Welcome to UniGreenScheme, your trusted source for high-quality, second-hand laboratory equipment. We specialize in providing cost-effective solutions for labs, universities, and research facilities worldwide, and we are proud to offer an asset resale service specifically designed for universities and laboratories.


From lab water baths to centrifuges, we offer a wide range of tested, reliable equipment to meet all your scientific and industrial needs. Shop with confidence and discover sustainable, high-quality lab solutions today.

Items 2051 to 2100 of 2782

Image of COURAGE + KHAZAKA Cutometer MPA580 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

COURAGE + KHAZAKA Cutometer MPA580 Lab Spares/Repairs

ITEM-35208

COURAGE + KHAZAKA Cutometer MPA580


This was removed from a university lab where it was surplus to requirements.


The unit did not power up in testing. It is sold for spares/repairs.

Image of Packard 9200 Hydrogen Generator B920000 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Packard 9200 Hydrogen Generator B920000 Lab Spares/Repairs

ITEM-28161

Packard 9200 Hydrogen Generator


This was removed from a university lab where it was surplus to requirements.


We had the unit looked at by a service engineer. It is fully working but is leaking hydrogen.


It is in reasonably good cosmetic condition, but has some marks from use.


it is sold for spares/repairs

Image of Varian 4000 GC/MS Gas Chromatograph 3800/3380 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Varian 4000 GC/MS Gas Chromatograph 3800/3380 Spares/Repair Lab

ITEM-46774

Varian 4000 GC/MS Gas Chromatograph 3800/3380 Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirements.


The previous owner has stated that various internal parts were removed.. Additionally, it is a visual PAT fail due to the top panel being removed.


Therefore, it was not powered on, and is listed as Spares/Repair.

Image of Mixed Job Lot of Laboratory Equipment - ProCon, Molecular Devices, Stuart, Zeiss

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Mixed Job Lot of Laboratory Equipment - ProCon, Molecular Devices, Stuart, Zeiss

ITEM-46877

This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.


None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.


None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.


They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.


The units have not been tested at all.


ProCon Integration Switcher PC / Audio / Video / Control IT AV

Stuart SI20H Hybridisation Oven / Shaker Lab Heating Equipment

Luckham Rotatest Platform Shaker Model - R100 Lab

Planer Kryosave Compact K250/1.7 & Temperature Gauge Model K51-230-N-F-H Lab

Pharmacia Biotech XK 50 Column, Accessory Kit & N-Acetyl-D-Galactosamine 250mg

CE Instruments AS 800 Autosampler Model - AS 800 C.U. Lab

LABCONCO 7455100 Centrifugal Evaporator Rotor with 148 x 2ml Wells Lab

Intavis Bioanalytical Instruments BioLane HTI 16V In Situ Hybridization System

Vickers Instruments Microscope w/ 3 x Objectives 40/ 0.70 10/ 0.25

Janke & Kunkel IKA-Labortechnik TP18/10 Homogeniser & TR50 Controller Lab

Ophir Laser Power Monitor with Gentee Joulemeter ED-200 Lab

Molecular Devices Vmax Kinetic Microplate Reader Lab

Packard SpectraCount Absorbance Microplate Reader Model: AS10001

Coulter ZM Cell Counter, S.ST.II Sampling Stand & V.C.U. VWII Vacuum Container

Rank Brothers Model 10 Integrated Oxygen Measurement Unit Lab

Hettich Mikro 185 Microcentrifuge Centrifuge Lab

Hettich Mikro 185 Microcentrifuge with 13300rpm Rotor Lab

Integra Vacusafe (158 3xx) With 2 x Integra Vacuboy Pipettes

Thermo Scientific Direct Exposure Probe

Griffin And George LTD Vernier Microscope With Box of Optics

MJ Research PTC-225 Peltier Thermal Cycler

Sirah PCH-1000 Circulator for Laser

Stuart Block Heater SBH130D Lab

Kyowa Light Controller

Leitz Microscope Power Supply

Zeiss Axio Standard X-Cite Adaptor

Zeiss AxioCam MRm

Misc microscope attatchment

Image of Genomic Vision Fiber Vision Automated Scanner Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Genomic Vision Fiber Vision Automated Scanner Spares/Repair Lab

ITEM-46906

Genomic Vision Fiber Vision Automated Scanner Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition and powers on, however the previous owner has notified us that it is not in working order and Genomics are no longer available for support.


