Explore our Workshop category for a range of spare parts, repair items, and budget-friendly used equipment. Here, you'll find pre-owned items from various categories that may need repair or servicing, all offered at highly accessible prices.


Perfect for those looking for cost-effective solutions, each item has undergone a basic inspection. Please note that some products may require further servicing or repair to be fully functional for research, industrial, or laboratory applications.

Items 51 to 100 of 285

Image of Sanyo CO2 Incubator Model MCO-18AIC Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Sanyo CO2 Incubator Model MCO-18AIC Lab

ITEM-37237

Sanyo CO2 Incubator Model MCO-18AIC


This item was removed from a university laboratory where it was surplus to requirements.


The incubator powers on and is in a reasonable, used cosmetic condition.


However, it displays an error code: E12: Main heater is abnormal.


According to the previous client, the unit was not in working order prior to removal.


Due to the statement above, this item is listed as Spares/Repair.

Image of Leec P3 laboratory Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Leec P3 laboratory Incubator Lab Spares/Repairs

ITEM-39815

Leec P3 laboratory Incubator


This was removed from an industry lab where it was surplus to requirements.


The unit powers up but has issues with temperature regulation. We think the cause of this is a fan fault. (Digital thermometer not included).


It is sold for spares/repairs

Image of Heraeus Megafuge 1.0R Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Heraeus Megafuge 1.0R Centrifuge Lab Spares/Repairs

ITEM-44630

Heraeus Megafuge 1.0R Centrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in fair cosmetic condition and powers on. However, a lid sensor error prevents operation.


Therefore, it is listed as Spares/Repair.


Also includes:


1 x Heraeus Sepatech Megafuge Centrifuge Rotor 6000 RPM Cat 3360

Image of Carbolite Laboratory Incubator PIF120 Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Carbolite Laboratory Incubator PIF120 Lab

ITEM-37440

Carbolite Incubator PIF120


This was removed from a university where it was surplus to requirements.


It is in reasonably good cosmetic condition.


The glass door is detached from the unit, as shown in the pictures. The adhesive has come loose on the top and bottom hinges, therefore it is sold as Spares or Repairs

Image of Sanyo CO2 Incubator Model-MCO 20AIC Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Sanyo CO2 Incubator Model-MCO 20AIC Lab Spares/Repairs

ITEM-37261

Sanyo CO2 Incubator Model MCO-20AIC


This item was removed from a university where it was surplus to requirements.


It powers up but is reported to have a faulty CO2 sensor, displaying an E11 error, and is therefore listed as Spares/Repair.


No further testing was conducted.


The unit is in good cosmetic condition both internally and externally.

Image of Beckman Coulter Allegra 64R Refrigerated Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Beckman Coulter Allegra 64R Refrigerated Centrifuge Lab Spares/Repairs

ITEM-39218

Beckman Coulter Allegra 64R Refrigerated Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up, but the display reads the following error:


Error98: "The Error 98 indicates an invalid rotor ID. This can be caused by a malfunctioning rotor sensor, damaged rotor magnets, or bad signal read by the Rotor ID sensor due to oxide dust on the rotor's magnets."


It is in reasonably good cosmetic condition, with marks from use.


It is listed as Spares/Repairs.


Includes the following:


C0650 Fixed-Angle Conical Tube Rotor, Aluminum

Tube Volumes: 50 mL

Image of New Brunswick Scientific Controlled Environment Incubator Shaker G-25 Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

New Brunswick Scientific Controlled Environment Incubator Shaker G-25 Lab Faulty

ITEM-41336

New Brunswick Scientific Controlled Environment Incubator Shaker G-25 Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, although it is not fully operable due to the following issues:


  • Does not drop below 20ºc.
  • When you set the desired temperature, it continues to exceed that level.
  • Does not function past 300RPM.

Therefore, it is listed as Spares/Repair.

Image of Thermo Scientific Medifuge Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Thermo Scientific Medifuge Centrifuge Lab Spares/Repairs

ITEM-41374

Thermo Scientific Medifuge Centrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition but would not stay powered up in testing.


Therefore, it is listed as Spares/Repair.


