All Products
Items 1951 to 2000 of 3190
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
NESLAB Coolflow CFT-33 Refrigerated Recirculator Lab Sapres/Repairs
ITEM-41633
NESLAB Coolflow CTF33 Refrigerated Recirculator Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, although we were unable to set the desired temperature due to a display fault.
Therefore, it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Yaskawa Electrics Motoman YR HP3J-J01 w/ Power Supply & Controller Lab Faulty
ITEM-40021
Yaskawa Electrics Motoman YR HP3J-J01 w/ Power Supply & Controller Lab
This system was removed from a university where it was surplus to requirement.
The power supply and controller power up.
When powered, the controller displays 0220 subcode 1 error on startup:
'The management data of job files are damaged'
Thus, preventing any further testing from being conducted, and as a result, this item is listed as Spares/Repair.
All items are in good cosmetic condition with no damage present.
All cables seen in the photos are included.
Parts include:-
Motoman Manipulator
Type: YR-HP3J-J01
Order#: S7Q732-1-1
Serial#: S7Q732-1-1
NXC 100 Power Supply
Type: ERCR-NS00-A200
Order#: S7Q732-2
Serial#: S66B65-2
Mfd: 09-2008
Controller
Type: JZRCR-NPP01B-1
Serial#: A037259
Mfd: 08-2007
Also includes:
6 x MOTOMAN Disk
Visionscape Softare Disk
3 x Motoman NXC100 Controller Manual Disk
XRC Controller Function Manual Disk
2 x Motosoft Disk
Motosoft Dongle
Lexar Platinum 256MB Compact Flash Drive
busbi 2GB Compact Flash Drive
Fujifilm 64MB Compact Flash Drive
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman L8-80MW Ultracentrifuge Lab
ITEM-44394
Beckman L8-80 Ultracentrifuge Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition externally and powers on, however, when tested we attempted to run the unit with a 70Ti rotor (not included), but encountered cooling system and speed sensor errors.
Also, oil was discovered under the rotor and in the chamber/motor area, possibly due to a worn seal.
Due to the above faults, this item is listed as Spares/Repair.
The 3-phase plug has been removed and there is no rotor included in the sale.
Also included:
1 x Operation Key
1 x Original User Manual
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf Realplex 4 MasterCycler Epgradient S Real Time Cycler 96-Well Lab
ITEM-31867
Eppendorf Realplex 4 MasterCycler Epgradient S Real Time Cycler 96-Well
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however it does not include the required controller. We made several attempts to connect it to the software from another unit (not included), but it would not communicate Therefore, it is listed as Spares/Repair.
Includes an Eppendorf USB drive with pre-installed software and a digital user manual.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Applied Thermal Control K4 K410000W Industrial Recirculating Chiller Lab Faulty
ITEM-37631
Applied Thermal Control K4 K410000W Industrial Recirculating Chiller
This item was removed from a university where it was surplus to requirement.
It is in very good cosmetic condition and powers up.
The previous owner has reported that the recycling water has been contaminated with coolant.
Therefore, it will need to be serviced for recommissioning and is listed as Spares/Repairs as a result.
Product Details:
Model K410000W
Serial No. 190348
4.5kw cooling capacity
Temp range 4 to 35˚C
17L/min flow rate
10 bar max
£ 500.00 (ex. VAT) 1 in stock
Job Lot of Projector Lens Hitachi Kodak Sanyo Elmo Isco-Gottingen Lab
ITEM-37209
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
Included are;
- 4 x Sanyo LNS - S20
- 2 x Hitachi LL-503
- 1 x Hitachi LL- 504
- 1 x Isco-Gottingen F =250mm
- 1 x Kodak Carousel S-AV2000 F = 150mm
- 1 x Kodak Retinar F = 60mm
- 1 x Schneider-Kreuznach Carousel Procolar F = 100mm
- 3 x Kodak Slide Projection FF Lens F = 100-200mm
- 1 x Kodak Retinar F = 250mm
- 1 x Elmo zoom lens F = 180-300mm
- 1 x Isco-Gottingen Vario-Projar 70-120mm
- 1 x Kodak Retinar F = 150mm
- 2 x Kodak Retinar F = 180mm
- 2 x Kodak Long Focal Length Lens
- Assortment of glass lens and bulbs
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
LEEC Touch 50 Culture Safe CO2 Incubator Lab Spares/Repairs
ITEM-38889
LEEC Touch 50 Culture Safe CO2 Incubator
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on. (Thermometer not included)
The CO2 sensor has failed on testing, therefore it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
RMC CR21, CR21 Control, Transformer & Cryochamber Lab
ITEM-39828
RMC CR21, CR21 Control, Transformer & Cryochamber Lab
These items were removed from a university where they were surplus to requirement.
All the units are in reasonably good cosmetic condition. However, they cannot be tested as they all require a connection to the transformer, which is not operational.
Therefore, this listing is sold as Spares/Repair.
All items included are as follows:
Model1#: CR21 Controller
Serial1#: 10521389
Model2#: CR21 Transformer Box
Serial2#: 10521391
Model3#: CR21 Cryochamber
Serial3#: 10521390
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Perkin Elmer Flexar UV/VIS LC Detector Lab
ITEM-41324
Perkin Elmer Flexar UV/VIS LC Detector Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on. However, when powered on, this item displays a red warning light. The lab had also reported that it had issues.
