Explore our Workshop category for a range of spare parts, repair items, and budget-friendly used equipment. Here, you'll find pre-owned items from various categories that may need repair or servicing, all offered at highly accessible prices.


Perfect for those looking for cost-effective solutions, each item has undergone a basic inspection. Please note that some products may require further servicing or repair to be fully functional for research, industrial, or laboratory applications.

Items 101 to 150 of 308

Image of Limpsfield LPN3/2051 Natural Gas Burner 2051 KW/hr with Dungs Gas Valve Train

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Limpsfield LPN3/2051 Natural Gas Burner 2051 KW/hr with Dungs Gas Valve Train

ITEM-37792



Limpsfield LPN3/2051 Natural Gas Burner 2051 KW/hr (7.0MBtu/hr)


This item was removed from a university lab where it was surplus to requirements.


The burner is in good cosmetic condition. However, the burner control screen has come apart from the control panel and is possibly broken. No testing has been carried out.


Due to the inability of testing and damaged control screen, this item is listed as Spares/Repair.


Specifications:

  • Model: LPN3/2051
  • Serial No.: 01333
  • Manufactured: 11.09.15
  • Output: 2051 KW/hr (7.0 MBtu/hr)

Includes:

  • Dungs Gas Train Valve: FRS 5065 gas regulator, VPS 504 leak detector, GF 40065/3 filter
  • Autoflame Combustion Management System:
  • Part Nos.: MM10005, MM10004
  • Serial Nos.: 20368, 051771
  • TEC Fan Motor:
  • 5.5KW 415 volt
  • Type: 5.523TECAB35-IE3
  • T3A 13251-2
  • Gas Inlet Pipe: 2.5"
Image of Scotsman EF156 Easy-Fit Laboratory Ice Machine Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Scotsman EF156 Easy-Fit Laboratory Ice Machine Lab Spares/Repairs

ITEM-35867

Scotsman EF156 Easy-Fit Laboratory Ice Machine


This was removed from a university lab where it was surplus to requirements.


The unit powers up and works, but has the following issues;


Water is pooling on the housing of the gear motor. It is extremely corroded and may need replacing.  We were told that the water seal was leaking causing constant water flow to on board drain pump which is also faulty.


It is in reasonable cosmetic condition with marks from use.


Bin capacity- 60KG


Model- EF 156 Easy Fit A 230/50


Image of Sartorius Stedim BioSealer Tube Sealer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Sartorius Stedim BioSealer Tube Sealer Lab Spares/Repairs

ITEM-35787

Sartorius Stedim BioSealer Tube Sealer


This was removed from a working lab where it was surplus to requirements.


The unit powers up but does not heat.


It is sold for spares/repairs.

Image of Julabo Recirculating Chiller Model: FLW1703GB Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Julabo Recirculating Chiller Model: FLW1703GB Lab Spares/Repairs

ITEM-20313

This Julabo FL 1703 Recirculating Chiller Model: FL1703GB was removed from a university lab where it was surplus to requirements.


The item is in reasonable cosmetic condition. It has scratches and stains along its surface.


The unit powers up but requires a replacement compressor.


It is in good cosmetic condition with minor marks.


It is sold for spares/repairs.




Image of JK Lasers Class 4 MS20 Laser & Accessories Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

JK Lasers Class 4 MS20 Laser & Accessories Lab

ITEM-18384

This JK Lasers Class 4 MS20 Laser was removed from a university lab where it was surplus to requirements.


The unit came to us with a warning notice on it saying it is strictly not to be used or powered up under any circumstances. We suspect the university was removing it from their facilities for H&S reasons.


It is in reasonably good cosmetic condition but has some glue residue on the top of it and the wheels are stiff. There was also no key for the unit so we could not open the cabinet.


Lot contains:

1 x JK Lasers Class 4 MS20 Laser.

1 x Metal Plate.

1 x Shutter/Fire Switch.

1 x YAG Laser Flashlamp/Q-Switch Controller Glued Together.


