All Products
Items 1501 to 1550 of 3312
£ 1,000.00 (ex. VAT) 1 in stock
Styromelt Styrofoam Polystyrene Recycling Machine Spares/Repairs
ITEM-37260
Styromelt Styrofoam Furnace Machine
This item was removed from a university where it was surplus to requirements.
The unit powers on, but a locking mechanism fault prevents it from operating properly. The door has issues with locking and opening, requiring the unit to be turned on and off to unlock the door.
It is in good cosmetic condition externally, and poor internally from use.
Due to the noted faults, this item is listed as spares/repairs.
£ 1,000.00 (ex. VAT) 1 in stock
BioMat 2 Class ll Microbiological Safety Cabinet On Stand With Ducted Exhaust
ITEM-42261
BioMat 2 Class II Microbiological Safety Cabinet with Ducted Exhaust on Stand
This item was removed from a university where it was surplus to requirements.
The cabinet is in good cosmetic condition and includes a steel stand measuring 113 x 60 x 83 cm (w x d x h).
The unit powers up and is in good working order. A strong airflow was observed, and the inflow needle indicator reached the green safe zone during operation. Interior power sockets were tested and are functional. (Socket tester not included.)
It's been regularly serviced, with its most recent being on: 22.04.24
Specifications:
- Serial No.: MC5765/1
- Exhaust outlet: 20 cm diameter duct connection
- Formalin vaporiser external tank
Notes:
- The fan control button is missing its outer diaphragm, but is operational.
- No UV function included.
£ 1,000.00 (ex. VAT) 1 in stock
Hewlett Packard Cohesive Technologies 1100 Series G1310A Isocratic Pump Lab
ITEM-38345
This Hewlett Packard Cohesive Technologies 1100 Series G1310A Isocratic Pump was removed from a university lab where it was surplus to requirements.
The item is in good cosmetic condition and powered up, as seen the item is missing the front door panel.
We are unable to test this item further at our facility.
Power supply included.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Milestone Ethos plus 2 SEL Microwave Solvent Extraction Labstation Spares/Repair
ITEM-41135
Milestone Ethos plus 2 Microwave Solvent Extraction Labstation
This system was removed from a university where it was surplus to requirement.
All units are in good cosmetic condition, with the primary unit (Milestone Ethos plus 2) and PC Set-Up turning on, however, there is no power in the LabTerminal 800 Controller.
The system is sold for spares/repairs.
-1x Milestone Microwave Laboratory Systems LabTerminal 800 Controller
1x easywave chip card for the controller
S/N- 0205722
-2x Rotor' for microwave
- Relevant vessels and safety shields for rotors
-2x ATC-FO sensors for microwave
-2x Torque wrenches for rotor
-2x Extraction Pipes
1x Monitor (IIyama Prolite B2206WS) and Dell Tower Optiplex GX620
Includes: Pipette tracker v3.3 Software
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Malvern MSX Mastersizer Particle Size Analyser - DIF 2000 Lab Spares/Repairs
ITEM-25084
This Malvern MSX Mastersizer Particle Size Analysis System was removed from a university lab where it was surplus to requirements. The lab reported it had not been used for a number of years, but was working when they last used it.
The unit will likely require significant refurbishment, and for that reason it is sold for spares/repairs.
Included are;
1 x Malvern Particle Size Analysis Unit
Model MSX
The unit powers on and is in good cosmetic condition.
1 x Malvern Small Volume Sample Presentation Unit.
DIF 2000
The unit powers on and is in good cosmetic condition. It's in working order.
Accessories:
1x Laser enable key (850)
1x Malvern chamber Rittal key
1x Case strap
2x Case keys
3x Lenses
1x 45mm
1x300mm
1x pinhole
All lenses appear to be in good cosmetic condition.
Lens caps:
3x 67mm
1x 58mm
1x 46mm
1x 30ml clear plastic bottle (empty)
6x Clear tubing (various lengths)
4x Allen keys (various sizes)
2x wooden focal cassettes
2x cotton buds
1x Glass cassette
1x Metal arm/leaver (32908-29)
1x T1A 250v quick blow fuse
Floppy discs
12x Microsoft software
6x Malvern software
1 x Fast internet Access Supra Install CD
1x Supra Express Manual
4x User Manuals:
The units are in good cosmetic condition. It is unclear if there is missing information from the manuals as some folders contain loose papers.