Therefore, it is listed as Spares/Repair.

Image of ProteinSimple FluorChem E Imaging System Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

ProteinSimple FluorChem E Imaging System Spares/Repair Lab

ITEM-46915

ProteinSimple FluorChem E Imaging System


This item was removed from a university laboratory where it was surplus to requirements.


It is in reasonably good cosmetic condition. It powers on with "ProteinSimple" background and functional touchscreen/mouse.


Additionally, it emits an unhealthy noise when powered and the UV transilluminator does not appear to activate,


Therefore, it is listed as Spares/Repair


The previous owner stated the following: UV gel scanner, "lights half of the gel" and may need attention.

Image of Malvern MSX Mastersizer Particle Size Analyser - DIF 2000 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Malvern MSX Mastersizer Particle Size Analyser - DIF 2000 Lab Spares/Repairs

ITEM-25084

This Malvern MSX Mastersizer Particle Size Analysis System was removed from a university lab where it was surplus to requirements. The lab reported it had not been used for a number of years, but was working when they last used it.


The unit will likely require significant refurbishment, and for that reason it is sold for spares/repairs.


Included are;


1 x Malvern Particle Size Analysis Unit

Model MSX

The unit powers on and is in good cosmetic condition.


1 x Malvern Small Volume Sample Presentation Unit.

DIF 2000

The unit powers on and is in good cosmetic condition. It's in working order.


Accessories:

1x Laser enable key (850)

1x Malvern chamber Rittal key

1x Case strap

2x Case keys


3x Lenses

1x 45mm

1x300mm

1x pinhole


All lenses appear to be in good cosmetic condition.


Lens caps:

3x 67mm

1x 58mm

1x 46mm


1x 30ml clear plastic bottle (empty)

6x Clear tubing (various lengths)

4x Allen keys (various sizes)

2x wooden focal cassettes


2x cotton buds

1x Glass cassette

1x Metal arm/leaver (32908-29)

1x T1A 250v quick blow fuse


Floppy discs

12x Microsoft software

6x Malvern software

1 x Fast internet Access Supra Install CD

1x Supra Express Manual


4x User Manuals:

The units are in good cosmetic condition. It is unclear if there is missing information from the manuals as some folders contain loose papers.

Image of Biotage SP1 Flash Chromatography System Lab

£ 500.00 (ex. VAT) 1 in stock

Biotage SP1 Flash Chromatography System Lab

ITEM-21097

This Biotage SP1 Flash Chromatography System was removed from a university lab where it was surplus to requirements.


The unit powers up but the monitor is faulty. We connected it to an external monitor and were able to power up the system and access the software. The battery for the motherboard with likely need replacing at some point.


The system is comprised of the following modules.


1 x Biotage SPXE 10810016;

1 x Ecom Fixed Wavelength UV Detector ;

1 x Biotage SP1 System & Monitor.



Image of Coherent Sapphire 488-200 CDRH Laser with CDRH HP Controller Lab

£ 500.00 (ex. VAT) 1 in stock

Coherent Sapphire 488-200 CDRH Laser with CDRH HP Controller Lab

ITEM-20378

Coherent Sapphire 488-200 CDRH Laser with CDRH HP Controller


This was removed from a university lab where it was surplus to requirements.


Both units power up and the laser beam is working. It was tested with a cable from another unit. It is not included.


It is in good cosmetic condition with only minor marks from use.


Controller:-

Model - Sapphire CDRH HP

Part no. 1142958 REV AB


Laser head:-

Model - Sapphire 488-200 CDRH





Image of Coherent Sapphire Laser 488-200 CDRH with CDRH HP Controller Lab

£ 500.00 (ex. VAT) 1 in stock

Coherent Sapphire Laser 488-200 CDRH with CDRH HP Controller Lab

ITEM-20377

Coherent Sapphire Laser 488-200 CDRH with CDRH HP Controller


This was removed from a university lab where it was surplus to requirements.


Both units power on with the laser beam working. It was tested with a spare cable from another laser which is not included.


It is in good cosmetic condition with some minor marks from use.