The unit is sold for spares/repairs. We can only accept business customers for this item and any potential customer will be required to sign a disclaimer during purchase.


All offers considered on the unit.




Image of 6 x Laerdal Vitalsim Vital Signs Simulators

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

6 x Laerdal Vitalsim Vital Signs Simulators

ITEM-29947

6 x Laerdal Vitalsim Vital Signs Simulators


These were removed from a university lab where they were surplus to requirements.


All main units power on and all of the parts are in reasonable cosmetic condition. Some units are missing parts from the bags, and one does have a broken power connection on the back of the main unit which is also labelled.


They are sold as a spares/repairs lot.


Image of Bartington MS2WF Magnetic Susceptibility System Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Bartington MS2WF Magnetic Susceptibility System Lab Spares/Repairs

ITEM-42055

Bartington MS2WF Magnetic Susceptibility System


This system was removed from a university laboratory where it was surplus to requirements.


The units power on and are in good condition with minimal wear. The pumps function correctly, but an alarm sounds on the MS2WFP PSU.


Additionally, the system is missing the MS2 meter and probe.

Therefore, this system is listed as Spares/Repair.


Specifications:


  • MS2WFP Power Supply Unit
  • Model: MS2WFP
  • Serial No.: 134
  • MS2WF Furnace
  • Model: MS2WF
  • Serial No.: 134
  • MS2W Sensor
  • Model: MS2W
  • Serial No.: 150
Image of Record WPE 100 Electric Work Positioner Spares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Record WPE 100 Electric Work Positioner Spares/Repair

ITEM-46227

Record WPE 100 Electric Work Positioner


This item was removed from a university laboratory where it was surplus to requirements.


It powers on, but the buttons on the controller that move the tray are faulty and do not function.


Therefore, it is listed as Spares/Repair.

Image of Teledyne Isco CombiFlash Companion TS Personal Flash Chromatography System Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Teledyne Isco CombiFlash Companion TS Personal Flash Chromatography System Lab

ITEM-24519

Teledyne Isco CombiFlash Companion TS Personal Flash Chromatography System Lab


This was removed from a university lab where it was surplus to requirements.


The system powers up but the tablet will not communicate with the PC. It is in other wise good cosmetic condition with minor marks, but is sold for spares/repairs.


Included are;


Teledyne Isco CombiFlash Companion

Model - Combiflash Companion

SN - 207B20161



3 Tube Racks:-

The one slotted in the unit holds 100 x 15ml tubes

One holds 144 x 5ml tubes and has 99 Glass 5ml tubes included

One holds 100 x 15ml tubes and has 32 Glass 15ml tubes included


Fujitsu Siemens Tablet:-

Model - Stylistic ST5010

Part no. CP183709

SN - YBKT011032

Comes with Protective case, mouse and cables/adaptor.

Tablet has CombiFlash Companion Software


Image of Astell Hearson MN2950 Autoclave Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Astell Hearson MN2950 Autoclave Lab Spares/Repairs

ITEM-20667

This was removed from a university lab where it was surplus to requirements.


It is sold for spares/repairs as the wiring has been deemed unsafe.

Image of Molecular Dynamics Typhoon 8600 Variable Mode Imager Lab - Spares Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Molecular Dynamics Typhoon 8600 Variable Mode Imager Lab - Spares Repairs

ITEM-06512

Molecular Dynamics Typhoon 8600 Variable Mode Imager originated in a working Lab in a top UK University but is now surplus to requirements. 


The unit does not seem to power up. The unit is in reasonable condition but shows signs of wear and age.


Sold as spares or repair.






Image of Sorvall RC-3C Plus Refrigerated Lab Centrifuge Ultracentrifuge Spares / Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Sorvall RC-3C Plus Refrigerated Lab Centrifuge Ultracentrifuge Spares / Repairs

ITEM-13924

Sorvall RC-3C Plus Refrigerated Lab Centrifuge


This unit was removed from a lab due to a fault. The engineer reported that the fault was not economical for the lab to repair as it requires a new drive box which cannot easily be sourced.