£ 1,000.00 (ex. VAT) 1 in stock
Leica Leitz Labovert FS Microscope With Leica 12V/100W Power Supply Lab
ITEM-44879
Leica Leitz Labovert FS Microscope With Leica 12V/100W Power Supply Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and in working order.
This microscope features the following components;
Leica 12V/100W Power Supply
4 x Objectives:
- Modulation optics inc HMC 20 LWD 0.4NA 160/0-2 Objective
- Modulation optics inc Hoffman modulation contrast HMC EF 10x 0.25na 160/- objective
- Leica 160/- EF 4/0.12 objective
- Modulation optics inc HMC 40 LWD 0.5NA 160/0-2 objective
2 x Eyepiece:
- Leitz Periplan GF 10x/20 M Lense
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
New Brunswick Innova 4330 Incubator Shaker Lab Spares/Repairs
ITEM-40991
This New Brunswick Innova 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.
The unit powers up but does not shake. The heating and cooling functions work.
It is in reasonably good cosmetic condition with minor marks.
£ 1,000.00 (ex. VAT) 1 in stock
Carl Zeiss Jenamed 2 w/ 5 x Objectives Apochromat, Planachromat Lab
ITEM-37539
This Nikon Optiphot-2 Microscope was removed from a university lab where it was surplus to requirements.
The unit powers up and all the objectives appear to focus well. It is in good cosmetic condition.
There are 5 x Objectives included, and they are as follows;
Apochromat 50x/0,95 ∞/0,17-A
Apochromat HI100x/1,40 ∞/0,17-A
Apochromat 25x/0.65 ∞/0,17-A
Apochromat 12,5x/0,35 ∞/0,17-A
GF Planachromat 40x/0.65 ∞/0.17-A
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
HT Infors Multitron Triple Stack Incubator with Humidity and CO2 Lab Faulty
ITEM-45145
HT Infors Multitron II Triple Stack Shaking Incubator
This system was removed from a university laboratory where it was surplus to requirements.
The incubator units are in reasonably good cosmetic condition, showing signs of general use, with some marks.
The working condition of each unit is stated below.
Top and Middle Units: Operational except for faulty CO₂ sensors. Replacement sensors (GMP251) are recommended.
Bottom Unit: Requires replacement of blower motors and rear cooling fan for full operation.
The throw of the shaker plate could not be determined; however, the middle and top units operated reliably at 250 rpm.
Due to the above listed faults regarding all units, this incubator system is listed as Spares/Repair.
Includes:
- Triple-stack shaking incubators with top and middle units operational
- CO₂ control with Vaisala GMP221 sensor (replacement model: GMP251 recommended)
- Triple-stacked configuration with CO₂ and humidity features
Model: Multitron II
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) No longer available
INDENTEC Hardness Testing Machine 5030SKV Lab Spares/Repairs
ITEM-34831
INDENTEC Hardness Testing Machine Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, however it displays the following error: Check Lead which prevents further use.
It is listed as Spares/Repair.
Also included:
Calibration Certificate
User Manual
Optic Head
£ 1,000.00 (ex. VAT) 1 in stock
Buchi K-350 Distillation Unit Lab
ITEM-44755
Buchi K-350 Distillation Unit Lab
This item was removed from a university lab where it was surplus to requirements.
It is n good cosmetic condition and powers on, we are unable to test it further at our facility.
£ 1,000.00 (ex. VAT) No longer available
MAT BioMAT 2 Microbiological Safety Cabinet Class 2 II Lab
ITEM-31179
MAT Medical Air Technology BioMAT 2 Class 2 Microbiological Safety Cabinet
This was removed from a university lab where it was surplus to requirements.
The item powers on with airflow and both UV and white lights working.
It is in good cosmetic condition with some marks from use.
