All Products
Items 2251 to 2300 of 3389
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Renishaw Raman Confocal System Parts Lab Spares/Repairs
ITEM-37159
Renishaw Raman Confocal System Parts Lab
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
Included are the following;
1x Renishaw Raman unit
1x Renishaw SYS100 Unit:
Model SYS100
1x Renishaw Laser unit:
Model FOP
1x Renishaw Laser unit:
Model FOP7-514
2x Spectra-Physics Laser Heads:
Model no. 160-C4210
1x Laser Head Power Cable:
1x Interlock Overide Cable B
2x Spectra-Physics Laser Power Supplies:
Model no. 263-C03 714792R-did not power on. - (with enable key).
Model no. 263-C04 - powers on. - (no enable Key).
2x Power Supply Cables
2x Spectra-Physics Remote
Model 361C
1x YC-05II Video Camera
Objectives:
1x RED- Unbranded 4/ 0.10 160/0.17
1x BLUE- Unbranded 40/ 0.65 160/0.17
1x GREEN- Olympus SLMPlan 20X /0.35 ∞ / 0
NEW ITEM
NEW ITEM
£ 500.00 (ex. VAT) 1 in stock
11 x Packs Various Thermo Scientific Nalgene Coex Polyethylene Film Tank Liners
ITEM-38725
These were removed from a working lab where they were surplus to requirements.
Included are;
Nalgene™ Coex Polyethylene Film Tank Liners x 2
Catalog number: 343050-0005
Description: Gamma Irradiated: 5 gal. (19L)
Material: Polyethylene
Capacity (English) 5 gal.
For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200
No. per Pack 10
Nalgene™ Coex Polyethylene Film Tank Liners x 5
Catalog number: 343050-0030
Description: Gamma Irradiated: 30 gal. (113L)
Material: Polyethylene
Capacity (English) 30 gal.
For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200
No. per Pack 10
Nalgene™ Coex Polyethylene Film Tank Liners x 3
Catalog number: 343050-0007
Description: Gamma Irradiated: 7.5 gal. (28L)
Material: Polyethylene
Capacity (English) 7.5 gal.
For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200
No. per Pack 10
Nalgene™ Coex Polyethylene Film Tank Liners x 1
Catalog number: 343050-0015
Description: Gamma Irradiated: 15 gal. (57L)
Material: Polyethylene
Capacity (English) 15 gal.
For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200
No. per Pack 8
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer 785A UV-VIS Detector Lab
ITEM-41330
Perkin Elmer 785A UV-VIS Detector Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, we are unable to test it further at our facility.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter Avanti J-25 Centrifuge Spares/Repair Lab
ITEM-41342
Beckman Coulter Avanti J-25 Centrifuge Lab
This was removed from a lab where it was surplus to requirements.
It failed to power on, it is therefore listed as Spares/Repair.
£ 500.00 (ex. VAT) 1 in stock
Sutter Lambda LS Illuminator LB-LS/17 Lab
ITEM-41429
Sutter Lambda LS Illuminator LB-LS/17
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, but the power switch is stuck in the on position.
We are unable to test it further at our facility.
Lamp Runtime: 05573.7 hours
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Leica SP5 Confocoal Laser w/ NEC Monitors For Parts Lab
ITEM-41643
Leica SP5 and HP Z620 Workstation System with NEC Monitors - For Parts or Repair
This system was removed from a university lab where it was surplus to requirements.
The setup primarily consists of components from a Leica SP5 system but is currently non-operational and intended for spares or repairs.
This collection of equipment is in need of significant repairs, especially the electrical connections, as noted from the site that "Electrics are bust."
Included Equipment;
- NEC MultiSync LCD 1990SXi Monitors (2 units): Dual monitors that are part of the system.
- HP Z620 Workstation PC Tower: Includes a keyboard and mouse but does not have HDDs. It retains PCi cards for the Leica system.
- Leica SP5 Unit: The operational condition is uncertain. It suffers from severe damage to the umbilical cable, with various wires cut, which affects its functionality.
- Leica Microsystems CMS TCS SP5 Control Table: Comes with a table, but similar to the SP5 unit, it has umbilical cables that have been severed.
