Workshop
Items 151 to 200 of 285

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 270.00 (ex. VAT) 1 in stock
WILD HEERBRUGG M20 Microscope & PSU (No Lamp)
ITEM-38490
WILD HEERBRUGG M20 Phase Contrast Microscope
This was removed from a university lab where it was surplus to requirements.
The PSU powers up, but as the lamp is missing, the microscope is untested.
It is in good cosmetic condition with minor marks.
PSU
SWIFT Supply Unit 463 6v A.C. 20w
Comes with 4 Objectives :
1 X Nikon - 10/0.25
1 X WILD HEERBRUGG PL Fluotar 40x/0.65
1 X WILD HEERBRUGG wild pl fluotar HI 100/1.30
1 X WILD HEERBRUGG 10/0.25
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 265.00 (ex. VAT) 1 in stock
Dionex EG40 Eluent Generator Lab Spares/Repairs
ITEM-38967
This Dionex EG40 Eluent Generator was removed from a university lab where it was surplus to requirements.
The unit powers up and passed self tests, but the fan doesn't work.
It is in good cosmetic condition with minor marks.
it is sold for spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 260.00 (ex. VAT) 1 in stock
Seta Stanhope-Seta Herschel Emulsifier x 3 Model 96700-0 V Lab Spares/Repairs
ITEM-31749
Seta Stanhope-Seta Herschel Emulsifier x 3 Model 96700-0 V
This was removed from a university lab where it was surplus to requirements.
The unit is fully functional but trips the RCD switch when powered up sometimes. We attempted to replace the switch, but it appears to be a board module causing the fault.
It is in reasonable cosmetic condition with minor marks.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 260.00 (ex. VAT) 1 in stock
Millipore Corporation XX6700P20 20L Dispensing Pressure Vessel Lab
ITEM-30531
Millipore Corporation XX6700P20 20L Dispensing Pressure Vessel
This was removed from a university lab where it was surplus to requirements.
Cat no. XX6700P20
Capacity - 20L
100 PSI MAX
SN - 97197-301
The item is in a reasonable, used cosmetic condition but has not been tested.
The date of manufacture is unconfirmed. After 20 years, the pressure vessel requires replacement, and as we are unable to confirm this, it is sold for spares/repairs only.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 260.00 (ex. VAT) 1 in stock
EC Apparatus Modulyo Laboratory Freeze Dryer Lab Spares/Repairs
ITEM-25061
This EC Apparatus Modulyo Laboratory Freeze Dryer was removed from a university lab where it was surplus to requirements.
The unit powers on but is not working. It did not cool below room temperature. The compressor sounds like it is running but is not working.
It is in reasonably good cosmetic condition but there is some surface rust at the bottom of the chamber from general use. There is a missing foot on the front LHS of the unit.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 260.00 (ex. VAT) 1 in stock
Biochrom Libra S6 Spectrophotometer Lab
ITEM-41396
Biochrom Libra S6 Spectrophotometer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
The item failed 'wavelength calibration' on the self-diagnostics test.
Includes 9V DVC Power Cable.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 260.00 (ex. VAT) 1 in stock
LEEC Incubator Type PC-2 Lab Spares/Repairs
ITEM-35606
This LEEC Incubator Type PC 2 was removed from a university lab where it was surplus to requirements.
The unit powers up, but the temperature did not change in the time it was run.
It is in reasonable cosmetic conditon with minor marks.
It is sold for spare/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 260.00 (ex. VAT) 1 in stock
Labplant Refrigerated Recirculator Model - RC-100 Lab
ITEM-26224
This Labplant Refrigerated Recirculator Model - RC-100 was removed from a university lab where it was surplus to requirements.
The unit powers up but was not tested further at our facility. The university lab told us that the pump works but the chiller does not.
It is in good cosmetic condition with some marks from use.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 255.00 (ex. VAT) 1 in stock
Beckman Coulter LS230 Particle Size Analyser w/ Fluid Module - Spares / Repairs
ITEM-25210