Therefore, it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Job Lot of Mixed Benchtop Lab Equipment - Coherent, MSE, StarTech, Dedotecs
ITEM-41527
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
ITEM-41222 Coherent Cube 405nm
ITEM-41220 2 x CEM-09A-II Monitors w/ cables
ITEM-41368 Planner Products LTD Power Supply Box Model LNP4 PSU
ITEM-41369 Sanyo MSE Micro Centaur Centrifuge
ITEM-41370 Bio-Rad Model-1000/500 Power Supply
ITEM-41371 Bio-Rad Power Pac 300
ITEM-41372 Bio-Rad Power Pac 3000
ITEM-37181 Fisherbrand FB 70155
ITEM-37178 Biotek Valve Module
ITEM-41433 MSE MicroCentaur Centrifuge
ITEM-41381 Mover Link F01828
ITEM-41382 Mini-Hub F01928
ITEM-41384 StarTech Com
ITEM-41385 Bespoke Server
ITEM-37184 Moxa NPort 5610-8 Device Server
ITEM-37182 Dedotec Dedocool COOL
ITEM-40026 SMC AW20-N02H-CZ Pneumatic Regulator Filter
ITEM-40027 Thermo Fisher Ngs, Gripper Finger Assy V3
ITEM-40028 Nikon Plan Fluor 100x/1.30 Oil Damaged
ITEM-40029 3 x Damaged Objectives
ITEM-41558 LabNet Multigene
ITEM-41559 helena biosciences Phoenix model-FGEN05TH
ITEM-41562 Grant W28 Lab Water Bath Heating
ITEM-41563 Hybaid Mini Oven Mk 2
ITEM-41442 Jedcod Auto Dosing Pump DP-2
ITEM-41443 Hanna Instruments pH 209 pH Meter
ITEM-41446 Jena GmbH EBQ 100
ITEM-39950 Coherent Innova I300C
ITEM-39951 Laser Hose
ITEM-24750 Bio-Rad Power Pac 3000 Electrophoresis Power Supply Lab
ITEM-17790 Fisons MSE Micro Centaur Centrifuge / Microcentrifuge Lab Spares or Repairs
ITEM-16565 Consort E455 Microcomputer Electrophoresis Power Supply Lab
ITEM-12464 Lot of 2x Cambridge Thermometers Lab Equipment
ITEM-17642 MSE Sanyo Micro Centaur Centrifuge Microcentrifuge Lab Spares or Repairs
ITEM-24748 Fisher Scientific FB1000 Electrophoresis Power Supply Lab
ITEM-18131 AIW Corp P-136-29-MSHA 18 AWG 6/C SOOW-A 105C 600V Cable (UL) Halogen Lamp
ITEM-16595 Watson-Marlow H.R. Flow - Inducer Type - MHRE Peristaltic Pump Lab
ITEM-24737 Techne TC-3000x FTC3X/05 Thermal Cycler Lab Spares/Repairs
ITEM-16732 Volpi Intralux 150H Fiber Optic Light Source Lab
ITEM-15978 HARTING Han Plug & Connector Cable (33 Feet) from Balzers UMS 630 UHV Lab
ITEM-15977 HARTING Han Cable (35 Feet) with plug 31 Pin Female from Balzers UMS 630 UHV Lab
ITEM-12678 Foxboro Temperature Gauge Centigrade Steam Calibration
ITEM-17561 5 x Eti Ltd Superfast Thermapen Electric Thermometers Lab
ITEM-13625 GMT PR Pat No 47774/68 MT3 Dead Centre with Flip-Over Pilot Drill for Lathe
ITEM-17454 Integra Fireboy Plus Portable Safety Bunsen Burner Lab
ITEM-15976 HARTING Han Cable with Connector 19 Feet from Balzers UMS 630 UHV Lab
ITEM-17564 Hach Pocket Colorimeter II Chlorine Analysis System Lab Spares or Repairs
ITEM-15975 HARTING Han 20 Foot 42 Pin Plug & Connector Cable from Balzers UMS 630 UHV Lab
ITEM-24999 Vickers Stereo Microscope
ITEM-25000 Vickers Stereo Microscope
ITEM-25001 Vickers Stereo Microscope
ITEM-24745 Nikon SMZ-1B Stereo Zoom Microscope Lab
ITEM-17568 5 x Barton TC7 Storage Containers Tubs Size 7 H200 x W310 x L520mm
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Galaxy 170 S CO2 Incubator Lab Spares/Repairs
ITEM-39054
New Brunswick Galaxy 170 S CO2 Incubator
This was removed from a university lab where it was surplus to requirements.
The unit powers up, but due to drastically fluctuating reading on display, this item is sold as Spares or Repairs.
It is in very good cosmetic condition, both internally and externally.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire NU-5800E C02 Incubator Lab Spares/Repairs
ITEM-39096
Nuaire 5800E C02 Incubator Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on. (Thermometer not included)
The CO2 sensor has failed on testing, therefore it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Nuaire NU-5810E CO2 Incubator Lab Spares/Repairs
ITEM-39095
Nuaire 5810E CO2 Incubator Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on. (Thermometer not included)
The CO2 did not increase on testing, and the sample pump failed, therefore it is listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Mixed Job Lot of Laboratory Equipment - IKA, Stuart, Metrohm, Kroy, Elga etc
ITEM-38186
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares / repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the unit. It is an excellent opportunity for anyone looking to benefit for individual equipment resale.