- Leica Exhaust Unit: Forms part of the ventilation system for the Leica SP5.
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer LS50B Luminescence Spectrometer Lab
ITEM-38260
This Perkin Elmer LS50B Luminescence Spectrometer was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further at our facility.
It is in good cosmetic condition, with minor marks from use.
The sample plate is not included.
Further testing is not possible without the necessary PC and Software.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Hounsfield H20K-W Tensometer
ITEM-39881
Hounsfield H20K-W Tensometer w/ PSU & Various Parts
This item was removed from a university lab where it was surplus to requirements.
We are unable to test due to the power supply not being included, therefore this item is sold as Spares or Repairs.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Millipore Guava EasyCyte HT Flow Cytometer Lab Spares/Repairs
ITEM-40069
Millipore Guava EasyCyte HT Flow Cytometer
This was removed from a university lab where it was surplus to requirements.
The system is in good cosmetic condition and powers on, however during testing there were undiagnosed issues identified that prevented use.
Therefore, it is listed as Spares/Repair.
£ 500.00 (ex. VAT) 1 in stock
DakoCytomation Diode Lyt 200-S Laser Head w/ Controller & Fan/Cooler Lab
ITEM-41212
DakoCytomation Diode Lyt 200-S Laser Head w/ Controller & Fan/Cooler
This was removed from a working MoFlo system. It was surplus to requirements.
The unit powers up but has not been tested further due to safety restrictions around lasers at our site.
It is in good cosmetic condition with minor marks.
£ 500.00 (ex. VAT) 1 in stock
Vacuubrand Vakuum-Pump system BVC 81 VNC 1 Lab
ITEM-41234
Vacuubrand Vakuum-Pump system BVC 81
This was removed from a university lab where it was surplus to requirements.
The unit powers up and runs. The tube connecting the pump to the bottle has been snapped off, allowing all the air to escape before it converts into the bottle. This tubing will need to be replaced but is a consumable.
Unable to test further at our facility.
£ 500.00 (ex. VAT) 1 in stock
Biotage Jones Chromatography Flashmaster II System Lab
ITEM-20480
This Biotage Jones Chromatography Flashmaster II System was removed from a university lab where it was surplus to requirements.
The unit powers on and is in very good cosmetic condition. It has not been tested further at our facility.
There is some chipped paint along the top of the unit and scuffs and scratches from general use.
£ 500.00 (ex. VAT) 1 in stock
Advanced Analytical Fragment Analyzer Automated CE System Lab
ITEM-31907
Advanced Analytical Fragment Analyzer Automated CE System
This was removed from a university lab where it was surplus to requirements.
The unit powers up but was supplied without software so we have been unable to test it further.
It is in good cosmetic condition with minor marks from use.
£ 500.00 (ex. VAT) 1 in stock
Antec Scientific Alexys 100 LC-EC System Lab - AC 100, LC 110, AS 100, LC 100
ITEM-25232
This Antec Scientific Alexys 100 LC-EC System was removed from a university lab where it was surplus to requirements.
All the modules power up but have not been tested further at our facility. It is in good cosmetic condition with only minor marks from use.
The lab informed us that it was working fine before it was put away about 5 years ago.
There are a number of consumables included with it.
The system includes;
1x LC 100
Part No. 182.0035
1x AC 100
Part No. 183.0035
1x LC 110
Part No. 193.0035
1x AS 100
Part No. 181.0037
1x Decade II
Part No. 171.0035
1x OPR
Part No. 184.0035
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer Fluorescence 204 Spectrophotometer Analyser Laboratory Equipment
ITEM-06749
This was removed from a university lab where it was surplus to requirements
The unit powers up but has not been tested further.
It is in reasonably good cosmetic condition with minor marks.
£ 500.00 (ex. VAT) 1 in stock
Prior PL012 Binocular Microscope With 4 x Objectives Lab
ITEM-44462
Prior PL012 Binocular Microscope With 4 x Objectives
This item was removed from a university lab where it was surplus to requirements.
It powers on and is in reasonably good cosmetic condition.
