Items 1 to 20 of 38

Image of item

£ 182.25 (ex. VAT) 1 in stock

Beckman DU-640 UV-Vis Spectrophotometer Lab

ITEM-09960

This unit was removed from a lab during a clearout.


We have powered it on but not tested it further.

Image of item

£ 50.77 (ex. VAT) 1 in stock

Beckman Spectrophotometer UV Deuterium Lamp Bulb 596791

ITEM-02777

Beckman Spectrophotometer UV Deuterium Lamp Bulb 596791 

Image of item

£ 1,063.12 (ex. VAT) 1 in stock

BOMEM DA3 Series Spectrophotometer System

ITEM-08952

BOMEM DA Series Spectrophotometer System

  • From a top UK university, now surplus to requirements.
  • This system was complete and it was in use until several months ago when it was dismantled and removed from a working laboratory, however we do not have the ability to test it and to confirm the operating condition of this unit. It comes with a lot of literature, manual, diagrams, sotware and associated PC (shown in the photos).
Image of item

£ 375.00 (ex. VAT) 1 in stock

Bruker Avance DPX 250 NMR Spectrometer Control Server Lab

ITEM-13141

This system was removed from a university lab during a clearout.


Each component powers on separately - but we have not tested it further.

Image of item

£ 33.84 (ex. VAT) 1 in stock

Cecil Instruments CE 404 Colorimeter - Faulty Laboratory Equipment

ITEM-06628

Cecil Instruments CE 404 Colorimeter - Faulty Laboratory Equipment


This item has been tested and for the reasons below this item is being sold as Spares or Repair.


  • The cuvette holder and lid are missing, these will require replacing. 
  • There are already filters in place meaning you may not be able to accurately dial the wavelengths required. This may cause loss of sensitivity unless you able to rectify the filters.
  • The cuvette on the right seems to give a higher reading than the one on the left, regardless of whether it is sample or blank.

We have been unable to diagnose these faults further and we do not have the expertise to rectify them.

Image of item

£ 304.59 (ex. VAT) 1 in stock

Clare Chemical Dark Reader DR89X Transilluminator Lab

ITEM-09372

This item was removed from a lab as surplus to requirements. We have tested the unit and it appears to work expected but we havn't tested it fully with samples etc. However, the lab assured us that the unit was in full working order prior to removal. Therefore if you encounter any issues with the system we will offer you a full refund and cover return postage costs.

Image of item

£ 15.00 (ex. VAT) 1 in stock

Edwards C10512316 FLANGE NW16 70MM ST/ST Lab

ITEM-10568

This part was removed from a university store as surplus to requirements.


It is sealed in original pack.

Image of item

£ 152.30 (ex. VAT) 1 in stock

Faulty Hitachi U-1800 Spectrophotometer Lab Equipment

ITEM-05839

This Hitachi U-1800 Spectrophotometer came to us as part of a Lab clear out.  Cosmetically it is in great condition and powers up but the digital display is faint and the unit displays a 656.1nm NG error and we are unable to test further so the unit is being sold as Faulty, Spares and Repairs

Image of item

£ 406.12 (ex. VAT) 1 in stock

Hitachi U-2000 Spectrophotometer Lab Laboratory P/N 121-0003

ITEM-06649

  • From a UK University
  • When powered on, it says 'Calibrate instrument'. We have not tested the unit further.
  • Reasonably good condition 
  • 220V
  • Serial number: 121-0120
  • Part No: 0256-010
  • Model: U-2000
  • User guide included
Image of item

£ 455.62 (ex. VAT) 1 in stock

Hitachi U-2001 Spectrophotometer Lab Equipment - Faulty Keyboard

ITEM-11712

This unit was removed from a lab during a clearout.


It powers up but the keyboard is unresponsive in the menus.


Unit is therefore sold as spares / repairs.

Image of item

£ 562.50 (ex. VAT) 1 in stock

Hitachi U-3000 UV Spectrophotometer Lab

ITEM-05596

  • From UK University
  • Good condition with some minor wear
  • Powered up and the bulb is working but the unit has not been tested any further.
  • Unit has general scuff marks throughout but only cosmetic.