Image of Walker Safety Cabinets Generation 3 Class 2 Recirculating 1500mm Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Walker Safety Cabinets Generation 3 Class 2 Recirculating 1500mm Spares/Repairs

ITEM-41592

Walker safety Cabinets Generation 3 Class 2 recirculating 1500mm


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition, but due to not including the required key to operate, we are unable to test its working condition, and therefore it is listed as Spares/Repair.

Image of Heraeus Hera Cell 150 Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Heraeus Hera Cell 150 Incubator Lab Spares/Repairs

ITEM-45432

Heraeus Hera Cell 150 Incubator Lab


This item was removed from a university lab where it was surplus to requirement.


The incubator powers on but does not heat when a temperature is set.

The auto-run light flashes continuously, indicating a possible fault.


Therefore, we are unable to conduct further testing, and this item is listed as Spares/Repair.

Image of Thermo Heracell 150 Floor-Standing Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Thermo Heracell 150 Floor-Standing Incubator Lab Spares/Repairs

ITEM-45374

Thermo Heracell 150 Floor-Standing Incubator Lab


This item was removed from a university laboratory where it was surplus to requirements.


The incubator has a faulty door that is coming apart, and due to this issue it has failed the Visual PAT and was not powered on.

Therefore, it is listed as Spares/Repair.


Other than the damaged door it is in reasonably good cosmetic condition.


Specifications.

  • Model: HERAcell 150
  • Serial No.: 40663132

Image of Heraeus Hera Cell 150 Lab Incubator Faulty - No CO2 Filter Port - Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Heraeus Hera Cell 150 Lab Incubator Faulty - No CO2 Filter Port - Spares/Repairs

ITEM-45452

Heraeus Hera Cell 150 Lab Incubator


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in good working order.


However, it requires a CO2 filter port and is listed as spares or repair. It was tested using a CO2 port from another unit.


It is in good cosmetic condition.

Image of Sanyo MC0-19AIC (UV) CO2 Lab Incubator Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Sanyo MC0-19AIC (UV) CO2 Lab Incubator Spares/Repair

ITEM-45443

Sanyo MC0-19AIC (UV) CO2 Lab Incubator


This item was removed from a university laboratory where it was surplus to requirements.


It is in fair cosmetic condition. The power cable has been cut, therefore, we are unable to power it on or test further.


Note: The last service on this unit failed.


Due to the issues stated above, this incubator is listed as Spares/Repair.


Model: MC0-19AIC



Image of Kendro Heraeus HERAcell 150 CO2 Incubator Spares/Repairs - No IEC Port Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Kendro Heraeus HERAcell 150 CO2 Incubator Spares/Repairs - No IEC Port Lab

ITEM-46286

Kendro Heraeus HERAcell 150 CO2 Incubator


This item was removed from a university laboratory where it was surplus to requirements.


The unit is unable to be powered on as the IEC port has been removed, by the previous owner. Therefore, it is listed as Spares/Repair.


It is in fair cosmetic condition but the door latch has been removed.


Includes a stand.


Model: HERAcell 150

Image of Sigma 4K10 Refrigerated Centrifuge w/ Sigma 1140 Rotor Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Sigma 4K10 Refrigerated Centrifuge w/ Sigma 1140 Rotor Spares/Repair Lab

ITEM-46333

Sigma 4K10 Refrigerated Centrifuge Lab


This item was removed from a university where it was surplus to requirement.


The unit powers up, however it could not be tested as it remained in stand-by and all control functions are unresponsive.


Therefore, it is listed as Spares/Repair.


Included;


Sigma 1140 Rotor - 5500RPM

Image of Eppendorf Benchtop Laboratory Centrifuge Model 5417C with 14000rpm Rotor Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Eppendorf Benchtop Laboratory Centrifuge Model 5417C with 14000rpm Rotor Lab

ITEM-19547

This Eppendorf Benchtop Laboratory Centrifuge Model 5417C with 14000rpm Rotor was removed from a university lab where it was surplus to requirements.


The unit powers up but has developed a lid fault and is sold for spares/repairs.


It is in reasonably good cosmetic condition with some marks from use. The unit has had a brand-new power switch fitted. The seal is in reasonable condition but may benefit from a replacement being fitted.