Cabinet Dimensions - L120 W63 141cm
Frame Dimensions - L112 W60 H84cm
Internal workspace dimensions - D54 W106 H70cm
£ 1,000.00 (ex. VAT) 1 in stock
Syngene Ingenius 3 Gel Documentation System Lab
ITEM-45429
Syngene InGenius 3 Gel Documentation System
This system was removed from a university where it was surplus to requirements.
The system powers on and is in good cosmetic condition.
Both UV and white light are functional, and the door UV safety features operate as expected.
Specifications:
- Model: InGenius 3
- Serial No.: IG3/1258
Included:
- Syngene Illuminator
- Serial No.: 5220097201504
£ 1,000.00 (ex. VAT) No longer available
Beckman Coulter SW 32 Ti Swinging Bucket Rotor For Centrifuge Lab
ITEM-39148
This Beckman Coulter SW 32 Ti Swinging Bucket Rotor was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition but has not been tested. It will need to be inspected for safety by a qualified engineer before it can be used.
Capacity: 6 x 100ml
Max RPM: 32,000
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Leitz Dialux 22 Fluorescence Microscope With Camera + Control Unit Lab Faulty
ITEM-39087
Leitz Dialux 22 Fluorescence Microscope with Camera + Control Unit
This system was removed from a university lab where it was surplus to requirements.
The unit does not power up. We have tested the continuity and found no issues, but we are unable to find the cause of the issue. The power supply for the lamp is a visual PAT test fail due to exposed wires and also does not power the lamp.
Due to the faults listed above, this system is listed as Spares/Repair.
The system comprises the following:
- Leitz Vario Orthomat Controller
- Leitz Power Supply for Lamp
- Leitz Vario Orthomat 2 Camera
- Leitz Wetzlar 100W Lamp (Type: 307-143.003)
5 x Objectives:
- NPL Fluotar 6.3/0.20
- NPL Fluotar 16/0.45
- NPL Fluotar 40/0.70
- Leitz EF 63/0.85
- Leitz PL 2.5/0.08
2 x Leitz Eyepieces Periplan GW 10x M
Model: Dialux 22
£ 990.00 (ex. VAT) 1 in stock
Dionex UVD 340S UV/VIS Detector Lab
ITEM-38364
Dionex UVD 340S UV/VIS Detector
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in good cosmetic condition but is missing a rear foot.
£ 990.00 (ex. VAT) 1 in stock
C.B.S Scientific Optimizer PCR Workstation Lab
ITEM-36000
C.B.S Scientific Optimizer PCR Workstation
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in good cosmetic condition with minor marks.
Includes:
-GE fluorescent light
-GE Germicidal lamp
£ 990.00 (ex. VAT) 1 in stock
Piramoon Technologies F15-6x100 FiberLite 15,000rpm 24,700g Centrifuge Rotor Lab
ITEM-35716
Piramoon Technologies FiberLite F15-6x100 15,000rpm 24,700g Centrifuge Rotor
This was removed from a university lab where it was surplus to requirements.
The item is in very good cosmetic condition and also includes its original carry case.
Items features are as follows:
15000rpm
24,700 X G
6x 100ml tube holders
Quick release autolock
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 990.00 (ex. VAT) 1 in stock
PEAK Scientific PH600 Precision Hydrogen Generator Lab
ITEM-34765
PEAK Scientific PH600 Precision Hydrogen Generator
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further.
It is in good cosmetic condition with marks from use.
It is sold for spares/repairs due to the nature of the instrument and that it is untested.
£ 990.00 (ex. VAT) 1 in stock
Anglia Scientific Cryotome Model 0600 Cryostat Lab
ITEM-39085
Anglia Scientific Cryotome Model 0600 Cryostat
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in working order. It is in reasonable cosmetic condition with minor marks.
(digital thermometer not included).
Model- 0600
S/N- 9002459
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 985.00 (ex. VAT) 1 in stock
Thermoplan Black & White 3 CTM-RF Fully Automatic Coffee Machine Spares/Repairs
ITEM-36515
Thermoplan Black & White 3 CTM-RF Fully Automatic Coffee Machine Spares/Repairs
This was removed from a university pub where it was surplus to requirements.