Beckman Coulter LS230 Particle Size Analyser w/ Variable Speed Fluid Module
This was removed from a university lab as it was reported to be faulty. We were not informed what the fault is.
Included in the system are;
1x LS230 Particle Size Analyser
The unit is in good condition but there seem to be quite a few parts taken from the unit. It powers up but was not tested further.
1x LS Variable Speed Fluid Module Plus
The unit is in good cosmetic condition. It powers up but was not tested further.
There is a manual included.
It is sold for spares/repairs due to the suggested fault.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 255.00 (ex. VAT) 1 in stock
Biochrom Libra Model S6 Spectrophotometer Lab Spares
ITEM-28168
Biochrom Libra S6 Spectrophotometer
The item powers on and has been tested, it works but failed calibration.
Requires 9vdc power supply, tested with our own.
The item is in a reasonable, used cosmetic condition apart from some tape residue that won't come off.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 255.00 (ex. VAT) 1 in stock
MSE Mistral 3000 Benchtop Centrifuge Lab Spares/Repairs
ITEM-35763
MSE Mistral 3000 Benchtop Centrifuge
This was removed from a university lab where it was surplus to requirements.
The unit did not power up in testing, but we were able to open the lid to confirm there is no rotor inside.
It is in reasonably good cosmetic condition with marks from use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair
ITEM-36992
New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair
This was removed from a university lab where it was surplus to requirements.
The unit powers but requires a replacement compressor and recharge as well as a new drive belt.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
ProteinSimple FluorChem E Imaging System Lab Spares/Repairs
ITEM-36928
This Protein Simple FluorChem E Imaging System was removed from a university lab where it was surplus to requirements.
The unit powers up and the camera is working, but the lab confirmed the system has a hard disk error.
We found it to have issues with he white light LED, the focus drive and the stepper motor.
It is in otherwise good cosmetic condition with minor marks.
Sold for spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Huber Unichiller UC015 Recirculating Chiller Lab Spares/Repairs
ITEM-36674
This Huber Unichiller UC015 was removed from a university lab where it was surplus to requirements.
The item powers on and is in reasonably good used cosmetic condition.
We were unable to test as there is a hole in the front tank. The alarm sounds from the low water level, but the hole doesn't allow it to be filled.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Nikon Apophot Table Microscope with 4 x Objectives Lab Spares/Repairs
ITEM-35332
Nikon Apophot Table Microscope with 4 x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit powers up and the halogen bulb is working, but there appears to be no power going to the second lamp. Without the second lamp working we were unable to see a clear image during testing. We feel it may need a degree of refurbishment to get it working again so it is sold for spares or repairs.
It is in good cosmetic condition but has marks from age and use.
Item supplied with:
1 x Nikon Apophot Microscope.
1 x Nikon Transformer.
1 x Nikon 78567 DLL 40 0.65 0.17 Objective.
1 x Nikon 42502 10 Plan 0.25 Objective.
1 x Nikon 70693 DLL 40 0.65 0.17 Objective.
1 x Nikon 33525 DL 10 0.30 Objective.
2 x Nikon control panel.
2 x Nikon AFM.
2 x Nikon Eyepiece HKW 10x.
2 x Nikon Eyepiece HK 5x.
2 x Microtec WF 10x.
3 x Nikon M-35 S Camera.
Item powered on:
Nikon Transformer powered on.
Halogen bulb working.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Pyrosequencing PSQ96 Pyrosequencer Lab Spares/Repairs
ITEM-31384
This Pyrosequencing PSQ96 Pyrosequencer was removed from a university lab where it was surplus to requirements.
The unit does not power up and fails a visual PAT test due to exposed wires at the back.
It is in reasonably good cosmetic condition with minor marks from use.
Block - 96 x 0.2ml

