Spectroscopy and Chemical Analysis
Items 151 to 200 of 201

£ 650.00 (ex. VAT) 1 in stock
Pharmia Biotech Ultrospec 2000 UV/Visible Spectrophotometer Lab
ITEM-42358
Pharmia Biotech Ultrospec 2000 UV/Visible Spectrophotometer Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition, powers on and successfully passed all self-tests.
Specifications;
- Model 80-2106-00
- Serial No. 61890

£ 635.00 (ex. VAT) 1 in stock
Perkin Elmer LS50B Luminescence Spectrometer Lab
ITEM-35401
This Perkin Elmer LS50B Luminescence Spectrometer was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further at our facility.
It is in good cosmetic condition with minor marks from use.

£ 630.00 (ex. VAT) 1 in stock
VWR V-3000PC Visible Spectrophotometer Lab
ITEM-35271
This VWR V-3000PC Visible Spectrophotometer was removed from a university lab where it was surplus to requirements.
The unit powers up and starts a 15 min preheat. After this, it asks if it was to be calibrated or not. We have not tested it further.
It is in good cosmetic condition with marks from use.

£ 595.00 (ex. VAT) 1 in stock
Sciex Pulser Module PN 025195 for Mass Spectrometer System Lab
ITEM-28187
Sciex Pulser Module PN 025195
This was removed from a university lab where it was surplus to requirements.
The item is in a reasonable, used cosmetic condition but is untested.
Sciex Pulser Module
025195
x

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 595.00 (ex. VAT) 1 in stock
Bruker ImagePrep Sample Preparation Matrix Deposition Device Lab Faulty
ITEM-19309
This Bruker ImagePrep Sample Preparation Matrix Deposition Device was removed from a university lab where it was surplus to requirements.
The unit is in good used cosmetic condition but it does have some marks and signs of use.
It powers up fine and we have been through a few of the menus and they all work as they should. We were unable to test further as it requires a gas supply etc. We were told by the lab manager that it needed additional parts to make it operational, though we are unsure what exactly the fault is.
It comes with a touch pen.

£ 595.00 (ex. VAT) 1 in stock
Applied Biosystems NanoSpray II MDS SCIEX Assy no. 1014665 for Mass Spec Lab
ITEM-28191
Applied Biosystems NanoSpray II MDS SCIEX Assy no. 1014665
This was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition but has not been tested.
Applied Biosystems NanoSpray II
MDS SCIEX
Assy no. 1014665
SN - 0001042805

£ 520.00 (ex. VAT) 1 in stock
Roche Reflotron Plus Dry Chemistry Analyser Lab
ITEM-24198
This Roche Reflotron Plus Dry Chemistry Analyser was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further at our facility.
It is in good cosmetic condition with some fairly minor marks from use.

£ 510.00 (ex. VAT) 1 in stock
Jobin Yvon Horiba CCD-3500V Detection Unit Lab
ITEM-35891
Jobin Yvon Horiba CCD-3500V Detection Unit
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in good cosmetic condition with minor marks.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Hitachi F-4500 Fluorescence Spectrophotometer System Spares/Repair Lab
ITEM-42393
Hitachi F-4500 Fluorescence Spectrophotometer System
This item was removed from a university laboratory where it was surplus to requirements.
The Hitachi F-4500 unit does not power on; however, it is in good condition with minimal wear. The previous owner said the PSU had failed.
Due to it not powering on it is listed as Spares/Repair
Includes:
- Vigen Genie P3 500 Computer
- Model: F-4500
- Serial No.: 1163-004
- Software: F-4500 FL_mnu - 2504060-05.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Shimadzu Total Organic Carbin Analyzer TOC-4200 Spares/Repair Lab
ITEM-46210
Shimadzu Total Organic Carbon Analyzer TOC-4200
This system was removed from a university laboratory where it was surplus to requirements.
It powers on and is in fair cosmetic condition externally, but the internal condition is poor. The cut cable is a IEC cable.
The following errors were noted during testing, as well as required consumables. Due to the errors listed, this system is listed as Spares/Repair.
Errors:
- 8PORT VALVE
- DEHUM FAN
- Blown capacitor on communication board.
Requires Consumables:
- CO2 ABS1
- CO2 ABS2
- PLUNGER TIP
- OIL SEAL.
Model: TOC-4200

£ 500.00 (ex. VAT) 1 in stock
Jenway 6100 Visible Range Spectrophotometer Lab
ITEM-42369
Jenway 6100 Visible Range Spectrophotometer
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to conduct further testing at our facility.