Includes 4 x objectives:
- EA 100 Oil 1.25 160/0.17 (clear image could not be obtained)
- EA 4 0.10 160/-
- EA 10 0.25 160/-
- EA 40 0.65/0.17 (clear image could not be obtained)
2 x WF 10X/20 Eyepiece.
Model: PL012
S/N: 57403
£ 500.00 (ex. VAT) 1 in stock
Leica AODS 20200-8 Laser Modulator Lab
ITEM-44501
Leica AODS 20200-8 Laser Modulator Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Power supply not included.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MDF-U442 Medical Freezer Lab Spares/Repairs
ITEM-44667
Sanyo MDF-U442 Medical Freezer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, but it is not functional as it stays at ambient room temperature and triggers the alarm when the desired temperature is set.
Therefore, it is listed as Spares/Repair.
£ 500.00 (ex. VAT) 1 in stock
Bio-Rad UltraMark Microplate Imaging System
ITEM-45008
Bio-Rad UltraMark Microplate Imaging System
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in fair cosmetic condition.
No controller or additional equipment included to adjust the temperature.
Model: Ultramark.
£ 500.00 (ex. VAT) 1 in stock
Job Lot of 13 Vintage Microtome Knives With Sharpening strops and Whetstones
ITEM-42018
Job Lot of 13 Vintage Microtome Knives With Sharpening Strops and Whetstones
These items were removed from a university lab, where they were surplus to requirement.
The knife blades are all in very good condition, with sharp and undamaged cutting edges, appearing to have been well maintained, except for the hand knife, which has a poor cutting edge.
The wooden boxes are in excellent condition, except for two that are damaged.
The lot comprises:
- 3 x Shandon Nothung C wedge shape 20cm blades (circa 1967) in box
- 1 x Shandon Northung A concave 25cm blade (circa 1967) in box
- 1 x Unidentified C wedge 18cm blade in box
- 3 x MSE Ltd No. 9057.W wedge 9cm blades in box
- 2 x Cambridge Instruments rocking microtome knives (10cm blades) in box
- 1 x Unidentified wedge 8cm blade in leather case
- 1 x Hand knife with handle in poor condition in box
- 4 x Leather sharpening strops (30-35cm long), 2 in box
- 2 x 15cm whetstones
- 1 x Acrylic 15cm sharpener
- 1 x 25cm blade holder
- 3 x 20cm blade holders
- 1 x 17cm blade holder
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Protec Eco Max X-Ray Film Processor Lab Spares/Repairs
ITEM-42060
Protec Eco Max X-Ray Film Processor
This item was removed from a university laboratory where it was surplus to requirements.
The unit powers on and is in fair condition with some wear. There are some spots of rust, and the baseplate is missing. Therefore, resulting in a visual PAT fail.
It is listed as Spares/Repair.
Specifications:
- Model: Eco Max
- Serial No.: 118630-1309-0841
- REF: 1186-3-4000
£ 500.00 (ex. VAT) 1 in stock
LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab
ITEM-42425
LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab
This item was removed from a university lab where it surplus to requirement.
It is good cosmetic condition and good working order.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Don Whitley MK3 Anaerobic Bench Top Work Station Spares/Repair
ITEM-42468
Don Whitely MK3 Anaerobic Bench Top Work Station
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition but is not in working order, mainly due to a faulty gas inlet valve.
It powers on with functional temperature control and cooling fans. Key issues include non-working internal power sockets, flashing low CO2 and N2 warning lights, and a broken outer door lock seal knob, which compromises the chamber's sealing.
Due to the faults listed above, this system is listed as Spares/Repair.
Features:
- Uses hydrogen, nitrogen, and carbon dioxide or a standard anaerobic gas mixture.
- Digital temperature controller for constant temperature maintenance.
- Humidistat-controlled condensing plate for excess moisture removal.
- 30-litre interchange lock capable of holding 108 plates with vacuum flushing.
Includes:
- User Instruction Manual
Serial No.: 3170S
£ 500.00 (ex. VAT) 1 in stock
MSE 4 x 750ml Windshield Rotor 43124-708 BS4402 with Buckets Lab
ITEM-42469
MSE 4 x 750ml Windshield Rotor 43124-708 BS 4402 With Buckets
This item was removed from a university laboratory where it was surplus to requirements.