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Savant SPD121P-230 Speed Vac Centrifugal Vacuum Concentrator Lab Spares/Repairs
ITEM-30217
Savant SPD121P-230 Speed Vac Centrifugal Vacuum Concentrator
This was removed from a university lab where it was surplus to requirements.
The unit is operational and powers on successfully. However, as the lid does not lock properly, it is listed as Spares or Repair.
It is in good cosmetic condition with minor marks.
Rotor holds 40 x 2ml tubes

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Varian Turbo - V 250 Macro Torr 9699008 Turbomolecular Pump Spares/Repair Lab
ITEM-27971
Varian Turbo - V 250 Macro Torr Pump Turbomolecular Pump
This item was removed from a university laboratory where it was surplus to requirements.
While the pump is in good cosmetic condition, an inspection revealed a noticeable rattling sound when turning the turbine.
This sound indicates there may be an obstruction or damage, preventing the pump from operating at the necessary high RPMs for proper function.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Corbett Research Rotor-Gene RG-3000 Lab Spares/Repairs
ITEM-25811
This was removed from a university lab where it was surplus to requirements.
The unit powers up but when we tried to connect it to a PC with software we had some issues. (Software not included).
We installed software on a test PC and it did seem to connect to the RG3000, but it is stating that there is a Fatal Hardware Malfunction. The machine can't be used until the distributor has service it. After starting it again we got another error: Thermistor is Open.
We have removed the casing to check inside the unit and cannot find any obvious issues.
There is an LCD panel inside that is showing 'TEMP OVER 140/127.5/2.1/152.0'. This displays as soon as the unit is switched on, so it looks like there is some sort of temperature error happening. There are 4 x PTC EPCOS C810 Thermistors in the power supply section of the unit. It's possible that there is a fault with at least one of those.
It is in otherwise reasonable cosmetic condition with marks from use, but is sold for spares/repairs
The item holds up to 72 x 0.1ml strip tubes.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Beckman Coulter LS200 Particle Size Analyser Spares Repairs - Lab
ITEM-25211
Beckman Coulter LS200 Particle Size Analyser w/ Variable Speed Fluid Module
This was removed from a university lab as they reported it had developed a fault. We do not know what the fault is.
Included in the system are;
1x 1x LS200 Particle Size Analyser
The unit is in reasonable condition but there seem to be quite a few parts taken from the unit. We did not power on the unit due to safety precautions.
1x LS Variable Speed Fluid Module Plus
The unit is in good cosmetic condition. We did not power it up as it requires power to the LS200 but it was reported faulty by the lab.
Unit is sold as spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Bruker ImagePrep Sample Preparation Matrix Deposition Device Lab Faulty
ITEM-19309
This Bruker ImagePrep Sample Preparation Matrix Deposition Device was removed from a university lab where it was surplus to requirements.
The unit is in good used cosmetic condition but it does have some marks and signs of use.
It powers up fine and we have been through a few of the menus and they all work as they should. We were unable to test further as it requires a gas supply etc. We were told by the lab manager that it needed additional parts to make it operational, though we are unsure what exactly the fault is.
It comes with a touch pen.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Leica AODS 20200-8 Laser Modulator Lab Spares/Repairs
ITEM-44495
Leica AODS 20200-8 Laser Modulator Aods Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on. We are unable to test it further at our facility; therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Agilent Technologies DNA Microarray Scanner G2505 B Lab Spares/Repairs
ITEM-46338
Agilent Technologies DNA Microarray Scanner G2505 B Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
According to the previous owner - The scanner powers up and initialises but the lasers don’t seem to be warming up. I’m not sure why that is, whether there’s a communication issue with the computer or the laser power is low
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Elga PureLab Option with Elga USF 75L Model OR007BPM1 Reservoir Lab
ITEM-41583
Elga PureLab Option with Elga USF 75L Model-OR007BPM1 Reservoir
This system was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers on. However, the screen is faulty, as it lights up but remains blank. Additionally, the reservoir is a visual PAT fail due to exposed wires in multiple areas.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Uvitec UVIDOC Gel Imaging Documentation System Lab
ITEM-45364
Uvitec UVIDOC Gel Imaging Documentation System
This item was removed from a university laboratory where it was surplus to requirements.
The system powers on, but the screen remains on the loading screen and does not proceed further. The locking mechanism is faulty.
The item is in good cosmetic condition, with the internal light functioning, although it does not include a transilluminator.
Due to the faults stated above, this item is listed as Spares/Repair.
Included Components:
- Camera: TV Zoom Lens 1/2" C 8-48mm F1.0 (Serial No.: 07 20728, not tested)
Serial No.: 07 20588

