All Products
Items 1261 to 1280 of 3199

£ 170.70 (ex. VAT) 1 in stock
Flux Instruments Rheos 4000 HPLC Pump Lab
ITEM-09449
This unit was removed from a lab as surplus to requirements and we were assured the unit was in working order prior to removal from the lab
However, we have only tested it to power-on ourselves.
Therefore we are happy to sell the unit on the basis that it is in working order, and if you encounter any problems we can offer a 90-day return to base warranty.
Within the UK, we will also arrange the return postage so you are not out of pocket if a problem does arise with the unit.

£ POA 1 in stock
Forma Scientific 420 Incubator Orbital Tabletop Shaker Lab
ITEM-18914
This Forma Scientific 420 Incubator Orbital Tabletop Shaker was removed from a university lab where it was surplus to requirements.
The unit powers up but "Power Fault" flashes on the screen on boot. The shaker moves but it doesn't get noticeably faster as you increase the controller speed. The unit doesn't seem to heat up either. Our thermometer measured 15.8˚C when the unit was supposed to be outputting 65˚C.
It is in reasonably good cosmetic condition with marks from use.
It is sold for spares or repairs due to the faulty incubator.

£ POA 2 in stock
Formaflow System Formonia Formalin Handler & Neutralizer Model VAP3/3T Lab
ITEM-19329
This Formaflow System was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition but has some marks from use.
It powers up fine but has not been tested further.
Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving before it is shipped, we would be happy to provide this.

£ POA 1 in stock
Fotodyne Incorporated 3-3002 UV Transilluminator with Shield Lab
ITEM-18513
This Fotodyne Incorporated 3-3002 UV Transilluminator with Shield was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested with a UV meter. It read 580 Lumens. Only 4 bulbs are working, it seems like there should be one extra turned on. It is in reasonably good cosmetic condition but has some marks from use.

£ 6,530.83 (ex. VAT) 1 in stock
Fourne Maschinebau KS 33 Fibre Spinning System
ITEM-11958
This system was removed from a university lab as surplus to requirements.
It was ordered new for 64,000 EUR, commissioned on site, but unfortunately the project fell through and the system was never used. IT is complete with all original parts.
You are welcome to view the system and please feel free to ask any questions.

£ 1,360.58 (ex. VAT) 1 in stock
FP5 Pneumatic Press + FP1 MAS tooling, Elite Engineering Lab
ITEM-09146
This unit was removed from a university engineering lab as surplus to requirements.
At our site we have not tested it but we were assured it was in full working order when last used.
The unit cost £10k when originally purchased by the university.

£ 294.43 (ex. VAT) 1 in stock
Franklin Electric / Alcatel Vacuum Pump Model: 1101006401
ITEM-12928
Franklin Electric / Alcatel Vacuum Pump Model: 1101006401
This pump originated in a Lab in a top UK University and came to us as part of a Lab clear out.

£ 64.31 (ex. VAT) 1 in stock
FSA Laboratory Supplies WhirliMixer Vortex Shaker / Mixer Lab
ITEM-17871
This FSA Laboratory Supplies WhirliMixer was removed from a university lab where it was surplus to requirements.
The unit is in reasonable cosmetic condition with marks from use. The feet also no longer stick to the tabletop, causing it to move around the table when at high speeds.
The 'On' mode appears to run as it should but the speed control might not be quite as sensitive as it was when it was new. The 'Auto' setting does work, but the switch needs a fair amount of pressure to activate.

£ 799.38 (ex. VAT) 1 in stock
Fujifilm Fluorescent Image Analyser Model FLA-5000 System Lab + Software
ITEM-09007
This Fujifilm Fluorescent Image Analyser Model FLA-5000 System was removed from a university lab where it was surplus to requirements.
Included in the system is;
Fujifilm FLA 5000 - Powers on and is in good condition.
Raytek Image plate eraser III - Powers on and is in good condition.
Neither of the units have been tested further.
Manuals for both machines.
XP PC with software, user data erased.
- Image reader FLA 5000 Series V 1.0
- Aida Image Analyser V.3.11
- Connected main machine to PC and software acknowledged the connection.
3 x FLA Multistage 4046 all looks to be in slight disrepair.
Spare filter tray
Connecting wires
Please note that there is no monitor included. We used our own to test it.

£ 8,958.61 (ex. VAT) 1 in stock
Full Size Wind Tunnel Aeronautical Engineering Testing System 10M Long
ITEM-12358
This system is being removed from a leading UK university engineering department as it is no longer required.
It is in full working order.
- This tunnel was originally constructed at Imperial College London.
- The tunnel has four working sections of different size.
- The motor and control system were replaced at about 4 years ago.

£ POA 1 in stock
Furzehill Laboratories Ltd High Dissipation Resistance Box Lab
ITEM-18308
This Furzehill Laboratories Ltd High Dissipation Resistance Box was removed from a university lab where it was surplus to requirements.
It has not been tested at all.
It is in reasonable cosmetic condition but all the knobs are missing.

£ POA 1 in stock
G-Storm GS1 Gradient PCR Thermal Cycler Lab Spares/Repairs
ITEM-19548
This G-Storm GS1 Gradient PCR Thermal Cycler was removed from a university lab where it was surplus to requirements.
The unit powers up and the touch screen is functional but will not heat up. Some of the menus are password-protected, but we have the passwords.
It is in good cosmetic condition but has some slight marks from use.
The block has 96 wells.

