Welcome to UniGreenScheme, your trusted source for high-quality, second-hand laboratory equipment. We specialize in providing cost-effective solutions for labs, universities, and research facilities worldwide, and we are proud to offer an asset resale service specifically designed for universities and laboratories.


From lab water baths to centrifuges, we offer a wide range of tested, reliable equipment to meet all your scientific and industrial needs. Shop with confidence and discover sustainable, high-quality lab solutions today.

Items 2251 to 2300 of 3389

Image of Renishaw Raman Confocal System Parts Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Renishaw Raman Confocal System Parts Lab Spares/Repairs

ITEM-37159

Renishaw Raman Confocal System Parts Lab


None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.


None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.


Included are the following;


1x Renishaw Raman unit


1x Renishaw SYS100 Unit:

Model SYS100


1x Renishaw Laser unit:

Model FOP


1x Renishaw Laser unit:

Model FOP7-514


2x Spectra-Physics Laser Heads:

Model no. 160-C4210


1x Laser Head Power Cable:


1x Interlock Overide Cable B


2x Spectra-Physics Laser Power Supplies:

Model no. 263-C03 714792R-did not power on. - (with enable key).

Model no. 263-C04 - powers on. - (no enable Key).


2x Power Supply Cables


2x Spectra-Physics Remote

Model 361C


1x YC-05II Video Camera


Objectives:


1x RED- Unbranded 4/ 0.10 160/0.17


1x BLUE- Unbranded 40/ 0.65 160/0.17


1x GREEN- Olympus SLMPlan 20X /0.35 ∞ / 0


Image of 11 x Packs Various Thermo Scientific Nalgene Coex Polyethylene Film Tank Liners

NEW ITEM

NEW ITEM

£ 500.00 (ex. VAT) 1 in stock

11 x Packs Various Thermo Scientific Nalgene Coex Polyethylene Film Tank Liners

ITEM-38725

These were removed from a working lab where they were surplus to requirements.


Included are;


Nalgene™ Coex Polyethylene Film Tank Liners x 2

Catalog number: 343050-0005

Description: Gamma Irradiated: 5 gal. (19L)

Material: Polyethylene

Capacity (English) 5 gal.

For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200

No. per Pack 10


Nalgene™ Coex Polyethylene Film Tank Liners x 5

Catalog number: 343050-0030

Description: Gamma Irradiated: 30 gal. (113L)

Material: Polyethylene

Capacity (English) 30 gal.

For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200

No. per Pack 10


Nalgene™ Coex Polyethylene Film Tank Liners x 3

Catalog number: 343050-0007

Description: Gamma Irradiated: 7.5 gal. (28L)

Material: Polyethylene

Capacity (English) 7.5 gal.

For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200

No. per Pack 10


Nalgene™ Coex Polyethylene Film Tank Liners x 1

Catalog number: 343050-0015

Description: Gamma Irradiated: 15 gal. (57L)

Material: Polyethylene

Capacity (English) 15 gal.

For Use With (Equipment) Nalgene cylindrical tanks from 5 gal (19L) to 200

No. per Pack 8


Image of Perkin Elmer 785A UV-VIS Detector Lab

£ 500.00 (ex. VAT) 1 in stock

Perkin Elmer 785A UV-VIS Detector Lab

ITEM-41330

Perkin Elmer 785A UV-VIS Detector Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on, we are unable to test it further at our facility.


Image of Beckman Coulter Avanti J-25 Centrifuge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Beckman Coulter Avanti J-25 Centrifuge Spares/Repair Lab

ITEM-41342

Beckman Coulter Avanti J-25 Centrifuge Lab


This was removed from a lab where it was surplus to requirements.


It failed to power on, it is therefore listed as Spares/Repair.


Image of Sutter Lambda LS Illuminator LB-LS/17 Lab

£ 500.00 (ex. VAT) 1 in stock

Sutter Lambda LS Illuminator LB-LS/17 Lab

ITEM-41429

Sutter Lambda LS Illuminator LB-LS/17


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, but the power switch is stuck in the on position.


We are unable to test it further at our facility.


Lamp Runtime: 05573.7 hours


Image of Leica SP5 Confocoal Laser w/ NEC Monitors For Parts  Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Leica SP5 Confocoal Laser w/ NEC Monitors For Parts Lab

ITEM-41643

Leica SP5 and HP Z620 Workstation System with NEC Monitors - For Parts or Repair


This system was removed from a university lab where it was surplus to requirements.