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Related Fluid Power Ltd Pump Type - MM71B4 with Atos Valve T-50-13-L Lab
ITEM-36864
Related Fluid Power Ltd Pump Type - MM71B4 with Atos Valve T-50-13-L Lab
This item was removed from a university where it was surplus to requirement.
Both the pump and Atos Valve are in good cosmetic condition.
We are unable to test the pump as it requires rewiring, therefore this item is listed as Spares/Repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
MSE Falcon 6/300 Centrifuge w/ MSE Swing Out Rotor Lab
ITEM-36611
MSE Falcon 6/300 Centrifuge
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, although due to a broken cooling fan, we are unable to test this item beyond 2500rpm.
Therefore, this item is sold as Spares/Repair.
Also includes the following:
1 x MSE Swing Out Rotor (Max RPM 3660)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Oxford 600 Series CryoSystems Cryostream Controller Lab Spares/Repair
ITEM-41689
Oxford 600 Series CryoSystems Cryostream Controller
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, the display screen is faulty.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Biochrom Libra S6 Spectrophotometer Lab Spares/Repairs
ITEM-28169
This was removed from a university lab where it was surplus to requirements.
The unit powers up but failed calibration
It is sold for spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Stuart SI50 Shaking Orbital Incubator Lab Spares/Repairs
ITEM-45366
Stuart SI50 Shaking Orbital Incubator
This item was removed from a university laboratory where it was surplus to requirements.
The incubator powers on momentarily; however, the mains button for the shaker is stuck, causing the unit to power on and off intermittently.
Additionally, one hinge on the door is broken. The display screen is functional, and the unit is in relatively good cosmetic condition.
Due to its temperamental functionality, this item is listed as Spares/Repair.
Specifications.
- Model: S150
- Serial No.: 5413

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Kendro Heraeus HERAcell 150 CO2 Incubator Lab Spares/Repairs
ITEM-46285
Kendro Heraeus HERAcell 150 CO2 Incubator Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however it did not rise in temperature during testing. The former owner reported a motherboard fault.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Syngene U:Genius 3 Gel Imaging System Lab Spares/Repairs
ITEM-45219
Syngene U:Genius 3 Gel Imaging System Lab
This item was removed from a university lab where it was surplus to requirements.
The previous client indicated that it was in working order prior to removal; however, it does not include the required software.
The system powers on with partial functionality: the UV light does not work, but the normal white light operates as expected. The touch screen is responsive but requires calibration. The internal light box could not be powered on.
Due to the fault listed above this system is listed as Spares/Repair.
It is in good cosmetic condition.
Version: 3.1.1.0
Serial No.: UG3/1088
Includes:
- 1 x Keyboard
- 1 x Mouse

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Hund Wetzlar Wilovert Microscope with 3 x Objectives Lab Spares/Repairs
ITEM-41252
Hund Wetzlar Wilovert Microscope with 3 x Objectives
This was removed from a university lab where it was surplus to requirements.
The unit does not power up.
3 x objectives are included but all the details are scratched off.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Mettler Toldeo AB54-S Analytical Balance 0.1 Lab Spares/Repairs
ITEM-44384
Mettler Toldeo AB54-S Analytical Balance 0.1 Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition but does not power on, therefore it is listed as Spares/Repair.
Includes all panels, no major damage sustained.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Merck Hitachi L-7480 Fluorescence Detector Lab Spares/Repairs
ITEM-44420
Merck Hitachi L-7480 Fluorescence Detector
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in reasonably good cosmetic condition externally. However, upon testing, the unit tripped the circuit multiple times.
An internal battery, which was mounted in the top of the unit, has leaked and caused significant damage to the circuit boards beneath it, explaining the electrical issues. The battery has been removed, but the damage to the components is considerable.
Therefore, it is listed as Spares/Repair.
Specifications;
- Model: L-7480
- Part No.: 810-0482
- Serial No.: 0601-074