The rotor accomodates 2mL tubes.








Image of Neslab CFT-75 Coolflow Refrigerated Recirculator Chiller Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Neslab CFT-75 Coolflow Refrigerated Recirculator Chiller Lab Spares/Repairs

ITEM-41632

NesLab CFT-75 Coolflow Refridgerated Recirculator Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on. However, due to the following faults it is listed as Spares/Repair.


Faults:

  • The coupling is snapped between the motor and the pump head.
  • There is no water being recirculated.
  • Pump head appears to be seized.

Image of Syngene G:Box EF/Chemi XR5 Chemiluminescence Fluorescence Gel System Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Syngene G:Box EF/Chemi XR5 Chemiluminescence Fluorescence Gel System Lab Faulty

ITEM-31578

Syngene G:Box EF/Chemi XR5 Chemiluminescence Fluorescence Gel System Lab


This item was removed from a university lab where it was surplus to requirements.


The unit is in good used cosmetic condition. When connected, the GeneSys software reports that the camera is warmer than optimal, likely indicating a potential issue with the camera.


However, the camera remains functional, and no noticeable heat was felt upon touch. This system was testing with an in-house PC set-up with GeneSys software, this is not included in the sale.


Due to the camera error, this system is listed as Spares/Repair.


System includes:

  • 1 x Syngene GEF/Chemi XR5, equipped with:
  • Upper white light
  • TLUM mid-wave UV lamp
  • Epi long-wave UV
  • Synoptics Art 5.5/5.0MP camera

Image of Teikos TS601 PW DET PS Dishwasher Lab Spares/Repairs.

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Teikos TS601 PW DET PS Dishwasher Lab Spares/Repairs.

ITEM-41246

Teikos TS601 PW DET PS Dishwasher


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition internally, and externally.


When powered on, it tripped the power at our facility, therefore we are unable to test it, and it is listed as Spares/Repairs.

Image of Jouan CR422 CR-422 Refrigerated Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Jouan CR422 CR-422 Refrigerated Centrifuge Lab Spares/Repairs

ITEM-44391

Jouan CR 422 Refrigerated Centrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on, however, due to internal damage to the motor, we cannot conduct further testing.


Therefore, it is listed as Spares/Repair.


Also includes the following:


1 x Jouan Cr Swing Bucket Rotor 4750 Max Rpm

Image of New Brunswick U67-85 U6785 Benchtop Ultra Low Temperature Freezer Lab Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

New Brunswick U67-85 U6785 Benchtop Ultra Low Temperature Freezer Lab Faulty

ITEM-44671

New Brunswick U6785 Ultra Low-Temperature Freezer Lab


This item was removed from a university where it was surplus to requirement.


The unit powers up, however during testing it would not drop to its minimum temperature, and the compressor is heard powering on/off intermittently.


Therefore, it is listed as Spares/Repair.


It is in reasonably good cosmetic condition and is missing one of its feet.


Features:


1 x Shelf: 39 x 28 cm

Image of Varian CC2C Module Model Sentorr Vacuum Gauge Controller LabSpares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Varian CC2C Module Model Sentorr Vacuum Gauge Controller LabSpares/Repairs

ITEM-45018

Varian CC2C Module Model-Sentorr


This item was removed from a university lab where it was surplus to requirements. It is in fair cosmetic condition.


When powered on, a high-pitched sound emits from the back of the unit, and none of the front functions work, including the screen and buttons.


Therefore, it is listed as Spares/Repair.


Specifications:

  • Model: Sentorr
  • Serial No.: LID30427

Image of Binder CO2 Incubator C170 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Binder CO2 Incubator C170 Lab Spares/Repairs

ITEM-45251

Binder Incubator C170


This item was removed from a university where it was surplus to requirements.


The unit powers on and is in fair cosmetic condition, showing signs of general use.


Testing revealed a potential sensor fault and temperature regulation issue, as the temperature did not rise above 14.8°C when set to 37.0°C, and the display incorrectly indicated the door was open despite it being closed and locked.


Due to the faults listed above, this item is listed as Spares/Repair.