Image of item

£ 750.00 (ex. VAT) 1 in stock

Horiba Jobin Yvon Fluoromax-3 Spectrofluorometer System Spec Lab

ITEM-13941

This unit was removed from a lab as surplus to requirements.


Fluro-Max 3 and RM PC.


All units power up fine.


The software is on the PC for the Fluro-Max. The software registers that the Fluro-Max is connected to the PC, when all powered up.


Comes with all relevant cables etc.


Unit looks like it might be missing a dial on front of the controls - please check photos for confirmation.

Image of item

£ 364.50 (ex. VAT) 1 in stock

Instrumentation Laboratory 943 Flame Photometer IL943 Lab Equipment

ITEM-07584

This system was removed from a university lab as surplus to requirements. We were informed it is in full working order.


Please note for any UK shipping the propane canister will be removed.


For any international shipping, all internal standards and liquids will have to be removed.


Offers of collection are welcome on the unit.

Image of item

£ 150.00 (ex. VAT) 1 in stock

Jenway 6305 Spectrophotometer Lab - Spares / Repairs

ITEM-07948

This unit was removed from a lab during a clearout.


The user of this unit reported several faults as below:


The unit has displayed error messages several times. Initially, during the first time I turned it on, it displayed the message 'error 5'. After powering off and on again, the unit worked okay. This same problem has occurred probably 50% of the time I turn the device on, and on top of this there is occasions where the error message 5 displays repeatedly followed by error message 7.


Error 5 is 'Lamp Failure' The instrument is unable to detect a peak signal for wavelength calibration. Possible causes of this error are that the lamp has failed or that a sample has been left in the sample chamber during start-up.


Error 7 is 'Power on self-test error' The instrument is unable to detect the monochromator reference position sensor. Please contact Bibby Scientific service or your local distributor.


At our site we powered up the unit but did not get either error - but presumably they are intermittent.


Unit sold as spares / repairs.


Image of item

£ 338.44 (ex. VAT) 1 in stock

Kontron 440 Photodiode Array Detector HPLC

ITEM-08290

This unit was removed from a lab as surplus to requirements. It has been powered on but not tested further.

Image of item

£ 150.00 (ex. VAT) 1 in stock

Kontron Uvikon 930 UV/VIS Spectrophotometer Lab

ITEM-13139

This unit was removed from a lab during a clearout.


Unit powers on, and lights work, but unable to test further.


Display screen is bleeding, looks like you can connect a monitor, but not sure to which port as we dont have the right kind of monitor/ connector.


Image of item

£ 911.25 (ex. VAT) 1 in stock

Molecular Devices Spectra Max 340 Laboratory Microplate Spectrometer Reader Lab

ITEM-09709

This unit was removed from a lab as surplus to requirements.


The lab manager assured us it was working when last used.


At our site we have powered it on but not tested it further.

Image of item

£ 607.50 (ex. VAT) 1 in stock

Perkin Elmer 241 Lab Polarimeter

ITEM-08326

This unit was removed from a chemistry lab as surplus to requirements.


We were assured the unit is in working order, but have only tested it to power-up ourselves.

Image of item

£ 549.79 (ex. VAT) 1 in stock

Perkin Elmer Fluorescence 204 Spectrophotometer Analyser Laboratory Equipment

ITEM-06749

  • This has come to us as part of a clear out from a UK University
  • It has been pulled from a store room where they put there surplus to requirement .
  • Model - 204
  • Part No: 204-0010
  • Serial number: 4708-20
  • 115V
  • Powers up but not tested further.
Image of item

£ 792.79 (ex. VAT) 1 in stock

Perkin Elmer Lambda 25 UV/VIS Spectrometer Lab Spec

ITEM-09590

This unit was removed from a lab as surplus to requirements. We were assured it was in full working order prior to removal.

Items 1 to 20 of 38