Controller:-

Model - Sapphire CDRH HP

Part no. 1100969 Rev. AE


Laser head:-

Model - Sapphire 488-200 CDRH





Image of LEEC Research CO2 Incubator Model GA2000 Lab

£ 500.00 (ex. VAT) 1 in stock

LEEC Research CO2 Incubator Model GA2000 Lab

ITEM-41593

LEEC Research CO2 Incubator Model-GA2000


This item was removed from a university where it was surplus to requirement.


The unit powers up and is in good working order (thermometer not included).


It is in reasonably good cosmetic condition.

Image of Sanyo MCO-20AIC CO2 Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Sanyo MCO-20AIC CO2 Incubator Lab Spares/Repairs

ITEM-40000

Sanyo MCO-20AIC CO2


This was removed from a university lab where it was surplus to requirements.


It is in good cosmetic condition and powers up, it has been tested with a digital thermometer (not included).


The current CO2 Pump failed during testing and will require a new one to be fitted.


Therefore, it is listed as Spares/Repair.

Image of Leitz Wetzlar Dialux 20 Microscope w/ 3 x Objectives Phaco, Plan, NPL Lab

£ 500.00 (ex. VAT) 1 in stock

Leitz Wetzlar Dialux 20 Microscope w/ 3 x Objectives Phaco, Plan, NPL Lab

ITEM-40988

Leitz Wetzlar Dialux 20 Microscope


This was removed from a university lab where it was surplus to requirements.


The unit is in good cosmetic condition, with all mechanical elements in working order.


Includes the following.


1x Leitz Lamp Power Supply



Objectives:


1x Leitz Wetzlar P 10/0.25 170/-


1x Leitz Wetzlar NPL FLUOTAR 40/0.70 160/0.19 PHACO 2


1x Leitz Wetzlar PLAN 100/1.25 oil 160/0.17



Image of 154 Packs of Thermo Scientific Matrix D.A.R.T.'S (Tips) 5518-11, 300ul, (20pcs)

NEW ITEM

NEW ITEM

£ 500.00 (ex. VAT) 1 in stock

154 Packs of Thermo Scientific Matrix D.A.R.T.'S (Tips) 5518-11, 300ul, (20pcs)

ITEM-09513

This pack of tips was removed from a lab store as surplus to requirements.


There are 20 packs of 96 tips contained within each pack. Each pack is sealed and unused.


Packaging20 x 96 tips
Compatibility96/300 Versette Pipetting Head
Volume (Metric)300μL
FilteredFiltered
SterilitySterile
Length (English)Standard
For Use With (Equipment)Thermo Scientific™ Matrix Hydra DT, Thermo Scientific™ PlateMate Plus, Thermo Scientific™ Versette
Product LineD.A.R.T.'S
Unit Size-

Image of Boxer Steam Sterilising Laboratory Autoclave 400/220L Lab Spares or Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Boxer Steam Sterilising Laboratory Autoclave 400/220L Lab Spares or Repairs

ITEM-18171

This Boxer Steam Sterilising Laboratory Autoclave 400/220L was removed from a university lab where it was surplus to requirements.


The unit has controller issue, the temperature display is faulty, the door mechanism is faulty and we were unable to reset it.


It is in reasonably good cosmetic condition but it has marks from previous use.


It is sold for spares/repairs.



Image of Gynkotek  P 580 A HPLC Pump & Dionex UVD 170S UV Detector System Lab

£ 500.00 (ex. VAT) 1 in stock

Gynkotek P 580 A HPLC Pump & Dionex UVD 170S UV Detector System Lab

ITEM-24431

Gynkotek  P 580 A HPLC Pump & Dionex UVD 170S UV Detector System


This was removed from a university lab where it was surplus to requirements. The system powers up but has not been tested further.


It is in reasonably good cosmetic condition with marks from use.


It comprises of;


1 x Gynkotek HPLC

Type - P 580A


1 x Dionex UVD 170S

PN - 6068.4000A


1 x Dell Optiplex G1 with Keyboard & Mouse

Model no. MMP

Chromeleon Client Version 4.20 Build 350


1 x Box including:-

Gynkotek HPLC Pump Series P580 Operating Instructions

Gynkotek HPLC UV/VIS Detector UVD 170S/340S Operating Instructions

Chromeleon Chromatography Data Systems Version 4.20 Software CD & Tutorial



Image of Varian ProStar 335 Diode Array Detector lab

£ 500.00 (ex. VAT) 1 in stock

Varian ProStar 335 Diode Array Detector lab

ITEM-24902

This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were unable to test it further at our facility.