The unit powers up but we were unable to test it further. The grounds drawer is missing.
The university confirmed that it may have some issues, and it has some superficial damage, but it could be refurbished.
It is sold for spares/repairs as we are fairly sure it will have issues.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 985.00 (ex. VAT) 1 in stock
Lab Companion IS-971R Shaking Incubator Lab Cooling Fault
ITEM-39716
Lab Companion IS-971R Shaking Incubator
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has a cooling fault. It is seemingly in otherwise working condition.
It is in good cosmetic condition with minor marks
It is sold for spares/repairs.
£ 985.00 (ex. VAT) 1 in stock
Vickers-Armstrong Pedestal Hardness Tester Lab
ITEM-37040
Vickers-Armstrong Pedestal Hardness Tester
This was removed from a university lab where it was surplus to requirements.
The unit is in reasonably good cosmetic condition with marks from use.
The system is mechanically sound, but we were told by the lab that the diamond might be damaged. We have been unable to confirm or deny this.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 980.00 (ex. VAT) 1 in stock
PEAK Scientific Hydrogen Generator PH600
ITEM-34766
PEAK Scientific PH600 Precision Hydrogen Generator
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further.
It is in good cosmetic condition with marks from use.
It is sold for spares/repairs due to the nature of the instrument and that it is untested.
£ 980.00 (ex. VAT) 1 in stock
Tecan Freedom EVO-2 100 Base Software
ITEM-26381
Tecan Freedom EVO-2 100 Base Software
This was removed from a university lab where it was surplus to requirements.
Contains the following:
Tecan Instrument Software Version 6.1 SP1
Operating Manual Freedom EVO
Swiss Tools PB 6205: 0.71 x 40
Swiss Tools PB 140/2 : 0.6 x 4 x 40
Mini flat head screw driver
Allen key tool
£ 975.00 (ex. VAT) 1 in stock
GE Healthcare Wave Bioreactor System 2/10 EH Lab
ITEM-31129
GE Healthcare Wave Bioreactor System 2/10 EH
This was removed from a lab where it was surplus to requirements.
All units power on, and with the rocker working, the temperature rises when weight is put on the sensor. The lab confirmed it was working prior to removal.
There is nothing to connect the CO2MIX unit to the main part. There is no PSU. It was tested with one from another item.
It is comprised of 5 parts.
Wave Bioreactor System 2/10 EH
Cat no. 28937786
SN - 1590291
with Wave KIT2EH (48 x 30cm)
Cat no. 28411541
SN - 1589190
Wave PERFCONTE2E
Cat no. 28984913
SN - 1590245
Wave CO2MIX20
Cat no. 28937795
SN - 1571083
Filter Heater
PN - 28411639
SN - 2498371
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 975.00 (ex. VAT) 1 in stock
Revco Habitat CO2 Water Jacketed Incubator Model no. RCO3500TWBB Lab
ITEM-28101
This Revco Habitat CO2 Water Jacketed Incubator Model no. RCO3500TWBB was removed from a university lab where it was surplus to requirements.
The unit has been fully tested and recertified by a qualified service engineer. The report is available on request if you would like to see it.
The unit has a water jacket that will require a top-up on installation. The unit will require 8-10 hours to stabilise once installed.
It is in excellent cosmetic condition with some minor marks from use.
4 Shelves - 49.5 x 49.5cm
Internal dimensions - D52 W50 H55cm
£ 975.00 (ex. VAT) 1 in stock
S&M CAHN 28 Automatic Electro Microbalance Model 10028E Lab
ITEM-20190
This S&M CAHN 28 Automatic Electro Microbalance Model 10028E was removed from a university lab where it was surplus to requirements.
The unit powers up but the lamp is not working. E3 appears on the screen when pressing the CAL button. Placing weights on the scales generates numbers but they do not match the weights placed. It probably needs some sort of calibration. It was not tested further.
£ 970.00 (ex. VAT) 1 in stock
Secomam UVIKON XS UV/VIS Spectrometer Lab
ITEM-35697
This Secomam UVIKON XS UV/VIS Spectrometer was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further at our facility.