The units have not been tested at all.
ITEM-34625 Lot of Hanna Instruments pH Meters
ITEM-41847 Metrohm 830 IC interface
ITEM-41848 Metrohm 833 IC Liquid Handing Unit
ITEM-41849 Metrohm 818 IC Pump
ITEM-38036 Thermo Px2 Thermal Cycler With Thermo Hybaid PCR Express Lab
ITEM-41914 HP 107a Laser Printer
ITEM-41915 Lot of Three Of Cole-Parmer SHM-200 Heating Mantles
ITEM-41916 IKA MSC Basic C Heated Stirring Plate
ITEM-41917 Kroy K3110-PC Thermal Printer
ITEM-41920 Pair of Thurlby 1503-HA Digital Multimeters
ITEM-41921 Lot of 3 Advanced Instruments DMM2 Digital Multimeters
ITEM-41922 Gould Advance DMM7A Digital Multimeter
ITEM-41923 Philips PW9526 Digital Conductivity Meter
ITEM-41924 Griffin Magnetic Stirrer
ITEM-41925 Electrothermal M105 Heating Mantle
ITEM-41926 Pair of Electrothermal M103 Heating Mantles
ITEM-41927 Pair of Electrothermal ML02 Heating Mantles
ITEM-41928 Reeve Computer Interface Control Box With Marconi RB2 Tracker Ball
ITEM-41929 Tekman TE 200 Graph Printer Plotter
ITEM-41930 Stuart 6M4 Magnetic Stirrer
ITEM-41931 Pair of Griffin and George Galvanometers
ITEM-41932 Reeve 9701 Radio Activity Monitor
ITEM-41933 Pair of Bellingham and Stanley Polarimeters
ITEM-41934 Meta Therm HPLC Column Control
ITEM-41935 Elga Purelab Option Water Purifier Model OR007BPM1
ITEM-41936 Pair of Buchi B-169 Vacuum Systems
ITEM-41945 Four Position Ammeter Control Box With two RS Ammeters
ITEM-41947 Lot of 4 Nuclear Enterprises SR7 Scaler Ratemeters
ITEM-41948 Goerz Electro Potentiometer Schreiber Servoscribe Type RE 511
ITEM-41949 Camag Universal UV Lamp Type TL-900
ITEM-41950 Lot of 11 NE Technology ST7 Scaler Timers
ITEM-41955 Metcalf Brothers Hyflow Air Pump Model C
ITEM-41956 Bellingham and Stanley Refractometer
ITEM-41957 Thermo Separation Products Spectra Series UV Single Wavelength Detector ITEM-41958 Brooks 5850E Mass Flow Controller
ITEM-41959 Hewlett-Packard Model 17422B 10v Power Adapter
ITEM-41961 Advance Instruments DMM2 Digital Multimeter
ITEM-41962 Stuart SMP11 Melting Point Apperatus
ITEM-41963 Pair of Fluke 8050A Digital Multimeters
£ 500.00 (ex. VAT) 1 in stock
Finnigan MAT LCQ Mass Spectrometer System Lab Spares/Repairs
ITEM-30021
Finnigan MAT LCQ Mass Spectrometer System
This system was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, however, due to the breaker switch being broken we are unable to power it on or conduct further testing.
Therefore, it is listed as Spares/Repair.
£ 500.00 (ex. VAT) 1 in stock
Lot of Laboratory Glassware Flasks, Pipettes etc Fisher, Quikfit, Pyrex Lab
ITEM-42000
Lot of Laboratory Glassware Flasks, Pipettes etc Fisher, Quikfit, Pyrex Lab
A large collection of laboratory glassware which is mostly unused.
These items were removed from a university lab, where they were surplus to requirement.
All included items range from Excellent/Unused to Good cosmetic condition with no damage sustained.
Included are as follows:
31 x Quickfit 250ml Elenmeyer conical flasks with collar and hollow glass stopper
27 x 500ml Pyrex heavy duty glass conical filter flasks with side arm tubulation
24 x 250ml Pyrex conical filter flasks with side arm tubulation
22 x Pyrex long funnels 20cm length 7cm diameter
21 x short funnels 12cm length 4cm diameter, 9 of which are fitted with rubber bungs
100 x Fisherbrand test tubes 24 x 150 soda rimless, code FB63116
10 x boxes of 250 pieces Fisherbrand glass pipettes 23cm length, code FB50253
3 x thistle funnels 23cm length 3cm diameter
3 x Shandon Unikit chromatography 3 litre jars with lids but missing inner columns
99 x Sorvall tubes 5ml
£ 500.00 (ex. VAT) 1 in stock
Oxford Cryogenics Cryostream Controller 600 Series with 171 Cold Head System Lab
ITEM-37640
Oxford Cryogenics Cryostream Controller 600 Series with 171 Cold Head
This system was removed from a university where it was surplus to requirement.
Both the Controller and Cold Head power on and communicate, we are unable to test them further at our facility.
They are in good cosmetic condition.
A data cable to connect the Cold head to the controller is included.
