lab where it was surplus to requirements.
The unit powered up but failed a service for the following reasons.
• Microscope in poor condition – broken (motorisation fault).
• Motorised base mirror will not move.
It is sold for spares/repairs.
£ 1,500.00 (ex. VAT) 1 in stock
Leica DMIL Inverted Microscope Type 090-135.001
ITEM-41191
Leica DMIL Inverted Microscope Type 090-135.001
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with marks from use.
No objectives included.
The microscope features:
2 x Leica 10X/18 Eyepiece
£ 1,350.00 (ex. VAT) 1 in stock
Zeiss Axiovert 25 Inverted Fluorescence Phase Contrast Microscope Lab
ITEM-40044
This Zeiss Axiovert 25 Inverted Fluorescence Phase Contrast Microscope was removed from a university lab where it was surplus to requirements.
The unit powers up and all the objectives appear to focus well. It is in good cosmetic condition with only minor marks from use.
There are 2 x Objectives included, and they are as follows;
Zeiss LD Achrostigmat 32X/0.40 ∞/0.5-1.5 Ph1
Zeiss CP-ACHROMAT 10x/0,25 ∞/- PH1
Eyepieces:
2 x E-Pl 10x/20
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,250.00 (ex. VAT) 1 in stock
Arcturus PixCell II Laser Capture Microdissection Microscope System Lab Faulty
ITEM-35289
Arcturus PixCell II Laser Capture Microdissection Microscope System Lab
This system was removed from a university where it was surplus to requirement.
All units are in good cosmetic condition and powered up, although due to the faults listed below this system is listed as Spares/Repair.
Faults:
- The PCi graphics card is faulty.
- Camera not included to operate as a complete system.
- The microscope does not include any eyepieces or objectives.
- The control unit cable sleeving is damaged.
The system comprises the following:
Arcturus PixCell II Microscope
Arcturus PixCell II Control unit
Computer - Dell OptiPlex GX1
- Software installed: Arc200 1.0.2
Monitor - NEC MultiSyncLCD1550V
£ 1,200.00 (ex. VAT) 1 in stock
Leitz Aristoplan Microscope, w/ Sony Power HAD, WILD Leitz MPS 52 Camera Lab
ITEM-41262
Leitz Aristoplan Microscope, w/ Sony Power HAD, WILD Leitz MPS 52 Camera Lab
This was removed from a university lab where it was surplus to requirements
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks.
Both cameras have not been tested as the required connecting cables are not supplied.
Optic Lenses:
-Periplan GW 10x/26 M Leitz Wetzlar
Both lenses are intact and clear with no cracks or chips in the glass
Magnifications:
-Leitz Wetzlar PL 2.5/0.08 160/-
-Leitz Wetzlar PL FLUOTAR 10/0.30 160/- (519872)
Sony Power HAD
3CCD Color Video Camera
Model-DXC-950P
S/N-406749
Wild Leitz Wild MPS 52
£ 1,115.00 (ex. VAT) 1 in stock
Leica Diavert Inverted Microscope w/ 4 x Objectives & 465 Power Supply Lab
ITEM-30390
Leica Diavert Inverted Microscope w/ 4 x Objectives & 465 Power Supply
This was removed from a university lab where it was surplus to requirements.
The unit is in reasonably good cosmetic condition. There are some light tape marks from general use, as well as some patina from age.
It is in good working order.
Included are;
1 x Leitz Phaco A 0.25 L62 Lamp
2x Eyepieces:
PERIPLAN GF 12.5x /20 M lietz Wetzlar Germany
4x Leitz Wetzlar Objectives:
1x 170/- 4/0.12
1x 170/- L32/0.4 Phaco 1
1x 170/- L20/0.32 Phaco 1
1x 170/- 10/0.25 Phaco
Power Supply:
Model. 465
£ 1,100.00 (ex. VAT) 1 in stock
Leitz Diavert Inverted Microscope w/ 3 x Objectives Lab
ITEM-36652
Leitz Diavert Inverted Microscope w/ 3 x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks from use.
Included are;
2x Eyepieces:
PERIPLAN 10 x Leitz Wetzlar Germany
Objectives:
Phaco 1 L32 /0,40 170/-
Phaco 1 10/0.25 160/-
Phaco 1 10/0.25 160/-
£ 1,100.00 (ex. VAT) 1 in stock
Leitz Diaplan 020-437.035 Microscope with Multi-Head Bridge w/4 x Objectives Lab
ITEM-31573
Leitz Diaplan Microscope with Multi-Head Bridge Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and working order.
This microscope features the following:
1 x Leica Diaplan Microscope Body.
1 x Leitz 513578 Multi-Head Bridge Fitted With:
1 x Leitz Trinocular Head.
2 x Leitz 519817 Periplan GF 10x/20M Eyepieces.
1 x Leitz 512740/20 Ergonomic Tilting Binocular Head Fitted With:
2 x Leitz Periplan 10x/18M Eyepieces.