The unit requires a 24Amp, 240V supply.


It is in good cosmetic condition with some marks from use.


Unit is sold as spares / repairs.

Image of Wallac 1450 Microbeta Trilux Liquid Scintillation -19994 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Wallac 1450 Microbeta Trilux Liquid Scintillation -19994 Lab Spares/Repairs

ITEM-19994

Wallac 1450 Microbeta Trilux Liquid Scintillation


The system tripped ad RCD on the main supply during testing. The internal PSU has shorted.


It is sold for spares/repairs.


Included are;


Microbeta V4.6 Protocol Disk

1450 Microbeta Trilux Main Program 4.6


Comes with:-

Belinea 15" Monitor - Powers on

HP Keyboard

Logitech Mouse

HP Vectra VL5/166 MMX Series 5 DT - PC Does not power on. HDD removed. We left it with the system in case it has useful PCI cards.


Image of Perkin Elmer Series 200 LC AutoSampler Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Perkin Elmer Series 200 LC AutoSampler Lab Spares/Repairs

ITEM-20652

Perkin Elmer 200 Series AutoSampler


This was removed from a university lab where it was surplus to requirements.


The unit powers up but is showing a flush motor fail error.


It is sold for spares/repairs.

Image of Dionex DX80 Analyzer Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Dionex DX80 Analyzer Lab Spares/Repairs

ITEM-26222

Dionex DX-80 Analyzer


This was removed from a university lab where it was surplus to requirements.


The unit powers up but we are told it was not in working order prior to collection. The pump is faulty.


It is sold for spares/repairs.



Image of Packard 9200 Hydrogen Generator B920000 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Packard 9200 Hydrogen Generator B920000 Lab Spares/Repairs

ITEM-28161

Packard 9200 Hydrogen Generator


This was removed from a university lab where it was surplus to requirements.


We had the unit looked at by a service engineer. It is fully working but is leaking hydrogen.


It is in reasonably good cosmetic condition, but has some marks from use.


it is sold for spares/repairs

Image of Beckman Coulter Avanti J-E Centrifuge  Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Beckman Coulter Avanti J-E Centrifuge Lab Spares/Repairs

ITEM-29745

Beckman Coulter Avanti J-E Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up but has several faults. The unit requires a new board, flash card and cooling system.


It is in good cosmeti condition with minor marks.


It is sold for spares/repairs.

Image of Sorvall RT6000D Refrigerated Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Sorvall RT6000D Refrigerated Centrifuge Lab Spares/Repairs

ITEM-31464

This Sorvall RT 6000D Refrigerated Centrifuge was removed from a university lab where it was surplus to requirements.


The unit powers up and runs, but does not cool. It seems to have a compressor fault


It is in good cosmetic condition with minor marks.


Sorvall H1000B Rotor

3600 Max RPM


4 x Du Pont Buckets (PN-11053)

2 x Blue Adaptors (Holds 4 x 50ml each)

2 x Black Adaptors (Holds 10 x 15ml each)


It is sold for spares/repairs

Image of Sanyo Ultra Low Temperature Freezer MDF-U4086S Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Sanyo Ultra Low Temperature Freezer MDF-U4086S Lab Spares/Repairs

ITEM-32034

Sanyo Ultra Low Temperature Freezer MDF-U4086S


This was removed from a university lab where it was surplus to requirements.


The unit does power up but does not cool at all. It has no refrigerant in it.


It is sold for spares/repairs.

Image of Heraeus Biofuge 22R Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Heraeus Biofuge 22R Centrifuge Lab Spares/Repairs

ITEM-35675

This Heraeus Biofuge 22R Centrifuge was removed from a university lab where it was surplus to requirements.


The unit powers up but does not run. We removed the front panel to investigate and at least two relays are sparking quite badly.


It is in good cosmetic condition with marks from use.


It is sold for spares/repairs.