£ 500.00 (ex. VAT) 1 in stock
Camspec Model M508 Spectrophotometer Lab
ITEM-46073
Camspec M508 Spectrophotometer
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition. We are unable to test it further at our facility.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Cecil CE 7200 Spectrometer Lab Spares/Repairs
ITEM-46062
Cecil CE 7200 Spectrometer Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, the display screen is damaged.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Cecil Type CE 7200 Spectrometer Lab Faulty Screen
ITEM-46061
Cecil Type CE 7200 Spectrometer Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, however, the display screen is damaged.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Varian Saturn 2000/2000R Mass Spec Lab Faulty
ITEM-45385
Varian Saturn 2000/2000R Mass Spectrometer
This item was removed from a university laboratory where it was surplus to requirements.
The mass spectrometer is in reasonably good cosmetic condition but has not been powered on, as it failed PAT testing on visual inspection. The kettle lead port is damaged and will require repair before the unit can be safely used.
As we are unable to power it on, we cannot determine any internal damage that may be present.
Due to its current condition, this item is being sold as-is for spares or repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Wallac 1450 Microbeta Trilux Liquid Scintillation -19994 Lab Spares/Repairs
ITEM-19994
Wallac 1450 Microbeta Trilux Liquid Scintillation
The system tripped ad RCD on the main supply during testing. The internal PSU has shorted.
It is sold for spares/repairs.
Included are;
Microbeta V4.6 Protocol Disk
1450 Microbeta Trilux Main Program 4.6
Comes with:-
Belinea 15" Monitor - Powers on
HP Keyboard
Logitech Mouse
HP Vectra VL5/166 MMX Series 5 DT - PC Does not power on. HDD removed. We left it with the system in case it has useful PCI cards.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Job Lot of Enraf Nonius Delft X-Ray System Units
ITEM-21109
The unit was removed from a university lab. It has not been tested at our facility.
This job lot of items comes from a university lab, The items were no longer required.
None of these items have been tested at our site - it is likely that some will be spares / repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle and further investment in each individual product may be required. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
Included are;
Enraf Nonius Goniometer Control Unit
Type 0590.821
Serial No. 042
Enraf Nonius main processing unit
Type 1546.801
Serial No. 19-19
Jobin Yvon Horiba PC without HDD
Bruker Nonius X-Ray Control
Type 1590.830
Serial 24-04
Enraf Nonius Delft x-ray station with Thomson Tubes X-Ray Head
Enraf Nonius Pocket Terminal
Serial No. 69786R
2 x Huber mechanical adjusting blocks
Part Nos. D83253 D8219
4 x Software disks Cad4- PC Software V1.5c 3.5
Connecting cables and data leads

£ 500.00 (ex. VAT) 1 in stock
Parr Isoperibol Calorimeter 1261EA w/ Power Supply & Printer Lab Spares/Repairs
ITEM-24968
This Parr Isoperibol Calorimeter 240 was removed from a university lab where it was surplus to requirements.
The item is in reasonable cosmetic condition but has plenty of marks from use and age.
The item powered on fine and we could interact with the control panel without issue. We attempted to run a test print and were met with Error 3800. We are told this is due to the O2 requirement and is not a fault with the system.
The system was serviced in 2020 not long before it came to us.
We were unable to test it further.
Also included are the following:
1x Parr 1755 Printer
1x Parr/Star Power Supply
Model: AD8340

£ 495.00 (ex. VAT) 1 in stock
Gallenkamp Digital Flame Analyser FGA-350-L w/ Lafert Air Compressor Pump Lab
ITEM-24780
This Gallenkamp Digital Flame Analyser FGA-350-L was removed from a university lab where it was surplus to requirements.
The system powers up and is in good cosmetic condition with minor marks from use. We were able to get it to produce a spark.
The lab confirmed that it was working prior to removal.
With it is;
1 x Lafert air compressor pump:
Model LM 63/4
The unit powers up but has not been tested further.

£ 450.00 (ex. VAT) 15 in stock
Camspec M508 Spectrophotometer Lab
ITEM-46072
Camspec M508 Spectrophotometer
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition. We are unable to test it further at our facility.
Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving upon purchase before it is shipped, we would be happy to provide this.