It is in good cosmetic condition with minor marks from use.
£ 965.00 (ex. VAT) 1 in stock
Julabo SE High Tech Heating Circulator Water Bath Lab
ITEM-38834
Julabo SE High Tech Heating Circulator Water Bath
This was removed from a university lab where it was surplus to requirements.
The unit is in good working order but is missing the plug for the drain, which will need to be replaced before it can be used. We rerouted the water with a hose for testing.
It is in good cosmetic condition with minor marks.
£ 965.00 (ex. VAT) 1 in stock
Thomson DuraTRUE 115 Linear Micron Gear Motor Ratio:250:1 Y-Axis
ITEM-30594
Thomson Linear Micron DuraTRUE 115 Gear Motor Ratio:250:1 X-Axis
This was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition with marks from use but has not been tested.
£ 965.00 (ex. VAT) No longer available
Jenway Flame Photometer PFP7 Lab
ITEM-25022
This Jenway Flame Photometer PFP7 was removed from a university lab where it was surplus to requirements
The unit powers up but has not been tested at our facility.
It is in reasonably good cosmetic condition with minor marks from use.
£ 960.00 (ex. VAT) 1 in stock
Lot of Thermo Scientific Rotor Bucket Adapters & Lids TX-750 T-25 T-75 Lab
ITEM-38715
Lot of Thermo Scientific Rotor Bucket Adapters & Lids
All items look to be new and unused, but a lot of the packaging has been opened so we cannot confirm this. We removed the packaging for the photos.
Included are the following:
Thermo Scientific TX-750 Round Bucket Adapters x 2
Part#: 75003638
Thermo Scientific Adapters for T-25 Nunc Easy Flask x 2
Part#: 75008384
Thermo Scientific Adapters for T-75 Nunc Easy Flask x 2
Part#: 75008383
Thermo Scientific Centrifuge Rotor Bucket Adapters 21x15mL x 4
Part#: 75003719
Thermo Scientific TX-750 Swinging Bucket Rotor Lid x 2
Part#: 75003609
Thermo Scientific Carriers for microplates and T-75 Flasks for TX-750 rotor x 4
Part#: 75003617
£ 960.00 (ex. VAT) 1 in stock
Jun-Air 2000-40MD2 Silent Air Laboratory Compressor Lab
ITEM-36663
This Jun-Air 2000-40MD2 Compressor was removed from a university lab where it was surplus to requirements.
The unit powers up and is in working order. The item is in a reasonable, used cosmetic condition. There is some damage in the top right of the unit.
Hours - 11134 71
£ 960.00 (ex. VAT) 1 in stock
G-STORM Thermal Cycler GS00482 Lab
ITEM-35590
This G-STORM Thermal Cycler GS00482 was removed from a university lab where it was surplus to requirements.
The unit powers up and is in full working order.
It is in good cosmetic condition with minor marks.
It has a 2 block cylinder with 48 wells in each block
£ 960.00 (ex. VAT) 1 in stock
BIGNEAT F3-XIT BPXS03/01A Safety Cabinet Powder Weighing Station Lab
ITEM-34875
BIGNEAT F3-XIT BPXS03/01A Safety Cabinet Powder Weighing Station
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in full working order. It is in good cosmetic condition with marks from use.
NEW ITEM
NEW ITEM
£ 955.00 (ex. VAT) 1 in stock
Micromass Capillary CE Assy Kit M955420CC1-S for Waters Xevo Lab
ITEM-31722
Micromass Capillary CE Assy Kit M955420CC1-S
This was removed from a university lab where it was surplus to requirements.
Everything is boxed and the consumables are sealed.