The setup primarily consists of components from a Leica SP5 system but is currently non-operational and intended for spares or repairs.


This collection of equipment is in need of significant repairs, especially the electrical connections, as noted from the site that "Electrics are bust."


Included Equipment;

  • NEC MultiSync LCD 1990SXi Monitors (2 units): Dual monitors that are part of the system.

  • HP Z620 Workstation PC Tower: Includes a keyboard and mouse but does not have HDDs. It retains PCi cards for the Leica system.

  • Leica SP5 Unit: The operational condition is uncertain. It suffers from severe damage to the umbilical cable, with various wires cut, which affects its functionality.

  • Leica Microsystems CMS TCS SP5 Control Table: Comes with a table, but similar to the SP5 unit, it has umbilical cables that have been severed.

  • Leica Exhaust Unit: Forms part of the ventilation system for the Leica SP5.



Image of Perkin Elmer LS50B Luminescence Spectrometer Lab

£ 500.00 (ex. VAT) 1 in stock

Perkin Elmer LS50B Luminescence Spectrometer Lab

ITEM-38260

This Perkin Elmer LS50B Luminescence Spectrometer was removed from a university lab where it was surplus to requirements.


The unit powers up but has not been tested further at our facility.


It is in good cosmetic condition, with minor marks from use.


The sample plate is not included.


Further testing is not possible without the necessary PC and Software.

Image of Hounsfield H20K-W Tensometer

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Hounsfield H20K-W Tensometer

ITEM-39881

Hounsfield H20K-W Tensometer w/ PSU & Various Parts


This item was removed from a university lab where it was surplus to requirements.


We are unable to test due to the power supply not being included, therefore this item is sold as Spares or Repairs.

Image of Millipore Guava EasyCyte HT Flow Cytometer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Millipore Guava EasyCyte HT Flow Cytometer Lab Spares/Repairs

ITEM-40069

Millipore Guava EasyCyte HT Flow Cytometer


This was removed from a university lab where it was surplus to requirements.


The system is in good cosmetic condition and powers on, however during testing there were undiagnosed issues identified that prevented use.


Therefore, it is listed as Spares/Repair.



Image of DakoCytomation Diode Lyt 200-S Laser Head w/ Controller & Fan/Cooler Lab

£ 500.00 (ex. VAT) 1 in stock

DakoCytomation Diode Lyt 200-S Laser Head w/ Controller & Fan/Cooler Lab

ITEM-41212

DakoCytomation Diode Lyt 200-S Laser Head w/ Controller & Fan/Cooler


This was removed from a working MoFlo system. It was surplus to requirements.


The unit powers up but has not been tested further due to safety restrictions around lasers at our site.


It is in good cosmetic condition with minor marks.

Image of Vacuubrand Vakuum-Pump system BVC 81 VNC 1 Lab

£ 500.00 (ex. VAT) 1 in stock

Vacuubrand Vakuum-Pump system BVC 81 VNC 1 Lab

ITEM-41234

Vacuubrand Vakuum-Pump system BVC 81


This was removed from a university lab where it was surplus to requirements.


The unit powers up and runs. The tube connecting the pump to the bottle has been snapped off, allowing all the air to escape before it converts into the bottle. This tubing will need to be replaced but is a consumable.


Unable to test further at our facility.

Image of Biotage Jones Chromatography Flashmaster II System Lab

£ 500.00 (ex. VAT) 1 in stock

Biotage Jones Chromatography Flashmaster II System Lab

ITEM-20480

This Biotage Jones Chromatography Flashmaster II System was removed from a university lab where it was surplus to requirements.


The unit powers on and is in very good cosmetic condition. It has not been tested further at our facility.


There is some chipped paint along the top of the unit and scuffs and scratches from general use.

Image of Advanced Analytical Fragment Analyzer Automated CE System Lab

£ 500.00 (ex. VAT) 1 in stock

Advanced Analytical Fragment Analyzer Automated CE System Lab

ITEM-31907

Advanced Analytical Fragment Analyzer Automated CE System


This was removed from a university lab where it was surplus to requirements.


The unit powers up but was supplied without software so we have been unable to test it further.


It is in good cosmetic condition with minor marks from use.