£ 500.00 (ex. VAT) 1 in stock
Lot of Assorted Pipette Tips Storage Boxes Lab
ITEM-40934
Assorted Pipette Tips Storage Boxes Lab
This item was removed from a university lab where it was surplus to requirements.
All items vary in condition with minor surface damage and pen marks present.
£ 500.00 (ex. VAT) 1 in stock
Lapmaster Monochromatic Light Source Lab
ITEM-44837
Lapmaster Monochromatic Light Source Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
£ 500.00 (ex. VAT) 1 in stock
Sanyo Model MDF-U730M Biomedical Freezer Lab
ITEM-44674
Sanyo MDF-U730M Biomedical Freezer Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order (thermometer not included).
It is in good cosmetic condition.
Includes:
6 x Shelves - 62 x 62cm
14 x Containers - 62 x 31 x 16cm
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Essen BioScience IncuCyte Zoom Live Cell Analysis System Lab Sapres/Repairs
ITEM-39967
This Essen BioScience IncuCyte Zoom Live Cell Analysis System was removed from a university lab where it was surplus to requirements.
Both units power up but when attempting to pair the system, Essen BioScience IncuCyte Zoom Controller reads "Device Error: CPU C-States"
Due to this error, the system is listed as Spares or Repairs.
The system comprises of;
Essen BioScience IncuCyte Zoom Microscope
Model: IncuCyte ZOOM
Serial#: 45520
Essen BioScience IncuCyte Zoom Controller
Model: IncuCyte ZOOM
Serial#: 40520
Free Space: 1.2 TB
Runs: Windows 7
Also included:
Various well plate brackets
Essen BioScience IncuCyte Accessories Box
-USB 2.0 to 10/100Mbps Ethernet Adapter
-IncuCyte Dual Color Fluorescence Calibration Slide Kit
-Key set
Essen BioScience IncuCyte Optical Components Box
-Allen key
-V lier key
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Miele Professional G 7883 Lab Glassware Washer Spares/Repairs
ITEM-35868
Miele Professional G 7883 Lab Glassware Washer
The unit did not power up in testing. It is sold for spares/repairs.
It is in good cosmetic condition with minor marks.
£ 500.00 (ex. VAT) 1 in stock
Kryo Planer Biomed 10 Series System Lab Spares/Repairs
ITEM-37143
Kryo Planer Biomed 10 Series System
This system was removed from a university where it was surplus to requirement.
The system failed PAT on insulation. It is sold for spares/repairs.
1x Kryo 10 Series Controller:
Model 10-20
1x Kryo 10 Series Controller:
Model 10-20
1x Kryo 10 series Controller Key
All units listed above power on and are in good cosmetic condition, neither have been tested further at our facility.
1x LNP4 Planer freezer Pump:
Model LNP4 13181
This item is in reasonably good cosmetic condition, but due to it requiring a separate power supply, we are unable to test it at our facility.
£ 500.00 (ex. VAT) 1 in stock
21 x Fisherbrand 5000ml Conical Flasks FB33137 Lab
ITEM-36620
21 x Fisherbrand 5000ml Conical Flasks FB33137
These were removed from a university lab where they were surplus to requirements.
The units are used but are in good condition.
£ 500.00 (ex. VAT) 1 in stock
Pair of FluidX XTR-Single Tube Readers Lab
ITEM-34735
2 x FluidX XTR-Single Tube Reader Lab
These items were removed from a university lab where they were surplus to requirements.
Both items power up and are in good cosmetic condition.
£ 500.00 (ex. VAT) 1 in stock
Jouan B4i Benchtop Centrifuge with S40 Rotor Lab
ITEM-29821
This Jouan B4i Benchtop Centrifuge was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. It is in good cosmetic condition with minor marks.
This item includes the following rotor:
Thermo Jouan High Throughput Swing-Out Rotor Model S40
Max Load 2.00kg
Max speed 4300 (rpm)
This item ran at 4000rpm with S40 Rotor fitted.
As stated in the manual, the maximum speed for a swing-out rotor on this unit is 4000 rpm.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
CTC Analytics Leap HTC PAL Autosampler Parts HPLC Chromatography Lab
ITEM-37704
This CTC Analytics Leap HTC PAL Autosampler Heating and Cooling HPLC system was removed from a university lab where it was surplus to requirements.
All units are in reasonably good cosmetic condition.
The main autosampler unit powers on and was tested with a digital thermometer (not included).
All other units are untested, therefore this system is sold as Spares or Repairs.
All items included:
Main Autosampler unit MXY 01-01B serial No. 111088
3 x power supply units MN 01-00
Peltier Thermostat unit MN 03-02
Stack Cooler MC 04-01 Rev.G
Control Pad MB 01-00A
2 x Peltier Thermostats MN 03-00
3 x Control Pads MB 01-00A
2 x MZ 01-00F injector columns missing injector needle holder
1 x MZ 01-00D injector column missing injector needle holder
1 x MZ 06-00D injector column missing injector needle holder
1 x MXY 03-01A main bridge unit serial No. 130176
2 x pairs legs 23cm high and 17cm high
2 x suspended sample shelves 23 x 13cm and 26 x 20cm
2 x keypad holding brackets
2 x pairs brackets for shelves
2 x power leads
2 x data cables
1 x keypad data cable
£ 500.00 (ex. VAT) 1 in stock
INTEK LH200 Fraction Collector Lab
ITEM-37686
This INTEK LH200 Fraction Collector was removed from a university lab where it was surplus to requirements.