Specifications: Model: C170


Image of RS Biotech Galaxy R CO2 Laboratory Incubator Model 300 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

RS Biotech Galaxy R CO2 Laboratory Incubator Model 300 Lab Spares/Repairs

ITEM-45447

RS Biotech Galaxy R CO2 Laboratory Incubator Model 300 Lab Spares/Repairs


This item was removed from a university lab where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on, however, the control screen is not functional.


Therefore, further testing could not be conducted, and the item is listed as Spares/Repair.


Specifications;

  • Model: 300
  • S/N: 9691




Image of Heto CT 110 Cold Trap Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Heto CT 110 Cold Trap Lab Spares/Repairs

ITEM-37364

Heto CT 110 Cold Trap


This item was removed from a university laboratory where it was surplus to requirements.


The unit is in good cosmetic condition, but it consistently trips the electrical circuit when powered on. The fuse has been checked and is working, yet the problem persists.


Due to the electrical fault, this item is listed as spares or repairs

Image of Zeiss Axiophot Microscope w/ Axiocam Color 412-312 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Zeiss Axiophot Microscope w/ Axiocam Color 412-312 Spares/Repair Lab

ITEM-46947

Zeiss Axiophot Microscope with Axiocam – Spares or Repair


This item was removed from a university laboratory where it was surplus to requirements.


The microscope powers on and the internal bulb is functional. However, due to damage to the eyepiece mount (as shown), it is being sold as spares or repair.


No objective lenses or eyepieces are included.


Further testing has not been carried out.


Includes:

  • Zeiss Axiocam Color
  • Model: 412-312
  • Serial No.: 2 07 00

Image of Eppendorf BenchTop Centrifuge 5804 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Eppendorf BenchTop Centrifuge 5804 Spares/Repair Lab

ITEM-46917

Eppendorf BenchTop Centrifuge 5804


This item was removed from a university laboratory where it was surplus to requirements.


The unit powers on; however, it remains stuck on the "open lid" message regardless of whether the lid is open or closed. Additionally, the lid does not lock down.


Due to these issues, it is being sold as spares or repairs.


Image of Walkers Class II Digital Microbiological Safety Cabinet Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Walkers Class II Digital Microbiological Safety Cabinet Lab Spares/Repairs

ITEM-46913

Walkers Class II Digital Microbiological Safety Cabinet


This item was removed from a university laboratory where it was surplus to requirements.


It powers on and is in working condition, although it will occasionally turn on by itself. For this reason it is sold for spares/repairs.


The front panel is removable without any issues.


It is in good cosmetic condition.

Image of Thermo Electron Corporation Shandon Excelsior Tissue Processor - No Monitor S/R

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 400.00 (ex. VAT) 1 in stock

Thermo Electron Corporation Shandon Excelsior Tissue Processor - No Monitor S/R

ITEM-46742

Thermo Electron Corporation Shandon Excelsior Tissue Processor Lab


This item was removed from a university lab where it was surplus to requirement.


It is in good overall cosmetic condition and powers on, we are unable to test it further at our facility.


Please note that it does not include a monitor.


Therefore, it is listed as Spares/Repair.


Includes:

  • User Manual
  • Operation Guide
  • Keys
  • Various Waste/Feed Bottles

Image of Oriel Arc Lamp with Arc Lamp Ignitor & 300-500W Xe & Hg Power Supply Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 390.00 (ex. VAT) 1 in stock

Oriel Arc Lamp with Arc Lamp Ignitor & 300-500W Xe & Hg Power Supply Faulty

ITEM-36893

Oriel Arc Lamp with Arc Lamp Ignitor & 300-500W Xe & Hg Power Supply


Included are;


Oriel 300-500W Xe and Hg(Xe) Power Supply

Model - 68811

SN - 120


Oriel Arc Lamp

Model - 77504

SN - 118


Oriel Arc Lamp Ignitor

Model - 68705

SN - 253


All units connect together and the power supply powers on. When lamp start was pressed there was a pulsing sound and a flicker of light but nothing more.


It is sold for spares/repairs.


Image of Dionex IC25 Chromatograph Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 385.00 (ex. VAT) 1 in stock

Dionex IC25 Chromatograph Lab Spares/Repairs

ITEM-38974

This Dionex IC25 Chromatograph was removed from a university lab where it was surplus to requirements.