It is in good cosmetic condition with some marks from use.

Image of Beckman Coulter Avanti J-E Centrifuge  Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Beckman Coulter Avanti J-E Centrifuge Lab Spares/Repairs

ITEM-29745

Beckman Coulter Avanti J-E Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up but has several faults. The unit requires a new board, flash card and cooling system.


It is in good cosmeti condition with minor marks.


It is sold for spares/repairs.

Image of CTC Analytics HTC PAL MXY 04-01A Autosampler w/ Citation High Performance NMR

£ 500.00 (ex. VAT) 1 in stock

CTC Analytics HTC PAL MXY 04-01A Autosampler w/ Citation High Performance NMR

ITEM-30322

This CTC Analytics HTC PAL MXY 04-01A Autosampler System was removed from a university lab where it was surplus to requirements.


The system powers up and is in good cosmetic condition. Any issues with the individual modules are listed below.


Included in the system are;


1x CTC Leap Technologies Autosampler

Model MXY 04-01A


1x CTC Injection Unit

Model No. MZ 01-00F


1x CTC Stack Cooler DW

Model MC 04-01 Rev. G

The drawer doors have come away (plastic screws snapped)


1x CTC Power Supply

Part No. MN 01-00


1x CTC Pelter Thermostat

Part No. MN 03-00


1x CTC Terminal

Model No. 01-00A


1x CTC Injection Valve Drive unit

Model No. MV 02-01A


1x CTC Arm Platform

Model No. MR 034-02B


1x Motor Assembly Syringe Pal

Model No. MM 01-01F


1x Active Reverse Rinse Unit

Ser No. SDS1208007


1x XP power supply

Model AED45US24


1x Syringe Holder:

Model No. MSU 014-00A


The unit is in good cosmetic condition.


1x Citation High Performance Sample Loader

The PC powers on and is in good cosmetic condition.


There is a Leap Technologies program on the Sample loader


Other Control Programs:

• Solvent Conditioner Control 2.16

•One Minute NMR 2.18.43

•Citation Control 2.4


1x Protasis Desgasser


1x Reloatable Power Tap

Model PDU20BHVIEC 10R


8x IEC ports


Accessories:


2x PAL System X Type Syringes:

Part No. 20452/01


• 100µl


Hamilton Gas tight glass Syringes

2x 5.0ml


1x 1000µl


1x 0.25µl


The units are in good cosmetic condition.


1x L-Mark glass Syringe:

F/N 0.72(G22s)b51

•50µl


The unit is in good cosmetic condition (with needle)



100ml Wheaton Glass bottles:


3x with lids

2x without lids


The units are in good cosmetic condition.


500ml Glass bottles

1x Simax (with lid)


1x Boro 3.3 (without lid)


The units are in good cosmetic condition.

Image of Fuji Wrapper V FW3400 Horizontal Form-Fill-Seal Machine No Screen Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Fuji Wrapper V FW3400 Horizontal Form-Fill-Seal Machine No Screen Spares/Repair

ITEM-31330

Fuji Wrapper V FW3400 Horizontal Form-Fill-Seal Machine


This system was removed from a laboratory where it was surplus to requirements.


It has not been tested due to several cables being cut or disconnected. Significant work will be required to restore it to operational condition.

Additionally, the system is missing a screen and is therefore listed as for spares or repair.


Details:


Fuji Wrapper V FW3400 Horizontal Form-Fill-Seal Machine

  • Work Order: 03W233
  • Serial Number: 103204
  • Product Code: PHA3967
  • Source Voltage: AC200V 50/60Hz

Asahi Kinzoku Model NR-80

  • Serial Number: 402N9080076

Image of BMG Lab Technologies Fluostar Optima Microplate Reader Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

BMG Lab Technologies Fluostar Optima Microplate Reader Lab Spares/Repairs

ITEM-31557

This BMG Lab Technologies Fluostar Galaxy Microplate Reader was removed from a university lab where it was surplus to requirements.


The unit powers up but would not connect to a PC (not included) when we tried to test it. Other units would connect to this same PC, so we are sure it is the unit itself at fault, and not the PC.


It is in otherwise good cosmetic condition with minor marks but is sold for spares/repairs.