The item powers on and is in good cosmetic condition, we are unable to test it further at our facility.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Heracell 240i CO2 Incubator Lab Spares/Repairs
ITEM-31726
Thermo Scientific Heracell 240i CO2 Incubator
This was removed from a university lab where it was surplus to requirements.
The unit has no screen and required a new CO2 sensor prior to the screen being removed.
It is sold for spares/repairs.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Amersham Biosciences AKTA FPLC System UPC-900 P-920 Spares/Repairs Lab
ITEM-36537
Amersham Biosciences AKTA FPLC System
This was removed from a university lab where it was surplus to requirements.
The unit powers up and has been serviced, but failed the service.
It is sold for spares/repairs.
Included are;
1x Amersham Biosciences AKTA FPLC System UPC-900 P-920
C/N: 18-1118-67
System/N: 01098245
1x UPC-900
C/N: 18-1128-95
S/N: 01099325
1x P-920
C/N: 18-1164-68
S/N: 01099849
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Heraeus Instruments Labofuge 400R Function Line Lab Spares/Repairs
ITEM-41702
Heraeus Instruments Labofuge 400R Function Line Lab
This item was removed from a university where it was surplus to requirement.
It is in fairly poor cosmetic condition and powers on, however, due to an issue with the cooling/heating element it did not reach any desired temperature when tested.
Therefore, it is listed as Spares/Repair.
Additionally, it was tested to its maximum speed of 4500RPM, which performed well with no issues.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Mixed Job Lot of Laboratory Equipment, Watson, Grant, MSE, Solex, Grant-Bio
ITEM-38149
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
ITEM-21092 2 x Watson Microscope Microsystem 70 Microscopes
ITEM-21083 N20010 Honeywell Damper Actuator
ITEM-24092 InterM PP-9214 Pre Amplifier
ITEM-24091 Inter M PP-9214 Pre-Amplifier
ITEM-29989 Jencons Perimatic GP
ITEM-17200 Invitrogen Safe Imager Blue-Light Transilluminator S37102 Lab Spares/Repairs
ITEM-29628 Netzeinheit NE-171 HV Power Supply
ITEM-21217 Marconi Instruments LTD VSWR Indicator 6593A
ITEM-29998 Solex SC-410 Analytical Balances 1dp
ITEM-29997 Grant QBD2 Dry Block Heater Lab
ITEM-29984 Grant QBD2 Block Heater (No Block).
ITEM-29999 Solex SC-410 Analytical Balances 1dp Lab
ITEM-21150 MSE Micro Centaur
ITEM-16892 Busicom UV Light Money Detector Model MD-1982V
ITEM-21149 Techne TC3000 Thermal Cycler
ITEM-17233 Hettich Mikroliter Centrifuge
ITEM-19081 Grant Water Bath Type ZA
ITEM-17248 ELGA ELGASTAT UHQ PS Water Purification System Lab
ITEM-29653 Buchi Rotavapor R-200
ITEM-21138 Jun-Air Air Compressor Model 3 DK-9400 3-1,5 Lab - Spares / Repairs
ITEM-23974 GBC Docubind P300 Electric Punch Comb Binding System
ITEM-17107 Kern Model 3000-2 Precision Laboratory Balance Scales Lab
ITEM-38089 Hp Envy Pro 6430 Printer
ITEM-41793 Axygen Plate Centrifuge
ITEM-41799 Ohaus Scout
ITEM-41812 Thermo Scientific Drybath stdrd 2 black
ITEM-41814 2 x Zebra GX430t
ITEM-41816 Job Lot of Mixed Scanners
ITEM-41818 CZUR Scanner
ITEM-38184 Hacona C-320 Heat Sealer & Bags
ITEM-38182 2 x Smart-UPS SC 420 Power Supply
ITEM-30013 Olympus CT-5 Centering Eyepiece
ITEM-37531 Grant-Bio PMS-1000 Platform Shaker Lab
ITEM-38180 2 x APC Smart-UPS 750
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Fisher Scientific Isotemp Recirculating Chiller Lab Spares/Repairs
ITEM-41106
Fisher Scientific Isotemp Recirculating Chiller
This was removed from a university lab where it was surplus to requirements.
The unit powers up but the lab confirmed it was not pumping correctly, and therefore not cooling correctly prior to collection.
It is sold for spares/repairs.
£ 500.00 (ex. VAT) 1 in stock
Sigma 2-16P Centrifuge with Nr.12148 15300/min Rotor Lab
ITEM-28148
This Sigma 2-16P Centrifuge with Nr.12148 15300/min Rotor was removed from a university lab where it was surplus to requirements.
The unit powers up and is in full working order. It does begin to whistle above 10000rpm, but we believe this is just down to the lid seal.
It has had new lid struts fitted and new QR lid release plugs.
With it is a Sigma Nr.12148 15300/min Centrifuge Rotor.
Good used condition.
Measures:
Approx 17cm.
Centre bore: 10.8mm.
Tube holes: 10.8 x 36.2mm.