The rotor is in very good condition. It was tested on a compatible centrifuge at its maximum speed of 3660 RPM and operated without issues.
Includes:
- 4 x 750ml MSE buckets
Model: 43124-708 BS 4402
Serial No.: 872183
Max RPM: 3660
Year: 1987
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nikon Eclipse TE 2000-U Inverted Fluorescence Microscope - No Objectives
ITEM-42779
Nikon Eclipse TE2000-U Inverted Microscope with TE-PSE30 Power Supply
This item has been removed from a university laboratory as part of a surplus clearance.
The microscope is incomplete and will require a binocular tube head, objectives, and a stage insert as a minimum for operation.
Due to this, it is being sold as spares or repair.
£ 500.00 (ex. VAT) 1 in stock
Grant FH15 Flow Heater and FC20 Flow Cooler Lab
ITEM-42784
Grant FH15 Flow Heater and FC20 Flow Cooler
This system was removed from a university laboratory where it was surplus to requirements.
The FH15 Flow Heater powered on with the pump running. The heater light illuminated when the set temperature was increased above ambient.
The FC20 Flow Cooler powered on, and both the compressor and fan could be heard operating.
These units do not include a built-in tank and require an external header tank to function as part of a complete system. Due to this, full-range temperature testing was not performed.
It is in good cosmetic condition.
Includes:
- Grant FH15 Flow Heater (Serial No. 72311)
- Grant FC20 Flow Cooler (Serial No. 72311)
- Model: FH15 / FC20
- Serial No.: 72311
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Optima TL Ultracentrifuge w/ Beckman TLA 100.4 Rotor Spares/Repair
ITEM-42968
Beckman Optima TL Ultracentrifuge
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition with minimal wear. However, the unit is non-operational: it does not run programs or operate normally. The door does not open unless the unit is manually stripped down and the door lock pin is pressed.
Additionally, the vacuum chamber does not hold pressure. Error messages displayed include CPU, VAC, and SPD.
Therefore, it is listed as Spares/Repair.
Includes:
- Rotor: Beckman TLA 100.4
- Maximum Speed: 100,000 RPM
- Serial No.: 95U1272
Model: TL
Serial No.: CTL95E13
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Molspin Model Nuvo Vibrating Sample Magnetometer - Spares/Repair 1990
ITEM-43112
Molspin Nuvo Vibrating Sample Magnetometer - Spares/Repair
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition, however the dial is seized, preventing further testing.
Therefore, it is listed as Spares/Repair.
Please note; The previous owner stated it was faulty therefore its possible there are other issues not noted.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Trilec Instrument LTD CMDS 100 Magnetizer Slave Unit Spares/Repair Lab
ITEM-43113
Trilec CMDS 100 Magnetizer Slave Unit Spares/Repair Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however the previous client has stated it was faulty, though the fault was not determined,
Therefore, it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
LTE Scientific Falcon 30 Benchtop Laboratory Autoclave - Spares/Repair Lab
ITEM-46403
LTE Scientific Falcon 30 Benchtop Laboratory Autoclave
This item was removed from a university lab where it was surplus to requirements.
The unit powers on and is in reasonably good cosmetic condition. However, it failed a recent service.
Therefore, it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
PolyScience 6705 Refrigerated Circulator Spares/Repair
ITEM-46442
PolyScience 6705 Refrigerated Circulator
This item was removed from a facility where it was surplus to requirements.
It powers on and is in good cosmetic condition. However, it does not circulate antifreeze, and the unit failed to reach full cooling performance, only achieving a minimum temperature of 6.0°C.
Internal inspection revealed significant corrosion on the elements.
Due to these faults, this item is listed as spares or repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
YSI 2300 230V STAT Plus Glucose Lactate Analyser Spares/Repair Lab
ITEM-46578
YSI 2300 230V STAT Plus Glucose Lactate Analyser Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It powers on and is in reasonably good cosmetic condition, however, there is a missing side panel.