Image of Antec Scientific Alexys 100 LC-EC System Lab -  AC 100, LC 110, AS 100, LC 100

£ 500.00 (ex. VAT) 1 in stock

Antec Scientific Alexys 100 LC-EC System Lab - AC 100, LC 110, AS 100, LC 100

ITEM-25232



This Antec Scientific Alexys 100 LC-EC System was removed from a university lab where it was surplus to requirements.


All the modules power up but have not been tested further at our facility. It is in good cosmetic condition with only minor marks from use.


The lab informed us that it was working fine before it was put away about 5 years ago.


There are a number of consumables included with it.


The system includes;


1x LC 100

Part No. 182.0035


1x AC 100

Part No. 183.0035


1x LC 110

Part No. 193.0035


1x AS 100

Part No. 181.0037


1x Decade II

Part No. 171.0035


1x OPR

Part No. 184.0035

Image of Perkin Elmer Fluorescence 204 Spectrophotometer Analyser Laboratory Equipment

£ 500.00 (ex. VAT) 1 in stock

Perkin Elmer Fluorescence 204 Spectrophotometer Analyser Laboratory Equipment

ITEM-06749

This was removed from a university lab where it was surplus to requirements


The unit powers up but has not been tested further.


It is in reasonably good cosmetic condition with minor marks.

Image of Prior PL012 Binocular Microscope With 4 x Objectives Lab

£ 500.00 (ex. VAT) 1 in stock

Prior PL012 Binocular Microscope With 4 x Objectives Lab

ITEM-44462

Prior PL012 Binocular Microscope With 4 x Objectives


This item was removed from a university lab where it was surplus to requirements.


It powers on and is in reasonably good cosmetic condition.


Includes 4 x objectives:

  • EA 100 Oil 1.25 160/0.17 (clear image could not be obtained)
  • EA 4 0.10 160/-
  • EA 10 0.25 160/-
  • EA 40 0.65/0.17 (clear image could not be obtained)

2 x WF 10X/20 Eyepiece.


Model: PL012

S/N: 57403

Image of Leica AODS 20200-8 Laser Modulator Lab

£ 500.00 (ex. VAT) 1 in stock

Leica AODS 20200-8 Laser Modulator Lab

ITEM-44501

Leica AODS 20200-8 Laser Modulator Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


Power supply not included.

Image of Sanyo MDF-U442 Medical Freezer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Sanyo MDF-U442 Medical Freezer Lab Spares/Repairs

ITEM-44667

Sanyo MDF-U442 Medical Freezer Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, but it is not functional as it stays at ambient room temperature and triggers the alarm when the desired temperature is set.


Therefore, it is listed as Spares/Repair.

Image of Bio-Rad UltraMark Microplate Imaging System

£ 500.00 (ex. VAT) 1 in stock

Bio-Rad UltraMark Microplate Imaging System

ITEM-45008



Bio-Rad UltraMark Microplate Imaging System


This item was removed from a university where it was surplus to requirement.


The unit powers up and is in good working order (thermometer not included).

It is in fair cosmetic condition.


No controller or additional equipment included to adjust the temperature.


Model: Ultramark.

Image of Job Lot of 13 Vintage Microtome Knives With Sharpening strops and Whetstones

£ 500.00 (ex. VAT) 1 in stock

Job Lot of 13 Vintage Microtome Knives With Sharpening strops and Whetstones

ITEM-42018

Job Lot of 13 Vintage Microtome Knives With Sharpening Strops and Whetstones


These items were removed from a university lab, where they were surplus to requirement.


The knife blades are all in very good condition, with sharp and undamaged cutting edges, appearing to have been well maintained, except for the hand knife, which has a poor cutting edge.


The wooden boxes are in excellent condition, except for two that are damaged.


The lot comprises:


  • 3 x Shandon Nothung C wedge shape 20cm blades (circa 1967) in box
  • 1 x Shandon Northung A concave 25cm blade (circa 1967) in box
  • 1 x Unidentified C wedge 18cm blade in box
  • 3 x MSE Ltd No. 9057.W wedge 9cm blades in box
  • 2 x Cambridge Instruments rocking microtome knives (10cm blades) in box
  • 1 x Unidentified wedge 8cm blade in leather case
  • 1 x Hand knife with handle in poor condition in box
  • 4 x Leather sharpening strops (30-35cm long), 2 in box
  • 2 x 15cm whetstones
  • 1 x Acrylic 15cm sharpener
  • 1 x 25cm blade holder
  • 3 x 20cm blade holders
  • 1 x 17cm blade holder
Image of Protec Eco Max X-Ray Film Processor Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Protec Eco Max X-Ray Film Processor Lab Spares/Repairs

ITEM-42060



Protec Eco Max X-Ray Film Processor


This item was removed from a university laboratory where it was surplus to requirements.