Image of 44 x Sony XCD-X710CR Industrial Firewire Cameras and Firewire Cables

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

44 x Sony XCD-X710CR Industrial Firewire Cameras and Firewire Cables

ITEM-36556



44x Sony XCD-X710CR Industrial Firewire Cameras


43x HR F1.4/8 mm Lenses

1x 2/3" F1.4 f=6mm lens


100x 10 meter Firewire cables

S/N: UNIB CAB6T6-100



This job lot of items comes from a university lab, The items were no longer required.


None of these items have been tested at our site - it is likely that some will be spares / repairs, but we anticipate that a reasonable amount should operate well.


None of these items have been PAT or electrical safety tested. For this reason we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.


They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the unit. It is an excellent opportunity for anyone looking to benefit for individual equipment resale.


The units have not been tested at all.

Image of Micromass LCT TOF Mass Spectrometer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Micromass LCT TOF Mass Spectrometer Lab Spares/Repairs

ITEM-36946

This Micromass LCT TOF Mass Spectrometer was removed from a university lab where it was surplus to requirements.


The unit powers up and is in good cosmetic condition with minor marks.


The lab reported that it was for spares or repairs but the fault is unknown. When we collected it, all the panels were removed, but we have fixed them back on.


Edwards parts fitted:-

SP25K N 9 Bar (SN-0171836682)

FL20K Foreline Trap (PN-A13305000/SN-165003057)

EXDC80 (PN-D39640000)



It is sold for spares/repairs.



Image of Esco NordicSafe NC2 - 4L8 Class 2 Safety Cabinet - Damaged Base Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Esco NordicSafe NC2 - 4L8 Class 2 Safety Cabinet - Damaged Base Lab

ITEM-39859

Esco NordicSafe NC2 - 4L8 Class 2 Safety Cabinet


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in good cosmetic condition, but is listed as Spares/Repair due to damage to the base of the cabinet.


Model: NordicSafe NC2 - 4L8

Serial: NC2-4L8-2013-80689

Image of Molecular Dynamics Storm 860 Molecular Phosphor Imager Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Molecular Dynamics Storm 860 Molecular Phosphor Imager Spares/Repair Lab

ITEM-42477

Molecular Dynamics Storm 860 Molecular Phosphor Imager – Spares/Repair


This item was removed from a university laboratory where it was surplus to requirements.


The system powers on, with cooling fans and status lights operating. No further testing was possible due to the absence of a control PC and software.


The previous owner reported it as faulty, but no specific faults were disclosed.


Includes:

  • Imager unit only
  • 1 x data cable

Image of Zeiss Plan-NEOFLUAR 100x/1,30 Oil Objective

£ 500.00 (ex. VAT) 1 in stock

Zeiss Plan-NEOFLUAR 100x/1,30 Oil Objective

ITEM-44998

Zeiss Plan-NEOFLUAR 100x/1.30 Oil Objective


This item was removed from a university where it was surplus to requirements.


The objective is in good cosmetic condition, with no cracks or chips in the glass.


It has been tested and is fully functional.


Specifications:

  • Magnification: 100x
  • Aperture: 1.30
  • Type: Oil Immersion

Image of Perkin Elmer Series 200 LC AutoSampler Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Perkin Elmer Series 200 LC AutoSampler Lab Spares/Repairs

ITEM-20652

Perkin Elmer 200 Series AutoSampler


This was removed from a university lab where it was surplus to requirements.


The unit powers up but is showing a flush motor fail error.


It is sold for spares/repairs.

Image of Jenway 6100 Visible Range Spectrophotometer Lab

£ 500.00 (ex. VAT) 1 in stock

Jenway 6100 Visible Range Spectrophotometer Lab

ITEM-42369

Jenway 6100 Visible Range Spectrophotometer


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.

Image of Miele Professional G 7883 Lab Glassware Washer Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Miele Professional G 7883 Lab Glassware Washer Spares/Repairs

ITEM-35868

Miele Professional G 7883 Lab Glassware Washer


This item was removed from a university laboratory where it was surplus to requirements.


The unit did not power up during testing and has had the lock and door switch removed. It is sold for spares/repairs.


In good cosmetic condition with minor marks.