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
UVP UV2 Sterilizing PCR Workstation Lab Spares/Repairs
ITEM-46146
UVP UV2 Sterilizing PCR Workstation
This item was removed from a university laboratory where it was surplus to requirements.
It powers on but appears to have a fault, with a possible issue affecting the fan.
The plexiglass shows significant wear from extensive use, resulting in poor cosmetic condition, though the rest of the unit remains in fair cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Sigma 3K15 Benchtop Centrifuge Spares/Repair Lab
ITEM-46334
Sigma 3K15 Benchtop Centrifuge
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonable cosmetic condition but is listed as spares or repairs due to several operational issues.
The control buttons are unreliable, and the display screen is malfunctioning, frequently switching between temperature and time settings without stabilizing.
Although the display is set for the 5500 rotor, which is installed, it cannot start due to error code 99. This error indicates that the rotor selected on the centrifuge does not match the one installed

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Jenway 7300 Spectrophotometer - Spares/Repair Lab
ITEM-46196
Jenway 7300 Spectrophotometer - Spares/Repair
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonably good cosmetic condition, however, the hinges for the lid mechanism are broken, and it does not include the required power supply.
Due to the missing power supply and damaged hinges, we are unable to power it on or test it further.
And it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Solent Scientific Microscope Incubation Chamber for Zeiss Axio Spare/Repair Lab
ITEM-42486
Solent Scientific Microscope Incubation Chamber for Zeiss LSM 780 Axio Observer
This system was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition, with the chamber powering on and heating up. We were unable to test the system further.
While the unit is in good cosmetic condition, it has several missing components and operational limitations. Key missing parts include the power distribution unit, AC adapter, and essential cables, which restrict functional testing. Additionally, the incubator case lacks some smaller components and a temperature probe.
Therefore, it is listed as Spares/Repair.
It comprises the following:
- Solent Scientific dark chamber for Zeis 780 Axio Observer Microscope
Serial No. not present
- Solent Scientific incubator temperature controller
Serial No. 9962
- Solent Scientific heater unit
Serial No. 6681
- Solent Scientific CO2 enrichment controller
Serial No. 9963
Also Includes:
- 1 x CO2 tubing caddy
- 3 x small plastic casing panels
- 1 x 2m length of tubing
- 1 x packet of thumb screws and small fittings
- 1 x data cable

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Edwards Turbo Molecular Pump (TMP) Model nEXT 400IID UHV-160W
ITEM-42496
Edwards Turbo Molecular Pump Model nEXT 400IID UHV-160W
This item was removed from a university where it was surplus to requirement.
It is in very good cosmetic condition, however, the previous owner has stated the pump is faulty, although the reason is undetermined.
Therefore, it is listed as Spares/Repair.
Includes:
- 2 x Gaskets
- 1 x Electrical Connector Block
Specifications:
- Code B83200816
- Serial No. 190134253

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Thermo Dionex Softron Nano Pump Block - Sensirion ProFlow Flow Meter 9041.0007A
ITEM-42541
Thermo Dionex Softron Pump and ProFlow Flow Meter 9041.0007A
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition. The Softron pump appears to be missing the pump heads, and it's very likely other parts may also be missing.
Therefore, it is listed as Spares/Repair
Includes:
- Thermo Dionex Softron Pump 9041.0007A 1.0 (missing pump heads)
- Thermo Scientific Sensirion Flowmeter
- Two LG64-0025 meters
- Firmware version: 1.40 or later
- PCB: 9041.0012
Serial Nos.:
- 2010-00668
- 2008-00377

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Record WPE 100 Electric Work Positioner Spares/Repair
ITEM-46227
Record WPE 100 Electric Work Positioner
This item was removed from a university laboratory where it was surplus to requirements.
It powers on, but the buttons on the controller that move the tray are faulty and do not function.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
LiftSafe 60KG Electric Work Positioner Spares/Repair
ITEM-46229
LiftSafe 60KG Electric Work Positioner
This item was removed from a facility where it was surplus to requirement.
It is in fairly poor cosmetic condition and has failed a visual PAT.
Also, the power supply is not included.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
LiftSafe 60KG Electric Work Positioner Spares/Repair
ITEM-46230
LiftSafe 60KG Electric Work Positioner
This item was removed from a university laboratory where it was surplus to requirements.
The item is in poor cosmetic condition, with significant rust and stiff wheels. Additonally, it did not pass the visual PAT due to exposed wires.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Mettler Toledo AT200 Balance With LC-P45 Printer Spares/Repair Lab
ITEM-46238
Mettler Toledo AT200 Balance With LC-P45 Printer
This item was removed from a laboratory where it was surplus to requirements.
It is in poor cosmetic condition, and is not operational due to buttons that are falling off or ceased.
Therefore, it is listed as Spares/Repair.
Includes:
- Power supply