The unit powers on and is in fair condition with some wear. There are some spots of rust, and the baseplate is missing. Therefore, resulting in a visual PAT fail.


It is listed as Spares/Repair.


Specifications:

  • Model: Eco Max
  • Serial No.: 118630-1309-0841
  • REF: 1186-3-4000
Image of LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab

£ 500.00 (ex. VAT) 1 in stock

LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab

ITEM-42425


LEEC Hot and Cold Laboratory Incubator Model PFC2CK Lab


This item was removed from a university lab where it surplus to requirement.


It is good cosmetic condition and good working order.

Image of Don Whitley MK3 Anaerobic Bench Top Work Station Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Don Whitley MK3 Anaerobic Bench Top Work Station Spares/Repair

ITEM-42468

Don Whitely MK3 Anaerobic Bench Top Work Station


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition but is not in working order, mainly due to a faulty gas inlet valve.


It powers on with functional temperature control and cooling fans. Key issues include non-working internal power sockets, flashing low CO2 and N2 warning lights, and a broken outer door lock seal knob, which compromises the chamber's sealing.


Due to the faults listed above, this system is listed as Spares/Repair.


Features:

  • Uses hydrogen, nitrogen, and carbon dioxide or a standard anaerobic gas mixture.
  • Digital temperature controller for constant temperature maintenance.
  • Humidistat-controlled condensing plate for excess moisture removal.
  • 30-litre interchange lock capable of holding 108 plates with vacuum flushing.

Includes:

  • User Instruction Manual

Serial No.: 3170S

Image of MSE 4 x 750ml Windshield Rotor 43124-708 BS4402 with Buckets Lab

£ 500.00 (ex. VAT) 1 in stock

MSE 4 x 750ml Windshield Rotor 43124-708 BS4402 with Buckets Lab

ITEM-42469

MSE 4 x 750ml Windshield Rotor 43124-708 BS 4402 With Buckets


This item was removed from a university laboratory where it was surplus to requirements.


The rotor is in very good condition. It was tested on a compatible centrifuge at its maximum speed of 3660 RPM and operated without issues.


Includes:

  • 4 x 750ml MSE buckets

Model: 43124-708 BS 4402

Serial No.: 872183

Max RPM: 3660

Year: 1987

Image of Nikon Eclipse TE 2000-U Inverted Fluorescence Microscope - No Objectives

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Nikon Eclipse TE 2000-U Inverted Fluorescence Microscope - No Objectives

ITEM-42779

Nikon Eclipse TE2000-U Inverted Microscope with TE-PSE30 Power Supply


This item has been removed from a university laboratory as part of a surplus clearance.


The microscope is incomplete and will require a binocular tube head, objectives, and a stage insert as a minimum for operation.


Due to this, it is being sold as spares or repair.

Image of Grant FH15 Flow Heater and FC20 Flow Cooler Lab

£ 500.00 (ex. VAT) 1 in stock

Grant FH15 Flow Heater and FC20 Flow Cooler Lab

ITEM-42784

Grant FH15 Flow Heater and FC20 Flow Cooler


This system was removed from a university laboratory where it was surplus to requirements.


The FH15 Flow Heater powered on with the pump running. The heater light illuminated when the set temperature was increased above ambient.

The FC20 Flow Cooler powered on, and both the compressor and fan could be heard operating.


These units do not include a built-in tank and require an external header tank to function as part of a complete system. Due to this, full-range temperature testing was not performed.

It is in good cosmetic condition.