£ 450.00 (ex. VAT) 1 in stock
Chromex 250IS Imaging Spectrograph Lab
ITEM-24484
This Chromex 250IS Imaging Spectrograph was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further.
It is in reasonable cosmetic condition with marks from age and use.

£ 450.00 (ex. VAT) 1 in stock
Perkin Elmer Fluorescence Spectrometer Model - LS 45 Lab
ITEM-24559
This Perkin Elmer Fluorescence Spectrometer Model - LS 45 was removed from a university lab where it was surplus to requirements.
The system has been serviced and recertified and is in full working order. We have a full report available on request.
There is no software included
It is in excellent cosmetic condition and is supplied with the following;
1 x LS50B S/W Upgrade to LS 55 Issue B - some items are missing.
1 x Box labelled L225-8000

£ 425.00 (ex. VAT) 1 in stock
Jobin Yvon Horiba CCD-3000V Detection Unit Lab
ITEM-35521
This Jobin Yvon Horiba CCD-3000V Detection Unit was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in good cosmetic condition with minor marks.

£ 400.00 (ex. VAT) 1 in stock
Agilent Technologies G7167-60005 Sample Thermostat Lab
ITEM-44475
Agilent Technologies G7167-60005 Sample Thermostat Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it further at our facility.

£ 350.00 (ex. VAT) 3 in stock
Hitachi U-1900 UV-VIS Spectrophotometer Lab
ITEM-20143
This Hitachi U-1900 UV-VIS Spectrophotometer was removed from a university lab where it was surplus to requirements.
The units power up but have not been tested further.
It is in good cosmetic condition with some marks from use.
Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving before it is shipped, we would be happy to provide this.

£ 350.00 (ex. VAT) 1 in stock
CEM Corporation Discover System Microwave Assisted Model 908010 Lab
ITEM-23322
This CEM Corporation Discover System Microwave Assisted Model 908010 was removed from a university lab where it was surplus to requirements.
The item powers on but has not been tested any further.
The item is in a reasonable, used cosmetic condition apart from the LCD display cover, which is damaged but can still be read.

£ 300.00 (ex. VAT) 1 in stock
Merck Hitachi L-7480 Fluorescence Detector & Software SS420x Interface Unit
ITEM-23393
Merck Hitachi Fluorescence Detector & Scientific Software SS420x Interface Unit
This was removed from a university lab where it was surplus to requirements.
Included in the system are;
1 x Hitachi Fluorescence Detector
Model - L-7480
Part no. 810-0482
The unit powers up but we were unable to test it further.
The lamp was changed last on 8/12/04
Scientific Software inc. SS420x Interface Unit.
The unit powers up but we were unable to test it further.
Both units are in a reasonable used cosmetic condition with some marks from use.

£ 270.00 (ex. VAT) 1 in stock
6 x Hollow Cathode Ray Lamps for AA System S&J, Philips, Varian, Photron Lab
ITEM-32082
These were removed from a university lab where it was surplus to requirements.
We were unable to test these.
Included are;
1x S&J Juniper Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318.5
Cat/N: 4166
S/N: 901315
1x S&J Juniper Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318.5
Cat/N: 4166
S/N: 2123E
1x S&J Juniper Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318
S/N: 3535
1x Philips Data Coded Hollow Cathode Lamp
Element: Vanadium
Wavelength: 318.5
Cat/N: 9423 390 30231
S/N: S 64401
1x Varian Techtron Hollow Cathode Lamp
Element: Zink
Cat/N: 4N559
1x Photron Hollow Cathode Lamp
Element: Tellurium
Wavelength: 214.3
Cat/N: 4166
S/N: 2437

£ 250.00 (ex. VAT) 1 in stock
Thermo Electron Faimes Wave Form Generator Lab
ITEM-38333
This Thermo Faimes Wave Form Generator was removed from a university lab where it was surplus to requirements.
The unit is in reasonably good cosmetic condition but has some marks from use.
It powers up with pump sounding, we are unable to test it further at our facility.

£ 250.00 (ex. VAT) 1 in stock
Merck Hitachi F-1050 Fluorescence Spectrophotometer Lab
ITEM-44419
Merck Hitachi F-1050 Fluorescence Spectrophotometer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
The previous client has stated it was in working condition prior to removal.