Image of TOA Emergency Power Supply VX-2000DS Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

TOA Emergency Power Supply VX-2000DS Spares/Repairs

ITEM-36392

TOA Emergency Power Supply VX-2000DS


This was removed from a university lab where it was surplus to requirements.


The unit does not power up but is in good cosmetic condition with minor marks.


It is sold for spares/repairs.

Image of TOA Voice Alarm System Amplifier VM-3360VA Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

TOA Voice Alarm System Amplifier VM-3360VA Spares/Repairs

ITEM-36394

TOA Voice Alarm System Amplifier VM-3360VA


This was removed from a university lab where it was surplus to requirements.


The unit powers up but none of the buttons work, and the display is blank.


It is in good cosmetic condition with minor marks.


It is sold for spares/repairs.



Image of Thermo Electron Corporation Shandon Excelsior Tissue Processor Lab SPares/Repair

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Thermo Electron Corporation Shandon Excelsior Tissue Processor Lab SPares/Repair

ITEM-39981

This Thermo Electron Corporation Shandon Excelsior Tissue Processor was removed from a university lab where it was surplus to requirements.


The unit powered up initially but quickly faded.


It has a suspected PSU fault.


It is sold for spares/repairs.

Image of Buchi Distillation Chiller B-741 Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Buchi Distillation Chiller B-741 Lab

ITEM-41489

Buchi Distillation Chiller B-741 Lab


This item was removed from a university where it was surplus to requirement.


It powers on but is in poor cosmetic condition, we are unable to test it further at our facility.


The unit is sold for spares/repairs as we believe it will need quite a bit of remedial action to get it working properly.


It is missing one of is feet.

Image of Merck Hitachi L-7480 Fluorescence Detector Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Merck Hitachi L-7480 Fluorescence Detector Lab Spares/Repairs

ITEM-44420

Merck Hitachi L-7480 Fluorescence Detector


This item was removed from a university laboratory where it was surplus to requirements.


The unit is in reasonably good cosmetic condition externally. However, upon testing, the unit tripped the circuit multiple times.


An internal battery, which was mounted in the top of the unit, has leaked and caused significant damage to the circuit boards beneath it, explaining the electrical issues. The battery has been removed, but the damage to the components is considerable.


Therefore, it is listed as Spares/Repair.


Specifications;

  • Model: L-7480
  • Part No.: 810-0482
  • Serial No.: 0601-074
Image of Sigma 3K15 Benchtop Centrifuge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Sigma 3K15 Benchtop Centrifuge Spares/Repair Lab

ITEM-46334

Sigma 3K15 Benchtop Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


It is in reasonable cosmetic condition but is listed as spares or repairs due to several operational issues.


The control buttons are unreliable, and the display screen is malfunctioning, frequently switching between temperature and time settings without stabilizing.


Although the display is set for the 5500 rotor, which is installed, it cannot start due to error code 99. This error indicates that the rotor selected on the centrifuge does not match the one installed

Image of Thermo Scientific Heraeus Pico 17 Centrifuge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Thermo Scientific Heraeus Pico 17 Centrifuge Spares/Repair Lab

ITEM-46956

Thermo Scientific Heraeus Pico 17 Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


It powers on, however, the unit's buttons do not respond, preventing lid opening, program changes, or operation checks.


Therefore, it is listed as Spares/Repair.


Includes:


  • Rotor: Thermo Scientific 75003424

 Max Speed: 14,800 rpm

 Capacity: 24 x 1.5–2 ml tubes (24 x 4 g max)


Image of Alpha Innotech Multi Image II FluorChem FC2 UV & Light Cabinet Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Alpha Innotech Multi Image II FluorChem FC2 UV & Light Cabinet Spares/Repair Lab

ITEM-47202

Alpha Innotech Multi Image II FluorChem FC2 UV & Light Cabinet Lab


This item was removed from a university lab where it was surplus to requirements.


It is in good cosmetic condition and powers on. The white light is functioning; however, no UV output was observed from the transilluminator.