£ 149.31 (ex. VAT) 1 in stock
G-Storm GT-10770 PCR Gradient Thermal Cycler Spares / Repairs
ITEM-15432
This G-Storm GT-10770 PCR Gradient Thermal Cycler was removed from a university where it was surplus to requirements.
The unit powers up but the screen stays lit White with no options or text. It does not show any start up screen at all. We were not able to test any further.
The unit is in good, used cosmetic condition but does have marks and signs of use.
Unit is sold as spares / repairs.

£ POA 1 in stock
G-Storm PCR Thermal Cycler Model: GS0001 Lab Spares/Repairs
ITEM-20122
This G-Storm PCR Thermal Cycler Model: GS0001 was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition though it has slight sticker residue, along with some minor scratches and dents on the sides. The interior is mainly clean, but the lid has some stains. The lid can be stiff to open, but it closes and locks closes fine.
It initially booted up without issue, and we were able to access the different menus. Some menus are password locked but we have the passwords.
We attempted to test it but it would not respond and the screen went white. We were eventually able to access the menus after a few restarts and managed to run it up to 37˚C and 99˚C.
We think it may be faulty so it is sold for spares or repairs.

£ POA 1 in stock
G-Storm PCR Thermal Cycler Model: GS0001 with Stylus Lab
ITEM-20121
This G-Storm PCR Thermal Cycler Model: GS0001 with Stylus was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition though it has slight sticker residue, along with some minor scratches and dents on the sides. The interior is mainly clean, but the lid has some stains. The lid can be stiff to open, but it closes and locks closes fine.
It initially booted up without issue, and we were able to access the different menus. Some menus are password locked but we have the passwords.
We set the temperature at 37˚C, and it appeared to run fine before the unit crashed and became stuck in a loop of rebooting. Whilst the unit was rebooting the temperature still continued to climb.
We again set the temperature to 37˚C and the thermometer measured it as 36.7˚C.
We then set it to the maximum of 99˚C, which the thermometer measured. 99.0˚C.
After rebooting several times the unit came back on and we were able to turn off the current cycle and restart it.
It is sold for spares/repairs as there appears to be a fault and it is quite temperamental.

£ 131.25 (ex. VAT) 1 in stock
Gage Technique LTD Miniature Strain Meter Typer GT1174 Lab
ITEM-15835
This Gage Technique LTD Miniature Strain Meter Typer GT1174 was removed from a university engineering department where it was surplus to requirements.
The unit powers on with 6 AA batteries (not included). It was not tested further.
It has lots of age-related marks on the panel and the wooden case has sustained damage. It is in good condition generally.

£ POA 1 in stock
GAITRite Electronic Walkway System MAP/CIR Inc with Software Lab
ITEM-17299
This GAITRite Electronic Walkway System MAP/CIR Inc with Software was removed from a university lab where it was surplus to requirements.
Everything powers up and the walkways were tested with the laptop and software provided. One of them seems to track fine, but the other seems to be uncalibrated.
The system consists of the following parts:
1 x Dell Latitude D520 Laptop, Intel Centrino Duo, Windows XP.
We were able to access it with the provided password (we will provide this if purchased).
There are such program files as: Adobe Acrobat Reader, CISCO NAC Agent, Speech Engines, Firebird, Foot scan schemes, Libra, Instruments, Technologies, manuals etc.
1 x Electronic Walkway
The unit powers up and seems to be in working order. It is in good cosmetic condition.
The unit comes with its own power supply and control block.
The walkway is 500x90cm LxW
1 x Electronic Walkway
The unit powers up and seems to be uncalibrated or broken. It is in good cosmetic condition.
The unit comes with its own power supply and control block.
The walkway is 500x90cm LxW
2 x Cases for the walkways

£ POA 1 in stock
Galaxy Audio Core PA5X140 Powered Hot Spot Monitor Wedge
ITEM-17911
This Galaxy Audio Core PA5X140 Powered Hot Spot Monitor Wedge was removed from a university AV department where it was surplus to requirements.
The unit powers up and the input worked during testing.
It is in very good cosmetic condition with very limited marks from use.

£ POA 1 in stock
Gallenkamp Economy Laboratory Incubator with Fan Size 1 Lab
ITEM-18888
This Gallenkamp Economy Laboratory Incubator with Fan Size 1 was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested with a digital thermometer (not included). The temperature took around 15 minutes to reach 37 degrees when set. It was then set to the maximum number on the dial of 80 degrees and it reached 73 degrees after running for 2 hours.
It is in reasonably poor cosmetic condition and is heavily stained. It doesn't however seem to affect the operation of the unit.
Inside dimensions:-
Depth - 36cm
Width - 48cm
Height - 33cm
1 Shelf - 48x31cm

£ POA 1 in stock
Gallenkamp Hotbox Laboratory Oven with Fan Size 2 Cat no. OVB 305 1100 Lab
ITEM-19445
This Gallenkamp Hotbox Laboratory Oven with Fan Size 2 was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested with a digital thermometer (not included). It was set to 100˚C and reached 70˚C. It was then set to the max of 200˚C and reached 160˚C.
It is in reasonably good cosmetic condition but has some marks from use.
Internal dimensions - D42 x W47 x H46cm
2 x Shelves: Top - 41 x 48cm. Bottom - 31 x 43cm
Items 1261 to 1280 of 3199