All Products
Items 1751 to 1800 of 2630

£ 535.00 (ex. VAT) 1 in stock
B Medical Systems Plasma Storage Laboratory Freezer FR 410 G Lab
ITEM-32032
B Medical Systems Plasma Storage Laboratory Freezer FR 410 G
This was removed from a lab where it was surplus to requirements. We are told it was barely used by the client.
The unit powers up and has been tested with a digital thermometer (not included) to -41˚C.
It is in excellent cosmetic condition.
Internal dimensions - L50 W66 H87cm
2 Shelves 63 x 47cm
2 Drawers 59 x 46 x 6cm

NEW ITEM
NEW ITEM
£ 535.00 (ex. VAT) 1 in stock
17 Boxes of Mixed FisherBrand SureOne Pipet Tips Non filter + Aerosol Barrier
ITEM-35501
17 Boxes of Mixed FisherBrand SureOne Pipet Tips Non filter + Aerosol Barrier
Individually sealed and brand new.
10 packs of 96 tips per box amounting to 960 tips per box
Sizes are as follows:
100µl- 5 boxes (4800 tips)
300µl- 3 boxes (2880 tips)
10µl- 3 boxes (2880 tips)
200µl- 1 box (960 tips)
20µl- 2 boxes (1920 tips)
1000µl -3 boxes (2880 tips)
Also individually theres an additional:
10µl- 3 packs (288 tips)
20µl- 3 packs (288 tips)
200µl- 3 packs (288 tips)
100µl- 6 packs (576 tips)
300µl- 5 packs (480 tips)
Mixed expiry dates between 2026-2028

NEW ITEM
NEW ITEM
£ 535.00 (ex. VAT) 1 in stock
264 x Laboratory Trousers & Tunics - Pool Undersuits Lab
ITEM-36184
264 x Laboratory Trousers & Tunics - Pool Undersuits
All items are brand new in their original packaging.
Lab Trousers
Sizes are as follows:
4 - 55
6 - 77
8 - 88
10 - 22
11 - 22
Lab Tunic
Sizes are as follows:
100 - 55
108 - 77
116 - 88
124 - 22
140 - 22

£ 525.00 (ex. VAT) 1 in stock
Jouan EB170 Electron Sans Ther Laboratory Incubator Lab
ITEM-37023
Jouan EB170 Electron Sans Ther Laboratory Incubator
This was removed from a working lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in reasonably good cosmetic condition with marks from use.
2 Shelves - 47 x 47cm

£ 520.00 (ex. VAT) 1 in stock
Roche Reflotron Plus Dry Chemistry Analyser Lab
ITEM-24198
This Roche Reflotron Plus Dry Chemistry Analyser was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
It is in good cosmetic condition with some fairly minor marks from use.

£ 520.00 (ex. VAT) 1 in stock
2 x Rheodyne MX Series Port Selector Valves - MXX778-605 MXP9900-000 Lab
ITEM-31780
2 x Rheodyne MX Series Port Selector Valves
These were removed from a university lab where they were surplus to requirements.
Both units power up but we were unable to test them further at our facility.
They are in good cosmetic condition with minor marks from use.
Included are;
1x Rheodyne MXX778-605
S/N 1565
1x Rheodyne MXP9900-000
S/N 1947
1x AC Adaptor Power Supply
Model TR45A24 26A03
S/N 45240-0026102
Input: 100-240V~1.5A 50-60Hz
Output: 24V - 1.88A
1x AC Adaptor Power Supply
Model TR45A24 26A03
S/N 45240-0018963
Input: 100-240V~1.5A 50-60Hz
Output: 24V - 1.88A

£ 510.00 (ex. VAT) 1 in stock
Panasonic Model Type AW-HE60 CCTV Cameras
ITEM-37270
Panasonic AW-HE50 CCTV Cameras
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers on.
The previous client has stated it was in full working order prior to removal.
This item was tested with an in-house power supply cable. (not included.)