24 sample holes.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf Refrigerated Centrifuge 5804 R Lab Spares/Repairs
ITEM-41484
Eppendorf Refrigerated Centrifuge 5804 R Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on, therefore we are unable to test it further, and it is listed as Spares/Repair.
The control board is faulty, and is loose inside the chamber.
There is no rotor.
£ 500.00 (ex. VAT) 1 in stock
Waters Source Ion Guide A Part Number 700004952 for Xevo Lab
ITEM-31721
Waters Source Ion Guide A Part Number 700004952
This was removed from a university lab where it was surplus to requirements.
The unit is boxed but not sealed. We are unsure if it has been used.
It comes boxed with a Certificate of Conformity
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Pair of Horizon Collators MC-8 MC-8a and MC-8m Spares/Repairs
ITEM-41141
Pair of Horizon Collators MC-8 MC-8a and MC-8m
These were removed from a university lab where they were surplus to requirements.
Bot units are in reasonably good cosmetic condition and power on, but due to sustained damage, they are not fully operable and therefore, listed as Spares/Repair.
The damage sustained is as follows:
Part 1:
The front intake has completely broken off, with the back tray significantly buckled.
Part 2:
The rear of the device has sustained severe damage or deformation as a result of mishandling or being dropped.
The plugs have since been removed after testing the 32AMP.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Job Lot of Mixed Benchtop Lab Equipment - Hoefer, Hybaid, Jenway
ITEM-38981
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
ITEM-36591 Hybaid Maxi 14 Rotisserie Hybridisation Oven
ITEM-36595 Hybaid Shake 'n' Stack Hybridisation Oven [condition: Used]
ITEM-36596 Fisherbrand HU10 Mini-Plus Horizontal Gel Electrophoresis Unit [condition: Used]
ITEM-36597 Hoefer Electrophoresis Unit [condition: Used]
ITEM-36598 Hoefer Electrophoresis Unit [condition: Used]
ITEM-36599 Luckham 4RT Rocking Table [condition: Used]
ITEM-36607 UVP Transilluminator [condition: Used]
ITEM-36608 Compaq TFT7010 Monitor [condition: Used]
ITEM-36609 Thermo Hybaid PCR Express With Spare PCR Block [condition: Used]
ITEM-39835 Hanna Instruments Water Test
ITEM-39836 Jenway 9200 DO2 Meter
ITEM-39766 Extech 407510 Heavy Duty Dissolved Oxygen Meter
ITEM-39767 Job lot of Hanna Instruments Pocket PH Meters
ITEM-38983 FluidX Xcap Microplate capper [condition: Used]
ITEM-23169 Small desk fan SFE/1 [condition: Used]
ITEM-39770 Hybaid PCR Express
ITEM-39771 MJ Research PTC-225 Thermal Cycler
ITEM-39772 Grant W6 Sonic Bath
ITEM-37438 CBS Scientific EPS-300 X Power supply [condition: Used]
ITEM-37439 SS 3H Hotplate Stirrer [condition: Used]
ITEM-39774 Spectra Physics SP8480XR Scanning Detector
ITEM-39775 Tyco Electronics LVC2KW Power Supply
ITEM-39776 GS Laboratories 6593-10 CO2 Control Backup System Lab
ITEM-39777 Spectra System AS3000
ITEM-39778 Test Tubes w/ Holding Rack
ITEM-39779 Perkin Elmer L226-0103 Model LC-240
ITEM-39101 Vevor Rolling Mill [condition: Used]
ITEM-37443 Jenway 1000 Hotplate Stirrer [condition: Used]
ITEM-39782 Pyrex 20L Flask
ITEM-39783 Zippette Flask and Dispenser
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Miele Professional Dishwasher GG05 Spares/Repairs
ITEM-24741
Miele Professional Dishwasher GG05
This was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested. The inlet pressure is sufficient, the filter has been checked, cleaned and the propeller adjusted but shows an error 404 message which indicates there is an inlet issue.