Therefore, it is listed as Spares/Repair.

Image of SciQuip Oven-55S Incubator - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

SciQuip Oven-55S Incubator - Spares/Repair Lab

ITEM-47274

SciQuip Oven-55S Incubator


This item was removed from a university lab where it was surplus to requirements.


It is in good cosmetic condition and powers on; however, during testing it failed to reach the set temperature of 37°C, only reaching 23°C.


Therefore, it is listed as spares or repair.

Image of 202Centurion Scientific PRO-VET Multi Benchtop Centrifuge - Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

202Centurion Scientific PRO-VET Multi Benchtop Centrifuge - Spares/Repair Lab

ITEM-48415

Centurion Scientific PRO-VET Multi Benchtop Centrifuge


This item was removed from a university laboratory where it was surplus to requirement.


It is in good cosmetic condition and was tested successfully, however, the previous owner reported that the centrifuge would start a programme but fail to complete the run, with the fault believed to be related to the inverter.


Due to the reported fault, the unit is listed for spares or repair.

Image of Astell AMB220 Autoclave Spares/Repair (Cracked Chamber) Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Astell AMB220 Autoclave Spares/Repair (Cracked Chamber) Lab

ITEM-48454

Astell AMB220 Autoclave Crack in Chamber - Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on, however, the previous owner stated that the internal chamber has cracked.


Therefore, it is listed as Spares/Repair.

Image of Eppendorf 5415R Benchtop Centrifuge Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Eppendorf 5415R Benchtop Centrifuge Spares/Repair Lab

ITEM-48695

Eppendorf 5415R Benchtop Centrifuge Spares/Repair Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, however during testing the code ' Error 3' was displayed, preventing further testing.


Therefore, it is listed as Spares/Repair.

Image of Oriel Arc Lamp with Arc Lamp Ignitor & 300-500W Xe & Hg Power Supply Faulty

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Oriel Arc Lamp with Arc Lamp Ignitor & 300-500W Xe & Hg Power Supply Faulty

ITEM-36893

Oriel Arc Lamp with Arc Lamp Ignitor & 300-500W Xe & Hg Power Supply


Included are;


Oriel 300-500W Xe and Hg(Xe) Power Supply

Model - 68811

SN - 120


Oriel Arc Lamp

Model - 77504

SN - 118


Oriel Arc Lamp Ignitor

Model - 68705

SN - 253


All units connect together and the power supply powers on. When lamp start was pressed there was a pulsing sound and a flicker of light but nothing more.


It is sold for spares/repairs.


Image of Haake K20 Circulating Chiller Water Bath w/ C10 Controller Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Haake K20 Circulating Chiller Water Bath w/ C10 Controller Spares/Repairs

ITEM-36442

Haake K20 Circulating Chiller Water Bath w/ C10 Controller


This was removed from a university lab where it was surplus to requirements.


The unit did not power up in testing and blew two separate step-down transformers.


It is in reasonable cosmetic condition with minor marks.


It is sold for spares/repairs.

Image of Sorvall Legend RT Centrifuge w/ 4600rpm Swinging Arm Rotor Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Sorvall Legend RT Centrifuge w/ 4600rpm Swinging Arm Rotor Lab Spares/Repairs

ITEM-36501

Sorvall Legend RT Centrifuge


This system was removed from a university lab where it was surplus to requirements.


The unit powers on, but it shows Error 21 when attempting to spin, causing the unit to cut out. The refrigeration system functions well, and the unit is in good cosmetic condition with minor marks.


Due to the error, this item is listed as Spares/Repair.


The unit is fitted with the following rotor:


  • Sorvall Rotor
  • P/N: 75006445
  • S/N: 004061

Includes:

  • 4 x Sorvall Swinging Buckets
  • P/N: 75015679
Image of Stratasys Dimension SST 768 Commercial 3D Printer - Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Stratasys Dimension SST 768 Commercial 3D Printer - Spares/Repairs

ITEM-36514

Stratasys Dimension SST 768 Commercial 3D Printer


This was removed from a university lab where it was surplus to requirements.