The previous owner had stated it is not in working order, though the reason is unknown.
Therefore, it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
UniSense Fertilitech Embryoscope ES-D Spares/Repair Lab
ITEM-46714
UniSense Fertilitech Embryoscope ES-D Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition but does not power on, therefore it is listed as Spares/Repair.
£ 500.00 (ex. VAT) 1 in stock
Eppendorf A-2-DWP 3,700 rpm Rotor
ITEM-46920
Eppendorf A-2-DWP Rotor
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition. It was unable to be tested further.
Specifications:
- Maximum speed: 3,700 rpm
- Maximum RCF: 2,250 × g
- Capacity: Accommodates up to two deepwell plates, microtiter plates, cell culture plates, or filtration plate kits
- Compatible with Eppendorf Centrifuge models 5804, 5804 R, 5810, and 5810 R
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sorvall RC-28S Floor-Standing Centrifuge Spares/Repair Lab
ITEM-46923
Sorvall RC 28S Floor-Standing Centrifuge Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, testing could not be completed due to an on-screen error that prevented further operation, and prevented a vacuum from being drawn.
Therefore, it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller Spares/Repair Lab
ITEM-47102
Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller
This item was removed from a university laboratory where it was surplus to requirements.
The item is in reasonably good cosmetic condition; however, it cannot be powered on due to the absence of a plug and a split in the flex exposing the internal wires.
It is therefore sold as spares or repair.
Includes:
- Carl Zeiss Surgical Microscope
- Metz NAG 80 VA Controller
£ 500.00 (ex. VAT) 1 in stock
Triple Red Duo Organic 60 Ultra Pure Water Purification System Lab
ITEM-45397
Triple Red Duo Organic 60 Ultra Pure Water Purification System
This item was removed from a university where it was surplus to requirements.
It is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.
Included Components:
- Avidity Carbon Pre-Filter
- P/N: TR-2057
- Install Date: 26/7/23
- Avidity Cartridge Pack
- P/N: TR-2050
- Install Date: 26/7/23
- Avidity Cartridge Polisher
- P/N: TR-2051
- Install Date: 26/7/23
Specifications:
- Model: Organic 60 Ultra Pure Water Purification System
- Serial No.: 0916961-01
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Molecular Dynamics Typhoon 8610 Variable Mode Imager Spares/Repair Lab
ITEM-46070
Molecular Dynamics Typhoon 8610 Variable Mode Imager Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition.
The unit connects to a PC and communicates with the control software; however, when attempting to run a scan it reports errors relating to the filter wheel and laser shutter. The power switch has also been noted to operate intermittently.
Due to these issues, it is listed as Spares/Repair.
£ 500.00 (ex. VAT) 1 in stock
Fujifilm Phosphorus Imager FLA-5000 With Computer And Plates Lab
ITEM-46205
Fujifilm Phosphorus Imager FLA-5000 with Computer and Plates
This system was removed from a university laboratory where it was surplus to requirements.
The system is in good cosmetic condition. We were notified by the previous owner that it was in working order when last in use, however it has not been used regularly for the past 8 years. Given its prolonged inactivity, it is advisable to replace the x-ray tube before use to ensure safety and functionality.
We were unable to test it at our facility due to our safety policy surrounding X-Ray equipment.
Includes:
- G4 Mac PC (Model: M8493)
- Keyboard
- Mouse
- Monitor
- FLA Fluor Stage 4046
- FLA IP Stage 4046
- FLA Multi Stage 4046
- Kodak 2 Safelight Filter
- Filter tray with IP/LPB/LPG/LPR filters
Software Installed:
- L.Process V.2
- Image Gauge 4.0
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab
ITEM-46209
Shimadzu Total Organic Carbon Analyzer TOC-4200
This system was removed from a university laboratory where it was surplus to requirements.
It powers on and is in fair cosmetic condition externally, but the internal condition is poor. The cut cable is an IEC cable.
The following errors were noted during testing, as well as required consumables. - Due to the errors listed, this system is listed as Spares/Repair.