£ 510.00 (ex. VAT) 1 in stock
Triple Red Model Duo Organic 60 Ultra Pure Water Purification System Lab
ITEM-45398
Triple Red Duo Organic 60 Ultra Pure Water Purification System
This item was removed from a university where it was surplus to requirements.
The item is in good cosmetic condition and powers on. However, we were unable to perform further testing at our facilities.
Please note: The power supply is not included. Testing was carried out using a power supply from another unit.
Included Components:
- Avidity Carbon Pre-Filter
- P/N: TR-2057
- Install Date: 26/7/23
- Avidity Cartridge Pack
- P/N: TR-2050
- Install Date: 26/7/23
- Avidity Cartridge Polisher
- P/N: TR-2051
- Install Date: 26/7/23
Specifications:
- Model: Organic 60 Ultra Pure Water Purification System
- Serial No.: Not provided

£ 510.00 (ex. VAT) 1 in stock
Captair Erlab Model Ministore 822A - GB Cabinet Lab
ITEM-45263
Captair Erlab Model Ministore 822A - GB Cabinet Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, with fan operating.

£ 510.00 (ex. VAT) 1 in stock
Jobin Yvon Horiba CCD-3500V Detection Unit Lab
ITEM-35891
Jobin Yvon Horiba CCD-3500V Detection Unit
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in good cosmetic condition with minor marks.

£ 510.00 (ex. VAT) 1 in stock
Thermo Scientific Model Compact LidPark P00155 Lab
ITEM-37179
Thermo Scientific Compact LidPark P00155
This item was removed from a university where it was surplus to requirement.
It is in very good cosmetic condition and powers up, we are unable to test it further at our facility.
Model: LidPark P00155

£ 510.00 (ex. VAT) 1 in stock
Purite Select Purification System L300150 with Storage Tank Lab
ITEM-35809
Purite Select Purification System L300150 with Storage Tank
This was removed from a university lab where it was surplus to requirements.
The system powers up and pressurises but was not tested further.
It is in reasonable cosmetic condition with marks from use.
Both filters, Pretreat 8 and Puripac PP8 expired 15/02/23
100L Storage Tank

£ 505.00 (ex. VAT) 1 in stock
Hybaid Maxi 14 Hybridisation Oven Lab
ITEM-26176
Hybaid Maxi 14 Hybridisation Oven
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order, but may need calibrating to your equipment. It was tested with a digital thermometer (not included).
It is in good cosmetic condition with minor marks.
Internal Dimensions - D34 W34 H50cm

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 505.00 (ex. VAT) 1 in stock
Airwolf 3D NW3D HDX 3-D Printer Lab Spares/Repairs
ITEM-37979
Airwolf 3D NW3D HDX 3-D Printer Lab
This item was removed from a university where it was surplus to requirement.
The back panel is missing and, the wires are exposed, resulting in a visual PAT fail.
Due to the condition stated above, this item is listed as Spares/Repair.
Also included are the following:
- Power lead
- Data cable

£ 505.00 (ex. VAT) 1 in stock
MAT Medical BioMAT 2 Class 2 Recirculating Microbiological Safety Cabinet Lab
ITEM-31181
MAT Medical Air Technology BioMAT 2 Class 2 Microbiological Safety Cabinet
This was removed from a university lab where it was surplus to requirements.
The item powers on with airflow and UV light working, the white light doesn't work, but it may just be the bulb.
It is in good cosmetic condition with some marks from use.
Cabinet Dimensions - L120 W63 141cm
Frame Dimensions - L112 W60 H84cm
Internal workspace dimensions - D54 W106 H70cm

£ 500.00 (ex. VAT) 1 in stock
Packard 500TR Series Flow Scintillation Analyser D515F01 & Accessories Lab
ITEM-23476
This Packard 500TR Series Flow Scintillation Analyser was removed from a university lab where it was surplus to requirements.
The unit Powers on and is currently running 515TR BIOS version 3.11. We were unable to test it further.
It is in good cosmetic condition with only minor marks from use.
Included with it are;
1x 500TR reference manual
1x Floppy master disc FLO-ONE for windows Ver 3.65
1x External control cable
1x 24bit external control cable
1x FSA Pump retro fit kit
1x FSA 500TR Narrowbore pump Cal Instructions
2x Serial cables
1x Misc control cable
1x Flow cell LQTR 500 ul
1x Flow cell NBLQ 99 ul
1x Bag part of flow splitter 7700021
1x Bag of Homogenous option kit 7601621