1 x Leitz 513703 Polarized Light Slider.
1 x Leitz Mechanical Stage and Slide Holder.
1 x Leitz 513594 Universal Condenser With ACHR 0.90 S1.1
1 x Leitz 514686 12v 100watt Halogen Lamp.
The Microscope is fitted with 4 x Objectives:
1 x 79696
Leitz
170/0.17
PL Apo Oel
100/1.32
1 x 519737
Leitz
160/0.17
NPL FLUOTAR
40/0.70
1 x 519872
Leitz
160/-
PL FLUOTAR
10/0.30
1 x 519759
Leitz
160/-
EF 4/0.12
£ 1,035.00 (ex. VAT) 1 in stock
Carl Zeiss Axioskop EL Einsatz Microscope w/ 3 Objectives ACHROSTIGMAT Epiplan
ITEM-35285
Carl Zeiss Axioskop EL Einsatz Microscope
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with marks from use.
Eyepieces:
2 x 44 40 32
Objectives:
Plan NEOFLUAR 10x/0.30 ∞/0.17
ACHROSTIGMAT 40x/0.65 ∞/0.17, 44 01 50
Epiplan - NEOFLUAR 50x/0.80 HD 44 23 50 (Some of the text has come off this objective since there was a sticker on it. Removing it must have lifted the print.)
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Leitz Dialux 22 Fluorescence Microscope With Camera + Control Unit Lab Faulty
ITEM-39087
Leitz Dialux 22 Fluorescence Microscope with Camera + Control Unit
This system was removed from a university lab where it was surplus to requirements.
The unit does not power up. We have tested the continuity and found no issues, but we are unable to find the cause of the issue. The power supply for the lamp is a visual PAT test fail due to exposed wires and also does not power the lamp.
Due to the faults listed above, this system is listed as Spares/Repair.
The system comprises the following:
- Leitz Vario Orthomat Controller
- Leitz Power Supply for Lamp
- Leitz Vario Orthomat 2 Camera
- Leitz Wetzlar 100W Lamp (Type: 307-143.003)
5 x Objectives:
- NPL Fluotar 6.3/0.20
- NPL Fluotar 16/0.45
- NPL Fluotar 40/0.70
- Leitz EF 63/0.85
- Leitz PL 2.5/0.08
2 x Leitz Eyepieces Periplan GW 10x M
Model: Dialux 22
£ 1,000.00 (ex. VAT) 1 in stock
Zeiss Axioskop Microscope w/ J04Z0H Power Supply Lab
ITEM-44617
Zeiss Axioskop Microscope w/ J04Z0H Power Supply Lab
This item was removed from a university where it was surplus to requirement.
Both the microscope and power supply are in good cosmetic condition and full working order. The previous client has stated that this microscope was in full working order when it was last used.
It has been tested with an in-house objective, which is not included.
Includes the following:
1 x Zeiss Axioskop Microscope
-2 x Zeiss PL 10 X/ 20 Eyepiece
1 x Zeiss J04Z0H Power Supply
1 x Zeiss 12V 100W Halogen HAL Lamphouse
£ 1,000.00 (ex. VAT) 1 in stock
Ceti Versus 3400.0000 Inverted Microscope with 2 x Objectives Lab
ITEM-36432
Ceti Versus 3400.0000 Inverted Microscope
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
2 x Eyepieces - WF10x/20
2 x objective lenses: -
1x CETI PL L 25x/0.4 160/1.2
1x CETI Ph+25x/0.40 160/1.5
£ 1,000.00 (ex. VAT) 1 in stock
Carl Zeiss Axioskop El Einsatz Fluorescence Microscope Lab
ITEM-39789
Carl Zeiss Axioskop El Einsatz Fluorescence Microscope Lab
This microscope was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. It is in good cosmetic condition with minor marks. It was tested with an objective from another system.
The unit does not include any objectives or power supply.
Included are;
Pl 10x/20 Eyepiece x 2
Serial#: 44 40 32
£ 1,000.00 (ex. VAT) 1 in stock
Leitz Diavert Inverted Microscope Lab
ITEM-39057
Leitz Diavert Inverted Microscope
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in full working order but does not include Lamp Power Supply.
All mechanical elements are in good working condition with smooth, accurate movement.
Includes:
Leitz Wetzlar Gelbgrun (yellow-green) Microscope filter
Leica Leitz Phase Contrast Phaco 1 Microscope Filter in frame 39mm Dia
Leitz Phaco A 0.25 L62 Lamp:
2x Eyepieces:
PERIPLAN GF 10 x M Leitz Wetzlar Germany
Reasonably good clarity through both eyepieces.
Objectives:
Phaco 1 L32 /0,40 170/-
Phaco 1 10/0.25 160/-
Phaco L 20/0.32 170/-
Phaco 1 10/0.25 160/-
Items 1 to 50 of 86