The unit powers up but is missing both its CPU and LAN card.


It is  sold for spares/repairs

Image of NAPCO Model 5430 CO2 Incubator Double Stack Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 380.00 (ex. VAT) 1 in stock

NAPCO Model 5430 CO2 Incubator Double Stack Lab

ITEM-38930

NAPCO Model 5430 CO2 Incubator Double Stack


These were removed from a university lab where they were surplus to requirements.


We had both units professionally serviced. The bottom unit is working but the top one is faulty. A full report is available on request.


They are sold for spares/repairs.

Image of Wheaton 753684-D 11 Deck R2P Roller Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 375.00 (ex. VAT) 1 in stock

Wheaton 753684-D 11 Deck R2P Roller Incubator Lab Spares/Repairs

ITEM-36853

Wheaton 753684-D 11 Deck R2P Roller Incubator


This was removed from a university lab where it was surplus to requirements.


The unit powers up and works at lower temperatures (Up to 68˚C), but the over-temp alarm comes on around there. The overtemp dial was set to 10 (full). The lab informed us that the fan has been removed, which might be the cause.


The roller apparatus has had its control panel removed and could not be tested.


The system is sold for spares/repairs.


11 Deck R2P Roller

Cat no. 348882-D

SN - I08 170

Dimensions - L77 W57 H184cm

11 Roller shelves - 78 x 56cm


Image of Sigma 6K15 Refrigerated Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 360.00 (ex. VAT) 1 in stock

Sigma 6K15 Refrigerated Centrifuge Lab Spares/Repairs

ITEM-39753

This Sigma 6K15 Refrigerated Centrifuge was removed from a university lab where it was surplus to requirements.


The unit powers up but shows "Error 43 (Inbalance offset error)".


It is in good cosmetic condition with minor marks.



Sigma 6K15 Refrigerated Centrifuge

Model: 6K15

Serial#: 89779

Year: 2002


Capacity max: 6x500ml


Image of Beckman L8-60MR Ultracentrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Beckman L8-60MR Ultracentrifuge Lab Spares/Repairs

ITEM-39709

Beckman L8-60MR Ultracentrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up and was tested with a Beckman 70.1 Ti rotor from another item (Not included), but would not reach over 3000rpm (Rotor max is 10000). We suspect there is a vacuum issue as the vacuum light flashed red during testing. The system also will not cool down.


It is in otherwise good cosmetic condition.


It is sold for spares/repairs.


Beckman L8-60MR Ultracentrifuge

Model: L8-60MR

Serial#: 6H816

Year: 1988


Image of Infors HT Minifors Fermentor Bioreactor Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Infors HT Minifors Fermentor Bioreactor Lab Spares/Repairs

ITEM-37033

Infors HT Minifors Fermentor Bioreactor


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we were advised by the lab that it is missing parts.


It is sold for spares/repairs.

Image of CytoFluor Series 4000 System with CytoFlour & GraphPad Prism 5 Software Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

CytoFluor Series 4000 System with CytoFlour & GraphPad Prism 5 Software Faulty

ITEM-36235

This CytoFluor Series 4000 System was removed from a university lab where it was surplus to requirements.


All elements of the system power up but the system is reporting a lamp failure in its maintainece checks. We replaced it with a different lamp, but the error still shows. The fan uses the same voltage as the lamp and is also not working, so there is an electrical fault at play here. The microplate incubator and tray eject functions are working.


It is in good cosmetic condition with marks from use.


Included are;


Applied Biosystems CytoFluor Multi-Well Plate Reader Series 4000

Model: CytoFluor

Serial#: HX1MNTC1290

Date: 2001 Sep


Optiplex 170L PC

Model: 170L

Service Tag: BJG8H1J

Express Service Code: 25120732231


HP 1902 Monitor

Model: 1902

Serial#: CNC4150RH

Date: 2004


Technika Mouse

Serial#: 0MS 001201


HP Keyboard

Serial#: KU-0316


The passwords for the PC will be supplied.

Image of Edwards FTM5 Film Thickness Monitor Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Edwards FTM5 Film Thickness Monitor Lab Spares/Repairs

ITEM-34643

Edwards FTM5 Film Thickness Monitor


This was removed from a university lab were it was surplus to requirements.