£ 500.00 (ex. VAT) 1 in stock
Coherent Sapphire 488-200 CDRH Laser with CDRH HP Controller Lab
ITEM-20378
Coherent Sapphire 488-200 CDRH Laser with CDRH HP Controller
This was removed from a university lab where it was surplus to requirements.
Both units power up and the laser beam is working. It was tested with a cable from another unit. It is not included.
It is in good cosmetic condition with only minor marks from use.
Controller:-
Model - Sapphire CDRH HP
Part no. 1142958 REV AB
Laser head:-
Model - Sapphire 488-200 CDRH

£ 500.00 (ex. VAT) 1 in stock
Coherent Sapphire Laser 488-200 CDRH with CDRH HP Controller Lab
ITEM-20377
Coherent Sapphire Laser 488-200 CDRH with CDRH HP Controller
This was removed from a university lab where it was surplus to requirements.
Both units power on with the laser beam working. It was tested with a spare cable from another laser which is not included.
It is in good cosmetic condition with some minor marks from use.
Controller:-
Model - Sapphire CDRH HP
Part no. 1100969 Rev. AE
Laser head:-
Model - Sapphire 488-200 CDRH

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Zeiss LSM 510 Meta Confocal High Resolution Microscope - Spares / Repairs Lab
ITEM-19513
This Zeiss LSM 510 Meta Confocal High Resolution Microscope System was removed from a university lab as it developed a fault. The university reported:
"We have a confocal microscope (Zeiss LSM510 Meta) which we are hoping to sell. It powers up but doesn’t fully work, there must be a loose connection somewhere but I don’t have the time or space to work out where."
The units are all generally in reasonable used cosmetic condition. All parts do power up individually but we could not get the system to run either. We believe there should be a PC containing software that we do not have.
The system is sold for spares/repairs.
The system consists of:
1 x Zeiss Axiovert 200M Microscope (1312-732)
Fitted with:
1 x Zeiss 1269-455 Dual Illumination Source Motorised Mirror Switch.
1 x Zeiss 1058-431 Transmitted Light Channel LSM/Pascal.
2 x Zeiss 1016-758 W-PI 10x /23 eyepieces.
1 x HBO 100 Lamp 098.0042.000 (01/03163).
1 x HAL 100 Lamp 42 30 00.
With EBQ 100 Isolated Lamp PSU.
1 x Zeiss Laser Module 1294-260.
Two of the wheels are broken, so they have all been removed and it has been put on a pallet.
1 x Zeiss LSM510 Meta System.
Release 3.5 META 1305-593.
With Zeiss Remote 1260-157.
1 x Microscope isolation table.
Measures: 150cm L x 80cm W x 77cm H.
1 x Zeiss Temperature Control - 37 (0115.000).
1 x Zeiss AIM-SYSTEM Interface box 2436000101.

£ POA 1 in stock
Eppendorf 5402 Refrigerated Centrifuge w/ Eppendorf F-45-18-11 Rotor Lab
ITEM-46193
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Statebourne Bio 36 Nitrogen Dewar
ITEM-45505
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Lauda Alpha RA 8 Cooling Thermostatic Water Bath Lab Spares/Repairs
ITEM-38840
This item is new in stock. Please enquire for further details.

£ 500.00 (ex. VAT) 1 in stock
Zeiss Plan-NEOFLUAR 100x/1,30 Oil Objective
ITEM-44998
Zeiss Plan-NEOFLUAR 100x/1.30 Oil Objective
This item was removed from a university where it was surplus to requirements.
The objective is in good cosmetic condition, with no cracks or chips in the glass.
It has been tested and is fully functional.
Specifications:
- Magnification: 100x
- Aperture: 1.30
- Type: Oil Immersion