Image of Rodwell Ensign 125 Floor Standing Autoclave Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Rodwell Ensign 125 Floor Standing Autoclave Spares/Repair Lab

ITEM-42378

Rodwell Ensign 125 Floor Standing Autoclave


This item was removed from a university laboratory where it was surplus to requirements.


Service and condition notes are as follows:


  • Unit powered on and lid opened without issue.
  • Evidence of the low water probe shorting onto the outside element, causing the machine to heat with low or no water.
  • All three heating elements were tested and found to be open circuit.
  • Three elements and the low water probe will need to be replaced.
  • It is advised that the unit be delivered to a specialist workshop if repair is to be undertaken.

Due to the faults identified, this item is listed as Spares/Repair.


Includes:


  • 1 x USB memory stick
  • 1 x inner basket

Specifications:


  • Model: Ensign 125
  • Serial No.: 2405
  • Year: 2015

  • Chamber dimensions: 46 cm diameter, 72 cm deep

Image of Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab

ITEM-46209

Shimadzu Total Organic Carbon Analyzer TOC-4200


This system was removed from a university laboratory where it was surplus to requirements.


It powers on and is in fair cosmetic condition externally, but the internal condition is poor. The cut cable is an IEC cable.


The following errors were noted during testing, as well as required consumables. - Due to the errors listed, this system is listed as Spares/Repair.


Errors:

  • 8PORT VALVE
  • DEHUM FAN

Requires Consumables:

  • CO2 ABS1
  • CO2 ABS2
  • PLUNGER TIP
  • CATALYST

Model: TOC-4200

Image of Powertecnique Uninterruptable Three-Phase Power Supply & Battery Box Lab

£ 500.00 (ex. VAT) 1 in stock

Powertecnique Uninterruptable Three-Phase Power Supply & Battery Box Lab

ITEM-20369

This Powertecnique Uninterruptable Three-Phase Power Supply & Battery Box was removed from a university lab where it was surplus to requirements.


This was last serviced december 2019. We understand they were in use until at least 2021, but may have been offline for some time so it is possible the batteries perform poorly.


The UPS powers up but has not been tested further. We were unable to test the battery box.


They are in reasonably good cosmetic condition but have some marks from use.



Image of Wheaton 753684-D 9 Deck R2P Roller Incubator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Wheaton 753684-D 9 Deck R2P Roller Incubator Spares/Repair Lab

ITEM-46315

Wheaton 753684-D 9 Deck R2P Roller Incubator


This item was removed from a university laboratory where it was surplus to requirements.


It is in reasonably good cosmetic condition and powers on; however, during testing it took approximately 5 hours to reach 37°C, with a maximum recorded temperature of 57°C despite being set to 60°C.


Internally, it houses a Wheaton Modular Cell Production Roller Apparatus Model 3. The roller mechanism powers on, but the rollers moved very slowly during testing. The speed control dial is missing, and manually adjusting the underlying nut did not improve the speed.


Due to the above issues, this item is listed as Spares/Repair.

Image of Sutter Lambda LS Illuminator LB-LS/17 Lab

£ 500.00 (ex. VAT) 1 in stock

Sutter Lambda LS Illuminator LB-LS/17 Lab

ITEM-41429

Sutter Lambda LS Illuminator LB-LS/17


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, but the power switch is stuck in the on position.


We are unable to test it further at our facility.


Lamp Runtime: 05573.7 hours


Image of B.O.B Stevenson Type 355 BI/J Centrifugal Fume Extraction Fan

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

B.O.B Stevenson Type 355 BI/J Centrifugal Fume Extraction Fan

ITEM-41463

B.O.B Stevenson Type 355 BI/J Centrifugal Fume Extraction Fan


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition, we are unable to test it further at our facility.


The unit has no cabling and is sold for spares/repairs

Image of SG Ultra Clear TUF UV Ultrapure Water System With Permeate Tank Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

SG Ultra Clear TUF UV Ultrapure Water System With Permeate Tank Lab

ITEM-41441

SG Ultra Clear TUF UV Ultrapure Water System With Permeate Tank


This system was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


The lab confirmed it was not in working order but were unable to confirm the fault. It is sold for spares/repairs


Included with the system is the following:


  • Permeate Tank

  • Cartridge Polisher
  • P/N- TR-2051

  • DI Cartridge
  • P/N- TR-2050

  • Carbon Pre-Filter
  • P/N- TR-2057

  • Carbon Pre-Filter (expired)
  • P/N- TR-2057

  • DI Cartridge (expired)
  • P/N- TR-2050

  • User Manual

Image of Eppendorf Refrigerated Centrifuge 5804 R Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Eppendorf Refrigerated Centrifuge 5804 R Lab Spares/Repairs

ITEM-41484



Eppendorf Refrigerated Centrifuge 5804 R Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition but does not power on, therefore we are unable to test it further, and it is listed as Spares/Repair.