The unit fails PAT testing on insulation and also tripped testing room fuse board when plugged in.


It is in reasonable cosmetic condition but has cracks and marks from use, including damage to the window.


It is sold for spares/repairs.

Image of Beckman Coulter Allegra 6R Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Beckman Coulter Allegra 6R Centrifuge Lab Spares/Repairs

ITEM-36589

Beckman Coulter Allegra 6R Centrifuge


This was removed from a university lab where it was surplus to requirements.


The unit powers up but does not operate. We believe it to have a faulty drive belt.


It is sold for spares/repairs.

Image of Wheaton 348885-D Deck R2P WX 9 DK Roller Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Wheaton 348885-D Deck R2P WX 9 DK Roller Lab Spares/Repairs

ITEM-36446

Wheaton 348885-D Deck R2P WX 9 DK Roller


This unit failed a PAT test on both insulation and earth.


It is in good cosmetic condition with minor marks but is sold for spares/repairs.

Image of Jouan SA GR 20 22 Refrigerated Centrifuge with AG 290.G Rotor Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Jouan SA GR 20 22 Refrigerated Centrifuge with AG 290.G Rotor Spares/Repair Lab

ITEM-40950

Jouan SA GR 20 22 Refrigerated Centrifuge with AG 290.G Rotor


This item was removed from a university laboratory where it was surplus to requirements.


It is in good cosmetic condition and powers on, but the display shows "Lid Unlocked" while the lid remains stuck most of the time, occasionally opening after multiple attempts.

Additionally, the display indicates "Tachometer Failure."

When set to 2000g RCF, it does not reach the target speed, instead decelerating after approximately 500g. The deceleration from 500g to 0g takes approximately six minutes.


Due to the faults listed above, this centrifuge is listed as Spares/Repair.


Includes:

  • 1x Jouan AG 290.G Swing Bucket Rotor
  • 4x Jouan Swing Buckets (C/N: 11174649, S/N: 0102/03)
  • 1x Box of assorted fixed-angle and swing buckets with no markings, various sizes of test tube adaptors
  • 4x 125 ml Tube Adaptors
  • 4x Support Feet

Image of Qiagen QIAcube HT QIAxtractor System w/ VS04 Pump Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Qiagen QIAcube HT QIAxtractor System w/ VS04 Pump Spares/Repair Lab

ITEM-40952

Qiagen QIAcube HT QIAxtractor Nucleic Acid Purification System w/ VS04 Pump


This system was removed from a university laboratory where it was surplus to requirements.


The Qiagen QIAcube HT is in good condition and powers up; however, it has a broken belt that is responsible for the forward and backward movement.


As a result, the system is sold as Spares/Repair.


System Includes:

  • Qiagen QIAcube HT QIAxtractor
  • Serial Number: 009284
  • Qiagen Vacuum Pump Model VS04
  • Serial Number: 009318
Image of Buchi Distillation Chiller Model B-741 Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Buchi Distillation Chiller Model B-741 Lab Spares/Repairs

ITEM-41105

Buchi Distillation Chiller Model B-741


This was removed from a university lab where it was surplus to requirements.


The unit failed a visual PAT as it is missing the side panel test and was not tested further.


It is sold for spares/repairs

Image of Waters 2525 Binary Gradient Module Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Waters 2525 Binary Gradient Module Lab Spares/Repairs

ITEM-41181

Waters 2525 Binary Gradient Module Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition but does not power on. Therefore, we are unable to test it, and it is listed as Spares/Repair.

Image of Teikos TS601 PW DET PS Dishwasher Lab Spares/Repairs.

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Teikos TS601 PW DET PS Dishwasher Lab Spares/Repairs.

ITEM-41246

Teikos TS601 PW DET PS Dishwasher


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition internally, and externally.


When powered on, it tripped the power at our facility, therefore we are unable to test it, and it is listed as Spares/Repairs.