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Packard 9200 Hydrogen Generator B920000 Lab Spares/Repairs
ITEM-28161
Packard 9200 Hydrogen Generator
This was removed from a university lab where it was surplus to requirements.
We had the unit looked at by a service engineer. It is fully working but is leaking hydrogen.
It is in reasonably good cosmetic condition, but has some marks from use.
it is sold for spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
COURAGE + KHAZAKA Cutometer MPA580 Lab Spares/Repairs
ITEM-35208
COURAGE + KHAZAKA Cutometer MPA580
This was removed from a university lab where it was surplus to requirements.
The unit did not power up in testing. It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Gallenkamp Industrial BR185H C RO Environmental Chamber Spares/Repair Lab
ITEM-46438
Gallenkamp Industrial BR185H C RO Environmental Chamber Spares/Repair Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing it failed PAT on insulation after numerous attempts.
Therefore, further testing could not be complete and it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Scientific U570 -45 Ultra Low Temperature Freezer Spares/Repairs
ITEM-41126
New Brunswick Scientific U570 -45 Ultra Low Temperature Freezer
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition.
The item powers on but does not drop in temperature, therefore it is sold as Spares or Repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nikon BioStation IM With Parts Model-Cell-S1 Lab
ITEM-44884
Nikon BioStation IM With Parts
This system was removed from a university lab where it was surplus to requirements.
The unit is in poor cosmetic condition and cannot be powered on or tested as several parts are missing or not connected.
Therefore, this system is listed as Spares/Repair.

£ 500.00 (ex. VAT) 1 in stock
Luminex Bio-plex System w/ PC & Software - Luminex 100 / XYP Lab
ITEM-46148
Bio-plex System w/ PC & Software - Luminex 100 / XYP Lab
This system was removed from a university laboratory where it was surplus to requirements.
All included units are in good cosmetic condition and power on. We are unable to conduct further testing at our facility.
The previous owner states the system is still functional and includes a full PC setup along with the relevant software.
Includes:
- PC
- Monitor
- Instrument control USB
- Keyboard
- Mouse
- Manuals
- Luminex 100
- Luminex XYP
- 2 x Bottles
- Relevant cables
- Dongle

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Hitachi F-4500 Fluorescence Spectrophotometer System Spares/Repair Lab
ITEM-42393
Hitachi F-4500 Fluorescence Spectrophotometer System
This item was removed from a university laboratory where it was surplus to requirements.
The Hitachi F-4500 unit does not power on; however, it is in good condition with minimal wear. The previous owner said the PSU had failed.
Due to it not powering on it is listed as Spares/Repair
Includes:
- Vigen Genie P3 500 Computer
- Model: F-4500
- Serial No.: 1163-004
- Software: F-4500 FL_mnu - 2504060-05.

£ 500.00 (ex. VAT) 1 in stock
Union Carbide Liquified Gas Container Liquid Nitrogen Dewar Lab
ITEM-46190
Union Carbide Liquified Gas Container Dewar
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition, we are unable to test it further at our facility.

£ 500.00 (ex. VAT) 1 in stock
Peak Scientific Laboratory Table 3-1B Air and Sound Conditioned Pump Compartment
ITEM-42399
Peak Scientific Laboratory Table with Air and Sound Conditioned Pump Compartment
This item was removed from a university laboratory where it was surplus to requirements.
The table is in good cosmetic condition, powers on successfully, and all four fans are operational. We are unable to test it further at our facility.
This robust unit features a stainless steel tabletop with dimensions of 90 x 82 x 79 cm (L x W x H). The interior compartment measures 88 x 77 x 61 cm (L x W x H) and includes a sliding shelf sized 66 x 47 cm, designed to accommodate a vacuum pump or compressor.
Included Components:
- Four 10 cm Ebmpapst cooling fans (each consuming 2 watts)
- Removable bottle holder
- Sliding shelf for vacuum pump or compressor

£ 500.00 (ex. VAT) 1 in stock
Varian HS 602 Two Stage Rotory Vane Vacuum Pump Lab
ITEM-42171
Varian HS 602 Two Stage Rotary Vane Vacuum Pump
This item was removed from a university lab where it was surplus to requirements.
It is in very good cosmetic condition and powers on, we are unable to conduct further at our facility.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Don Whitely MK3 Anaerobic Bench Top Work Station Spares/Repair
ITEM-42468
Don Whitely MK3 Anaerobic Bench Top Work Station
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition but is not in working order, mainly due to a faulty gas inlet valve.
It powers on with functional temperature control and cooling fans. Key issues include non-working internal power sockets, flashing low CO2 and N2 warning lights, and a broken outer door lock seal knob, which compromises the chamber's sealing.
Due to the faults listed above, this system is listed as Spares/Repair.
Features:
- Uses hydrogen, nitrogen, and carbon dioxide or a standard anaerobic gas mixture.
- Digital temperature controller for constant temperature maintenance.
- Humidistat-controlled condensing plate for excess moisture removal.
- 30-litre interchange lock capable of holding 108 plates with vacuum flushing.
Includes:
- User Instruction Manual
Serial No.: 3170S