The unit did not power up in testing.


It is in good cosmetic condition with minor marks.



Image of Thermo Scientific MaxQ 6000 Refrigerated Incubator Shaker SHKE6000-8CE Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Thermo Scientific MaxQ 6000 Refrigerated Incubator Shaker SHKE6000-8CE Faulty

ITEM-19907

This Thermo Scientific MaxQ 6000 Incubator Shaker Model - 4360 was removed from a university lab where it was surplus to requirements.


The unit has a power board fault.


It is in reasonably good cosmetic condition with some marks from use. The door also does not close properly.


Internal dimensions - D52 x W55 x H67cm

1 Shelf - 52 x 54cm

Shaker Plate - 45 x 45cm


It is sold for spares or repairs due to the electrical fault.


Image of Night Owl EG&G Berthold Molecular Light Manager Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Night Owl EG&G Berthold Molecular Light Manager Lab Spares/Repairs

ITEM-30254

This Night Owl EG&G Berthold Molecular Light Manager was removed from a university lab where it was surplus to requirements.


The item powers on and is in a reasonably good used cosmetic condition but one of the connection ports on the back is damaged.


The UV Light works and white light can be seen powered on through the back.  There is a bag of loose parts inside.


Internal dimensions - D36.5 W52 H46cm


The lab said it wasn't working but didn't give any more details. We assume it is down to the damaged connection port.


It is sold for spares/repairs.




Image of Sanyo MCO-5M O2/CO2 Benchtop Laboratory Incubator Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Sanyo MCO-5M O2/CO2 Benchtop Laboratory Incubator Lab Spares/Repairs

ITEM-39068

Sanyo MCO-5M O2/CO2 Benchtop Laboratory Incubator


This item was removed from a university lab where it was surplus to requirements.


The unit powers up and is in good cosmetic condition. It was tested with a digital thermometer (not included).


The item held an accurate reading at 37ºc but when set to max (57ºc) it would not climb past 38ºc, therefore it's sold as Spares or Repairs.

Image of Radiometer Analytical Titration Manager - TIM865 Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Radiometer Analytical Titration Manager - TIM865 Spares/Repairs

ITEM-37140

Radiometer Analytical Titration Manager - TIM865


This item was removed from a university where it was surplus to requirements.


It is in good cosmetic condition and powers up, although the display screen is damaged, therefore, this item is listed as Spares or Repairs.


Also includes;


1x Radiometer Analytical Temperature Sensor: - opened box

Type, T201

Part no. E51M001


1x Radiometer Analytical Electrode Adjustable Stand:- Sealed box

Type, E190

Part no. 809-206


1x B525 Burette stand: -boxed

Part no X51T027

25ml


3x B550 Burette stand: -2x boxed 1x unboxed

Part no X51T028

50ml


1xCable Connection kit Burette stand: -boxed

Part no X91T034

10ml


1x Cell Accessories Kit for Titration Workstation: -boxed

Part no X91T035


1x Cable Connection Kit: -boxed

Part no X91T073


2x Burette B5xx Accessories Titration Workstation: -boxed

Part no X91T036


3x Line Cord:

Part no. A95S002 -Sealed bag

115V (US)


2x Line Cord:

Part no. A95S001 -Sealed bag

230V (Euro)


1x C501X-Serial Cable: - Sealed bag

Part no. A95X501


1xTitration Vessel : -Sealed bag

Part no. X91T056

PP.22-45ml Set of 10pcs


1xTitration Vessel : -Sealed bag

Part no. X91T055 

PP.40-100ml Set of 10pcs


1x 1xTitration Vessel : - Opened bag

PP.40-100ml Set of 10pcs (only 4pcs in bag)

Image of MSE Harrier 18/80 Refrigerated Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

MSE Harrier 18/80 Refrigerated Centrifuge Lab Spares/Repairs

ITEM-31976

MSE Harrier 18/80 Refrigerated Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit doesn't run above 2000rpm without the alarm going off.


It is sold for spares/repairs.