Includes:

  • Grant FH15 Flow Heater (Serial No. 72311)
  • Grant FC20 Flow Cooler (Serial No. 72311)

  • Model: FH15 / FC20
  • Serial No.: 72311
Image of Beckman Optima TL Ultracentrifuge w/ Beckman TLA 100.4 Rotor Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Beckman Optima TL Ultracentrifuge w/ Beckman TLA 100.4 Rotor Spares/Repair

ITEM-42968

Beckman Optima TL Ultracentrifuge


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in good cosmetic condition with minimal wear. However, the unit is non-operational: it does not run programs or operate normally. The door does not open unless the unit is manually stripped down and the door lock pin is pressed.

Additionally, the vacuum chamber does not hold pressure. Error messages displayed include CPU, VAC, and SPD.


Therefore, it is listed as Spares/Repair.


Includes:

  • Rotor: Beckman TLA 100.4
  • Maximum Speed: 100,000 RPM
  • Serial No.: 95U1272

Model: TL

Serial No.: CTL95E13

Image of Molspin Model Nuvo Vibrating Sample Magnetometer - Spares/Repair 1990

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Molspin Model Nuvo Vibrating Sample Magnetometer - Spares/Repair 1990

ITEM-43112

Molspin Nuvo Vibrating Sample Magnetometer - Spares/Repair


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition, however the dial is seized, preventing further testing.


Therefore, it is listed as Spares/Repair.


Please note; The previous owner stated it was faulty therefore its possible there are other issues not noted.

Image of Trilec Instrument LTD CMDS 100 Magnetizer Slave Unit Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Trilec Instrument LTD CMDS 100 Magnetizer Slave Unit Spares/Repair Lab

ITEM-43113

Trilec CMDS 100 Magnetizer Slave Unit Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on, however the previous client has stated it was faulty, though the fault was not determined,


Therefore, it is listed as Spares/Repair.

Image of LTE Scientific Falcon 30 Benchtop Laboratory Autoclave - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

LTE Scientific Falcon 30 Benchtop Laboratory Autoclave - Spares/Repair Lab

ITEM-46403

LTE Scientific Falcon 30 Benchtop Laboratory Autoclave


This item was removed from a university lab where it was surplus to requirements.


The unit powers on and is in reasonably good cosmetic condition. However, it failed a recent service.


Therefore, it is listed as Spares/Repair.

Image of PolyScience 6705 Refrigerated Circulator Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

PolyScience 6705 Refrigerated Circulator Spares/Repair

ITEM-46442

PolyScience 6705 Refrigerated Circulator


This item was removed from a facility where it was surplus to requirements.


It powers on and is in good cosmetic condition. However, it does not circulate antifreeze, and the unit failed to reach full cooling performance, only achieving a minimum temperature of 6.0°C.


Internal inspection revealed significant corrosion on the elements.


Due to these faults, this item is listed as spares or repair.

Image of YSI 2300 230V STAT Plus Glucose Lactate Analyser Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

YSI 2300 230V STAT Plus Glucose Lactate Analyser Spares/Repair Lab

ITEM-46578

YSI 2300 230V STAT Plus Glucose Lactate Analyser Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It powers on and is in reasonably good cosmetic condition, however, there is a missing side panel.


The previous owner had stated it is not in working order, though the reason is unknown.


Therefore, it is listed as Spares/Repair.

Image of UniSense Fertilitech Embryoscope ES-D Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

UniSense Fertilitech Embryoscope ES-D Spares/Repair Lab

ITEM-46714

UniSense Fertilitech Embryoscope ES-D Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in good cosmetic condition but does not power on, therefore it is listed as Spares/Repair.

Image of Eppendorf A-2-DWP 3,700 rpm Rotor

£ 500.00 (ex. VAT) 1 in stock

Eppendorf A-2-DWP 3,700 rpm Rotor

ITEM-46920

Eppendorf A-2-DWP Rotor


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition. It was unable to be tested further.


Specifications:

  • Maximum speed: 3,700 rpm
  • Maximum RCF: 2,250 × g
  • Capacity: Accommodates up to two deepwell plates, microtiter plates, cell culture plates, or filtration plate kits
  • Compatible with Eppendorf Centrifuge models 5804, 5804 R, 5810, and 5810 R

Image of Sorvall RC-28S Floor-Standing Centrifuge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Sorvall RC-28S Floor-Standing Centrifuge Spares/Repair Lab

ITEM-46923

Sorvall RC 28S Floor-Standing Centrifuge Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on, however, testing could not be completed due to an on-screen error that prevented further operation, and prevented a vacuum from being drawn.


Therefore, it is listed as Spares/Repair.