Included are;
Micromass Capillary Electrophoresis/Electrochromatography Sprayer Users Guide
Parts:-
Probe Cover M955510BD1
C.E HV Cable Assy M955515BC1
Earth Tag M955514AD1
Capillary M955423BD1
C.E Assembly Spares Kit M955420CC4:-
Cable Clamp M955513AD1
Plug Cap - Valco ZC1 6070233
1/16 Valco Ferrule 6070135
Ingertight Nut - Anachem F125 6070186
Circlip 6364907
Capillary M955423BD1
1.15 I/D x 1.00 C/S O-Ring 5711945
M2 Plain Washer 5331014
Alltech Peek Union 32141 6367402
1/4 - 1/16 Union 6070235
M3 x 4 ST/STL Grub Screw 5316005
1/16 Valco ZN1 Nut 6060806
Ceramic Capillary Cutter 6028630
Special Screw M955370AD1
Fill Port 6060919
Liner - Anachem F182X 6072209
Liner - Anachem F185X 6072210
1/8 - 1/16 PTFE Ferrule T1640357
M2 x 6 ST/STL CH HD Screw 5314050
BS109 Viton O-Ring 5711061
Upchurch F300 Nut & Ferrule 6367401
Microlight Union - Anachem P7 6072208
Fused Silica - TSP050192 6490519
PTFE Tube - TTF110 6063002
Fused Silica - TSP075375 6490512
Fused Silica - TSP075200 6490520
PTFE Tube - TTF115 6060743
Peek Tube - Orange 0.020 Bore 6436002
1/16 x 1mm Bore PTFE Tube 6430206
£ 955.00 (ex. VAT) 1 in stock
Thomson Linear Micron DuraTRUE 90 Right Angle Gearhead Ratio:250:1 Y-Axis
ITEM-30595
Thomson Linear Micron DuraTRUE 90 Right Angle Gearhead Ratio:250:1 Y-Axis
This was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition but has not been tested.
£ 955.00 (ex. VAT) 1 in stock
Thomson Linear Micron DuraTRUE 115 Gear Motor Ratio:250:1 X-Axis
ITEM-30593
Thomson Linear Micron DuraTRUE 115 Gear Motor Ratio:250:1 X-Axis
This was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition with marks from use but has not been tested.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 950.00 (ex. VAT) 1 in stock
Thermo Scientific MAXQ 5000 SHKE5000-1CE (4351) Shaking Incubator Lab Faulty
ITEM-39911
Thermo Scientific MAXQ 5000 SHKE5000-1CE (4351) Shaking Incubator
This was removed from a university lab where it was surplus to requirements.
The system is faulty and requires a new controller.
It is in otherwise good cosmetic condition with minor marks.
It is sold for spares/repairs.
£ 950.00 (ex. VAT) 1 in stock
Varian TV 81-T Turbo Turbomolecular Pump Model 9698905M001 Lab
ITEM-30514
This Varian TV 81-T Turbo Turbomolecular Pump Model 9698905M001 was removed from a university lab where it was surplus to requirements.
The pump has been tested with a controller (not included) and is in working order, but has not been tested under a vacuum.
It is in good cosmetic condition with minor marks from use.
£ 950.00 (ex. VAT) 1 in stock
Eco Chemie AutoLab SPR Biosensor Instrument with Accessories Lab
ITEM-24615
This Eco Chemie AutoLab SPR Biosensor Instrument with Accessories was removed from a university lab where it was surplus to requirements.
The unit powers on and is in good cosmetic condition with some marks from use. It was not tested further.
Included with it are;
1 x Box of Accessories containing:
1x Detector test report
1x Specifications brochure
1x Curved mirror L120-5208
1x Plastic/ rubber bung
1x Black foam O ring
4x Allen keys 0990-7918/ 0990-7297/ 0990-7928/0990-7917
3x Bags of screws 0000-2678/ 0000-3465/ 0499-4450
6x Washers 0000-3109/ 0000-2687
3x Ballbarings 0497-3103
1x Metal plate L120-2056
1X Plastic syringe 0494-3036
£ 950.00 (ex. VAT) 1 in stock
BECKMAN Model J2-21 Floor Standing Centrifuge Lab
ITEM-21249
This BECKMAN Model J2-21 Floor Standing Centrifuge was removed from a university lab where it was surplus to requirements.
The unit is in full working order but is not supplied with a rotor.