Errors:
- 8PORT VALVE
- DEHUM FAN
Requires Consumables:
- CO2 ABS1
- CO2 ABS2
- PLUNGER TIP
- CATALYST
Model: TOC-4200
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab
ITEM-46210
Shimadzu Total Organic Carbon Analyzer TOC-4200
This system was removed from a university laboratory where it was surplus to requirements.
It powers on and is in fair cosmetic condition externally, but the internal condition is poor. The cut cable is a IEC cable.
The following errors were noted during testing, as well as required consumables. Due to the errors listed, this system is listed as Spares/Repair.
Errors:
- 8PORT VALVE
- DEHUM FAN
- Blown capacitor on communication board.
Requires Consumables:
- CO2 ABS1
- CO2 ABS2
- PLUNGER TIP
- OIL SEAL.
Model: TOC-4200
£ 500.00 (ex. VAT) 1 in stock
Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker Lab
ITEM-46239
Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker
This item was removed from a laboratory where it was surplus to requirements.
The shaker powers on and operates at the maximum RPM of 400.
It is in poor cosmetic condition.
Model: AK-82
£ 500.00 (ex. VAT) 1 in stock
Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker
ITEM-46240
Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker
This item was removed from a laboratory where it was surplus to requirements.
The shaker powers on and operates at the maximum RPM of 400. It is in reasonably good cosmetic condition.
Model: AK-82
£ 500.00 (ex. VAT) 1 in stock
Zeiss CTI 3700 Controller with TempControl 37-2, Heating Unit & CO2 Controller
ITEM-47856
Zeiss CTI 3700 Controller with TempControl 37-2, Heating Unit & CO₂ Controller
This system was removed from a university where it was surplus to requirement.
The system is in good cosmetic condition and powers on. No further functional testing has been carried out.
Included Components:
Zeiss TempControl 37-2 Digital
Model: TempControl 37-2 Digital
S/N: 000000-1052-320
Zeiss CO₂ Controller
Model: CO₂ Controller
S/N: 000000-0445-831
Zeiss Heating Unit
Model: Heating Unit
S/N: 000000-1116-061
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump Spares/Repair Lab
ITEM-48347
Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump – Spares/Repair
This item was removed from a university laboratory where it was surplus to requirements.
It is in good cosmetic condition and powers on; however, the previous owner has stated it is faulty, with the fault unspecified. Supplied with cables for connecting to the rest of a system, along with an Automatic Backpressure Valve (PN-900-13702-000).
Includes:
- Cables for system connection
- Automatic Backpressure Valve (PN-900-13702-000)
£ 500.00 (ex. VAT) 1 in stock
Waters 474 Scanning Fluorescence Detector Lab
ITEM-47645
Waters 474 Scanning Fluorescence Detector Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Includes;
Waters 474 Scanning Fluorescence Detector Operators Guide
£ 500.00 (ex. VAT) 1 in stock
Ohaus Frontier Micro Centrifuge FC5513 Lab
ITEM-49518
Ohaus Frontier Micro Centrifuge FC5513 Lab
This item is sold on behalf of a client where it is surplus to requirements.
This item is in complete working order, and in good cosmetic condition.
The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Spares/Repair Lab
ITEM-49742
Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Spares/Repair Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing the following error was present; Error 17, a PCB fault.
Which prevented any further testing.
It is therefore listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Bellco Biotechnology Production Roller Apparatus Model 7340-10230 Spares/Repair
ITEM-49770
Bellco Biotechnology Production Roller Apparatus (Model 7340-10230) – Spares/Repair
This item was removed from a facility where it was surplus to requirements.
The unit is in poor cosmetic condition and is missing several rollers. The rear panels were loose but have been secured with new nuts and bolts. The item powers on, and the motor can be heard running; however, the rollers do not move at all.
Due to this operational fault and missing components, the unit is offered as Spares/Repair.
Model: 7340-10230
£ 500.00 (ex. VAT) 1 in stock
Reflotron Plus Dry Chemistry Analyser with Reflotron Workstation D
ITEM-49876
Reflotron Plus Dry Chemistry Analyser with Reflotron Workstation D
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Items 2251 to 2300 of 3389