Image of Neslab CFT-75 Coolflow Refrigerated Recirculator Chiller Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Neslab CFT-75 Coolflow Refrigerated Recirculator Chiller Lab Spares/Repairs

ITEM-41632

NesLab CFT-75 Coolflow Refridgerated Recirculator Lab


This item was removed from a university where it was surplus to requirement.


It is in reasonably good cosmetic condition and powers on. However, due to the following faults it is listed as Spares/Repair.


Faults:

  • The coupling is snapped between the motor and the pump head.
  • There is no water being recirculated.
  • Pump head appears to be seized.

Image of NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs

ITEM-41633

NESLAB Coolflow CTF33 Refrigerated Recirculator Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition and powers on, although we were unable to set the desired temperature due to a display fault.


Therefore, it is listed as Spares/Repair.

Image of Heraeus Instruments Labofuge 400R Function Line Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Heraeus Instruments Labofuge 400R Function Line Lab Spares/Repairs

ITEM-41702

Heraeus Instruments Labofuge 400R Function Line Lab


This item was removed from a university where it was surplus to requirement.


It is in fairly poor cosmetic condition and powers on, however, due to an issue with the cooling/heating element it did not reach any desired temperature when tested.


Therefore, it is listed as Spares/Repair.


Additionally, it was tested to its maximum speed of 4500RPM, which performed well with no issues.




Image of Beckman Optima L-60 Floor Standing Centrifuge Lab Spares/Repairs

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Beckman Optima L-60 Floor Standing Centrifuge Lab Spares/Repairs

ITEM-42198

Beckman Optima L-60 Floor Standing Centrifuge


This item was removed from a university laboratory where it was surplus to requirements.


The centrifuge powers on and is in good cosmetic condition.


However, the display is not functioning correctly, showing only  two dots in the TIME-HR-MIN and one dot in TEMP-°C.


Due to these issues, it is listed as Spares/Repair.


There is no rotor included.


Specifications:

  • Speed: 1,000 - 60,000 rpm
  • Temperature: 0°C - 40°C

Model: Optima L-60 Serial No.: L1M602

Rotational Counter: 417,132 x 10,000 rotations

Image of VWR Incubated Microplate Shaker Model No. 980141UK Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

VWR Incubated Microplate Shaker Model No. 980141UK Lab

ITEM-48322

VWR Incubated Microplate Shaker Model No. 980141UK


This item was removed from a facility where it was surplus to requirements.


The unit powers on and functions, but it has failed the PAT due to an insulation fault related to the heating element.


Therefore, it is listed as Spares/Repair.


Model: 980141UK

Image of GE P-900 Pump for AKTA Purifier System Spares/Repair Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

GE P-900 Pump for AKTA Purifier System Spares/Repair Lab

ITEM-47188

GE P-900 Pump for AKTA Purifier System – Spares or Repair


This item was removed from a university laboratory where it was surplus to requirements.


The pump powers on and initialises correctly without any error messages. However, it has been listed as Spares/Repair because part of the pump pressure transducer has been removed, meaning it will not operate correctly.

Image of Beckman L8-80MW Ultracentrifuge Lab

SPARES/REPAIR ITEM

SPARES/REPAIR ITEM

£ 250.00 (ex. VAT) 1 in stock

Beckman L8-80MW Ultracentrifuge Lab

ITEM-44394

Beckman L8-80 Ultracentrifuge Lab


This item was removed from a university where it was surplus to requirement.


It is in good cosmetic condition externally and powers on, however, when tested we attempted to run the unit with a 70Ti rotor (not included), but encountered cooling system and speed sensor errors.

Also, oil was discovered under the rotor and in the chamber/motor area, possibly due to a worn seal.


Due to the above faults, this item is listed as Spares/Repair.


The 3-phase plug has been removed and there is no rotor included in the sale.


Also included:


1 x Operation Key

1 x Original User Manual

Items 101 to 150 of 308

Filters

Price (£)

to

Condition