It is in reasonably good cosmetic condition but has cracks on the door hinge and latch.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 950.00 (ex. VAT) 1 in stock
Medline Scientific Incubated Shaker Model - IS-971RF Spares/Repairs
ITEM-20411
This Medline Scientific Incubated Shaker Model - IS-971RF was removed from a university lab where it was surplus to requirements.
The unit powers up and has been tested with a digital thermometer (not included). It was set to 37˚C but only reached 31˚C. The display would keep reverting to 22.2˚C as well. There was a note from the lab stating that it had some heating issues.
Inside dimensions - L89.5 x W63 x D48cm
Platform size - 46 x 76cm
The shaker speed ran up to 160rpm. We tried setting it to the max of 300 but it wouldn't run at that.
Cosmetically it is in a reasonable used condition but all the light tubes work bar one.
It is sold for spares/repairs due to the fault.
£ 950.00 (ex. VAT) 1 in stock
Coherent Enterprise Laser Head & Coherent Laserpure 5 Chiller Lab
ITEM-39743
Coherent Enterprise Laser Head & Coherent Laserpure 5 Chiller
This system was removed from a university lab where it was surplus to requirements.
The units both power up but have not been tested further. They are in good cosmetic condition with marks from use.
Included are;
Coherent Enterprise Laser Head Power Supply
Model: ENTCII-653
Serial#: 020775654-ENIC
Manu: July, 2002
Coherent Laserpure 5 Heat Exchanger water-to-water Laser Cooling System
Model: LP-51
Serial#: 17772
Manu: 13 May, 2002
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 950.00 (ex. VAT) 1 in stock
New Brunswick Innova Type 4330 Incubator Shaker Lab
ITEM-40993
This New Brunswick Innova Type 4330 Incubator Shaker was removed from a university lab where it was surplus to requirements.
The unit powers up and heats, but does not cool or shake.
It is sold for spares/repairs.
£ 950.00 (ex. VAT) 1 in stock
Applied Biosystems ABI Prism 7900HT Sequence Detection System Lab Spares/Repairs
ITEM-30573
Applied Biosystems ABI Prism 7900HT
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has the following issues.
The 7900 did connect to the PC at first but there appears to be a fault with the plate loader. The door will not open when instructed. If you try to run a program you get a 3003 error. 'unable to load the plate, Tray not at up position'.
There was a loud humming noise coming from the unit which appeared to get louder the longer it was switched on. Then would no longer connect to the PC. We have removed the side panels but cannot see any obvious issues.
It is sold for spares/repairs.
The PC is included.
Dell Optiplex PC
Dell 17" Monitor
Keyboard & Mouse
USB Cable
DVI Cable
All parts power on and work, the pc has ABI 7900HT Sequence Detection Systems Version 2.4.1 Software.
£ 945.00 (ex. VAT) 1 in stock
Pharmacia Biotech FPLC System - LCC-500 UV-M II P-500 Lab
ITEM-37883
Pharmacia Biotech FPLC System
This was removed from a university lab where it was surplus to requirements.
The system has been powered up but not tested further. Everything is in reasonable to poor cosmetic condition.
All the units plugged into a power strip that supports EU plugs.
Included are;
2 x Connectivity Monitor, 004763/System No. 003763, 004518/System No. 003518
1 x Pump P-500, 017517
1 x Liquid Chromatography Controller LCC-500 Plus, 331543
1 x UV-M II, 004586
2 x MotorValve MV-7
1 x 10200 PERSPEX Peristaltic Pump, 5024
£ 940.00 (ex. VAT) 1 in stock
FB Fans & Blowers Ltd Centrifugal Fan Type 400 (350) SBSZ100 & Controller
ITEM-38892
FB Fans & Blowers Ltd Centrifugal Fan Type 400 (350) SBSZ100
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in full working order to 3250rpm
It is in good cosmetic condition with minor marks.
£ 940.00 (ex. VAT) 1 in stock
Orbit Marine Div AL-7100-LCU Local Control Unit
ITEM-30581
This Orbit Marine AL-7100-LCU Local Control Unit was removed from a university lab where it was surplus to requirements.
The unit is in good cosmetic condition with marks from use. It has not been tested.
Items 1501 to 1550 of 3312