Workshop
Items 301 to 310 of 310

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
Purite Select HP40/BP/IT Water Purification System Lab Spares/Repairs
ITEM-36189
This Purite Select HP40/BP/IT Water Purification System was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
Display screen reads:
Replace NCP Pack
The tap on the front is broken, for this reason, it is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
Skalar San Plus Digital Photometer System Type - 8503 Lab Spares/Repairs
ITEM-25527
This Skalar San Plus Digital Photometer System Type - 8503 was removed from a university lab where it was surplus to requirements.
The unit is in reasonably good cosmetic condition but does not power up.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
UVP GelDoc-It Imaging System w/ UVP FirstLight UV & HR Camera Spares/Repair Lab
ITEM-46901
UVP GelDoc-It Imaging System with HR Camera – Spares/Repair
This item was removed from a university laboratory where it was surplus to requirements.
The system is in reasonable cosmetic condition. The white light function powers on and communicates with the system, confirming power is being received. However, the integrated UVP FirstLight UV Illuminator does not power on when connected through the GelDoc-It system. Notably, the illuminator functions when plugged directly into a wall socket, indicating the issue lies in the power delivery from the main unit rather than the illuminator itself.
Due to this fault, the system is being sold as Spares/Repair.
Includes:
- GelBase User's Guide
- 2x User Manuals
- GelBase/GelBlot Pro
- Support CD
- Image Acquisition and Analysis Software CD
- UVP BioImaging Systems Gel HR Camera
- UV/White Converter Plate

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
Liebherr Mediline 1610 Fridge Spares/Repair Lab
ITEM-46384
Liebherr Mediline 1610 Fridge Spares/Repair Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition but has not been tested further due to it failing its PAT on Earth Continuity.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
New Brunswick Water Bath Shaker Model - Classic C76 Spares/Repair Lab
ITEM-46978
New Brunswick Classic C76 Water Bath Shaker
This item was removed from a university laboratory where it was surplus to requirements.
The unit powers on and holds water; however, as soon as the shaker function is activated, water begins to leak from the bottom of the unit.
The internal drain tap is also extremely stiff and difficult to operate, suggesting a possible internal blockage.
There is visible rust inside the water bath, and the item is in poor cosmetic condition overall.
Therefore, it is listed as Spares/Repair.
Model: Classic C76

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
Liebherr GP 1356 Under Counter Fridge Spares/Repair - Unresponsive Control Lab
ITEM-42725
Liebherr GP 1356 Under Counter Fridge
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, the screen is unresponsive, therefore testing could not be complete, and it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
Liebherr GGU 1500 Under Counter Fridge Spares/Repair Lab
ITEM-42726
Liebherr GGU 1500 Under Counter Fridge
This item was removed from a university laboratory where it was surplus to requirements.
The unit is in good clean condition but trips the electrical supply when powered on and has failed insulation during PAT testing. It was not possible to conduct further testing.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
Liebherr Mediline Model LKUexv 1610 Fridge Spares/Repair Lab
ITEM-46449
Liebherr Mediline Model LKUexv 1610 Fridge Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing it failed to reach it's minimum temperature.
Therefore, it is listed as Spares/Repair.
Includes 3 x shelves (60 x 60cm)

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 100.00 (ex. VAT) 1 in stock
Liebherr Mediline LKUexv 1610 Fridge Spares/Repair Lab
ITEM-46998
Liebherr Mediline LKUexv 1610 Fridge Spares/Repair Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and powers on, however during testing it failed to reach its minimum temperature of 3ºc.
Therefore, it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 75.00 (ex. VAT) 1 in stock
Thermo Scientific ES Series 151F-AEV-TS Undercounter Freezer Lab Faulty
ITEM-16727
Thermo Scientific ES Series Laboratory Refrigerator Model - 151R-AEV-TS
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and cools to the set temperature. However, the door alarm activates even when the door appears to be securely closed.
The refrigerator is in reasonably good cosmetic condition, with marks typical of previous use.
Due to the error with the alarm sounding during operation, this item is listed as Spares/Repair.
Inner dimensions:
- Height: 69 cm
- Width: 53 cm
- Depth: 48 cm
Includes:
- 2 Shelves (each 44 x 52 cm)
- 3 Baskets:
- 2 x W49.5 x L42 x D15 cm
- Bottom basket: W49.5 x L26 x D15 cm
Model: 151R-AEV-TS
Items 301 to 310 of 310