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Kinematica AG Polytron 4000 Homogenizer Spares/Repair
ITEM-46892
Kinematica AG Polytron 4000 Homogenizer
This item was removed from a university laboratory where it was surplus to requirements.
It is in reasonably good cosmetic condition and powers on, however, it does not function correctly as the screen is stuck on 'Stop'.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Sirius Analytical Instruments PCA200 Titration System Spares/Repair Lab
ITEM-26044
Sirius Analytical Instruments PCA 200 Titration System
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in reasonably good cosmetic condition, with some marks from use and damage on the top right.
It powers up but experienced issues during startup, as it seemed to get stuck in a loop, requiring a shutdown to stop the process.
Due to the fault stated above, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 250.00 (ex. VAT) 1 in stock
Hitachi Lachrom HPLC System - L-7000, L-7200, L-7100, L-7400 Lab Spares/Repairs
ITEM-30327
This Hitachi Lachrom HPLC System was removed from a university lab where it was surplus to requirements.
Included in the system are;
1x Hitachi Lachrom Sampler L-7200
Part No. 810-0202
The unit powers on and is in good cosmetic condition.
•RAM Check -OK
•Memory Check -ERROR
•Syringe Initialising -OK
Injection Valve Initialising -ERROR
We were unable to remove the errors.
2x Hitachi Lachrom L-7100:
Part No. 810-0101
Part No. 810-0102
The units both power on and are in good cosmetic condition. There are some scuffs, scratches and surface stains from general use. The LCD display was quite dimly lit. We were unable to select any options.
•Message D LINE SYSTEM IS NOT READY appears on both units
2x Hitachi Lachrom UV Detector L-7400:
Part No. 810-0402
One of them powers up, but the other trips the electrics in or testing facility.
The units are in good cosmetic condition,
There are some scuffs scratches and surface stains from general use.
2x Hitachi Lachrom L-7000: Unit No. 810-5116
One power up, and the other does not.
The units are in good cosmetic condition,
There are some scuffs scratches and surface stains from general use.
2x Hitachi Lachrom Organizers (storage compartments)
Part No. 810- 4940
Part No. 810-9900
The units are in good cosmetic condition. There are some scuffs, scratches and surface rust from general use.
Accessories:
1x FPLC Column INV-917:
Code No. 18-1147-23
The unit is in good cosmetic condition.
1x Gilson System Interface:
Model. 506C
The unit powers on and is in good cosmetic condition.
1x Anachem Power supply:
230v - 50Hz / 150mA
The unit powers on and is in good cosmetic condition.
1x Jones Chromatography Box w/ Serial cable:
Ser No. 13949
The unit and cable are in good cosmetic condition
25 Pin Male to RS232 to 25PIN Male adaptor.
The cable and adaptor are in good cosmetic condition.
3x Ethernet cables:
The units are in good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 240.00 (ex. VAT) 1 in stock
Mettler-Toledo Type KCC150 Multirange Scales Lab Spares/Repairs
ITEM-36448
This Mettler-Toledo Type KCC150 Multirange Scales was removed from a university lab where it was surplus to requirements.
The unit powers up but it is completely out of calibration.
It is in reasonable cosmetic condition with minor marks.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 240.00 (ex. VAT) 1 in stock
Biochrom Type Libra S6 Lab Spectrophotometer
ITEM-41406
Biochrom Libra S6 Spectrophotometer Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
The item failed the self-diagnostics test due to 'general system failure'
Items 151 to 200 of 285