It is sold for spares/repairs as it needs a new inlet.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Job Lot of Mixed Benchtop Lab Equipment - ALA, NTC, Kinetrol, Olympus, Jencons
ITEM-41522
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
ITEM-21726 NTC auto Cylinder change over unit
ITEM-21717 Hi Lo 300 bar Inlet
ITEM-21719 Freshford 300 bar Inet
ITEM-21730 ALA Scientific Valve Commander
ITEM-28014 Chemical Spill Kit
ITEM-28015 Chemical Spill kit
ITEM-28013 Box of Polythene heavy duty bags 150 x 200mm
ITEM-30114 1,000 ml volumetric flasks
ITEM-30115 1,000 ml volumetric flasks
ITEM-30112 Box of miScript miRNA PCR arrays
ITEM-25739 Imperial Saucepan
ITEM-25696 2x Ribbon Cables (parcel)
ITEM-25692 Huntingdon Animal Blood Pressure Monitor
ITEM-25700 2x Denley Aluminium vial stands
ITEM-28026 Jencons Heated Stirrer
ITEM-25695 Mini Centrifuge Rotor Lid
ITEM-28007 Adjustable microscope stage centre
ITEM-25743 CamLab UV Lamp CAMAG
ITEM-25712 Olympus Highlight 3100
ITEM-27671 Carl Zeiss Mixed Parts
ITEM-28025 Greiner Bio one box 9pks of 10. 384 well microplates small Vol
ITEM-25701 HPLC Blockheater w/ manual
ITEM-25690 Watson A.C. Volt Gauge
ITEM-25747 Box of 3 prong retort clamps
ITEM-25706 Waste container
ITEM-27660 Laboratory Stand
ITEM-28021 Spillage Absorption kit
ITEM-28020 Spillage Absorption kit
ITEM-28019 Spillage absorption kit
ITEM-28018 Spillage absorption granules
ITEM-28022 STEM Corp Block Heater
ITEM-28024 Jencons Light box
ITEM-27666 Heat Resistant Stove Glass & accessories
ITEM-25717 Olympus Light source
ITEM-25713 Olympus Highlight 3100
ITEM-27662 Mixed Glass & accessories
ITEM-25738 Helena Electrophoresis GEL Tank
ITEM-27379 3 bits of Glassware
ITEM-25697 Box of HPLC Misc bits
ITEM-25709 Kinetrol 1/4 turn Actuator
ITEM-25736 Red Desk Lamp
ITEM-25684 4x Beckman Coulter Centrifuge bucket lids
ITEM-25704 5x Beckman Coulter plastic compartments
ITEM-27673 Bio Rad Econo Recorder
ITEM-28027 Spill Kit
ITEM-27380 Box of small glassware
ITEM-30090 Image Transfer Foiling
ITEM-30104 Bosch Interferenz 5
ITEM-30106 T8 240V/20W UV blacklight
ITEM-30096 Toshiba DVD player
ITEM-30102 EMS Combination 850
ITEM-30098 Bio Rad Variable Speed Pump
ITEM-30077 ScotLab Electrophoresis Power Supply SL-3656
ITEM-30101 Bio Rad Model 200/2.0 Power Supply
ITEM-30093 EMS Suction Unit
ITEM-30085 Life Tech vertical electrophoresis apparatus
ITEM-30087 Charles Austen DA7C Pump
ITEM-30078 Koch-Light LTD electrophoresis tank
ITEM-30105 Samsung 32" monitor
ITEM-30100 Huntleigh Flowtron Plus
ITEM-30095 EMS HI-Q applicator & wires
ITEM-30091 IKA MS2 Minishaker
ITEM-30099 Bio Rad Variable Speed Pump
ITEM-30103 MIE transducer controller
ITEM-30097 Unknown metal components
ITEM-30094 Biofeedback EMG100
ITEM-30086 Bio Rad Gel Dryer 583
ITEM-30092 Bowens mosaic limelite
ITEM-30088 Edwards thermocouple 507
ITEM-27907 Vickers Instruments Microscope
ITEM-27913 Vickers Instruments Microscope
ITEM-27912 Vickers Instruments Microscope
ITEM-27911 Vickers Instruments Microscope
ITEM-27910 Vickers Instruments Microscope
ITEM-27909 Vickers Instruments Microscope
ITEM-27908 Vickers Instruments Microscope
ITEM-30040 Unbranded Microscope
ITEM-30144 Glass vials
ITEM-30039 Leybold Didactic Microscope
ITEM-30035 Leybold Didactic Microscope
ITEM-30038 Leybold Didactic Microscope
ITEM-30037 Leybold Didactic Microscope
ITEM-30042 Unbranded Microscope
ITEM-26095 Techne MCS-104S
ITEM-30081 Whatman thin layer chromatography plates
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Pallet of Lab Equipment, Thermal Cycler, Oxygen Meter, Oscillator, Balance etc
ITEM-37601
Multi Job Lot Mixed Items
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle and further investment in each individual product may be required. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
Included are;
ITEM-35225 Mareno 3000 Induction Hob
ITEM-35204 Alpha Innotech TM-26 UV Transilluminator Lab Equipment
ITEM-35292 Buchi Rotavapor R II R-II Rotary Evaporator
ITEM-30017 Kent Scientific Isometric Transducer Lab
ITEM-35279 Mettler AT200 Precision Balance
ITEM-35191 Razel A-99 Variable Speed Syringe Pump
ITEM-38692 YSI Model 95 Dissolved Oxygen Meter with Probe
ITEM-37912 YSI 550 DO Handheld Dissolved Oxygen Meter With Probe
ITEM-37913 YSI 55 Handheld Dissolved Oxygen Meter With Probe
ITEM-35198 Thermo Scientific Multidrop 384 Type 832 Microplate Dispenser Lab
ITEM-29975 Pack of 5 - Edwards Odour Elements for EMF20 Oil Mist Filter 22304077
ITEM-35298 Carl Zeiss HBO 100 W VHC 100W Lamp Power Supply
ITEM-29970 Taylor-Wharton 10LD Liquid Nitrogen Dewar Tank Lab
ITEM-15840 Sokkia / Sokkisha DT6 Digital Theodolite Level for Surveying & Setting Lab
ITEM-17222 Marconi Instruments LTD Oscillator TF1247
ITEM-17268 Additive Layer Manufacturing RapMan 3 3D Printer BL-B
ITEM-35334 Thermo Scientific ARKTIK 5020 Thermal Cycler Dual Block Lab
ITEM-23962 Lot of 3 x 3M Digital Projectors - 2 x X40 and 1 x X66
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Panasonic MIR-554-PE Cooled Incubator Lab Spares/Repairs
ITEM-20210
This Panasonic MIR-554-PE Cooled Incubator was removed from a university lab where it was surplus to requirements.