MSE Rotor 43124.141

Max rpm 6000

SN - H01010 2


4 x Buckets

2 x Yellow Adaptors, holds 1 x 50ml tube

2 x Green Adaptors, holds 7 x 15ml tubes


Image of Hoshizaki Laboratory Ice Maker Flaker Machine  Model - FM-120DE Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Hoshizaki Laboratory Ice Maker Flaker Machine Model - FM-120DE Faulty

ITEM-35970

Hoshizaki Laboratory Ice Maker Flaker Machine Model - FM-120DE


This was removed from a university lab where it was surplus to requirements.


The item powers up and is in reasonably good cosmetic condition.


When powered up the item generates ice but it leaks through a crack in the outlet, therefor sold as Spares/Repairs.

Image of Sorvall OTD-COMBI Ultracentrifuge w/ Sorvall T-865.1 Rotor Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Sorvall OTD-COMBI Ultracentrifuge w/ Sorvall T-865.1 Rotor Spares/Repair Lab

ITEM-41834

Sorvall OTD-COMBI Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on. However, the door unlock switch is non-functional, therefore, preventing the unit's ability to lock or open the door.


We were able to open it manually, but the automatic door open function is faulty.


Therefore, it is listed as Spares/Repair.


Also includes the following:


Dupont Instruments Sorvall T-865.1 Rotor.

Serial No: 9330329.


8 Hole rotor.

Tube dimensions: 1.5cm x 8cm.



Image of Büchi B-400 Sample Mixer Homogenizer Grinder Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Büchi B-400 Sample Mixer Homogenizer Grinder Spares/Repair Lab

ITEM-46283

Büchi B-400 Sample Mixer Homogenizer Grinder Lab


This item was removed from a university lab where it was surplus to requirement.


It is in poor cosmetic condition and does not power on, therefore, it is listed as Spares/Repair.

Image of Sigma 1-15K Refrigerated Benchtop Centrifuge w/ 12132 Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 350.00 (ex. VAT) 1 in stock

Sigma 1-15K Refrigerated Benchtop Centrifuge w/ 12132 Spares/Repair Lab

ITEM-42476

Sigma 1-15K Refrigerated Benchtop Centrifuge w/ 12132 Rotor


This item was removed from a university where it was surplus to requirement.


It powers on and is in good condition. While settings for speed, time, and temperature are adjustable, the centrifuge fails to start.


Therefore, it is listed as Spares/Repair.

Image of Fisher Scientific Isotemp 3016S Recirculating Water Bath Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 320.00 (ex. VAT) 1 in stock

Fisher Scientific Isotemp 3016S Recirculating Water Bath Faulty

ITEM-42308

Fisher Scientific Isotemp 3016S Recirculating Water Chiller / Heater


This item was removed from a university laboratory where it was surplus to requirements.


It is in very good cosmetic condition. However, one LED bar on the display screen is not illuminating, which may lead to inaccurate temperature readings during operation. No additional testing was conducted.


Therefore, it is listed as Spares/Repair.


Specifications:

  • Model: Isotemp 3016S
  • Serial No.: 110179037

Image of Fisher Scientific Isotemp 3016S Recirculating Water Bath Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 310.00 (ex. VAT) 1 in stock

Fisher Scientific Isotemp 3016S Recirculating Water Bath Spares/Repairs

ITEM-42307

Fisher Scientific Isotemp 3016S Recirculating Water Chiller / Heater


This item was removed from a university laboratory where it was surplus to requirements.


It is in very good cosmetic condition. However, one LED bar on the display screen is not illuminating, which may lead to inaccurate temperature readings during operation.


No additional testing was conducted.


Specifications:

  • Model: Isotemp 3016S
  • Serial No.: 110179037

Image of Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 310.00 (ex. VAT) 1 in stock

Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge Lab Spares/Repairs

ITEM-36102

Thermo Scientific Heraeus Megafuge 40R Laboratory Centrifuge


This was removed from a university lab where it was surplus to requirements.


The centrifuge has a faulty main board, but the following parts will be useful for spares.


Motor

Display

Compressor

Lid latches


The unit is in good cosmetic condition with marks from use.


There is no rotor


It is sold for spares/repairs.

Items 51 to 100 of 285

Filters

Price (£)

to

Condition