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer Piezorray Flexible Non-contact Microarraying System Spares/Repair
ITEM-45182
Perkin Elmer Piezorray Flexible Non-contact Microarraying System Spares/Repair
This system was removed from a university laboratory where it was surplus to requirements.
The Piezorray system powers up but encounters a software error indicating a problem with the device drivers or compatibility issues when connected to the PC.
The error prevents further use and testing of the system.
Therefore, it is listed as Spares/Repair.
The system comprises the following:
- 1 x Perkin Elmer Piezorray main unit
- 1 x Enclosure, seemingly custom for the Piezorray
- 1 x Perkin Elmer Precisely Unit
- 1 x Non-branded blue and white unit
- 1 x Cole Parmer Air Admiral Pump
- 1 x Elga PURELAB UHQ
- 1 x Cole Parmer Programmable Polystat Chiller
- 1 x StockerYale IMAGELITE MODEL 20 light source with Lightpipe
- 1 x Dell Optiplex 280 PC with Windows XP OS, Perkin Elmer Piezorray software, and National Instruments Measurement & Automation software, including keyboard, mouse, and monitor
Includes:
- 3 x Tecan 731070 Syringes (used)
- 2 x Spare temperature-controlled microplate holders
- 5 x ADKH501-4PK Test Record Autodrop Pipettes (new)
- Various spare tubing
Note: Tables are not included in the sale.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Shimadzu Total Organic Carbin Analyzer TOC-4200 Spares/Repair Lab
ITEM-46210
Shimadzu Total Organic Carbon Analyzer TOC-4200
This system was removed from a university laboratory where it was surplus to requirements.
It powers on and is in fair cosmetic condition externally, but the internal condition is poor. The cut cable is a IEC cable.
The following errors were noted during testing, as well as required consumables. Due to the errors listed, this system is listed as Spares/Repair.
Errors:
- 8PORT VALVE
- DEHUM FAN
- Blown capacitor on communication board.
Requires Consumables:
- CO2 ABS1
- CO2 ABS2
- PLUNGER TIP
- OIL SEAL.
Model: TOC-4200

£ 500.00 (ex. VAT) 1 in stock
LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab
ITEM-42425
LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab
This item was removed from a university lab where it surplus to requirement.
It is good cosmetic condition and good working order.

£ 500.00 (ex. VAT) 1 in stock
Denley Multipoint Inoculator A400 w/ Foot Pedal Lab
ITEM-42367
Denley Multipoint Inoculator A400 w/ Foot Pedal Lab
This item was removed from a university lab where it was surplus to requirement.
It in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.
The main unit successfully communicates with the included foot pedal.

