Items 141 to 160 of 199

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 230.00 (ex. VAT) 1 in stock

Biochrom Type Libra Model S6 Spectrophotometer Lab

ITEM-41403

Biochrom Libra S6 Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The item failed the self-diagnostics test due to 'general system failure'



Includes 9V DVC Power Cable.

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 230.00 (ex. VAT) 1 in stock

Biochrom Model Type Libra S6 Spectrophotometer Lab

ITEM-41405

Biochrom Libra S6 Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The item failed the self-diagnostics test due to 'general system failure'



Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 225.00 (ex. VAT) 1 in stock

Sanyo CO2 Laboratory Incubator MCO-20AIC Lab

ITEM-29760

This was removed from a university lab where it was surplus to requirements.


The unit powers up and initially settled and stabilised at 37˚C


It was then set to its maximum of 50˚c. Item showed error code E15 after an hour.


E15= CO2 sensor box heater is abnormal. When the CO2 sensor box is open circuit, or SSR is short circuit "E15" & internal temperature are displayed alternately, & buzzer sounds intermittently.


Item supplied with 4 shelves.


Internal dimensions are: L58cm x W45cm x H66cm.



It is sold for spares/repairs.

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 225.00 (ex. VAT) 1 in stock

Biometra Duo-Therm-Oven OV 5 Hybridisation Oven Incubator Lab Spares/Repairs

ITEM-36105

Biometra OV 5 Duo-Therm Hybridisation Oven Incubator Lab Spares/Repairs


This was removed from a university lab where it was surplus to requirements.


Both units power up and incubate well up to a max of 50˚C, and the top rotary shaker is working. The control knob for the bottom shaker is broken and is non-functional.


It is in otherwise good cosmetic condition with minor marks.


It is sold for spares/repairs.


Included are; 4 x Biometra screw top bottles.

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 225.00 (ex. VAT) 1 in stock

Binder KB53 Refrigerated Incubator Mech 53L Lab Spares/Repairs

ITEM-36244

Binder KB53 Refrigerated Incubator Mech 53L


This was removed from a university lab where it was surplus to requirements.


The unit powers up but the fan is noisy and the unit does not cool down.


It is in reasonable cosmetic condition with marks from use.


It is sold for spares/repairs.



Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 225.00 (ex. VAT) 1 in stock

Dionex UltiMate 3000 LPG-3600 MB Micro Pump Lab Spares/Repairs

ITEM-36833

This Dionex UltiMate 3000 LPG-3600 Micro Pump was removed from a university lab where it was surplus to requirements.


When the right-hand pump is selected the pump cannot be purged due to excess pressure from the transfuser even though there is no pressure. It cannot run. When the left-hand pump is selected there is an error "excess drive current from camshaft.” “Drive current too large camshaft 270”. We can’t switch left pump off


The right-hand pump is at 71 bar at rest - and cannot purge.


It could be either a mechanical or electronic fault.


It is sold for spares/repairs.


Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 225.00 (ex. VAT) 1 in stock

Biochrom Model Type Libra S6 Spectrophotometer Lab

ITEM-41402

Biochrom Libra S6 Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The item failed the self-diagnostics test due to 'general system failure'



Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 220.00 (ex. VAT) 1 in stock

Pyrosequencing Pyrosequencer PSQ96 Lab Spares/Repairs

ITEM-31385

This Pyrosequencing Pyrosequencer PSQ96 was removed from a university lab where it was surplus to requirements.


The unit powers on but the lab confirmed it was faulty. We are not aware of the nature of the fault.


It is in good cosmetic condition with minor marks from use.


It is sold for spares/repairs.

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 220.00 (ex. VAT) 1 in stock

Biochrom Libra Model S6 Spectrophotometer Lab

ITEM-41401

Biochrom Libra S6 Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The item failed the self-diagnostics test due to 'general system failure'


Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 215.00 (ex. VAT) 1 in stock

Biochrom Libra S6 Model Spectrophotometer Lab

ITEM-41400

Biochrom Libra S6 Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The item failed 'wavelength calibration' on the self-diagnostics test.


Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 210.00 (ex. VAT) 1 in stock

Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge Lab Spares/Repairs

ITEM-36098

This Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge was removed from a university lab where it was surplus to requirements.


The unit does not power up and has had many parts removed from it, including the main board.


It is sold for spares/repairs.