£ 250.00 (ex. VAT) 1 in stock
TSP SpectraSYSTEM UV1000 Single Wavelength UV/VIS Programmable Detector Lab
ITEM-28238
This TSP SpectraSYSTEM UV1000 Single Wavelength UV/VIS Programmable Detector was removed from a university lab where it was surplus to requirements.
The item powers on and is in a reasonable, used cosmetic condition apart from a crack on the front of the left-hand side of the unit.
When powered on the unit runs self-tests and all have passed.
Deuterium Lamp hours - 615

RECERTIFIED ITEM
RECERTIFIED ITEM
£ 250.00 (ex. VAT) 1 in stock
Jenway 6505 UV/VIS Spectrophotometer Lab (No Application/Data Card)
ITEM-28230
This Jenway 6505 UV/Vis Spectrophotometer was removed from a university lab where it was surplus to requirements.
The unit powers up but it does not have an application card. It was professionally serviced using a card from another unit (not included).
Instrument passed calibration tests
Wavelength Calibration Tests - PASS
Photometric Calibration Tests - PASS
Stray Light Checks - PASS
It is in reasonably good cosmetic condition with some marks from use.

£ 250.00 (ex. VAT) 1 in stock
Perkin Elmer Lambda 20 UV/Vis Spectrometer Lab
ITEM-46252
Perkin Elmer Lambda 20 UV/Vis Spectrometer
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition and powers on, we are unable to test it further at our facility.

£ 250.00 (ex. VAT) 1 in stock
Job Lot 34x Hollow Cathode Lamps AAS Instrument Laboratory, Visimax, Philips Lab
ITEM-24529
Job Lot of 34 Hollow Cathode Lamps
This was removed from a university lab where it was surplus to requirements.
These have all been tested by a manufacturer trained engineer using a Varian SpectrAA Atomic Absorption Spectrometer Model - 220FS)) and these are the results for that (no further test have been done):
Photron Hollow Cathode Lamp - Element: Na, Sodium (PN-P852) SN-4589. Working
Visimax I Hollow Cathode Lamp - Element: Zn (Cat no-62311). Working
Visimax I Hollow Cathode Lamp - Element: Yb (Cat no-062983-00). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Chromium Cr. (Cat no-89211). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Cobalt, Co (Cat no-89212). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Selenium, Se (Cat no-89249). Working
Instrument Laboratory Hollow Cathode Lamp - Element: Magnesium, Mg (Cat no-89230). not Working
Instrument Laboratory Hollow Cathode Lamp - Element: Maganese, Mn (Cat no-89231). Working
Philips Data Coded Hollow Cathode Lamp - Element: Sn (PN-9423 390 30501) SN - 37957. Working
Philips Data Coded Hollow Cathode Lamp - Element: Ca-Mg (PN-9423 393 31011) SN - 38083. Not tested
Philips Data Coded Hollow Cathode Lamp - Element: Hg (PN-9423 390 30801) SN - 37374. Working
Philips Data Coded Hollow Cathode Lamp - Element: Na (PN-9423 390 30111) SN - 28829. Working
Philips Data Coded Hollow Cathode Lamp - Element: Pb (PN-9423 390 30821) SN - 37759. Working
Philips Data Coded Hollow Cathode Lamp - Element: Cd (PN-9423 390 30481) SN - 37280. Working
Philips Data Coded Hollow Cathode Lamp - Element: D2 (PN-9423 390 30011) SN - 35732. not tested
Activon Hollow Cathode Lamp - Element: Calcium, Ca (SN-27775). not Working
Activon Hollow Cathode Lamp - Element: Molybdenum, Mo (SN-6603). Working
Activon Hollow Cathode Lamp - Element: Titanium, Ti (SN-5998). not tested
Cathodeon Hollow Cathode Lamp - Element: Cr (PN-3UNX/Cr) SN - 39998. Working
Cathodeon Hollow Cathode Lamp - Element: Ca (PN-3UNX/Ca) SN - 70591. Working
Cathodeon Hollow Cathode Lamp - Element: Fe (PN-3QNY/Fe) SN - 40895. Working
SIP Analytical Hollow Cathode Lamp - Element: Cd (Cat no-FL2176) Lamp no.20065 NOT WORKING
SIP Analytical Hollow Cathode Lamp - Element: Pb (Cat no-FL2172) Lamp no.20008 Working
SIP Analytical Hollow Cathode Lamp - Element: Ni (Cat no-FL2155) Lamp no.20081. Working
SIP Analytical Hollow Cathode Lamp - Element: H2 (Cat no-FL2159) Lamp no.20098. not tested
S&J Juniper Hollow Cathode Lamp - Element: Magnesium, Mg (Cat no-4132) SN-517009. Working
S&J Juniper Hollow Cathode Lamp - Element: Boron, B (SN-88541). Working
S&J Juniper Hollow Cathode Lamp - Element: Cadium, Cd (Cat no-4108) SN-514357. Working
S&J Juniper Hollow Cathode Lamp - Element: Lead, Pb (Cat no-4129V) SN-2936V. Working
S&J Juniper Hollow Cathode Lamp - Element: Aluminium (SN-88765). Working
S&J Juniper Hollow Cathode Lamp - Element: Copper, Cu (Cat no-4114V) SN-3325. Working
S&J Juniper Hollow Cathode Lamp - Element: Cu/Zn (Cat no-4289V) SN-3144V. Working
S&J Juniper Hollow Cathode Lamp - Element: Molybdenum, Mo (Cat no-4135) SN-513155. Working
S&J Juniper Hollow Cathode Lamp - Element: Molybdenum, Mo (SN-88612). Working