£ 500.00 (ex. VAT) 1 in stock
Camspec Model M508 Spectrophotometer Lab
ITEM-46073
Camspec M508 Spectrophotometer
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition. We are unable to test it further at our facility.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Cecil CE 7200 Spectrometer Lab Spares/Repairs
ITEM-46062
Cecil CE 7200 Spectrometer Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, the display screen is damaged.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Cecil Type CE 7200 Spectrometer Lab Faulty Screen
ITEM-46061
Cecil Type CE 7200 Spectrometer Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, the display screen is damaged.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nikon Apophot Table Microscope with 4 x Objectives Lab Spares/Repairs
ITEM-35332
Nikon Apophot Table Microscope with 4 x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and the halogen bulb is working, but there appears to be no power going to the second lamp. Without the second lamp working we were unable to see a clear image during testing. We feel it may need a degree of refurbishment to get it working again so it is sold for spares or repairs.
It is in good cosmetic condition but has marks from age and use.
Item supplied with:
1 x Nikon Apophot Microscope.
1 x Nikon Transformer.
1 x Nikon 78567 DLL 40 0.65 0.17 Objective.
1 x Nikon 42502 10 Plan 0.25 Objective.
1 x Nikon 70693 DLL 40 0.65 0.17 Objective.
1 x Nikon 33525 DL 10 0.30 Objective.
2 x Nikon control panel.
2 x Nikon AFM.
2 x Nikon Eyepiece HKW 10x.
2 x Nikon Eyepiece HK 5x.
2 x Microtec WF 10x.
3 x Nikon M-35 S Camera.
Item powered on:
Nikon Transformer powered on.
Halogen bulb working.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Hera Freeze HFU Series Model HFU40240BV Lab Spares/repairs
ITEM-42306
Thermo Scientific Hera Freeze HFU Series Model HFU40240BV Lab Freezer
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, during testing it failed to cool and remained at ambient temperature when set to -86ºc. Further inspection iden
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Revco DXF Model DXF24040V Laboratory Freezer Lab Faulty
ITEM-42305
Thermo Scientific Revco DXF Model DXF24040V Laboratory Freezer
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on. During testing, it failed to reach the set temperature of -40˚C, only cooling down to 7˚C.
Therefore, it is listed as Spares/Repair.
Additionally, three inner door slide catches are missing.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Qiagen BIOROBOT 8000 Universal Platform Liquid Handling System Lab Spares/Repair
ITEM-46288
Qiagen BIOROBOT 8000 Universal Platform Liquid Handling System
This system was removed from a university laboratory where it was surplus to requirements.
It powers on but has not been tested further at our site.
The previous client has notified us that it is not in working order and that Qiagen no longer supports this instrument.
The system is in good cosmetic condition.
Includes:
- Cupboards/drawers integrated into the stand
- All bottles and solvent traps
- A pump
- 9 x 1100µl tip rack holders
- Multiple miscellaneous plate holders
- Tube holding racks
- Handles for moving the unit
- 4 x 50µl tip rack holders
- 1 pack of Elution Microtubes
- 1 BGR Bottle
- Lubricating oil
- Various QIAsoft 5.0 disks including operating system, protocol packages, and maintenance disks
- Data handbooks
- Manuals

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Qiagen BioRobot 8000 Liquid Handling System
ITEM-45167
Qiagen Bio Robot 8000
This item was removed from a university lab where it was surplus to requirements.
The system is in good cosmetic condition and powers on.
However, it displays errors during initialization (Z Motor 6: movement blocked, Code:8008 and Z Motor 8: movement blocked, Code:8008), preventing the robot from homing.
The lab reported that all components work except for one or more dilutor units in the syringe pump system, which Qiagen can no longer supply.
Therefore, this system is listed as Spares/Repair.
Included:
- Qiagen Bio Robot 8000
- Dell Control PC running Windows 7 with QIAsoft 4.1.4.5 software (discs included)
- Keyboard, monitor, and mouse
- Pump system
- Box containing various spare parts and consumables

£ 500.00 (ex. VAT) 1 in stock
FluidX FLX-20-1003 Scope Tube Barcode Reader Lab
ITEM-45416
FluidX FLX-20-1003 Scope USB Reader
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and in good working order.
Specifications:
- PN - FLX-20-1003
- SN - 1003-0519-017

£ 500.00 (ex. VAT) 1 in stock
Panasonic Model No. AW-HE60 CCTV Camera
ITEM-37269
Panasonic AW-HE50 CCTV Cameras
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers on.
The previous client has stated it was in full working order prior to removal.
This item was tested with an in-house power supply cable. (not included.)

£ 500.00 (ex. VAT) 1 in stock
Triple Red Duo Organic 60 Ultra Pure Water Purification System Lab
ITEM-45397
Triple Red Duo Organic 60 Ultra Pure Water Purification System
This item was removed from a university where it was surplus to requirements.
It is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.
Included Components:
- Avidity Carbon Pre-Filter
- P/N: TR-2057
- Install Date: 26/7/23
- Avidity Cartridge Pack
- P/N: TR-2050
- Install Date: 26/7/23
- Avidity Cartridge Polisher
- P/N: TR-2051
- Install Date: 26/7/23
Specifications:
- Model: Organic 60 Ultra Pure Water Purification System
- Serial No.: 0916961-01

£ 500.00 (ex. VAT) 1 in stock
Captair Erlab Ministore 822A - GB Cabinet Lab
ITEM-45262
Captair Erlab Ministore 822A - GB Cabinet Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, with fan operating.
Items 1751 to 1800 of 2630