Image of Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller Spares/Repair Lab

ITEM-47102

Carl Zeiss Surgical Microscope + Metz NAG 80 VA Controller


This item was removed from a university laboratory where it was surplus to requirements.


The item is in reasonably good cosmetic condition; however, it cannot be powered on due to the absence of a plug and a split in the flex exposing the internal wires.


It is therefore sold as spares or repair.


Includes:

  • Carl Zeiss Surgical Microscope
  • Metz NAG 80 VA Controller

Image of Triple Red Duo Organic 60 Ultra Pure Water Purification System Lab

£ 500.00 (ex. VAT) 1 in stock

Triple Red Duo Organic 60 Ultra Pure Water Purification System Lab

ITEM-45397

Triple Red Duo Organic 60 Ultra Pure Water Purification System


This item was removed from a university where it was surplus to requirements.


It is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.


Included Components:

  • Avidity Carbon Pre-Filter
  • P/N: TR-2057
  • Install Date: 26/7/23
  • Avidity Cartridge Pack
  • P/N: TR-2050
  • Install Date: 26/7/23
  • Avidity Cartridge Polisher
  • P/N: TR-2051
  • Install Date: 26/7/23

Specifications:

  • Model: Organic 60 Ultra Pure Water Purification System
  • Serial No.: 0916961-01

Image of Molecular Dynamics Typhoon 8610 Variable Mode Imager Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Molecular Dynamics Typhoon 8610 Variable Mode Imager Spares/Repair Lab

ITEM-46070

Molecular Dynamics Typhoon 8610 Variable Mode Imager Spares/Repair Lab


This item was removed from a university lab where it was surplus to requirement.


It is in reasonably good cosmetic condition.


The unit connects to a PC and communicates with the control software; however, when attempting to run a scan it reports errors relating to the filter wheel and laser shutter. The power switch has also been noted to operate intermittently.


Due to these issues, it is listed as Spares/Repair.

Image of Fujifilm Phosphorus Imager FLA-5000 With Computer And Plates Lab

£ 500.00 (ex. VAT) 1 in stock

Fujifilm Phosphorus Imager FLA-5000 With Computer And Plates Lab

ITEM-46205

Fujifilm Phosphorus Imager FLA-5000 with Computer and Plates


This system was removed from a university laboratory where it was surplus to requirements.


The system is in good cosmetic condition. We were notified by the previous owner that it was in working order when last in use, however it has not been used regularly for the past 8 years. Given its prolonged inactivity, it is advisable to replace the x-ray tube before use to ensure safety and functionality.


We were unable to test it at our facility due to our safety policy surrounding X-Ray equipment.


Includes:

  • G4 Mac PC (Model: M8493)
  • Keyboard
  • Mouse
  • Monitor
  • FLA Fluor Stage 4046
  • FLA IP Stage 4046
  • FLA Multi Stage 4046
  • Kodak 2 Safelight Filter
  • Filter tray with IP/LPB/LPG/LPR filters

Software Installed:

  • L.Process V.2
  • Image Gauge 4.0

Image of Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab

ITEM-46209

Shimadzu Total Organic Carbon Analyzer TOC-4200


This system was removed from a university laboratory where it was surplus to requirements.


It powers on and is in fair cosmetic condition externally, but the internal condition is poor. The cut cable is an IEC cable.


The following errors were noted during testing, as well as required consumables. - Due to the errors listed, this system is listed as Spares/Repair.


Errors:

  • 8PORT VALVE
  • DEHUM FAN

Requires Consumables:

  • CO2 ABS1
  • CO2 ABS2
  • PLUNGER TIP
  • CATALYST

Model: TOC-4200

Image of Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Shimadzu Total Organic Carbon Analyzer TOC-4200 Spares/Repair Lab

ITEM-46210

Shimadzu Total Organic Carbon Analyzer TOC-4200


This system was removed from a university laboratory where it was surplus to requirements.


It powers on and is in fair cosmetic condition externally, but the internal condition is poor. The cut cable is a IEC cable.


The following errors were noted during testing, as well as required consumables. Due to the errors listed, this system is listed as Spares/Repair.


Errors:

  • 8PORT VALVE
  • DEHUM FAN
  • Blown capacitor on communication board.

Requires Consumables:

  • CO2 ABS1
  • CO2 ABS2
  • PLUNGER TIP
  • OIL SEAL.