The unit powers and incubates well, but has a faulty cooling system.
It is in otherwise good cosmetic condition with minor marks.
It is sold for spares/repairs
Interior dimensions:
D52cm x W64cm x H127cm
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Helix CTI-Cryogenics Compressor Model: SCW Part no: 8032211 Lab Spares/Repairs
ITEM-26078
This Helix CTI-Cryogenics Compressor Model: SCW Part no: 8032211 was removed from a university lab where it was surplus to requirements.
The item is in reasonable cosmetic condition but the front vent/panel is bent in one corner, preventing it from being secured. There are scratches and other marks along the surface and edges.
The unit does not power up and is sold for spares/repairs.
The absorber was last changed March 1997
Weight & dimensions are as follows:
L 52cm x W 50cm x H 42cm
75kg
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Revco Elite Plus Freezer Ultra Low Temperature ULT 2586-6-W48
ITEM-37570
Thermo Scientific Revco Elite Plus Freezer Ultra Low-Temperature ULT 2586
This was removed from a university lab where it was surplus to requirements.
The unit does not power on, therefore, it cannot be tested, and it's sold as spares or repairs.
It is in good cosmetic condition both internally and externally.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Job Lot of Mixed Benchtop Lab Equipment - Gilson, Cole, Bambi, Buchi, Parr
ITEM-41232
This job lot of items comes from a variety of university laboratories. The items were no longer required, collected from various store rooms and facilities.
None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.
ITEM-41003 Baskerville Autoclave Controller
ITEM-41004 Gilson 305 Pump
ITEM-41005 Gilson 305 Pump
ITEM-41006 Cole Parmer KDS-200-CE
ITEM-41007 Unbranded Voltmeter
ITEM-41008 Grant Water Bath
ITEM-41009 Bausch & Lomb Monochromator
ITEM-41010 Bausch & Lomb Monochromator
ITEM-41011 Vertical Injection unit
ITEM-41012 Carbolite MTF 10/15/130 PAT FAIL
ITEM-41013 JMBS Hercule 2000 Chromatography Interface
ITEM-41014 Parr 5000 Multi Reactor Heater System
ITEM-41015 Jasco BP-1580-81 Back Pressure Regulator
ITEM-41016 Vertical Injection Unit
ITEM-41017 Brooks instrument 0254
ITEM-41018 Parr Stand
ITEM-41019 Buchi Rotavapor RE121
ITEM-41020 Buchi Rotorvapor RE111
ITEM-39210 IGPD Powers Supply
ITEM-39211 PBF IGP-2X80W V2 Power Supply
ITEM-39212 Irish Plastic Binding Company Combi
ITEM-39213 Unbranded Control Unit
ITEM-37151 Agilent HPLC Plastic tray
ITEM-37157 Parr 5000 Series Multi Reactor Stirrer System
ITEM-39220 Bambi Air Compressor no motor
ITEM-26895 Buchi Evaporator
ITEM-41265 Microtec Fibre Optics MFO-90 w/ Stand
ITEM-39225 Kaiser slimlite lightbox
ITEM-41270 2x Schott Gooseneck Light 170 202
ITEM-41271 Metal Stage
ITEM-41273 1x Scanner and Multiple Probes/wires
ITEM-41274 Zebra Thermal Label Printer and Covers
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MCO-20AIC CO2 Incubator Lab Spares/Repairs
ITEM-40000
Sanyo MCO-20AIC CO2
This was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and powers up, it has been tested with a digital thermometer (not included).
The current CO2 Pump failed during testing and will require a new one to be fitted.
Therefore, it is listed as Spares/Repair.
£ 500.00 (ex. VAT) 1 in stock
Jouan B4i Bench-Top Lab Centrifuge 14000rpm + Tube Rotor Lab
ITEM-11932
This unit was removed from a lab as surplus to requirements.
At our site, we tested it and it ran up to 14,000 rpm smoothly.
We have not tested the unit any further.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo MDF-U73V Ultra Low Temperature Freezer Spares/Repairs Lab
ITEM-35616
This Sanyo MDF-U73V Ultra Low Temperature Freezer was removed from a university lab where it was surplus to requirements.
This item is in good cosmetic condition both internally and externally.
When the freezer is turned on, an alarm will sound indicating an error that hinders its cooling function. This issue may be caused by a defective compressor, which is why the product is sold as Spares/Repairs.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Wheaton 753680-2 Reach In Incubator Lab Spares/Repairs
ITEM-39203
Wheaton 753680-2 Reach In Incubator
This was removed from a university lab where it was surplus to requirements.
The unit powers up but would not heat up further than 35˚C. It is sold for spares/repairs.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
VWR 1927 Reach-In Dry C02 Incubator Lab Spares/Repairs
ITEM-39202
VWR 1927 Reach-In Dry C02 Incubator
This was removed from a university lab where it was surplus to requirement.
The unit initially powered up and worked to 35˚C only, but now will not power up due to a faulty switch.
The top panel is missing.
It is sold for spares/repairs
Items 1951 to 2000 of 3190