£ 220.00 (ex. VAT) 1 in stock
Sciex Photospray Assy no. 028825 for Mass Spectrometer Lab
ITEM-28182
Sciex Photospray Assy no. 028825 for Mass Spectrometer
This was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition but has not been tested.
Sciex Photospray
Assy no. 028825
SN - 481020509
Connected to Sciex Assy no. 029030
SN - 014020509

£ 210.00 (ex. VAT) 1 in stock
Sciex Heated Nebulizer Assy no. 019295 Mass Spectrometer Part Lab
ITEM-28181
Sciex Heated Nebulizer Assy no. 019295
This was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition with marks from use but has not been tested.

£ 205.00 (ex. VAT) 1 in stock
Sciex Ion Sprayer Assy no. 017614 for Mass Spectrometer
ITEM-28186
Sciex Ion Sprayer Assy no. 017614
This was removed from a university lab where it was surplus to requirements.
Sciex Ion Sprayer
Assy no. 017614
SN - 358001909
The item is in a good, used cosmetic condition but is untested.

£ 205.00 (ex. VAT) 1 in stock
Sciex Ion Sprayer Assy no. 017614 for Mass Spectrometer Lab
ITEM-28185
Sciex Ion Sprayer Assy no. 017614
This was removed from a university lab where it was surplus to requirements.
Sciex Ion Sprayer
Assy no. 017614
SN - 606030226
The item is in a good, used cosmetic condition but is untested.

£ 200.00 (ex. VAT) 1 in stock
Malvern Instruments Photon Correlation Spectrometer PCS100M
ITEM-25581
This Malvern Instruments Photon Correlation Spectrometer PCS100M was removed from a university lab where it was surplus to requirements.
We were unable to test this unit but is in reasonably good cosmetic condition with marks from use.
Helium-Neon/20mW CLASS 111b Laser Product
Manufactured April 1994
Model No. PCS100M

£ 135.00 (ex. VAT) 1 in stock
LDC Analytical 3200 SpectroMonitor Variable Wavelength Detector Lab
ITEM-24202
This LDC Analytical SpectroMonitor 3200 Variable Wavelength Detector was removed from a university lab where it was surplus to requirements.
The unit powers up and is in reasonable cosmetic condition but it has some marks and stains. It has not been tested further at our facility.

£ POA 1 in stock
Thermo Elemental Model Solaar S2 AA Series Spectrometer
ITEM-47049
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Thermo Elemental Solaar S2 AA Series Spectrometer
ITEM-47048
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Thermo Elemental Model Type Solaar S2 AA Series Spectrometer
ITEM-47047
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
HP 8590A Spectrum Analyzer Lab
ITEM-46424
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Thermo Scientific VP100 Vapour System Lab
ITEM-44622
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Fujifilm Phosphorus Imager FLA5000 With Computer And Plates Lab
ITEM-46205
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Micromass Platform LC Single Quadrupole Mass Spectrometer Lab
ITEM-42167
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Varian 640-IR FT-IR Spectrometer Lab
ITEM-41919
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Perkin Elmer Lambda 35 UV/Vis Spectrophotometer Lab
ITEM-46253
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Gilden Photonics fluoroSENS Fluorimeter w/ Sens-J1 Microplate Reader Lab
ITEM-46260
This item is new in stock. Please enquire for further details.
Items 151 to 200 of 201