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 210.00 (ex. VAT) 1 in stock

Biochrom Model Libra S6 Spectrophotometer Lab

ITEM-41399

Biochrom Libra S6 Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The item failed 'wavelength calibration' on the self-diagnostics test.



Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 205.00 (ex. VAT) 1 in stock

STOE PSD Supply Unit from XRD Diffraction System Lab Spares/Repairs

ITEM-17163

ITEM-17163

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 205.00 (ex. VAT) 1 in stock

Genlab LCI/12V/PDIG Laboratory Incubator Lab Spares/Repairs

ITEM-38917

Genlab LCI/12V/PDIG Laboratory Incubator


The unit powers up but will not allow a temperature to be set. It also will not heat up.


It is sold for spares/repairs.

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 205.00 (ex. VAT) 1 in stock

Biochrom Libra Type S6 Spectrophotometer Lab

ITEM-41398

Biochrom Libra S6 Spectrophotometer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The item failed 'general system failure' on the self-diagnostics test.



Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 200.00 (ex. VAT) 1 in stock

GenLab Oven Model-MINI/100/SS/F/DIG Lab Spares/Repairs

ITEM-44644

GenLab Oven Model-MINI/100/SS/F/DIG Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on. However, the It did not heat up in testing.


Therefore, it is listed as Spares/Repair.


Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 200.00 (ex. VAT) 1 in stock

LEEC Drying Cabinet Model SS Lab Spares/Repairs

ITEM-44639

LEEC Drying Cabinet Model SS Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition internally and externally but does not power on, therefore, it is listed as Spares/Repair.


Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 200.00 (ex. VAT) 1 in stock

Bioquell Microflow Advanced Bio Safety Cabinet Class 2 ABS 1200

ITEM-07303

This Bioquell Microflow Advanced Bio Safety Cabinet Class 2 ABS 1200 was removed from a university lab where it was surplus to requirements.


The unit powers up with airflow in working order, but cannot use other functions due to Battery failure.


It is in reasonably good cosmetic condition, with some marks from use. Due to the Battery failure, this item is listed as Spares/Repairs.


Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 200.00 (ex. VAT) 1 in stock

Ikonisys Ikoniscope Model 2000 Robotic Microscope System Lab Spares/Repairs

ITEM-14387

Ikonisys Ikoniscope Model 2000 Robotic Microscope System.


This item was removed from a lab where it was surplus to requirements.


We were unable to test it. It will not power up. We think there may be a fault with the APC power bank. The power supply was also blown when mistakenly connected to 240v instead of 110v. We did get it powered up with a PSU from another unit (not included). The bios indicates a memory issue, it is possible that the memory was damaged when the power supply perished.


The unit is in very good cosmetic condition but has some marks from use.


Included in total is;

Ikonisys contains:

1 x Olympus U-CMAD3

1 x Olympus U-TLU 7e14411.

1 x 4XEM Network Camera WLPTG.

1 X Redlake MegaPlus 2 ES 2020.

2 x Symbol Miniscan LS-1220-I300A Lasers.

1 x Phytron ZSS 41.200.2,1 E-4Lp.

1 x LUDL Electronics 89-IK-15000 Filter Chnager.

1 x 8 Port StarView.

1 x Smart UPS 2200.

1 x Olympus BX-UCB Universal Controller Unit.

1 x LUDL Electronics MAC5000 PS System.

1 x LUDL Electronics 99A360-IK Shutter 30mm W/HSNG.

1 x Olympus U-LH100HG.


The system has no objectives included.


Accessories include:

1 x Partial Reel Of Ikonisys Barcodes.

1 x Multimedia Computer System (No branding?)

1 x Y-UM76A Logitech Keyboard.

1 x Damaged Microsoft 1058 Wireless Mouse (Has No Battery Connection and cover) With Receiver.

1 x AL1717 F LCD Monitor.

6 x Keys For Ikonisys Unit.

1 x Symbol LS2208-SR20007R-UR Barcode Scanner & Stand.

1 x Peninsula Pheonix 2 Barcode Scanner.

1 x PC Wire.

14 x Spare Slide Boxes.

Image of item

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ POA 1 in stock

Waters Micromass ZQ Mass Spectrometer Lab Spares/Repairs

ITEM-35023

This item is new in stock. Please enquire for further details.

Items 141 to 160 of 199