The control board is faulty, and is loose inside the chamber.


There is no rotor.

Image of Buchi Distillation Chiller B-741 Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Buchi Distillation Chiller B-741 Lab

ITEM-41489

Buchi Distillation Chiller B-741 Lab


This item was removed from a university where it was surplus to requirement.


It powers on but is in poor cosmetic condition, we are unable to test it further at our facility.


The unit is sold for spares/repairs as we believe it will need quite a bit of remedial action to get it working properly.


It is missing one of is feet.

Image of Job Lot of Mixed Benchtop Lab Equipment - Corning, Stuart, Fisherbrand, Mettler

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Job Lot of Mixed Benchtop Lab Equipment - Corning, Stuart, Fisherbrand, Mettler

ITEM-41521

This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.


None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.


None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.


They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.


The units have not been tested at all.


ITEM-37170 Brady BP-1344

ITEM-37171 Grant Water Bath

ITEM-37172 Electrothermal Heating Mantle

ITEM-37173 Boc Regulators

ITEM-41531 2 x Pneuchange units

ITEM-41532 Grant Water Bath

ITEM-41533 Cylinder change over unit

ITEM-41534 Grant Water Bath

ITEM-41535 Grant Bio PV-1

ITEM-41536 Corning PH Meter 240

ITEM-41537 Fisherbrand Hydrus 500

ITEM-41538 Optoma Projector

ITEM-41539 Stuart SB162

ITEM-41540 Stuart CB161

ITEM-41541 Mettler AJ50

ITEM-41542 Box of pipettes

ITEM-41543 UVP Transilluminator

ITEM-41544 Light box

ITEM-41545 Pump

ITEM-41546 Thermo Espresso Centrifuge

ITEM-41547 Sanyo Micro Centaur

ITEM-41548 Sauter Scales

ITEM-41549 2 x Micro centaurs

ITEM-26100 Grant Bio Mini Shaker PMS-1000i

ITEM-26104 Eppendorf 5415 D

ITEM-26106 WhirliMixer

ITEM-11686 AdvanSys ASB 3940UA Ultra SCSI Storage Controller IT Equipment

ITEM-26094 Freezer racking

ITEM-26103 Pharmacia Biotech Electrophoresis Power Supply

ITEM-30161 Harvard 6012 stimulator

ITEM-26027 CORIOscan Connect +

ITEM-26099 Freezer rack sample holders

ITEM-30113 Needles, mixed makes/types

ITEM-26102 APC Smart-UPS 100

ITEM-26101 Lucent Technologies RM200 Power Supply

ITEM-27923 Vickers Instruments Microscope

ITEM-27922 Vickers Instruments Microscope

ITEM-27921 Vickers Instruments Microscope

ITEM-26107 accujet Pro

ITEM-27919 Vickers Instruments Microscope

ITEM-27920 Vickers Instruments Microscope

ITEM-27918 Vickers Instruments Microscope

ITEM-27917 Vickers Instruments Microscope

ITEM-27915 Vickers Instruments Microscope

ITEM-27916 Vickers Instruments Microscope

ITEM-27914 Vickers Instruments MIO A Microscope

ITEM-27906 Vickers Instruments Microscope

ITEM-26108 Microcentrifuge

ITEM-26097 Bio Rad Trans-Blot SD Cell

ITEM-26096 Techne MCS-104S

Image of Geneflow Sensoquest LabCycler Gradient Laboratory Thermal Cycler Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Geneflow Sensoquest LabCycler Gradient Laboratory Thermal Cycler Lab Faulty

ITEM-41560


Geneflow Sensoquest LabCycler Gradient Laboratory Thermal Cycler Lab


This item was removed from a university where it was surplus to requirement.


The unit did not power up in testing. it is sold for spares/repairs

Image of NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs

ITEM-41633

NESLAB Coolflow CTF33 Refrigerated Recirculator Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, although we were unable to set the desired temperature due to a display fault.