Model: TOC-4200

Image of Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker  Lab

£ 500.00 (ex. VAT) 1 in stock

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker Lab

ITEM-46239

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker


This item was removed from a laboratory where it was surplus to requirements.


The shaker powers on and operates at the maximum RPM of 400.

It is in poor cosmetic condition.


Model: AK-82

Image of Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker

£ 500.00 (ex. VAT) 1 in stock

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker

ITEM-46240

Infors AG CH-4103 Bottmingen HT TR-225 AK-82 Shaker


This item was removed from a laboratory where it was surplus to requirements.


The shaker powers on and operates at the maximum RPM of 400. It is in reasonably good cosmetic condition.


Model: AK-82

Image of Zeiss CTI 3700 Controller with TempControl 37-2, Heating Unit & CO2 Controller

£ 500.00 (ex. VAT) 1 in stock

Zeiss CTI 3700 Controller with TempControl 37-2, Heating Unit & CO2 Controller

ITEM-47856

Zeiss CTI 3700 Controller with TempControl 37-2, Heating Unit & CO₂ Controller


This system was removed from a university where it was surplus to requirement.


The system is in good cosmetic condition and powers on. No further functional testing has been carried out.


Included Components:


Zeiss TempControl 37-2 Digital

Model: TempControl 37-2 Digital

S/N: 000000-1052-320


Zeiss CO₂ Controller

Model: CO₂ Controller

S/N: 000000-0445-831


Zeiss Heating Unit

Model: Heating Unit

S/N: 000000-1116-061

Image of Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump Spares/Repair Lab

ITEM-48347

Spectrum Labs KrosFlo TFF System KR2i Peristaltic Pump – Spares/Repair


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition and powers on; however, the previous owner has stated it is faulty, with the fault unspecified. Supplied with cables for connecting to the rest of a system, along with an Automatic Backpressure Valve (PN-900-13702-000).


Includes:


  • Cables for system connection
  • Automatic Backpressure Valve (PN-900-13702-000)
Image of Waters 474 Scanning Fluorescence Detector Lab

£ 500.00 (ex. VAT) 1 in stock

Waters 474 Scanning Fluorescence Detector Lab

ITEM-47645

Waters 474 Scanning Fluorescence Detector Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


Includes;


Waters 474 Scanning Fluorescence Detector Operators Guide

Image of Ohaus Frontier Micro Centrifuge FC5513 Lab

£ 500.00 (ex. VAT) 1 in stock

Ohaus Frontier Micro Centrifuge FC5513 Lab

ITEM-49518

Ohaus Frontier Micro Centrifuge FC5513 Lab


This item is sold on behalf of a client where it is surplus to requirements.


This item is in complete working order, and in good cosmetic condition.


The normal terms and conditions do not apply to this item. This item is non returnable and non refundable.

Image of Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Spares/Repair Lab

ITEM-49742

Eppendorf 5804 R Centrifuge w/ A-4-62 Rotor Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however during testing the following error was present; Error 17, a PCB fault.


Which prevented any further testing.


It is therefore listed as Spares/Repair.

Image of Bellco Biotechnology Production Roller Apparatus Model 7340-10230 Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 500.00 (ex. VAT) 1 in stock

Bellco Biotechnology Production Roller Apparatus Model 7340-10230 Spares/Repair

ITEM-49770

Bellco Biotechnology Production Roller Apparatus (Model 7340-10230) – Spares/Repair


This item was removed from a facility where it was surplus to requirements.


The unit is in poor cosmetic condition and is missing several rollers. The rear panels were loose but have been secured with new nuts and bolts. The item powers on, and the motor can be heard running; however, the rollers do not move at all.


Due to this operational fault and missing components, the unit is offered as Spares/Repair.


Model: 7340-10230

Image of Reflotron Plus Dry Chemistry Analyser with Reflotron Workstation D

£ 500.00 (ex. VAT) 1 in stock

Reflotron Plus Dry Chemistry Analyser with Reflotron Workstation D

ITEM-49876

Reflotron Plus Dry Chemistry Analyser with Reflotron Workstation D


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, we are unable to test it further at our facility.


Items 2251 to 2300 of 3389

Filters

Price (£)

to

Condition

Category filters

Recertification Initial Checks

Overall Cosmetic Condition (tested value)