Therefore, it is listed as Spares/Repair.

Image of Jouan Refrigerated Centrifuge  Model - CR412 with 4750RPM Rotor & Inserts Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Jouan Refrigerated Centrifuge Model - CR412 with 4750RPM Rotor & Inserts Lab

ITEM-41652

Jouan Refrigerated Centrifuge  Model - CR412 with 4750RPM Rotor & Inserts Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however, when powered on the display reads '0000' and no controls are operable, thus preventing any testing from being conducted.


Therefore, this item is sold as Spares/Repair.


Image of Laboratory Isolation Table - White Lab

£ 500.00 (ex. VAT) 1 in stock

Laboratory Isolation Table - White Lab

ITEM-41681

Isolation Table - White Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition, we are unable to test it further at our facility.

Image of Heraeus Instruments Labofuge 400R Function Line Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Heraeus Instruments Labofuge 400R Function Line Lab Spares/Repairs

ITEM-41702

Heraeus Instruments Labofuge 400R Function Line Lab


This item was removed from a university where it was surplus to requirement.


It is in fairly poor cosmetic condition and powers on, however, due to an issue with the cooling/heating element it did not reach any desired temperature when tested.


Therefore, it is listed as Spares/Repair.


Additionally, it was tested to its maximum speed of 4500RPM, which performed well with no issues.




Image of Miele Professional Dishwasher  GG05 Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Miele Professional Dishwasher GG05 Spares/Repairs

ITEM-24741

Miele Professional Dishwasher  GG05


This was removed from a university lab where it was surplus to requirements.


The unit powers up and has been tested.  The inlet pressure is sufficient, the filter has been checked, cleaned and the propeller adjusted but shows an error  404 message which indicates there is an inlet issue.


It is sold for spares/repairs as it needs a new inlet.

Image of Eppendorf Realplex 4 MasterCycler Epgradient S Real Time Cycler 96-Well Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Eppendorf Realplex 4 MasterCycler Epgradient S Real Time Cycler 96-Well Lab

ITEM-31867

Eppendorf Realplex 4 MasterCycler Epgradient S Real Time Cycler 96-Well


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however it does not include the required controller. We made several attempts to connect it to the software from another unit (not included), but it would not communicate Therefore, it is listed as Spares/Repair.


Includes an Eppendorf USB drive with pre-installed software and a digital user manual.

Image of Binder KB 240 Refrigerated Incubator Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Binder KB 240 Refrigerated Incubator Spares/Repair Lab

ITEM-42729

Binder KB 240 Refrigerated Incubator


This item was removed from a facility where it was surplus to requirement.


The unit powers on, and the screen is functional.


However, temperature settings could not be adjusted during testing, and the unit did not rise above ambient temperature when left running.


Therefore, it is listed as Spares/Repair.


Includes:

  • Four internal shelves

Image of Panasonic Model No. AW-HE60 CCTV Camera

£ 500.00 (ex. VAT) 1 in stock

Panasonic Model No. AW-HE60 CCTV Camera

ITEM-37269

Panasonic AW-HE50 CCTV Cameras


This item was removed from a university lab where it was surplus to requirements.


It is in good cosmetic condition and powers on.


The previous client has stated it was in full working order prior to removal.


This item was tested with an in-house power supply cable. (not included.)

Image of Spellman Power Supply RSBX30X3077 Lab

£ 500.00 (ex. VAT) 1 in stock

Spellman Power Supply RSBX30X3077 Lab

ITEM-34855

Spellman Power Supply RSBX30X3077

Model: RSBX30X3077


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition, but we are unable to test it at our facility.


Includes 9-pin FEMALE DIN Cable.


Image of Sanyo MCO-18AIC CO2 Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Sanyo MCO-18AIC CO2 Incubator Lab Spares/Repairs

ITEM-39999


Sanyo MCO-18AIC CO2 Incubator


This was removed from a university lab where it was surplus to requirements.


It is in good cosmetic condition and powers up, it has been tested with a digital thermometer (not included).


The current CO2 Pump failed during testing and will require a new one to be fitted.


Therefore, it is listed as Spares/Repair.


Features 3 Shelves.

Items 2051 to 2100 of 2782

Filters

Price (£)

to

Condition

Category filters